Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scattered collimator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A flexible neutron spectrometer concept with a new ultra-high field steady-state vertical-bore magnet

The proposed facility explores materials under ultra-high magnetic fields. By combining the power of high fields to tune materials and of neutron scattering to probe the resulting changes down to the atomic scale, this facility will enable transformative progress in the study of quantum materials and is named for the “TITAN” subset of Greek gods to reflect this transformation. TITAN will offer DC magnetic fields up to at least 20 T. Exploiting the record brightness and bandwidth of the Second Target Station at the Spallation Neutron Source, TITAN will probe atomic-scale responses through high efficiency neutron spectroscopy up to 80 meV energy transfer, high resolution diffraction, and small angle neutron scattering. Focusing neutron optics will maximize flux on accurately positioned samples, while radial collimation and optimized shielding and detection strategies will minimize backgrounds.

47 OTHER INSTRUMENTATION↗

Shedding light on the MiniBooNE excess with searches at the LHC

The origin of the excess of low-energy events observed by the MiniBooNE experiment remains a mystery, despite exhaustive investigations of backgrounds and a series of null measurements from complementary experiments. One intriguing explanation is the production of beyond-the-Standard-Model particles that could mimic the experimental signature of additional ν e appearance seen in MiniBooNE. In one proposed mechanism, muon neutrinos up-scatter to produce a new “dark neutrino” state that decays by emitting highly collimated electron-positron pairs. We propose high-energy neutrinos produced from W boson decays at the Large Hadron Collider as an ideal laboratory to study such models. Simple searches for a low-mass, boosted dilepton resonance produced in association with a high- p T muon from the W decay with run 2 data would already provide unique sensitivity to a range of dark neutrino scenarios, with prompt and displaced searches providing complementarity. Looking farther ahead, we show how the unprecedented sample of W boson decays anticipated at the HL-LHC, together with improved lepton acceptance would explore much of the parameter space most compatible with the MiniBooNE excess. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First degraded beams in the CEBAF injector

The electron beam degrader in the Continuous Electron Beam Accelerator Facility (CEBAF) injector at Jefferson Lab serves to generate electron beams with transverse emittance over 10x the nominal values, with the ultimate goal of using degraded electron beams to measure machine acceptance. Electron beams are degraded through multiple scattering in thin carbon foils, and maximum transverse emittance is defined through two collimating apertures. The degrader device was installed in late 2024, with commissioning and first beams on degrader targets during the 2025 physics run. We report on first operation of the degrader device. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177.

Sy, A. [Thomas Jefferson National Accelerator Faci↗

Coherent backscatter and the radar characteristics of outer planet satellites

It is presently suggested that the diffuse component-dominated high radar reflectivities and large polarization of Europa, Ganymede, and Callisto could be due to the illumination by a collimated source of a weakly absorbing particulate medium in which wavelength-scaled scatterers are separated by distances somewhat larger than the wavelength. A plausible medium could be a regolith composed of voids and/or silicate rocks imbedded in an icy matrix; multiply-scattered parts of the wavefront traversing the same path in opposite directions combine coherently in the backscatter direction to generate increased intensity, and the enhancement is different for the two components of polarized reflected radiation.

Hapke, Bruce↗

A Flat Analyzer Polycapillary Spectrometer for X-ray Absorption Spectroscopy of Dilute Transition Metals at X-ray-Free Electron Lasers

X-ray absorption spectroscopy (XAS) coupled with highly intense pulses from an X-ray-free electron laser (XFEL) can be used to track ultrafast chemical dynamics. Nonetheless, measurements for dilute samples (≤1 mM) have been exceptionally challenging, as scattering background signals dominate over the sample’s X-ray fluorescence. We show that femtosecond time-resolved XAS measurements of sub-millimolar transition metal solutions are now possible at the Linac Coherent Light Source (LCLS) using a high-throughput polycapillary XAS spectrometer, designed, developed, and commissioned at LCLS and the Stanford Synchrotron Radiation Lightsource (SSRL). The instrument integrates three polycapillary optics that collect and collimate X-ray fluorescence emitted from the interaction point with a high solid angle. X-ray collimated fluorescence is then selectively diffracted by coupled graphite analyzer crystals. As a result, the contribution of scattered photons is suppressed. Experiments at the Pt L 3 -edge on 0.1 mM aqueous K 2 PtCl 6 (delivered via a 100 μm liquid jet) were successfully performed in the laser pump X-ray probe configuration at the LCLS XCS and XPP instruments. We report the transient spectra of hexachloroplatinate within the first 10 ps after a 266 nm photoexcitation. We observed a short-lived reduced intermediate (≈2 ps). The polycapillary X-ray spectrometer at LCLS now enables the efficient study of the dynamics of ultradilute transition metals in solution. This capability opens the door to investigating plasmonic systems, photocatalysts, enzymes, and other scarce and dilute samples.

LCLS↗

Gamma-ray spectroscopy using angular distribution of Compton scattering

We present a novel method to perform gamma-ray spectroscopy suitable for extreme pileup situations, wherein traditional pulse-height spectroscopy is infeasible or impractical. One example of such application is spectral characterization of intense laser-based radiation sources that employ laser wakefield acceleration, in which a large number of photons can be produced in a well-collimated beam on a picosecond or shorter timescale. The method relies on the angularly-resolved calorimetric measurement of Compton scattering. The probability for a photon to undergo Compton scattering into a given solid angle is a function of its energy and is described by the Klein–Nishina formula. By first Compton scattering the incident beam and then measuring the total energies deposited in multiple detectors placed at various scattering angles, the incident beam energy spectrum can be reconstructed without resolving the individual events in detectors. Here, we compare the performance of an maximum likelihood expectation maximization algorithm with that of an artificial neural network to measure the energy spectrum of a beam of monoenergetic gamma rays from 137Cs decay. We demonstrate that the method can be used to reconstruct the characteristic inverse Compton scattering spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effects of radiation drag on radial, relativistic hydromagnetic winds

The effects of drag on an idealized relativistic MHD wind of radial geometry are studied. The astrophysical motivation is to understand the effects of radiation drag on the dynamics of a jet or wind passing through the intense radiation field of an accreting compact object. From a critical point analysis, it is found that a slow magnetosonic point can appear in a dragged flow even in the absence of gravitational force, as a result of a balance between the drag force and the combination of thermal pressure and centrifugal forces. As in the undragged case, the Alfven point does not impose any constraints on the flow. Although it is formally possible for a dragged flow to possess more than one fast magnetosonic point, it is shown that this is unlikely in practice. In the limit of a 'cold', centrifugally driven flow, it is shown that the fast magnetosonic point moves to infinite radius, just as in the drag-free case. For a given mass flux, the total energy output carried to infinity, and the final partition between the kinetic energy and the Poynting flux, are the same for the dragged and the drag-free flows. The main effects of radiation drag are to increase the amount of energy and angular momentum extracted from the source and to redistribute the regions where acceleration occurs in the flow. This is accomplished through the storage and release of magnetic energy, as a result of additional winding and compression of the field caused by the action of the drag. For a relativistic wind, the dissipated energy can exceed the final kinetic energy of the flow and may be comparable to the total flow energy (which is dominated by Poynting flux). The energy lost to radiation drag will appear as a Doppler-boosted beam of scattered radiation, which could dominate the background radiation if the flow is well-collimated.

Li, Zhi-Yun↗

Conically Scanned Holographic LIDAR Telescope

Holographic LIDAR telescope includes holographic disk, rotation of which sweeps collimated, monochromatic beam of light from laser through conical scan. Holographic disk diffracts light scattered back from target volume or area to focal point located at stationary photomultiplier detector. Two conical baffles prevent stray light from reaching detector.

Schwemmer, Geary↗

Space shuttle molecular and wake vacuum measurements

The wake environment of the space shuttle is analyzed to determine whether it is feasible to perform ultrahigh vacuum experiments in or near the payload bay with the shuttle oriented such that the payload bay faces the antivelocity direction. Several mechanisms were considered by which molecules could approach the payload bay from this direction and their relative contributions to the wake environment are estimated. These mechanisms include ambient atmospheric molecules that have velocities in excess of the orbital velocity which can overtake the shuttle, ambient atmospheric molecules that are backscattered by collisions with the shuttle induced atmosphere, and self scattering from the induced atmosphere. These estimates are compared with the measurements made with the collimated mass spectrometer which was part of the Induced Environment Contamination Monitor flown on several of the early shuttle flights. Although the collimated mass spectrometer was not designed for this purpose and the instrument background for the species for which the collimator is effective is above the expected levels, upper limits can be established for these species in the wake environment which are consistent with the analysis. There was considerably more helium and argon observed in the wake direction than was predicted, however. Possible origins of these gases are discussed.

Naumann, R. J.↗

Spectral variation of scattering and absorption by cirrus

The impact of cirrus clouds on the radiative budget of the earth depends on the microphysics and scattering properties of the clouds. Cirrus clouds have been especially difficult to observe because of their high altitude and complex tenuous structure. Observations by Abakumova et. al. (1991) show that the near infrared wavelengths are more sensitive to the cirrus cloud properties than the shorter ultraviolet wavelengths. Anikin (1991) was able to show that collimated spectral measurements can be used to determine an effective particle size of the cirrus clouds. Anikin (1991) also showed that the effect of scattering through cloud causes the apparent optical depth of a 10 degrees field of view pyrheliometer to be roughly half the actual optical depth. Stackhouse and Stephens (1991) have shown that the existence of small ice crystals do dramatically affect the radiative properties of the cirrus, though observations taken during the 1986 FIRE were not totally explained by their presence.

Hein, Paul F.↗

Mariner 10 ultraviolet spectrometer - Airglow experiment

An extreme ultraviolet airglow spectrometer was flown on Mariner 10 to examine the atmosphere of Venus and Mercury. An objective grating spectrometer was used with channel electron multipliers at fixed positions in the image plane to continuously monitor the resonance-scattered emission rate of expected atomic atmospheric constituents He, H, A, Ne, O and C. A mechanical collimator placed in the entrance aperture of the spectrometer provided spectral separation of 19 A over the wavelength range from He/+/ at 304 A to C at 1657 A and provided spatial separation of 0.125 deg consistent with the spacecraft and trajectory capabilities. The calibration techniques are discussed.

Broadfoot, A. L.↗

Measurement of Two-Point Energy Correlators within Jets in 𝑝 + 𝑝 Collisions at $\sqrt{𝑠}$ = 200 GeV

Hard-scattered partons ejected from high-energy proton-proton collisions undergo parton shower and hadronization, resulting in collimated collections of particles that are clustered into jets. A substructure observable that highlights the transition between the perturbative and nonperturbative regimes of jet evolution in terms of the angle between two particles is the two-point energy correlator (EEC). In this Letter, the first measurement of the EEC at RHIC is presented, using data taken from 200 GeV 𝑝 + 𝑝 collisions by the STAR experiment. The EEC is measured both for all the pairs of particles in jets and separately for pairs with like and opposite electric charges. These measurements demonstrate that the transition between perturbative and nonperturbative effects occurs within an angular region that is consistent with expectations of a universal hadronization regime that scales with jet momentum for a given initiator flavor. Additionally, a deviation from Monte Carlo predictions at small angles in the charge-selected sample could result from mechanics of hadronization not fully captured by current models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ACRRF High-Bay Dose Calculations using MCNP (Part A)

Analytical tools and models have been developed as a starting point for directly assessing dose in the Annular Core Research Reactor Facility (ACRRF) due to reactor operation. Key results include peak dose along the Central Cavity (CC) centerline (beamline) at the cavity level, dose throughout the High-Bay (HB), and dose on the facility roof for partially-shielded reactor operation where the 4” insert is removed from the CC Shield Plug (SP). Model results in the beamline are benchmarked against measured doses from passive dosimetry evaluations. Personnel total (neutron and gamma) dose in the ACRRF HB is calculated using Monte Carlo N-Particle (MCNP). Various CC and SP configurations are analyzed, including unshielded (no SP) and partially shielded (SP installed but 4” insert removed). Novel application of Variance Reduction (VR) techniques, namely the Surface Source Write (SSW) and Surface Source Read (SSR) capabilities in MCNP, enable impressive resolution (in a Monte Carlo modeling sense) of dose throughout much the facility. The VR techniques reduce stochastic error for challenging tallies, with more advanced techniques explored in the companion to this report (Part B) [1]. Supplementary studies (including a verification analysis) and pedagogic evaluations in Part B involve neutron spectra, angular distributions, and the dose impact of facility characteristics. With the SP 4” insert removed and the Lead-Boron (44”) Bucket (LB–44) in the reactor cavity, Total Effective Dose (TED) within the CC beamline is ≈140 rem per 300 MJ of reactor yield (or 3900 rem per hour at 100% Steady-State (SS) power). With no SP (unshielded) and a Free-Field (FF) cavity, TED within the beamline is ≈610 rem per 300 MJ (or 17000 rem per hour at 100% SS power). Due to the predicted collimation of radiation by the reactor pool (and partial SP, if present), beamline dose is much greater than the scattered radiation field surrounding the cavity and reactor tank. Comparisons are made to beamline dosimetry measurements to validate the model. Model predictions agree reasonably well (⪅10%) with measured quantities of neutron fluence, gamma fluence, and spectral metrics. Away from the beamline, comparisons made to previous dose measurements in the HB agreement within an order of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nephelometer evaluation for measurement of cloud parameters in earth and planetary atmospheres

Initial work was concerned with determining whether the radiation emitted from a laser source could be sufficiently collimated to provide a suitable source for a nephelometer-type instrument. It was necessary to develop a standard scatterer that could be used to evaluate the performance of a nephelometer. The possible use of a gallium arsenide diode as a radiation source also was investigated. The first of these utilized a single lens to focus the light scattered from a target onto a ring detector. The second configuration used reflecting and refracting axicons as optical-system elements. The work performed in each of these areas is described.

Ballard, G. S.↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope Observatory, the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

Probing early parton emissions in heavy ion collisions using the Lund jet plane

In scattering experiments, high-virtuality partons, i.e., quarks and gluons, initiate a series of additional parton emissions to create collimated sprays of particles known as jets. This paper presents a measurement of the Lund jet plane (LJP) of high-energy jets produced in lead-lead (PbPb) collisions and compares the results to data for proton-proton (pp) collisions. The LJP is formed by iteratively declustering the constituents of a jet into consecutive emissions and recording the relative transverse momentum ($k_\mathrm{T}$) and angle of the resulting emission with respect to its emitter. The angular distributions of two different $k_\mathrm{T}$ slices of the LJP are investigated for jets with radius parameter of 0.4 and transverse momentum in the range 200$-$1000 GeV. The PbPb (pp) data were recorded by the CMS experiment in 2018 (2017) and correspond to an integrated luminosity of 1.7 nb$^{-1}$ (301 pb$^{-1}$) at a nucleon-nucleon center-of-mass energy of 5.02 TeV. The measurement was designed to test whether the earliest jet emissions are produced before the formation of the quark-gluon plasma (QGP) in PbPb collisions. Within the experimental uncertainties, no significant difference is observed between the angular distribution of high-$k_\mathrm{T}$ emissions in \pp and PbPb collisions, which is consistent with these emissions occurring early in the jet evolution, before substantial interaction with the QGP.

Belyaev, Andrey [Yerevan Phys. Inst.] (ORCID:00000↗

Generation of collimated vortex gamma-rays from intense Poincaré beam–plasma interaction

We report on numerical calculations in which a multi-petawatt γ-ray beam is generated using a novel configuration based on fully structured light irradiating an overdense plasma waveguide. We analyze how the relativistic laser pulse efficiently confines and accelerates plasma electrons to GeV-scale energies and drives a quasi-static field that induces magneto-bremsstrahlung radiation. Multiphoton Compton scattering of electrons in the intense part of the laser also occurs although the radiated energy-density is comparatively lower. The emitted γ-rays carry orbital angular momentum, are highly collimated, and account for upwards of 15% of the incident field energy in one particular case. A comparison of the laser-to-particle angular momentum and energy transfer efficiencies is made between the cases of irradiation by a circularly polarized Laguerre–Gauss mode and one type of full Poincaré beam, and it is found that the latter yields an order-of-magnitude enhancement. In conclusion, the essential characteristics of the interaction are validated with three-dimensional particle-in-cell simulations that include quantum electrodynamical effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗