Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Equivalent Sensor Radiance Generation and Remote Sensing from Model Parameters: Equivalent Sensor Radiance Formulation - Part 1

In this paper we describe a general procedure for calculating equivalent sensor radiances from variables output from a global atmospheric forecast model. In order to take proper account of the discrepancies between model resolution and sensor footprint the algorithm takes explicit account of the model subgrid variability, in particular its description of the probably density function of total water (vapor and cloud condensate.) The equivalent sensor radiances are then substituted into an operational remote sensing algorithm processing chain to produce a variety of remote sensing products that would normally be produced from actual sensor output. This output can then be used for a wide variety of purposes such as model parameter verification, remote sensing algorithm validation, testing of new retrieval methods and future sensor studies. We show a specific implementation using the GEOS-5 model, the MODIS instrument and the MODIS Adaptive Processing System (MODAPS) Data Collection 5.1 operational remote sensing cloud algorithm processing chain (including the cloud mask, cloud top properties and cloud optical and microphysical properties products.) We focus on clouds and cloud/aerosol interactions, because they are very important to model development and improvement.

Simulations↗

First Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the sensor was initially investigated with analytical derivations and with COMSOL RF Module computer simulations of resonant frequency spectral shift due to uniform load. We also investigated the mechanical integrity of the flowmeter’s membrane through analytical modelling and COMSOL Structural Mechanics Module computer simulations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the material’s yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure. Using results from models, we have developed an initial design for a microwave K-band sensor. A cylindrical resonator prototype was fabricated from brass for the initial tests. The external dimensions of the cavity are matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed consisting of a piping Tee with a bulkhead WR-42 microwave waveguide installed in a leak-proof assembly. A microwave waveguide circulator was installed in the setup to suppress the effect of reflections at the cavity entrance by increasing the isolation between the input and the output port. Preliminary spectral characterization of cavity spectral response was performed with a portable PXIe chassis microwave VNA with a custom GUI. Preliminary dry tests of the transducer response were conducted with a set of calibrated weights. Transducer frequency shift was shown to be monotonically increasing with increasing pressure. The next steps will involve investigation of the transducer performance for water flow sensing.

42 ENGINEERING↗

Model-based sensor location selection for helicopter gearbox monitoring

A new methodology is introduced to quantify the significance of accelerometer locations for fault diagnosis of helicopter gearboxes. The basis for this methodology is an influence model which represents the effect of various component faults on accelerometer readings. Based on this model, a set of selection indices are defined to characterize the diagnosability of each component, the coverage of each accelerometer, and the relative redundancy between the accelerometers. The effectiveness of these indices is evaluated experimentally by measurement-fault data obtained from an OH-58A main rotor gearbox. These data are used to obtain a ranking of individual accelerometers according to their significance in diagnosis. Comparison between the experimentally obtained rankings and those obtained from the selection indices indicates that the proposed methodology offers a systematic means for accelerometer location selection.

Jammu, Vinay B.↗

Multi-sensor Cloud Retrieval Simulator and Remote Sensing from Model Parameters : Synthetic Sensor Radiance Formulation - Pt. 1

In this paper we describe a general procedure for calculating synthetic sensor radiances from variable output from a global atmospheric forecast model. In order to take proper account of the discrepancies between model resolution and sensor footprint, the algorithm takes explicit account of the model subgrid variability, in particular its description of the probability density function of total water (vapor and cloud condensate.) The simulated sensor radiances are then substituted into an operational remote sensing algorithm processing chain to produce a variety of remote sensing products that would normally be produced from actual sensor output. This output can then be used for a wide variety of purposes such as model parameter verification, remote sensing algorithm validation, testing of new retrieval methods and future sensor studies.We show a specific implementation using the GEOS-5 model, the MODIS instrument and the MODIS Adaptive Processing System (MODAPS) Data Collection 5.1 operational remote sensing cloud algorithm processing chain (including the cloud mask, cloud top properties and cloud optical and microphysical properties products). We focus on clouds because they are very important to model development and improvement.

Simulations↗

Demonstration of Microwave Resonant Cavity Transducer Performance in Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. To validate sensor physics, we have performed proof-of-principle test of flow sensing in water. For this test, we have developed a cylindrical resonator for K-band, which was machined from brass. The cavity was excited through WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder. To increase the spectral signal visibility, we developed a signal processing method for baseline subtraction. A flow loop for proof-of-principle test of transducer performance in water was assembled. A commercial flow meter was installed in the loop for reference measurements. Cylindrical cavity was excited in the TEM 011 mode with resonant frequency f ≈ 17.8GHz. Frequency shift of cavity spectral response was obtained by gradually increasing water flow rate from 0 to 60gpm. Corresponding monotonic increase of resonant frequency shift by several MHz was observed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Autonomous reconfigurable virtual sensing system for cyber-attack neutralization

An industrial asset may be associated with a plurality of monitoring nodes, each monitoring node generating a series of monitoring node values over time representing current operation of the industrial asset. An abnormality detection computer may determine that at least one abnormal monitoring node is currently being attacked or experiencing a fault. A virtual sensing estimator may continuously execute an adaptive learning process to create or update virtual sensor models for the monitoring nodes. Responsive to an indication that a monitoring node is currently being attacked or experiencing a fault, the virtual sensing estimator may be dynamically reconfigured to estimate a series of virtual node values for the abnormal monitoring node or nodes based on information from normal monitoring nodes and appropriate virtual sensor models. The series of monitoring node values from the abnormal monitoring node or nodes may then be replaced with the virtual node values.

97 MATHEMATICS AND COMPUTING↗

Adaptive, self-tuning virtual sensing system for cyber-attack neutralization

An industrial asset may have a plurality of monitoring nodes, each monitoring node generating a series of monitoring node values over time representing current operation of the industrial asset. An abnormality detection computer may determine that an abnormal monitoring node is currently being attacked or experiencing a fault. An autonomous, resilient estimator may continuously execute an adaptive learning process to create or update virtual sensor models for that monitoring node. Responsive to an indication that a monitoring node is currently being attacked or experiencing a fault, a level of neutralization may be automatically determined. The autonomous, resilient estimator may then be dynamically reconfigured to estimate a series of virtual node values based on information from normal monitoring nodes, appropriate virtual sensor models, and the determined level of neutralization. The series of monitoring node values from the abnormal monitoring node or nodes may then be replaced with the virtual node values.

Abbaszadeh, Masoud↗

Design of Microwave Resonant Cavity Transducer. Development of sensor performance model of microwave cavity flow meter for advanced reactor high temperature fluids

High-temperature fluid reactors, such as molten salt cooled reactors (MSCR) and sodium fast reactors (SFR), are a promising advanced reactor option. Measurement of high-temperature fluid process variables, in particular the flow inside the pressure vessel, is a challenging task because of harsh environment, which includes high radiation, high temperature, and contact with highly corrosive coolant fluid. We are investigating a microwave cavity-based transducer for high-temperature fluid flow sensing. This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. A cavity is characterized by its resonant frequencies. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the flow sensor is evaluated with signal sensitivity using COMSOL computer simulations. A right cylinder geometry stainless steel cavity with dimeter of 0.8in was investigated. We choose membrane thickness of 10mil, so that corrosion anticipated to proceed at the rate of 1mil/year in liquid sodium would affect no more than 10% of the membrane. Using the properties of liquid sodium fluid, and stainless-steel material property values at 500oC, we calculate frequency shift for a range of values of fluid velocity from 0.5m/s to 2m/s. Results of computer simulations indicate measurable sensitivity to flow for this cavity design. Following these simulations, we have developed a preliminary design for fabrication of a transducer operating in microwave K-band for proof-of-principle tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of response models for the Earth Radiation Budget Experiment (ERBE) sensors. Part 4: Preliminary nonscanner models and count conversion algorithms

Two count conversion algorithms and the associated dynamic sensor model for the M/WFOV nonscanner radiometers are defined. The sensor model provides and updates the constants necessary for the conversion algorithms, though the frequency with which these updates were needed was uncertain. This analysis therefore develops mathematical models for the conversion of irradiance at the sensor field of view (FOV) limiter into data counts, derives from this model two algorithms for the conversion of data counts to irradiance at the sensor FOV aperture and develops measurement models which account for a specific target source together with a sensor. The resulting algorithms are of the gain/offset and Kalman filter types. The gain/offset algorithm was chosen since it provided sufficient accuracy using simpler computations.

Halyo, Nesim↗