Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “science traceability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Origins and evolution of viruses of eukaryotes: The ultimate modularity

Viruses and other selfish genetic elements are dominant entities in the biosphere, with respect to both physical abundance and genetic diversity. Various selfish elements parasitize on all cellular life forms. The relative abundances of different classes of viruses are dramatically different between prokaryotes and eukaryotes. In prokaryotes, the great majority of viruses possess double-stranded (ds) DNA genomes, with a substantial minority of single-stranded (ss) DNA viruses and only limited presence of RNA viruses. In contrast, in eukaryotes, RNA viruses account for the majority of the virome diversity although ssDNA and dsDNA viruses are common as well. Phylogenomic analysis yields tangible clues for the origins of major classes of eukaryotic viruses and in particular their likely roots in prokaryotes. Specifically, the ancestral genome of positive-strand RNA viruses of eukaryotes might have been assembled de novo from genes derived from prokaryotic retroelements and bacteria although a primordial origin of this class of viruses cannot be ruled out. Different groups of double-stranded RNA viruses derive either from dsRNA bacteriophages or from positive-strand RNA viruses. The eukaryotic ssDNA viruses apparently evolved via a fusion of genes from prokaryotic rolling circle-replicating plasmids and positive-strand RNA viruses. Different families of eukaryotic dsDNA viruses appear to have originated from specific groups of bacteriophages on at least two independent occasions. Polintons, the largest known eukaryotic transposons, predicted to also form virus particles, most likely, were the evolutionary intermediates between bacterial tectiviruses and several groups of eukaryotic dsDNA viruses including the proposed order “Megavirales” that unites diverse families of large and giant viruses. Strikingly, evolution of all classes of eukaryotic viruses appears to have involved fusion between structural and replicative gene modules derived from different sources along with additional acquisitions of diverse genes. - Highlights: • Eukaryotic virome dramatically differs from the viromes of bacteria and archaea. • Eukaryotic virome is dominated by RNA viruses and retroelements. • All classes of eukaryotic viruses evolved by gene module exchange. • Prokaryotic ancestry is traceable for core gene modules of most eukaryotic viruses. • Evolutionary histories of viruses and transposable elements are tightly linked.

60 APPLIED LIFE SCIENCES↗

Microbial co-habitation and lateral gene transfer: what transposases can tell us

Determining the habitat range for various microbes is not a simple, straightforward matter, as habitats interlace, microbes move between habitats, and microbial communities change over time. In this study, we explore an approach using the history of lateral gene transfer recorded in microbial genomes to begin to answer two key questions: where have you been and who have you been with? All currently sequenced microbial genomes were surveyed to identify pairs of taxa that share a transposase that is likely to have been acquired through lateral gene transfer. A microbial interaction network including almost 800 organisms was then derived from these connections. Although the majority of the connections are between closely related organisms with the same or overlapping habitat assignments, numerous examples were found of cross-habitat and cross-phylum connections. We present a large-scale study of the distributions of transposases across phylogeny and habitat, and find a significant correlation between habitat and transposase connections. We observed cases where phylogenetic boundaries are traversed, especially when organisms share habitats; this suggests that the potential exists for genetic material to move laterally between diverse groups via bridging connections. The results presented here also suggest that the complex dynamics of microbial ecology may be traceable in the microbial genomes.

59 BASIC BIOLOGICAL SCIENCES↗

Traceable Co-C eutectic points for thermocouple calibration

National Measurement Institute of Australia (NMIA) has developed a miniature crucible design suitable for measurement by both thermocouples and radiation thermometry, and has established an ensemble of five Co-C eutectic-point cells based on this design. The cells in this ensemble have been individually calibrated using both ITS-90 radiation thermometry and thermocouples calibrated on the ITS-90 by the NMIA mini-coil methodology. The assigned ITS-90 temperatures obtained using these different techniques are both repeatable and consistent, despite the use of different furnaces and measurement conditions. The results demonstrate that, if individually calibrated, such cells can be practically used as part of a national traceability scheme for thermocouple calibration, providing a useful intermediate calibration point between Cu and Pd.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of Recent and Historical Comparisons Between Absolute Cavity Pyrgeometer (ACP), InfraRed Integrating Sphere (IRIS)

Results of seven comparisons between ACPs and IRISs. Difference between the longwave irradiance measured by the ACPs and IRISs versus the irradiance measured by the WISG. The longwave irradiance measured by the ACPs, IRISs, and AERI versus the irradiance measured by the WISG. Recommendations to establish the world reference for measuring the atmospheric longwave irradiance with traceability to the International System of Units (SI).

54 ENVIRONMENTAL SCIENCES↗

Learning to Apply Metrology Principles to the Measurement of X-ray Intensities in the 500 eV to 110 keV Energy Range

National Security Technologies, LLC (NSTec), Livermore Operations, has two optical radiation calibration laboratories accredited by “the National Voluntary Laboratories Accreditation Program (NVLAP) which is the accrediting body of” the National Institute of Standards and Technology (NIST), and is now working towards accreditation for its X-ray laboratories. NSTec operates several laboratories with X-ray sources that generate X-rays in the energy range from 50 eV to 115 keV. These X-ray sources are used to characterize and calibrate diagnostics and diagnostic components used by the various national laboratories, particularly for plasma analysis on the Lawrence Livermore National Laboratory (LLNL) National Ignition Facility (NIF). Because X-ray photon flux measurement methods that can be accredited, i.e., traceable to NIST, have not been developed for sources operating in these energy ranges, NSTec, NIST, and the National Voluntary Accreditation Program (NVLAP) together have defined a path toward the development and validation of accredited metrology methods for X-ray energies. The methodology developed for the high energy X-ray (HEX) Laboratory was NSTec’s starting point for X-ray metrology accreditation and will be the basis for the accredited processes in the other X-ray laboratories. This paper will serve as a teaching tool, by way of this example using the NSTec X-ray sources, for the process and methods used in developing an accredited traceable metrology.

07 ISOTOPE AND RADIATION SOURCES↗

Solid, structured composite neutron detectors with high dynamic range capability

Neutron detectors are essential across disciplines such as fundamental science, nuclear security, safeguards, and civilian applications. While 3 He-filled gas proportional counters have long been revered for their efficacy in detecting thermal neutrons and praised for their efficiency, neutron/gamma discrimination, and stability, the scarcity of 3He has spurred a search for alternatives. Here, we explore a solid structured scintillating particle composite (SPC) consisting of 6 Li-containing scintillating glass particles within an acrylic matrix as a neutron detector for high dynamic range applications. We show for the first time that an SPC neutron detector can boast an intrinsic detection efficiency of 0.261% for pure 252 Cf fission neutrons and an overall neutron detection efficiency of (0.546 ± 0.003)% at the Neutron Free-in-Air facility while being able to function in an intense gamma-ray environment. We also show that the SPC neutron detector supports fast neutron capture times and enables a dual-readout scheme that extends the detector dynamic range to high incident neutron fluxes. A scalable fabrication process allows for tailoring the SPC detector properties to the requirements of specific applications. Good agreement is found between the experimental results taken with a National Institute of Standards and Technology traceable 252 Cf source and the coupled MCNP6 and optical-ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanodiamonds in Advancing Biomedical Sciences

Nanodiamonds (NDs), tetrahedral carbon frameworks with size ranging from 1 to 100 nanometers, have gained growing attention in recent years due to their distinct optical, thermal, and mechanical properties compared to other carbon nanomaterials (e.g., graphene, carbon nanotubes, carbon dots). Combined with a high surface-to-volume ratio and tunable and chemically versatile surfaces, these support broad applications across catalysis, electronics, and life sciences. Moreover, the biocompatible characteristics of NDs enable their controllable interfacial interactions with biological systems, positioning them as excellent candidates for advancing cutting-edge biomedical sciences, particularly through the engineering of efficient material-biointerfaces that facilitate optimal interactions with biological systems. Among various forms of NDs, fluorescent nanodiamonds (FNDs) have emerged as some of the most impactful and rapidly advancing materials, demonstrating strong potential in ultrasensitive spin-enhanced bioimaging, high-precision biosensing, traceable drug delivery, and quantum-enabled biomedical technologies. This Perspective introduces the key principles underlying NDs and FNDs, including their structural properties, synthesis methods, and surface functionalization strategies. It also highlights emerging biomedical applications of NDs and FNDs, with particular emphasis on neurological disorders. Last, the article discusses current challenges in advancing NDs as a multifunctional platform for neural therapies with translational potential toward clinical trials.

36 MATERIALS SCIENCE↗

A novel tool for improving the data collection process during control room modernization human-system interface testing and evaluation activities - 271

The U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program is developing a scientific basis to extend the existing U.S. nuclear power plant (NPP) operating life beyond the current 60-year licensing period and to ensure NPP long-term reliability, productivity, safety, and security. Under the Advanced Instrumentation, Information, and Control (II and C) Systems Technologies pathway, the LWRS Program conducts targeted research and development to address long-term aging and obsolescence of existing instrumentation and control technologies, as well as to implement and test new digital II and C technology that enables broad innovation and business improvement in the NPP operating model. To this end, the role of human factors engineering (HFE) is important as part of ensuring that the control room modernization (CRM) activities account for the operator's cognitive and physiological characteristics. Part of the HFE process for CRM entails conducting tests and evaluations (T and Es) that will inform the design of new human-system interface (HSI) technologies. Qualitative data that captures operator feedback and important human-system interactions are an important part of T and E. However, the analyzing this qualitative data in order to provide actionable design recommendations can be time-consuming and error prone. This paper presents an early version of a tool, which uses a combination of natural language processing and supervised machine learning to support the analysis of qualitative data. The objectives of this tool is to improve the process of (1) sifting through freeform text for improved design issue identification, (2) maintaining consistency in theme coding conventions, and (3) readily providing actionable design guidance that can be traceable to state-of-the-art HFE guidelines such as NUREG-0700. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurements of thermophysical properties of solids at the Institute VINČA

This paper presents the Metrological Laboratory for Thermophysical Quantities (MLTV) and its actual measurement possibilities. The MLTV is located in the Department of Thermal Engineering and Energy of the Institute of Nuclear Sciences VINČA in Serbia. It was founded in 1963, accredited by the National Accreditation Body in 2007 and became the national designated laboratory for thermophysical quantities and received the status of a EURAMET Associate Member in 2015. Today, the laboratory develops, maintains and disseminates traceability of different national standards, such as those for thermal conductivity of insulations and poorly conductive solid materials from 250 K to 350 K, thermal diffusivity of a large variety of solid materials from 200 K to 1450 K and specific heat and specific electrical resistivity from 250 K to 2400 K of electroconductive solid materials. Total hemispherical and spectral normal emissivity from 1200 K to 2400 K of electroconductive solid materials are also measured in the MLTV. The methods and experimental setups for the realization and measurement of all of these standards and quantities are described with corresponding examples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrastable low-noise current amplifier: A novel device for measuring small electric currents with high accuracy

An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current gain and the second performing a current-to-voltage conversion via an internal 1 MΩ reference resistor or, optionally, an external standard resistor. The ULCA’s transfer coefficient is highly stable versus time, temperature, and current amplitude within the full dynamic range of ±5 nA. The low noise level of 2.4 fA/√Hz helps to keep averaging times short at small input currents. A cryogenic current comparator is used to calibrate both input current gain and output transresistance, providing traceability to the quantum Hall effect. Within one week after calibration, the uncertainty contribution from short-term fluctuations and drift of the transresistance is about 0.1 parts per million (ppm). The long-term drift is typically 5 ppm/yr. A high-accuracy variant is available that shows improved stability of the input gain at the expense of a higher noise level of 7.5 fA/√Hz. The ULCA also allows the traceable generation of small electric currents or the calibration of high-ohmic resistors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

input4MIPs: Making [CMIP] model forcing more transparent

Here, the new input4MIPs initiative to collect, archive and document CMIP6 "forcing" datasets facilitates modeling groups to generate climate simulations of the past, present and future. Better provenance and comprehensive documentation will improve consistency, reproducibility, and traceability of model results moving forward.

54 ENVIRONMENTAL SCIENCES↗

Report of the 2026 Workshop on Next-Generation Ecosystems for Scientific Computing: Harnessing Community, Software, and AI for Cross-Disciplinary Team Science

Scientific computing is undergoing rapid transformation as advances in artificial intelligence, heterogeneous computing, automation, and data-intensive research reshape not only computational tools but also the institutions, workforce models, and collaborative practices that support scientific discovery. This report synthesizes insights from the 2026 Workshop on Next-Generation Ecosystems for Scientific Computing, the second in a three-year series focused on strengthening scientific computing ecosystems through socio-technical co-design. Workshop discussions identified four interdependent strategic themes: software ecosystems for AI-enabled scientific discovery; trust, validation, and traceability; human-AI teaming and paradigm shifts; and workforce, pedagogy, and governance. The report translates these themes into eight priorities for community action spanning shared research infrastructure, trust and traceability, user experience, human-AI teaming, workforce development, cross-sector coordination, stewardship and sustainability, and evaluation of scientific value. Together, these priorities outline directions for building scientific computing ecosystems that remain trustworthy, sustainable, innovative, and resilient as AI assumes a growing role in scientific work.

AI↗

Version 4 of the CRU TS monthly high-resolution gridded multivariate climate dataset

CRU TS (Climatic Research Unit gridded Time Series) is a widely used climate dataset on a 0.5° latitude by 0.5° longitude grid over all land domains of the world except Antarctica. It is derived by the interpolation of monthly climate anomalies from extensive networks of weather station observations. Here we describe the construction of a major new version, CRU TS v4. It is updated to span 1901–2018 by the inclusion of additional station observations, and it will be updated annually. The interpolation process has been changed to use angular-distance weighting (ADW), and the production of secondary variables has been revised to better suit this approach. This implementation of ADW provides improved traceability between each gridded value and the input observations, and allows more informative diagnostics that dataset users can utilise to assess how dataset quality might vary geographically.

54 ENVIRONMENTAL SCIENCES↗

SI traceable calibration of an instrumented indentation sensor spring constant using electrostatic force

We present a measurement scheme for creating reference electrostatic forces that are traceable to the International System of Units. This scheme yields reference forces suitable for calibrating the force sensitivity of instrumented indentation machines and atomic force microscopes. Forces between 10 and 200 {mu}N were created and expressed in terms of the voltage, length, and capacitance between a pair of interacting electrodes. The electrodes comprised an electrically conductive sphere mounted as a tip on an instrumented indentation sensor, and a planar counterelectrode fixed to a sample stage in close proximity to the sphere. For comparison, we applied mechanical forces of similar magnitudes, first using deadweights and then using a reference force sensor. The deflection of the sensor due to the various applied forces was measured using an interferometer. A spring constant for the sensor was computed from the observed records of force versus displacement. Each procedure yielded a relative standard uncertainty of approximately 1%; however, the electrostatic technique is scalable and could provide traceable reference forces as small as a few hundred piconewtons, a range far below anything yet achieved using deadweights.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new facility for the synchrotron radiation-based calibration of transfer radiation sources in the ultraviolet and vacuum ultraviolet spectral range

The Physikalisch-Technische Bundesanstalt (PTB) has a long tradition in the calibration of radiation sources in the ultraviolet and vacuum ultraviolet spectral range, with traceability to calculable synchrotron radiation. Within this context, new instrumentation in the PTB laboratory at the Metrology Light Source (MLS) has been put into operation that opens up extended and improved calibration possibilities. A new facility for radiation source calibrations has been set up in the spectral range from 7 nm to 400 nm based on a combined normal incidence-grazing incidence monochromator. The facility can be used for the calibration of transfer sources in terms of spectral radiant intensity or mean spectral radiance, with traceability to the MLS primary source standard. We describe the design and performance of the experimental station and give examples of some commissioning results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating Radiative Closure in the Middle-to-Upper Troposhere

This project had two general objectives. The first is the characterization and improvement of the radiative transfer parameterization in strongly absorbing water vapor bands, as these strongly absorbing bands dictate the clear sky radiative heating rate. The second is the characterization and improvement of the radiative transfer in cirrus clouds, with emphasis on ensuring that the parameterization of the radiative transfer is consistent and accurate across the spectrum. Both of these objectives are important for understanding the radiative processes in the mid-to-upper troposphere. The research on this project primarily involved analysis of data from the First and Second Radiative Heating in Underexplored Bands Campaigns, RHUBC-I and II. This included a climate model sensitivity study using results from RHUBC-I. The RHUBC experiments are ARM-funded activities that directly address the objectives of this research project. A secondary effort was also conducted that investigated the trends in the long-term (~14 year) dataset collected by the Atmospheric Emitted Radiance Interferometer (AERI) at the ARM Southern Great Plains site. This work, which was primarily done by a post-doc at the University of Wisconsin, Madison under Dr. Turner's direction, uses the only NIST-traceable instrument at the ARM site that has a well-documented calibration and uncertainty performance to investigate long-term trends in the downwelling longwave radiance above this site.

54 ENVIRONMENTAL SCIENCES↗

Test case selection procedure for simulation-assisted automation testing - 321

Simulation-assisted automation testing is an efficient tool for validating the automation systems for nuclear power plants. This paper presented a systematic procedure for selecting test cases for simulation-assisted automation testing. The procedure is relies on the plant's licensing framework and allows associating the test cases to the functional requirements in order to produce traceable test set for validation. The procedure is demonstrated with a case study concerning the automation tests of Loviisa NPP's automation renewal project. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗