Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scanning mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Reactive sputter magnetron reactor for preparation of thin films and simultaneous in situ structural study by X-ray diffraction

The purpose of the designed reactor is (i) to obtain polycrystalline and/or amorphous thin films by controlled deposition induced by a reactive sputtering magnetron and (ii) to perform a parallel in situ structural study of the deposited thin films by X-ray diffraction, in real time, during the whole growth process. The designed reactor allows for the control and precise variation of the relevant processing parameters, namely, magnetron target-to-sample distance, dc magnetron voltage, and nature of the gas mixture, gas pressure and temperature of the substrate. On the other hand, the chamber can be used in different X-ray diffraction scanning modes, namely, {theta}-2{theta} scanning, fixed {alpha}-2{theta} scanning, and also low angle techniques such as grazing incidence small angle X-ray scattering and X-ray reflectivity. The chamber was mounted on a standard four-circle diffractometer located in a synchrotron beam line and first used for a preliminary X-ray diffraction analysis of AlN thin films during their growth on the surface of a (100) silicon wafer.

36 MATERIALS SCIENCE↗

Detection of an atmosphere around the super-earth 55 Cancri e

We report the analysis of two new spectroscopic observations in the near-infrared of the super-Earth 55 Cancri e, obtained with the WFC3 camera on board the Hubble Space Telescope. 55 Cancri e orbits so close to its parent star that temperatures much higher than 2000 K are expected on its surface. Given the brightness of 55 Cancri, the observations were obtained in scanning mode, adopting a very long scanning length and a very high scanning speed. We use our specialized pipeline to take into account systematics introduced by these observational parameters when coupled with the geometrical distortions of the instrument. We measure the transit depth per wavelength channel with an average relative uncertainty of 22 ppm per visit and find modulations that depart from a straight line model with a 6σ confidence level. These results suggest that 55 Cancri e is surrounded by an atmosphere, which is probably hydrogen-rich. Our fully Bayesian spectral retrieval code, T-REx, has identified HCN to be the most likely molecular candidate able to explain the features at 1.42 and 1.54 μm. While additional spectroscopic observations in a broader wavelength range in the infrared will be needed to confirm the HCN detection, we discuss here the implications of such a result. Our chemical model, developed with combustion specialists, indicates that relatively high mixing ratios of HCN may be caused by a high C/O ratio. This result suggests this super-Earth is a carbon-rich environment even more exotic than previously thought.

79 ASTRONOMY AND ASTROPHYSICS↗

hsrlscan.a1

High Spectral Resolution Lidar Scanning Mode

54 ENVIRONMENTAL SCIENCES↗

A study approach on ferroelectric domains in BaTiO{sub 3}

Atomic Force Acoustic Microscopy (AFAM) and Piezoresponse Force Microscopy (PFM) were used to study local elastic and electromechanical response in BaTiO{sub 3} ceramics. A commercial multi-mode Scanning Probe Microscopy (SPM) and AFAM mode to image contact stiffness were employed to accomplish the aforementioned purposes. Stiffness parameters along with Young's moduli and piezo coefficients were quantitatively determined. PFM studies were based on electrostatic and electromechanical response from localized tip-surface contact. Comparison was made regarding the Young's moduli obtained by AFAM and PFM. In addition, phase and amplitude images were analyzed based on poling behavior, obtained via the application of − 10 V to + 10 V local voltage. - Highlights: •Nanoscale behavior of piezo domains in BaTiO{sub 3} ferroelectric materials •Use of Atomic Force Acoustic Microscopy (AFAM) and Piezo Force Microscopy (PFM) •Local elastic and electromechanical response in BaTiO{sub 3} ceramics •The young's moduli obtained from AFAM and PFM.

36 MATERIALS SCIENCE↗

A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source

A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend). This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 {mu}m spot of {approx}5x10{sup 9} photons/s (0.1% bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored by two pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick-Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 {mu}m are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution ({approx}0.2 {mu}m) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5x10{sup -5} strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution ({approx}150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verification of Gamma Knife extend system based fractionated treatment planning using EBT2 film

Purpose: This paper presents EBT2 film verification of fractionated treatment planning with the Gamma Knife (GK) extend system, a relocatable frame system for multiple-fraction or serial multiple-session radiosurgery.Methods: A human head shaped phantom simulated the verification process for fractionated Gamma Knife treatment. Phantom preparation for Extend Frame based treatment planning involved creating a dental impression, fitting the phantom to the frame system, and acquiring a stereotactic computed tomography (CT) scan. A CT scan (Siemens, Emotion 6) of the phantom was obtained with following parameters: Tube voltage—110 kV, tube current—280 mA, pixel size—0.5 × 0.5 and 1 mm slice thickness. A treatment plan with two 8 mm collimator shots and three sectors blocking in each shot was made. Dose prescription of 4 Gy at 100% was delivered for the first fraction out of the two fractions planned. Gafchromic EBT2 film (ISP Wayne, NJ) was used as 2D verification dosimeter in this process. Films were cut and placed inside the film insert of the phantom for treatment dose delivery. Meanwhile a set of films from the same batch were exposed from 0 to 12 Gy doses for calibration purposes. An EPSON (Expression 10000 XL) scanner was used for scanning the exposed films in transparency mode. Scanned films were analyzed with inhouse written MATLAB codes.Results: Gamma index analysis of film measurement in comparison with TPS calculated dose resulted in high pass rates >90% for tolerance criteria of 1%/1 mm. The isodose overlay and linear dose profiles of film measured and computed dose distribution on sagittal and coronal plane were in close agreement.Conclusions: Through this study, the authors propose treatment verification QA method for Extend frame based fractionated Gamma Knife radiosurgery using EBT2 film.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Cloud-Tracking Data Set for the CSAPR2 Adaptive Scanning during TRACER

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility (Mather and Voyles 2013) deployed the first ARM Mobile Facility (AMF1; Miller et al. 2016) near LaPorte, Texas to support the Tracking Aerosol Convection Interactions Experiment (TRACER) (Jensen et al. 2025) near Houston, Texas. From October 2021 to September 2022, AMF1 was deployed to 29.67° N, 95.06° W near LaPorte, Texas and the 2nd Generation C-band Scanning ARM Precipitation Radar (CSAPR2) was deployed to a supplementary site at 29.53° N, 95.28° W (Figure 1). During an intensive operational period (IOP) from 1 June to 30 September 2022, the CSAPR2 sampled precipitation echoes in an adaptive scanning mode following the Multisensor Agile Adaptive Scanning (MAAS) framework (Kollias et al. 2020). MAAS helped optimize the CSAPR2 scan strategy to perform frequent plan position indicator (PPI) and range height indicator (RHI) scans (Lamer et al. 2023). Details of the CSAPR2 scanning, data processing, and calibration procedures used by the principal investigator (PI), and the PI data files are described by Oue et al. (2023). Details of the CSAPR2 operational performance, ARM data processing and correction procedures, and data quality masks are described by Feng et al. (2024a).

54 ENVIRONMENTAL SCIENCES↗

Laser absorption measurements of OH concentration and temperature in pulsed facilities

A laser absorption flow diagnostic application has been developed at the NASA Ames 16-inch Shock Tunnel for purposes of measuring the thermochemical state of OH in flow environments of interest. Research objectives include the investigation of high temperature, low pressure chemistry pertinent to scramjet combustors and high altitude flight. The system can be operated in either the fixed frequency mode or in the rapid wavelength scanning mode to measure species mole fraction and temperature. Emission diagnostics have been employed to determine shock tunnel flow quality and assist in the proper application of the diagnostic and its data interpretation. Rotational lines in the OH system were probed in the expanding facility nozzle flow, and time-resolved measurements of temperature and mole fraction are provided.

Cavolowsky, John A.↗

A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source

A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend) This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 mu m spot of ~;;5x109 photons/ s (0.1percent bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored bytwo pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick-Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 um are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution (~;;0.2 mu m) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5x10-5 strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution (~;;150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.

47 OTHER INSTRUMENTATION↗

Testicular Doses in Image-Guided Radiotherapy of Prostate Cancer

Purpose: To investigate testicular doses contributed by kilovoltage cone-beam computed tomography (kVCBCT) during image-guided radiotherapy (IGRT) of prostate cancer. Methods and Materials: An EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions from kVCBCT on 3 prostate cancer patients. Absorbed doses to various organs were compared between intensity-modulated radiotherapy (IMRT) treatments and kVCBCT scans. The impact of CBCT scanning mode, kilovoltage peak energy (kVp), and CBCT field span on dose deposition to testes and other organs was investigated. Results: In comparison with one 10-MV IMRT treatment, a 125-kV half-fan CBCT scan delivered 3.4, 3.8, 4.1, and 5.7 cGy to the prostate, rectum, bladder, and femoral heads, respectively, accounting for 1.7%, 3.2%, 3.2%, and 8.4% of megavoltage photon dose contributions. However, the testes received 2.9 cGy from the same CBCT scan, a threefold increase as compared with 0.7 cGy received during IMRT. With the same kVp, full-fan mode deposited much less dose to organs than half-fan mode, ranging from 9% less for prostate to 69% less for testes, except for rectum, where full-fan mode delivered 34% more dose. As photon beam energy increased from 60 to 125 kV, kVCBCT-contributed doses increased exponentially for all organs, irrespective of scanning mode. Reducing CBCT field span from 30 to 10 cm in the superior-inferior direction cut testicular doses from 5.7 to 0.2 cGy in half-fan mode and from 1.5 to 0.1 cGy in full-fan mode. Conclusions: Compared with IMRT, kVCBCT-contributed doses to the prostate, rectum, bladder, and femoral heads are clinically insignificant, whereas dose to the testes is threefold more. Full-fan CBCT usually deposits much less dose to organs (except for rectum) than half-fan mode in prostate patients. Kilovoltage CBCT-contributed doses increase exponentially with photon beam energy. Reducing CBCT field significantly cuts doses to testes and other organs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatial Characterization of PACE OCI ETU Using Time-Delay Mode

The OCI (Ocean Color Instrument) is the main sensor on the upcoming PACE (Plankton Aerosol Cloud ocean Ecosystem) mission. OCI has two hyperspectral CCD sensors covering 340nm to 885nm and 9 SWIR (Short Wave IR) bands from 940nm to 2260nm. SWIR bands have nominal 1km ground pixel size and CCD bands have native 1/8 km ground pixel size in diagnostic mode that will be aggregated into 1km pixels to improve SNR and meet the data rate constraints. OCI has a rotating telescope that is synchronized to the readout of the CCD and SWIR detectors. Full pre-launch system level testing for the OCI ETU (Engineering Test Unit) was completed in June 2021.With time-delayed scan mode, a sub-pixel level time-delay step is applied to the detector readout. This sub-pixel level time-delay step causes a sub-pixel level shift in the start of the data collection. After collecting time-delay step scans with different step sizes, a scan profile with sub-pixel resolution can be constructed. 1/8 and 1/4 of CCD pixel resolutions were achieved using this mode. In this paper, the OCI time-delayed scan mode will be described as well as how it was used to calculate OCI’s high spatial resolution PSF (Point Spread Function), IFOV (instantaneous Field of View), MTF (Modulation Transfer Function), and BBR (Band to Band Registration).

PACE↗

Effect of jaw size in megavoltage CT on image quality and dose

Purpose: Recently, the jaw size for the TomoTherapy Hi-Art II{sup Registered-Sign} (TomoTherapy Inc., Madison, WI) was reduced from 4 mm (J4) to 1 mm (J1) to improve the longitudinal (IEC-Y) resolution in megavoltage computed tomography (MVCT) images. This study evaluated the effect of jaw size on the image quality and dose, as well as the dose delivered to the lens of the eye, which is a highly radiosensitive tissue. Methods: MVCT image quality (image noise, uniformity, contrast linearity, high-contrast resolution, and full width at half-maximum) and multiple scan average dose (MSAD) were measured at different jaw sizes. A head phantom and photoluminescence glass dosimeters (PLDs) were used to measure the exposed lens dose (cGy). Different MVCT scan modes (pitch = 1, 2, and 3) and scan lengths (108 mm, 156 mm, and 204 mm) were applied in the MSAD and PLDs measurements. Results: The change in jaw size from J4 to J1 produced no change or only a slight improvement in image noise, uniformity, contrast linearity, and high-contrast resolution. However, the full-width at half-maximum reduced from approximately 7.2 at J4 to 4.5 mm at J1, which represents an enhancement in the longitudinal resolution. The MSAD at the center point changed from approximately 0.69-2.32 cGy (peripheral: 0.83-2.49 cGy) at J4 to 0.85-2.81 cGy (peripheral: 1.05-2.86 cGy) at J1. The measured lens dose increased from 0.92-3.36 cGy at J4 to 1.06-3.91 cGy at J1. Conclusions: The change in jaw size improved longitudinal resolution. The MVCT imaging dose of approximately 3.86 cGy, 1.92 cGy, and 1.22 cGy was delivered at a pitch of 1, 2, and 3, respectively, per fraction in the head and neck treatment plans. Therefore, allowance for an approximately 15% increase in lens dose over that with J4 should be provided with J1.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Dark World: A Tale of WASP-43b in Reflected Light with HST WFC3/UVIS

Optical reflected light eclipse observations provide a direct probe of exoplanet scattering properties, such as from aerosols. We present here the photometric reflected light observations of WASP-43b using the Hubble Space Telescope (HST) WFC3/UVIS instrument with the F350LP filter (346–822 nm) encompassing the entire optical band. This is the first reflected light photometric eclipse using UVIS in scanning mode; as such, we further detail our scanning extraction and analysis pipeline Arctor. Our HST WFC3/UVIS eclipse light curve for WASP-43b derived a 3σ upper limit of 67 ppm on the eclipse depth, which implies that WASP-43b has a very dark dayside atmosphere. With our atmospheric modeling campaign, we compared our reflected light constraints with predictions from global circulation and cloud models benchmarked with HST and Spitzer observations of WASP-43b. We infer that we do not detect clouds on the dayside within the pressure levels probed by HST WFC3/UVIS with the F350LP filter (P > 1 bar). This is consistent with the general circulation model predictions based on previous WASP-43b observations. Dayside emission spectroscopy results from WASP-43b with HST and Spitzer observations are likely to not be significantly affected by contributions from cloud particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Minimum acquisition time detection

Two different methods of target detection when the return signal is contaminated with noise are discussed and compared. The first method uses Neyman-Pearson detection philosophy and selects the threshold level to give a desired false alarm probability. The maximum probability of false alarm is constrained by the target cross scan velocity component. The second method (minimum acquisition time detection), which is similar to the ideal observer, selects the threshold level to minimize the expected target acquisition time. The probabilities of false alarm and missed detection are selected so that the errors produced by these effects produce the minimum acquisition time. Three different scan techniques - linear, spiral and two-mode scan - are studied and compared.

Brock, H. I.↗

Remote sensing using solid-state array technology

The paper describes the design features and capabilities of a remote sensor that uses solid-state linear arrays and operates in a 'pushbroom' scan mode to provide the required performance. Pushbroom scanning is a term describing the technique of using the forward motion of a satellite platform to sweep a linear array of detectors oriented perpendicular to the ground track across a scene being imaged. One array is typically used for each spectral channel. Satellite motion provides one direction of scan and electronic sampling of the detectors in the crosstrack dimension provides the orthogonal scan component to form an image. The detector array is sampled at the appropriate rate so that contiguous lines are produced. The performance of a pushbroom system is discussed relative to radiometric sensitivity, detector array geometric fidelity, and radiometric correction. System advantages are precision geometric positioning of the detectors, very high sensitivity and favorable SNR, low power consumption, and no moving optics.

Thompson, L. L.↗

Prompt Gamma Imaging for In Vivo Range Verification of Pencil Beam Scanning Proton Therapy

Purpose: To report the first clinical results and value assessment of prompt gamma imaging for in vivo proton range verification in pencil beam scanning mode. Methods and Materials: A stand-alone, trolley-mounted, prototype prompt gamma camera utilizing a knife-edge slit collimator design was used to record the prompt gamma signal emitted along the proton tracks during delivery of proton therapy for a brain cancer patient. The recorded prompt gamma depth detection profiles of individual pencil beam spots were compared with the expected profiles simulated from the treatment plan. Results: In 6 treatment fractions recorded over 3 weeks, the mean (± standard deviation) range shifts aggregated over all spots in 9 energy layers were −0.8 ± 1.3 mm for the lateral field, 1.7 ± 0.7 mm for the right-superior-oblique field, and −0.4 ± 0.9 mm for the vertex field. Conclusions: This study demonstrates the feasibility and illustrates the distinctive benefits of prompt gamma imaging in pencil beam scanning treatment mode. Accuracy in range verification was found in this first clinical case to be better than the range uncertainty margin applied in the treatment plan. These first results lay the foundation for additional work toward tighter integration of the system for in vivo proton range verification and quantification of range uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatial distribution of O(supra 1D) from Comet Halley

Images of Comet Halley in (OI)6300A emission obtained using a 150 mm Fabry-Perot spectrometer in the imaging mode were combined with spectra taken in the scanning mode to deduce the distribution of cometary O(1D) within a 10 arc min field of view centered on the comet head. The 10 km/sec bandpass of the system allows the distribution to be measured with little contamination from airglow O(1D) and cometary NH2 lines in the nearby spectrum. The results are modeled to provide photodestruction scale lengths for cometary H2O and OH, the predominant parents of O(1D). Results are compared with other experimental and theoretical results.

Roesler, F. L.↗

Spatial distribution of O(1D) from Comet Halley

Images of comet Halley in forbidden OI 6300-A emission obtained using a 150 mm Fabry-Perot spectrometer in the imaging mode were combined with spectra taken in the scanning mode to deduce the distribution of cometary O(1D) within a 10-arcmin field of view centered on the comet head. The 10-km/sec bandpass of the system allows the distribution to be measured with little contamination from airglow O(1D) and cometary NH2 lines in the nearby spectrum. The results are modeled to provide photodestruction scale lengths for cometary H2O and OH, the predominant parents of O(1D). Results are compared with other experimental and theoretical results.

Magee-Sauer, K.↗