Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “small signal stability analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Stability analysis and compensation of a boost regulator with two-loop control

A useful stability measure has been demonstrated by Wester (1973) for switching regulators with a single feedback loop by applying the Nyquist criterion to the approximate loop gain determined by a time-averaging technique. This approach is extended and applied to the characterization, stability analysis, and compensation design of a switching regulator with two-loop control. The role and relative significance of each control loop is clarified on the basis of a description of circuit operation, and the major and minor loops are identified. In view of the inapplicability of linear feedback theory, describing functions of the feedback loops and power stage are derived, using small-signal analysis. Several phenomena revealed from an analysis of the major loop gain are discussed.

Wester, G. W.↗

Small-Signal Stability Impacts of Load and Network Dynamics on Grid-Forming Inverters

This paper presents several stability analyses for grid-forming inverters and synchronous generators considering the dynamics of transmission lines and different load models. Load models are usually of secondary importance compared to generation source models, but as the results show, they play a crucial role in stability studies with the introduction of inverter-based resources. Given inverter control time scales, the implications of considering or neglecting electromagnetic transients of the network are very relevant in the stability assessments. In this paper, we perform eigenvalue analyses for inverter-based resources and synchronous machines connected to a load and explore the effects of multiples models under different network representations. We explore maximum loadability of inverter-based resources and synchronous machines, while analyzing the effects of load and network dynamic models on small-signal stability. The results show that the network representation plays a fundamental role in the stability of the system of different load models. The resulting stability regions are significantly different depending on the source and load model considered.

grid forming inverters↗

Analysis and design of an adaptive multi-loop controlled two winding buck/boost regulator

Small signal low frequency linear average model is derived for a multi-loop controlled two-winding buck/boost converter employing average techniques and the describing function method. The model reveals that a well-designed multi-loop control can provide a second-order zero adaptive to output filter parameter changes due to component tolerances, temperature changes, aging, and the effect of duty cycle modulation. It also can provide stabilization effect by shifting the positive zero to the left-half S-plane. Design guidelines are formulated to optimize regulator-loop dependent characteristics.

Mahmoud, M. F.↗

On the Sensitivity of Piezoceramics and Piezopolymers in Structural Integrity Monitoring of Large Trusses

An analytical assessment has been made of the reliability of using integrated microactuators and sensors in the form of piezoceramics and piezopolymers as joint integrity monitors in trussed systems. The concept is first implemented for a simple structure which consists of two truss members with a 45 deg lift angle joined at the apex. A piezoceramic patch (or piezopolymer film) bonded on the surface of one of the members at a location near the joint is used as a collocated actuator/sensor. The overall structural dynamic response under an excitation was modeled by finite element method. Different degrees of nodal constraints at the joints representing various degrees of joint integrity are employed. The resulting dynamic response showed distinct responses for varying joint stiffnesses. Parallel experimental work on a truss model using a multichannel data acquisition system and a digital signal analyzer confirms the results from analysis. We further studied the sensitivity of the micro-sensors to the behavior of joints of large arch truss structure. Results obtained for large trusses with many degrees of freedom indicate optimum locations of sensors for which the dynamic response signatures are distinct and distinguishable for relatively small changes in joint integrity and/or structural geometry. Computations based on finite element modeling show that locating the single actuator/sensor at the joint corresponding to the first loss of static stability appear optimal. Hence, static stability analysis of complex trusses can give us a good indication of the optimum placement of sensors for maximum response. This observation is important if few distributed sensors and actuators are available for placement in constructed facilities made from large trusses with many degrees of freedom. As an extension of this work a dynamic response signature identification technique to monitor in-service degradation of joints is under development for application to the monitoring of the integrity of adhesive joints in composite structures.

Abatan, A. O.↗

Comparison of experimental rotor damping data-reduction techniques

The ability of existing data reduction techniques to determine frequency and damping from transient time-history records was evaluated. Analog data records representative of small-scale helicopter aeroelastic stability tests were analyzed. The data records were selected to provide information on the accuracy of reduced frequency and decay coefficients as a function of modal damping level, modal frequency, number of modes present in the time history record, proximity to other modes with different frequencies, steady offset in time history, and signal-to-noise ratio. The study utilized the results from each of the major U.S. helicopter manufacturers, the U.S. Army Aeroflightdynamics Directorate, and NASA Ames Research Center using their inhouse data reduction and analysis techniques. Consequently, the accuracy of different data analysis techniques and the manner in which they were implemented were also evaluated. It was found that modal frequencies can be accurately determined even in the presence of significant random and periodic noise. Identified decay coefficients do, however, show considerable variation, particularly for highly damped modes. The manner in which the data are reduced and the role of the data analyst was shown to be important. Although several different damping determination methods were used, no clear trends were evident for the observed differences between the individual analysis techniques. It is concluded that the data reduction of modal-damping characteristics from transient time histories results in a range of damping values.

Warmbrodt, William↗

Analysis Background & Noise in Stretched Wire Alignment Technique Measurements

The Stretched-Wire Alignment Technique (SWAT) is one method of magnet alignment for linear induction accelerators. The applications of SWAT have been implemented for aligning solenoid magnets on the Scorpius linear induction accelerator which will be sited at the Nevada National Security Site and the Flash X-Ray (FXR) linear induction accelerator at Lawrence Livermore National Laboratory’s Contained Firing Facility. This article describes both systematic (repeatable) and random sources of background and noise as well as practical ways to eliminate or reduce them to acceptable levels. Systematic sources include reflections from wire ends, rapid sag due to ohmic heating of the wire, magnetic materials, and shot rate. Random sources include air currents, vibration of nearby equipment, mechanical stability of test equipment, and the instruments used to measure the wire motion. Mitigations include curve fitting and adaptive noise signal cancellation, and mechanical damping. Finite Element Analysis (FEA) was used to identify and resolve a repeatable wire vibration frequency interfering with the signal resolution. Two stretched wire alignment technique set ups from Sandia National Labs and Lawrence Livermore National Lab have shown background noise sources and ways of mitigating them by either analysis methods or change of mechanical configuration. Conclusions that were drawn included the severe sensitivity of the deflection to even small external interferences of the SWAT wire such that it requires attention to detail in mechanical set up and analysis.

Linear Inductive Accelerator↗

Changes induced on the surfaces of small Pd clusters by the thermal desorption of CO

The stability and adsorption/desorption properties of supported Pd crystallites less than 5 nm in size were studied by Auger electron spectroscopy and repeated flash thermal desorption of CO. The Pd particles were grown epitaxially on heat-treated, UHV-cleaved mica at a substrate temperature of 300 C and a Pd impingement flux of 10 to the 13th atoms/sq cm s. Auger analysis allowed in situ measurement of relative particle dispersion and contamination, while FTD monitored the CO desorption properties. The results show that significant changes in the adsorption properties can be detected. Changes in the Pd Auger signal and the desorption spectrum during the first few thermal cycles are due to particle coalescence and facetting and the rate of this change is dependent on the temperature and duration of the desorption. Significant reductions in the amplitude of the desorptions peak occur during successive CO desorptions which are attributed to increases of surface carbon, induced by the desorption of CO. The contamination process could be reversed by heat treatment in oxygen or hydrogen

Doering, D. L.↗

Estimation of Electromechanical Modes of Oscillation in the Eastern Interconnection from Ambient PMU Data

A power system's inter-area electromechanical modes of oscillation determine if the system is small-signal stable. Mode meters are tools that estimate the modes based on ambient synchrophasor measurements, allowing continuous monitoring of the system's stability margin. This paper reports on the application of mode meter algorithms to 21 months of synchrophasor measurements from the United States Eastern Interconnection (EI). Estimates for three modes were updated every minute, providing a much more comprehensive set of results than previous studies based on disturbance recordings. The detailed signal designs and mode meter configurations provided in this paper can be used to accelerate mode meter deployments in the EI. Analysis of the mode estimates reveal for the first time how seasonal load changes and system reconfiguration impact the EI system's dynamics.

Follum, James D.↗

Early Oscillation Detection Technique for Hybrid DC/DC Converters

Oscillation or instability is a situation that must be avoided for reliable hybrid DC/DC converters. A real-time electronics measurement technique was developed to detect catastrophic oscillations at early stages for hybrid DC/DC converters. It is capable of identifying low-level oscillation and determining the degree of the oscillation at a unique frequency for every individual model of the converters without disturbing their normal operations. This technique is specially developed for space-used hybrid DC/DC converters, but it is also suitable for most of commercial and military switching-mode power supplies. This is a weak-electronic-signal detection technique to detect hybrid DC/DC converter oscillation presented as a specific noise signal at power input pins. It is based on principles of feedback control loop oscillation and RF signal modulations, and is realized by using signal power spectral analysis. On the power spectrum, a channel power amplitude at characteristic frequency (CPcf) and a channel power amplitude at switching frequency (CPsw) are chosen as oscillation level indicators. If the converter is stable, the CPcf is a very small pulse and the CPsw is a larger, clear, single pulse. At early stage of oscillation, the CPcf increases to a certain level and the CPsw shows a small pair of sideband pulses around it. If the converter oscillates, the CPcf reaches to a higher level and the CPsw shows more high-level sideband pulses. A comprehensive stability index (CSI) is adopted as a quantitative measure to accurately assign a degree of stability to a specific DC/DC converter. The CSI is a ratio of normal and abnormal power spectral density, and can be calculated using specified and measured CPcf and CPsw data. The novel and unique feature of this technique is the use of power channel amplitudes at characteristic frequency and switching frequency to evaluate stability and identify oscillations at an early stage without interfering with a DC/DC converter s normal operation. This technique eliminates the probing problem of a gain/phase margin method by connecting the power input to a spectral analyzer. Therefore, it is able to evaluate stability for all kinds of hybrid DC/DC converters with or without remote sense pins, and is suitable for real-time and in-circuit testing. This frequency-domain technique is more sensitive to detect oscillation at early stage than the time-domain method using an oscilloscope.

Wang, Bright L.↗

Time Delay of Wide Area Damping Control in Urban Power Grid: Model-Based Analysis and Data-Driven Compensation

Due to the rapid development of economies, large urban cities consume an increasing amount of energy and have a higher requirement for power quality. Voltage source converter based high voltage direct current (VSC-HVDC) is a promising device to transmit clean power from remote regions to urban power systems, while also providing wide area damping control (WADC) for frequency stabilization. However, the time-delay naturally existing in the VSC-HVDC system may degrade the performance of WADC and even result in instability. To address this issue, this paper develops a time-delay correction control strategy for VSC-HVDC damping control in urban power grids. First, a small signal model of WADC is built to analyze the negative impacts of time delay. Then, a data-driven approach is proposed to compensate for the inherent time delay in VSC-HVDC damping control. The extensive training data will be generated under various disturbances. After offline training, the long short-term memory network (LSTM) can be implemented online to predict the actual frequency deviation based on real-time measurements. Finally, the proposed method is validated through MATLAB-Simulink in a two-area four-machine system. The results indicate that the data-driven compensation has a strong generalization ability for random delay time constants and can improve the performance of WADC significantly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lessons from 18 Years of Hyperspectral Infrared Sounder Data

By the end of 2013 NASA and EUMETSAT will have accumulated more than 11 years of AIRS, 6 years of IASI and one year of CrIS data. All three instruments were nominally specified to support the NWC for short term weather forecasting with a five year lifetime, but continue to exceed the accuracy requirement needed for weather forecasting alone. This allows use of their data for a much broader range of applications, including the calibration of broad-band instruments in space and climate research. We illustrate calibration aspects with examples from AIRS, IASI and CrIS using spatially uniform clear conditions, simultaneous nadir overpasses and random nadir samples. The differences between AIRS, IASI and CrIS for the purpose of weather forecasting are small and we expect that the excellent forecast impact demonstrated by the combination of AIRS and IASI will be continued by the combination of CrIS and IASI. Clear data are useful for calibration, but contain no climate signal. The analysis of random nadir samples from AIRS and CrIS identifies larger biases for observation of extreme conditions, represented by 1% and 99%tile data than for non-extreme observations. This is relevant for climate analysis. Resolution of these differences require further work, since they can complicate the continuation of trends established by AIRS with CrIS data, at least for extrema. The unequaled stability of the AIRS data allows us to evaluate trends using random nadir sampled data. We see an increasing frequency in severe storms over land, a decreasing frequency over ocean. The 11 years of AIRS data are too short to tell if these trends are significant from a climate change viewpoint, or if they are parts of multi-decadal oscillations.

CRIS↗

Electrical performance characteristics of high power converters for space power applications

The first goal of this project was to investigate various converters that would be suitable for processing electric power derived from a nuclear reactor. The implementation is indicated of a 20 kHz system that includes a source converter, a ballast converter, and a fixed frequency converter for generating the 20 kHz output. This system can be converted to dc simply by removing the fixed frequency converter. This present study emphasized the design and testing of the source and ballast converters. A push-pull current-fed (PPCF) design was selected for the source converter, and a 2.7 kW version of this was implemented using three 900 watt modules in parallel. The characteristic equation for two converters in parallel was derived, but this analysis did not yield any experimental methods for measuring relative stability. The three source modules were first tested individually and then in parallel as a 2.7 kW system. All tests proved to be satisfactory; the system was stable; efficiency and regulation were acceptable; and the system was fault tolerant. The design of a ballast-load converter, which was operated as a shunt regulator, was investigated. The proposed power circuit is suitable for use with BJTs because proportional base drive is easily implemented. A control circuit which minimizes switching frequency ripple and automatically bypasses a faulty shunt section was developed. A nonlinear state-space-averaged model of the shunt regulator was developed and shown to produce an accurate incremental (small-signal) dynamic model, even though the usual state-space-averaging assumptions were not met. The nonlinear model was also shown to be useful for large-signal dynamic simulation using PSpice.

Stuart, Thomas A.↗

A Lyapunov-Based Generalized Dc-Side Controller Design for PV-Connected Systems: Preprint

The objective of this paper is to realize a universal dc-side controller for photovoltaic (PV) systems where the control is agnostic to the downstream converter configuration. To achieve this, the downstream power converter and its controls are manipulated into an effective power control loop that is then cast into a generalized multi-loop design framework. On the dc side, a nonlinear small-signal model of the PV input is realized exclusively in terms of PV datasheet parameters (i.e., open-circuit voltage, short-circuit current, and maximum power point). Finally, a linear controller is used to modulate the dc-side PV system with the generic downstream power controller. A Lyapunov candidate is proposed to analyze the stability of the interconnected system and provide a streamlined approach for the controller design. The proposed design is validated on a 1-kVA experimental setup that interfaces a PV module to the grid.

dc-dc control↗

An organogel library for solution NMR analysis of nanoparticle suspensions in non-aqueous samples

Surface contrast solution NMR methods (scNMR) are emerging as powerful tools to investigate the adsorption of small molecule ligands to the surface of nanoparticles (NP), returning fundamental insight into the kinetics and thermodynamics of sorption, as well as structural information on the adsorbed species. A prerequisite for the acquisition of high quality solution NMR data is the preparation of homogeneous and stable samples that return consistent NMR spectra and allow extensive signal averaging. Unfortunately, this condition does not apply to NMR samples containing NPs that often show a tendency to sediment and accumulate at the bottom of the NMR tube over the course of the experiment. We have recently shown that preparing NMR samples in an agarose gel matrix inhibits sedimentation and allows the characterization of small molecule-NP interactions by scNMR. Unfortunately, as the agarose gel only forms in aqueous solution, this sample preparation method cannot be used to stabilize NP suspensions in a non-aqueous environment. In this work, we introduce a library of 48 organogels, based on low molecular-mass organic gelators (LMOGs), to prepare NMR samples of small molecule/NP systems in a wide range of organic solvents. In addition, we present a simple method that takes advantage of 1H transverse relaxation (1H-R2) measurements to screen the library and identify the best gelator to characterize the small molecule-NP interaction of interest in the solvent of choice. We expect the results of this study will enable the preparation of homogeneous and stable samples of NPs in non-aqueous environments, therefore dramatically increasing the applicability of scNMR to the characterization of heterogeneous interactions and to the investigation of the role played by solvent molecules in regulating the kinetics and thermodynamics of sorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Test Report: Low-Cost Access to TDRS Using TOPEX to Emulate Small Satellite Performance

This report lists the objectives and conclusions of a series of experimental contacts between the TOPEX and the TDRS satellites. These experiments are designed to verify the theoretical prediction that a spin-stabilized satellite with a broad-beam, zenith-pointing antenna can have regular, significant contacts with the TDRS and use those contacts for data services. This series of experiments is a joint project between the experimenters at New Mexico State University (NMSU), the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC), and the Jet Propulsion Laboratory (JPL). In these experiments, we show that: (1) The satellite contacts during the experiment begin and end as predicted prior to the experiment; (2) The data contact is held for the desired contact duration; (3) The data quality through the contact is high and similar to that required by actual project needs; and (4) The receiving hardware at the White Sands Complex (WSC) is able to track the signals better than expected by analysis of the antenna pattern effects alone predict. We believe that these experiments successfully demonstrate the basic concept and its validity with actual spacecraft systems.

Horan, Stephen↗

State-Constrained Grid-Forming Inverter Control for Robust Operation of AC Microgrids

The control of grid-forming inverters has become an important problem to achieve high efficiency, reliability, and resilience of the future power grid. The distributed control that utilizes a sparse communication network has been proposed for AC microgrids, in which each DG only has access to the information of a small number of its neighboring DGs, reducing the computational complexity and improving the resiliency to faults and unknown parameters. However, these approaches have not provided a clear analysis of the coupling between active/reactive power injections and the voltage magnitude/frequency or a distributed updating law with a solid theoretical foundation. Additionally, in the existing approaches, tracking the references from the secondary control may violate operational constraints.

Xu, Ying↗