Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Visual scanning behavior

This report summarizes the results and knowledge of scan behavior gained in various simulation and laboratory studies. Results were obtained through various analysis techniques such as real-time viewing of the pilot's scanning behavior and quantitative analysis of scan behavior performance parameters (average dwell time, dwell percentages, instrument transition paths, dwell histograms, and entropy rate measures). Pilot scan behavior is discussed in the following areas; scanning is a subconscious conditioned activity, scanning is situation dependent, pilots' scanning pattern is centered around a home base. Scanning behavior data have been shown to be useful in determining pilot's workload, evaluating pilot's strategy and role, determining the rate of information transfer of various displays, and aiding in pilot training.

Harris, R. L., Sr.↗

Visual scanning behavior

This report summarizes the results and knowledge of scan behavior gained in various simulation and laboratory studies. Results were obtained through various analysis techniques such as real-time viewing of the pilot's scanning behavior and quantitative analysis of scan behavior performance parameters (average dwell time, dwell percentages, instrument transition paths, dwell percentages, instrument transition paths, dwell histograms, and entropy rate measures). Pilot scan behavior is discussed in the following areas; scanning is a subconscious conditioned activity, scanning is situation dependent, pilots' scanning pattern is centered around a home base. Scanning behavior data nave been shown to be useful in determining pilot's workload, evaluating pilot's strategy and role, determining the rate of information transfer of various displays, and aiding in pilot training.

Harris, R. L., Sr.↗

New Pulsars from Arecibo Drift Scan Searches

We report new pulsars discovered in drift-scan data taken by two collaborations (Berkeley/Cornell and STScI/NAIC) during the latter stages of the Arecibo upgrade period. The data were taken with the Penn State Pulsar Machine and are being processed on the COBRA cluster at Jodrell Bank. Processing is roughly 70% complete and has resulted in the detection of 10 new and 31 known pulsars, in addition to a number of pulsar candidates. The 10 new pulsars include one pulsar with a spin-period of 55 ms and another with a spin period of 5.8 ms. At the completion of the processing, we expect to have discovered roughly 20 new pulsars. All new pulsars are being subjected to a program of followup observations at Arecibo to determine spin and astrometric parameters.

McLaughlin, M. A.↗

Safe Active Scanning for Energy Delivery Systems Final Report

The Department of Energy’s Cybersecurity for Energy Delivery Systems Program has funded Safe(r) Active Scanning for Energy Delivery Systems, led by Lawrence Livermore National Laboratory, to investigate and analyze the impacts of active scanning in the operational environment of energy delivery systems. In collaboration with Pacific Northwest National Laboratory and Idaho National Laboratory, active scans across three testbeds including 38 devices were performed. This report gives a summary of the initial literature survey performed on the SASEDS project as well as industry partner interview summaries and main findings from Phase 1 of the project. Additionally, the report goes into the details of scanning techniques, methodologies for testing, testbed descriptions, and scanning results, with appendices to elaborate on the specific scans that were performed. As a result of testing, a single device out of 38 exhibited problems when actively scanned, and a reboot was required to fix it. This single failure indicates that active scanning is not likely to have a detrimental effect on the safety and resilience of energy delivery systems. We provide a path forward for future research that could enable wide adoption of active scanning and lead utilities to incorporate active scanning as part of their default network security plans to discover and rectify rogue devices, adversaries, and services that may be on the network. This increased network visibility will allow operational technology cybersecurity practitioners to improve their situational awareness of networks and their vulnerabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pointing a ground antenna at a spinning spacecraft using Conscan-simulation results

The results are presented for an investigation of ground antenna pointing errors which are caused by fluctuations of the receiver AGC signal due to thermal noise and a spinning spacecraft. Transient responses and steady-state errors and losses are estimated using models of the digital Conscan (conical scan) loop, the FFT, and antenna characteristics. Simulation results are given for the on-going Voyager mission and for the upcoming Galileo mission, which includes a spinning spacecraft. The simulation predicts a 1 sigma pointing error of 0.5 to 2.0 mdeg for Voyager, assuming an AGC loop SNR of 35 to 30 dB with a scan period varying from 128 to 32 sec, respectively. This prediction is in agreement with the DSS 14 antenna Conscan performance of 1.7 mdeg for 32 sec scans as reported in earlier studies. The simulation of Galileo predicts 1 mdeg error with a 128 sec scan and 4 mdeg with a 32 sec scan under similar AGC conditions.

Mileant, A.↗

Pointing a ground antenna at a spinning spacecraft using conical scan - Simulation results

The results are presented for an investigation of ground antenna pointing errors which are caused by fluctuations of the receiver AGC signal due to thermal noise and a spinning spacecraft. Transient responses and steady-state errors and losses are estimated using models of the digital Conscan (conical scan) loop, the FFT, and antenna characteristics. Simulation results are given for the on-going Voyager mission and for the upcoming Galileo mission, which includes a spinning spacecraft. The simulation predicts a 1 sigma pointing error of 0.5 to 2.0 mdeg for Voyager, assuming an AGC loop SNR of 35 to 30 dB with a scan period varying from 128 to 32 sec, respectively. This prediction is in agreement with the DSS 14 antenna Conscan performance of 1.7 mdeg for 32 sec scans as reported in earlier studies. The simulation of Galileo predicts 1 mdeg error with a 128 sec scan and 4 mdeg with a 32 sec scan under similar AGC conditions.

Mileant, Alexander↗

A facsimile system using room-temperature injection-laser scanning

This paper reports the first use of CW room-temperature injection lasers in a scanning facsimile system. The document reader can resolve about 2000 spots in each horizontal line of its raster scan, which is close to the performance attained using an He-Ne gas laser. The results obtained thus suggest that these small, efficient lasers can replace gas lasers in many applications.

Goedertier, P. V.↗

The EBEX Balloon-borne Experiment—Gondola, Attitude Control, and Control Software

The E and B Experiment (EBEX) was a long-duration balloon-borne instrument created to measure the polarization of the cosmic microwave background (CMB) radiation. EBEX was the first balloon-borne instrument to implement a kilopixel array of transition edge sensor (TES) bolometric detectors and the first CMB experiment to use the digital version of the frequency domain multiplexing system for readout of the TES array. The scan strategy relied on 40 s peak-to-peak constant-velocity azimuthal scans. We report on the unique demands on the design and operation of the payload that resulted from these new technologies and the scan strategy. We describe the solutions implemented, including the development of a power system designed to provide a total of at least 2.3 kW, a cooling system to dissipate 590 W consumed by the detectors' readout system, software to manage and handle the data of the kilopixel array, and specialized attitude reconstruction software. We demonstrate flight performance data reflecting faultless management of the TES array, adequate powering and cooling of the readout electronics, and constraint of attitude reconstruction errors such that the spurious B-modes they induced were less than 10% of the CMB B-mode power spectrum with r = 0.05.

polarization↗

The effectiveness of an oculometer training tape on pilot and copilot trainees in a commercial flight training program

A study was designed to evaluate the effectiveness of a video tape detailing the various aspects of instrument scanning by experienced pilots on performance by pilots and copilots undergoing flight training in a Boeing 737 flight simulator. The performance ratings by instructor pilots (IP's) and self-reported instrument scan behavior by trainees were compared with those of a control group. The results indicated that the training tape had little or no effect on performance by trainees in the experimental group. Feedback from the IP's and trainees suggested that a feedback strategy providing each trainee's individual instrument scan behavior might be more beneficial in flight training than the general instructional strategy of the oculometer training tape. Flight training personnel and trainees' reports of performance decrements on or around the third day of flight simulator training were investigated. The IP's performance ratings of 27 pilot and copilot trainees failed to reveal a systematic performance decrement; however, feedback from the trainees revealed that their own attribution of performance decrements was associated with the order in which their training occurred within a session. Further research was suggested.

Jones, D. H.↗

Direct observation of nanometer-scale strain field around CoSi{sub 2}/Si interface using scanning moiré fringe imaging

We report the use of scanning moiré fringe (SMF) imaging through high-angle annular dark-field scanning transmission electron microscopy (STEM) to measure the strain field around a CoSi{sub 2} contact embedded in the source and drain (S/D) region of a transistor. The atomic arrangement of the CoSi{sub 2}/Si (111) interface was determined from the high-resolution (HR)-STEM images, and the strain field formed around the S/D region was revealed by nanometer-scale SMFs appearing in the STEM image. In addition, we showed that the strain field in the S/D region measured by SMF imaging agreed with results obtained via peak-pairs analysis of HR-STEM images.

36 MATERIALS SCIENCE↗

Fast scan control for deflection type mass spectrometers

A high speed scan device is reported that allows most any scanning sector mass spectrometer to measure preselected gases at a very high sampling rate. The device generates a rapidly changing staircase output which is applied to the accelerator of the spectrometer and it also generates defocusing pulses that are applied to one of the deflecting plates of the spectrometer which when shorted to ground deflects the ion beam away from the collector. A defocusing pulse occurs each time there is a change in the staircase output.

Yeager, P. R.↗

Utah FORGE: Well 16A(78)-32 Core Analysis Results

This dataset features petrographic, X-Ray Diffraction (XRD), and Scanning Electron Microscopy Analyses of core samples from well 16A(78)-32, which serves as the injection well for the Utah FORGE Enhanced Geothermal System (EGS) project. In addition to an overview of the analysis, the following items have been included here: images of 21 entire thin sections in plane-polarized and cross-polarized light from 16 depths, scanning electron microscope back scatter electron photomosaic maps of 21 thin sections from 16 depths, bulk XRD data from 16 depths, clay-sized XRD patterns from 16 depths, an optical petrography report, and scanning electron microscopy and energy dispersive spectroscopy analyses of eight selected samples.

15 GEOTHERMAL ENERGY↗

A database for estimating organ dose for coronary angiography and brain perfusion CT scans for arbitrary spectra and angular tube current modulation

Purpose: The purpose of this study was to develop a database for estimating organ dose in a voxelized patient model for coronary angiography and brain perfusion CT acquisitions with any spectra and angular tube current modulation setting. The database enables organ dose estimation for existing and novel acquisition techniques without requiring Monte Carlo simulations. Methods: The study simulated transport of monoenergetic photons between 5 and 150 keV for 1000 projections over 360 Degree-Sign through anthropomorphic voxelized female chest and head (0 Degree-Sign and 30 Degree-Sign tilt) phantoms and standard head and body CTDI dosimetry cylinders. The simulations resulted in tables of normalized dose deposition for several radiosensitive organs quantifying the organ dose per emitted photon for each incident photon energy and projection angle for coronary angiography and brain perfusion acquisitions. The values in a table can be multiplied by an incident spectrum and number of photons at each projection angle and then summed across all energies and angles to estimate total organ dose. Scanner-specific organ dose may be approximated by normalizing the database-estimated organ dose by the database-estimated CTDI{sub vol} and multiplying by a physical CTDI{sub vol} measurement. Two examples are provided demonstrating how to use the tables to estimate relative organ dose. In the first, the change in breast and lung dose during coronary angiography CT scans is calculated for reduced kVp, angular tube current modulation, and partial angle scanning protocols relative to a reference protocol. In the second example, the change in dose to the eye lens is calculated for a brain perfusion CT acquisition in which the gantry is tilted 30 Degree-Sign relative to a nontilted scan. Results: Our database provides tables of normalized dose deposition for several radiosensitive organs irradiated during coronary angiography and brain perfusion CT scans. Validation results indicate total organ doses calculated using our database are within 1% of those calculated using Monte Carlo simulations with the same geometry and scan parameters for all organs except red bone marrow (within 6%), and within 23% of published estimates for different voxelized phantoms. Results from the example of using the database to estimate organ dose for coronary angiography CT acquisitions show 2.1%, 1.1%, and -32% change in breast dose and 2.1%, -0.74%, and 4.7% change in lung dose for reduced kVp, tube current modulated, and partial angle protocols, respectively, relative to the reference protocol. Results show -19.2% difference in dose to eye lens for a tilted scan relative to a nontilted scan. The reported relative changes in organ doses are presented without quantification of image quality and are for the sole purpose of demonstrating the use of the proposed database. Conclusions: The proposed database and calculation method enable the estimation of organ dose for coronary angiography and brain perfusion CT scans utilizing any spectral shape and angular tube current modulation scheme by taking advantage of the precalculated Monte Carlo simulation results. The database can be used in conjunction with image quality studies to develop optimized acquisition techniques and may be particularly beneficial for optimizing dual kVp acquisitions for which numerous kV, mA, and filtration combinations may be investigated.

60 APPLIED LIFE SCIENCES↗

Orbital-Resolved Imaging of the Adsorbed State of Pyridine on GaP(110) Identifies Sites Susceptible to Nucleophilic Attack

Artificial photosynthesis by photoelectrocatalytic CO 2 reduction is dependent, as is natural photosynthesis, on interfacial electron transfer to couple light excitation energy to reaction centers. For heterogeneous systems, in the context of frontier orbital theory, artificial reaction centers are defined through the interactions of filled and empty orbitals within a few electron volts of the Fermi energy of the adsorbate complex. Here we report a scanning tunneling microscopy (STM) and density functional theory investigation of the orbital-resolved adsorption state defining the dative bonding interaction between a III-V semiconductor surface [GaP(110)] and a N containing heteroaromatic (pyridine). This system was selected for its relevance to photoelectrocatalysis utilizing heteroaromatic co-catalysts, which has been reported to yield highly selective CO 2 reduction to fuels. By examining the distribution of unoccupied molecular orbitals, we show that STM images can be used to positively identify the sites on pyridine susceptible to nucleophilic attack, consistent with frontier orbital theory. Furthermore, this indicates that STM can be used to explore the local reaction centers of adsorbed ambidentate electrophiles and nucleophiles relevant to artificial photosynthesis, and more broadly to generate critical mechanistic information for various heterogeneous acid-base reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗