Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan path optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Plasmonic enhancement of thin-film solar cells using gold-black coatings

Coatings of conducting gold-black nano-structures on commercial thin-film amorphous-silicon solar cells enhance the short-circuit current by 20% over a broad spectrum from 400 to 800 nm wavelength. The efficiency, i.e. the ratio of the maximum electrical output power to the incident solar power, is found to increase 7% for initial un-optimized coatings. Metal blacks are produced cheaply and quickly in a low-vacuum process requiring no lithographic patterning. The inherently broad particle-size distribution is responsible for the broad spectrum enhancement in comparison to what has been reported for mono-disperse lithographically deposited or self-assembled metal nano-particles. Photoemission electron microscopy reveals the spatial-spectral distribution of hot-spots for plasmon resonances, where scattering of normally-incident solar flux into the plane increases the effective optical path in the thin film to enhance light harvesting. Efficiency enhancement is correlated with percent coverage and particle size distribution, which are determined from histogram and wavelet analysis of scanning electron microscopy images. Electrodynamic simulations reveal how the gold-black particles scatter the radiation and locally enhance the field strength.

14 SOLAR ENERGY↗

New perspectives for high accuracy SLR with second generation geodesic satellites

This paper reports on the accuracy limitations imposed by geodesic satellite signatures, and on the potential for achieving millimetric performances by means of alternative satellite concepts and an optimized 2-color system tradeoff. Long distance laser ranging, when performed between a ground (emitter/receiver) station and a distant geodesic satellite, is now reputed to enable short arc trajectory determinations to be achieved with an accuracy of 1 to 2 centimeters. This state-of-the-art accuracy is limited principally by the uncertainties inherent to single-color atmospheric path length correction. Motivated by the study of phenomena such as postglacial rebound, and the detailed analysis of small-scale volcanic and strain deformations, the drive towards millimetric accuracies will inevitably be felt. With the advent of short pulse (less than 50 ps) dual wavelength ranging, combined with adequate detection equipment (such as a fast-scanning streak camera or ultra-fast solid-state detectors) the atmospheric uncertainty could potentially be reduced to the level of a few millimeters, thus, exposing other less significant error contributions, of which by far the most significant will then be the morphology of the retroreflector satellites themselves. Existing geodesic satellites are simply dense spheres, several 10's of cm in diameter, encrusted with a large number (426 in the case of LAGEOS) of small cube-corner reflectors. A single incident pulse, thus, results in a significant number of randomly phased, quasi-simultaneous return pulses. These combine coherently at the receiver to produce a convolved interference waveform which cannot, on a shot to shot basis, be accurately and unambiguously correlated to the satellite center of mass. This paper proposes alternative geodesic satellite concepts, based on the use of a very small number of cube-corner retroreflectors, in which the above difficulties are eliminated while ensuring, for a given emitted pulse, the return of a single clean pulse with an adequate cross-section.

Lund, Glenn↗

Embedded Sensor Development in Metallic Structures for the Transformational Challenge Reactor

The ability to make minimally intrusive measurements of process conditions has tremendous potential for improving system performance and control in applications such as nuclear power generation. Towards this end, emerging and evolving advanced manufacturing methods, such as additive manufacturing, present new opportunities for more seamlessly integrating sensing with structure. This technical report summarizes the progress of work performed to assess the feasibility of embedding commercial off-the-shelf (COTS) sensors in a metallic reactor core using advanced manufacturing methods. The progress of four research and development tasks are documented: 1) A survey of COTS sensors for nuclear applications that are candidates for embedded fabrication, 2) Development of a conceptual framework for investigating the feasibility of sensor embedment, 3) Definition of structural geometries and other characteristics that will represent compelling proof-of-concept, and 4) Preliminary prototyping of embedded sensors. For the purposes of this initial study, nuclear grade K-type thermocouples were selected for investigation of embedment methodologies. This sensor was selected as an initial candidate because it represents one of the simplest sensor configurations that can provide useful process information. A selective laser melting (SLM) additive manufacturing process was used to fabricate structures with complexity representative of the core design of the transformational challenge reactor (TCR) and methods were developed to embed a thermocouple with a complex two-dimensional routing path. There are many challenges associated with embedding sensors during the additive manufacturing process including securing the sensor in the structure, relocating the part in the additive machine if using a “pick and place” sensor placement method, mitigating the potential for powder contamination, optimizing energy deposition parameters to build as closely as possible around the sensor path and improve structural integrity of the part, and tuning energy deposition to mitigate thermally induced warpage of the sensor and part as well as potential for damaging the sensing device. Preliminary results indicate that it is feasible to integrate the sensor while minimally compromising the structural integrity of the part and preserving sensor performance. This first phase of this work focused on developing a workflow for embedding sensors and controlling energy deposition during the additive manufacturing process to better understand the build characteristics around the sensor. Future work will perform more in-depth characterization of prototype parts using X-ray computed tomography and scanning electron microscopy to better understand fabricated structures, performance testing of embedded sensors in high temperature environments, adding new embedded measurement modalities, embedding devices with dissimilar materials in contact with additive powders, and the development of methods for embedding sensors with three-dimensional routing paths.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tomographic retrieval of cloud liquid water fields from a single scanning microwave radiometer aboard a moving platform – Part 1: Field trial results from the Wakasa Bay experiment

Tomographic methods offer great potential for retrieving three-dimensional spatial distributions of cloud liquid water from radiometric observations by passive microwave sensors. Fixed tomographic systems require multiple radiometers, while mobile systems can use just a single radiometer. Part 1 (this paper) examines the results from a limited cloud tomography trial with a single-radiometer airborne system carried out as part of the 2003 AMSR-E validation campaign over Wakasa Bay of the Sea of Japan. During this trial, the Polarimetric Scanning Radiometer (PSR) and Microwave Imaging Radiometer (MIR) aboard the NASA P-3 research aircraft provided a useful dataset for testing the cloud tomography method over a system of low-level clouds. We do tomographic retrievals with a constrained inversion algorithm using three configurations: PSR, MIR, and combined PSR and MIR data. The liquid water paths from the PSR retrieval are consistent with those from the MIR retrieval. The retrieved cloud field based on the combined data appears to be physically plausible and consistent with the cloud image obtained by a cloud radar. We find that some vertically-uniform clouds appear at high altitudes in the retrieved field where the radar shows clear sky. This is likely due to the sub-optimal data collection strategy. This sets the stage for Part 2 of this study that aims to define optimal data collection strategies using observation system simulation experiments.

54 ENVIRONMENTAL SCIENCES↗

Optimizing Surfactant Templating of Yttria-stabilized Zirconia Aerogels for High-temperature Applications: Effect of Anionic & Nonionic Surfactant

Aerogels are useful thermal insulators due to low density, low thermal conductivity, and a tortuous path for solid conduction. However, the formulation must be optimized to increase thermal stability as drastic densification and surface area decrease is often exhibited after high-temperature exposure. Current research investigates yttria-stabilized zirconia (YSZ) aerogels for expected use between 600°C and 1000°C. We anticipate that new sol-gel chemistries will yield YSZ aerogels with retained mesoporous structure, increased surface area, and minimized shrinkage upon high-temperature exposure. This work investigates the anionic surfactant, sodium dodecyl sulfate (SDS), and the nonionic surfactant, Pluronic® P-123, as templating agents to prevent the collapse of the aerogel pore structure upon gelation and drying. To determine the effect of surfactant, characterization techniques such as nitrogen physisorption, x-ray diffraction, and scanning electron microscopy are used. By optimizing surfactant concentration, the thermal stability of YSZ aerogels can be enhanced, producing more efficient thermal insulators.

Rebecca C. Walker↗

TH-A-BRE-01: The Status of Intensity Modulated Proton and Ion Therapy

IMRT with photons has become a radiation therapy standard of care for many cancer treatment sites. The situation is quite different with intensity modulated particle (protons and ion) radiation therapy (IMPT). With the rapid development of beam scanning techniques and many of the newer proton facilities exclusively offering active beam scanning as their radiation delivery technique, it is timely to give an update on the status and challenges of IMPT. The leading principle in IMPT is to aim at the target from several, not necessarily coplanar, directions with multiple pencil beams that are modulated in their intensity and adjusted in their energy such that a desired dose distribution or, more generally, a desired bio-effective dose distribution is achieved. Different from low-LET photons, the varying relative biological effectiveness (RBE) along the beam path adds an additional dimension to the treatment planning process and will require biophysical modeling at least for carbon ion therapy. IMPT involves computationally challenging tasks, yet it needs to be very fast in order to be clinically relevant. To make IMPT computationally tractable, robust and efficient optimization methods are required. Lastly, IMPT planning is very sensitive to accurate knowledge of relative stopping and scattering powers of the intervening tissues as well as intra- and inter-fraction motion. Robust planning methods are being developed in order to obtain IMPT plans that are less sensitive against such uncertainties. This therapy symposium will present an update on the current status and emerging developments of IMPT from the medical physics perspective. Learning Objectives: Become familiar with current delivery techniques for IMPT and their limitations. Understand the basics of dose calculational algorithms and commissioning of IMPT. Learn how to assess the accuracy of planning and delivery of IMPT treatments. Get an overview of currently used and emerging optimization techniques. Learn about the pro or contra arguments for using IMPT for moving targets.

07 ISOTOPE AND RADIATION SOURCES↗

Synergistic Improvement of Carbohydrate and Lignin Processability by Biomimicking Biomass Processing

The sustainability and economic feasibility of modern biorefinery depend on the efficient processing of both carbohydrate and lignin fractions for value-added products. By mimicking the biomass degradation process in white-rote fungi, a tailored two-step fractionation process was developed to maximize the sugar release from switchgrass biomass and to optimize the lignin processability for bioconversion. Biomimicking biomass processing using Formic Acid: Fenton: Organosolv (F 2 O) and achieved high processability for both carbohydrate and lignin. Specifically, switchgrass pretreated by the F 2 O process had 99.6% of the theoretical yield for glucose release. The fractionated lignin was also readily processable by fermentation via Rhodococcus opacus PD630 with a lipid yield of 1.16 g/L. Scanning electron microscope analysis confirmed the fragmentation of switchgrass fiber and the cell wall deconstruction by the F 2 O process. 2D-HSQC NMR further revealed the cleavage of aryl ether linkages (β-O-4) in lignin components. These results revealed the mechanisms for efficient sugar release and lignin bioconversion. The F 2 O process demonstrated effective mimicking of natural biomass utilization system and paved a new path for improving the lignin and carbohydrate processability in next generation lignocellulosic biorefinery.

09 BIOMASS FUELS↗

TPSAS-NF1676L-28149-DND

An Optimal Estimation (OE) inversion method has been developed to retrieve vertical profiles of aerosol size distributions, volume/surface concentrations, complex refractive indices, and single scattering albedos using the High Spectral Resolution Lidar (HSRL) and polarimeter measurements. By combining the active and passive remote sensing data, we can take advantages of the high vertical resolution of the lidar measurements and the high information content of the combined observations. There are three components to the new retrieval system: 1) simultaneous aerosol vertical profile retrieval using HSRL data, 2) standalone aerosol retrieval using Research Scanning Polarimeter (RSP), and 3) combined HSRL and RSP optimal estimation retrieval. For the LIDAR retrieval, we solve for number concentrations, mode fractions, aerosol size distributions, and real and imaginary part of refractive indices simultaneously. Based on this information, other parameters such as effective particle radius, surface and volume concentration, single scattering albedo can be derived. The combined HSRL-polarimeter algorithm will provide improved single scattering albedo and refractive index retrievals. The newly developed retrieval algorithm is very fast, and it provides an optimal estimation solution with associated error estimates. By solving for the aerosol vertical profiles using HSRL extinctions and backscattering coefficients from different layers, the new OE method can effectively reduce the impact of measurement noise on the retrieved aerosol microphysical properties. It also enables us to effectively combing HSRL and RSP data in the single OE retrieval system since the passive polarimeter instruments measure path-integrated intensity and polarizations. We have performed sensitivity studies using simulated data and applied the OE algorithms to NASA airborne field data measured by the HSRL-2 and the RSP instruments.

Xu Liu↗

Range Imaging without Moving Parts

Range-imaging instruments of a type now under development are intended to generate the equivalent of three-dimensional images from measurements of the round-trip times of flight of laser pulses along known directions. These instruments could also provide information on characteristics of targets, including roughnesses and reflectivities of surfaces and optical densities of such semi-solid objects as trees and clouds. Unlike in prior range-imaging instruments based on times of flight along known directions, there would be no moving parts; aiming of the laser beams along the known directions would not be accomplished by mechanical scanning of mirrors, prisms, or other optical components. Instead, aiming would be accomplished by using solid-state devices to switch input and output beams along different fiber-optic paths. Because of the lack of moving parts, these instruments could be extraordinarily reliable, rugged, and long-lasting. An instrument of this type would include an optical transmitter that would send out a laser pulse along a chosen direction to a target. An optical receiver coaligned with the transmitter would measure the temporally varying intensity of laser light reflected from the target to determine the distance and surface characteristics of the target. The transmitter would be a combination of devices for generating precise directional laser illumination. It would include a pulsed laser, the output of which would be coupled into a fiber-optic cable with a fan-out and solid-state optical switches that would enable switching of the laser beam onto one or more optical fibers terminated at known locations in an array on a face at the focal plane of a telescope. The array would be imaged by the telescope onto the target space. The receiver optical system could share the aforementioned telescope with the transmitter or could include a separate telescope aimed in the same direction as that of the transmitting telescope. In either case, light reflected from the target would be focused by the receiver optical system onto an array of optical fibers matching the array in the transmitter. These optical fibers would couple the received light to one or more photodetector( s). Optionally, the receiver could include solid-state optical switches for choosing which optical fiber(s) would couple light to the photodetector(s). This instrument architecture is flexible and can be optimized for a wide variety of applications and levels of performance. For example, it is scalable to any number of pixels and pixel resolutions and is compatible with a variety of ranging and photodetection methodologies, including, for example, ranging by use of modulated (including pulsed and encoded) light signals. The use of fixed arrays of optical fibers to generate controlled illumination patterns would eliminate the mechanical complexity and much of the bulk of optomechanical scanning assemblies. Furthermore, digital control of the selection of the fiber-optic pathways for the transmitted beams could afford capabilities not seen in previous three-dimensional range-imaging systems. Instruments of this type could be specialized for use as, for example, proximity detectors, three-dimensional robotic vision systems, airborne terrain-mapping systems, and inspection systems.

Blair, J. Bryan↗

High-efficiency cross-beam magnetic electron-impact source for improved miniature Mattauch-Herzog mass spectrometer performance

We describe a newly designed cross-beam magnetic electron-impact ion source (CBM-EI). We demonstrate its superiority in comparison with a conventional source (CB-EI) when used with a commercial miniature sector-field-type, non-scanning mass spectrometer featuring Mattauch-Herzog geometry (MH-MS) and a permanent sector-field magnet. This paper clearly shows the value of the CBM-EI for enhancing MH-MS sensitivity. Unlike secondary electron-multiplier type detectors, the pixelated detector (IonCCD Trade-Mark-Sign ) used in the commercial MH-MS has no gain. The MH-MS/IonCCD system is therefore challenged to compete with time-of-flight and quadrupole MS systems due to their higher ion transmissions and detector gains. Using the new CBM-EI, we demonstrate an instrument sensitivity increase of 20-fold to 100-fold relative to the CB-EI-equipped instrument. This remarkable signal increase by the simple addition of the magnet assembly arises from the magnet-induced gyromotion of the thermionic electrons, which vastly increases the effective path length of the electrons through the ionization region, and the collimated nature of the electron flux, which optimizes the ion transmission through the 100-{mu}m object slit of the MH-MS. Some or all of the realized sensitivity increase may be exchanged for an increase in resolution and/or mass range through the use of a narrower object slit, or for a reduction in ion-source pressure to limit quenching. The CBM-EI should facilitate development of a differentially pumped ion source to extend the lifetime of the filament, especially in otherwise intractable applications associated with oxidizing and corrosive samples.

43 PARTICLE ACCELERATORS↗

SU-E-T-457: Impact of Interfractional Variations On Anterior Vs. Lateral-Field Proton Therapy of Prostate Cancer

Purpose: To investigate the effects of interfractional anatomy and setup variations on plans with anterior-oblique vs. lateral beams for prostate cancer pencil beam scanning (PBS) and passive scattered (PS) proton therapy. Methods: Six patients with low/intermediate risk prostate cancer treated with PS proton therapy at our institution were selected. All patients underwent weekly verification CT scans. Implanted fiducials were used for localization, and endorectal balloons for prostate immobilization. New PBS plans with lateral beams, as well as PBS and PS plans with anterior-oblique beams (±35 deg) were created. PBS plans used two different spot sizes: ∼10mm (large) and ∼5mm (medium) sigma at 25cm range and optimized as single-field-uniform-dose with ∼8% non-uniformity. No range uncertainty margins were applied in PBS plans to maximize rectal sparing. Field-specific apertures were used when planning with large spots to sharpen the penumbrae. The planned dose was recomputed on each weekly CT with fiducials aligned to the simulation CT, scaled and accumulated via deformable image registration. Results: The dose volume analysis showed that although difference between planned and accumulated dose remains negligible for plans with conventional lateral beams using both PS and PBS, this is not the case for plans with anterior beams. The target coverage in anterior plans was largely degraded due to the variations in the beam path length and the absence of range margins. The average prostate D95 was reduced by 7.5/15.9% (using PS/PBS) after accumulation for anterior plans, compared with 0/0.4% for lateral plans. The average mean dose in organs-at-risk decreased by 1% for lateral and 2% for anterior plans, similarly for PS and PBS. Spot size did not affect the dose changes. Conclusion: Prostate plans using anterior beams may undergo clinically relevant interfractional dose degradation. Corrective strategies guided by in-vivo range measurements should be studied before clinical application of this technique.

60 APPLIED LIFE SCIENCES↗

Toward monochromated sub-nanometer UEM and femtosecond UED

A preliminary design of a mega-electron-volt (MeV) monochromator with 10 –5 energy spread for ultrafast electron diffraction (UED) and ultrafast electron microscopy (UEM) is presented. Such a narrow energy spread is advantageous in both the single shot mode, where the momentum resolution in diffraction is improved, and the accumulation mode, where shot-to-shot energy jitter is reduced. In the single-shot mode, we numerically optimized the monochromator efficiency up to 13% achieving 1.3 million electrons per pulse. In the accumulation mode, to mitigate the efficiency degradation caused by the shot-to-shot energy jitter, an optimized gun phase yields only a mild reduction of the single-shot efficiency, therefore the number of accumulated electrons nearly proportional to the repetition rate. Inspired by the recent work of Qi et al. (Phys Rev Lett 124:134803, 2020), a novel concept of applying reverse bending magnets to adjust the energy-dependent path length difference has been successfully realized in designing a MeV monochromator to achieve the minimum energy-dependent path length difference between cathode and sample. Thanks to the achromat design, the pulse length of the electron bunches and the energy-dependent timing jitter can be greatly reduced to the 10 fs level. The introduction of such a monochromator provides a major step forward, towards constructing a UEM with sub-nm resolution and a UED with ten-femtosecond temporal resolution. The one-to-one mapping between the electron beam parameter and the diffraction peak broadening enables a real-time nondestructive diagnosis of the beam energy spread and divergence. The tunable electric–magnetic monochromator allows the scanning of the electron beam energy with a 10 –5 precision, enabling online energy matching for the UEM, on-momentum flux maximizing for the UED and real-time energy measuring for energy-loss spectroscopy. A combination of the monochromator and a downstream chicane enables “two-color” double pulses with femtosecond duration and the tunable delay in the range of 10 to 160 fs, which can potentially provide an unprecedented femtosecond time resolution for time resolved UED.

36 MATERIALS SCIENCE↗

Nanoscale imaging of He-ion irradiation effects on amorphous TaO x toward electroforming-free neuromorphic functions

Resistive switching in thin films has been widely studied in a broad range of materials. Yet, the mechanisms behind electroresistive switching have been persistently difficult to decipher and control, in part due to their non-equilibrium nature. Here, we demonstrate new experimental approaches that can probe resistive switching phenomena, utilizing amorphous TaO x as a model material system. Specifically, we applied scanning microwave impedance microscopy and cathodoluminescence (CL) microscopy as direct probes of conductance and electronic structure, respectively. These methods provide direct evidence of the electronic state of TaO x despite its amorphous nature. For example, CL identifies characteristic impurity levels in TaO x , in agreement with first principles calculations. We applied these methods to investigate He-ion-beam irradiation as a path to activate conductivity of materials and enable electroforming-free control over resistive switching. However, we find that even though He-ions begin to modify the nature of bonds even at the lowest doses, the films' conductive properties exhibit remarkable stability with large displacement damage and they are driven to metallic states only at the limit of structural decomposition. Finally, we show that electroforming in a nanoscale junction can be carried out with a dissipated power of <20 nW, a much smaller value compared to earlier studies and one that minimizes irreversible structural modifications of the films. Importantly, the multimodal approach described here provides a new framework toward the theory/experiment guided design and optimization of electroresistive materials.

36 MATERIALS SCIENCE↗

Regional surrogates for predictive control of digital twins

Digital twins of complex systems must involve a model that is fast, generalizable, and usable for real-time control. For example, high-fidelity nonlinear multiphysics simulations can capture laser-material interactions, but are too slow for optimization or model predictive control (MPC). Reduced-order models, used to accelerate such computation, frequently fail to generalize to unseen inputs or control states. We show theoretically that this failure is intrinsic, i.e., that a learned model is non-unique outside the sampled subspace when its low-rank structure arises from limited excitation and clustered eigenvalues, rather than from a user-imposed truncation alone. Motivated by this result, we propose a control-ready regional surrogate-construction framework for both autonomous and nonautonomous dynamics; it employs Koopman lifting to represent nonlinearities, while preserving spatial locality. We illustrate our approach by constructing a control-ready surrogate for the digital twin of a thermal component of additive-manufacturing process. Our surrogate, localized in space through a von Neumann stencil, is learned from noisy high-fidelity simulations that emulate thermal-camera images collected during the manufacturing. It is linear in thermo-physically augmented states so that MPC reduces to a convex quadratic program. The surrogate requires no online correction, generalizes to unseen scan paths and power profiles of the laser, and is more than three orders of magnitude faster than a finite-difference solver. Furthermore, when the MPC sequence computed on the digital twin is applied to this solver, closed-loop temperature regulation is recovered, showing that the surrogate preserves control-relevant input-output behavior.

Data-driven model↗

Experimental study of energy-dependent angular broadening of MeV electron beams for high-resolution imaging in thick samples

In scanning transmission electron microscopy (STEM), spatial resolution is primarily influenced by the projected size of the electron probe within the specimen. In thin samples, a large semi-convergence angle enables a tightly focused beam and sub-nanometer resolution. However, in thick specimens, resolution is fundamentally limited by transverse beam broadening from multiple large-angle scattering events—for example, a probe with 10 mrad angular divergence can broaden by ∼100 nm over a 10 μm path. Since this broadening scales inversely with beam energy, MeV-STEM offers a promising route for high-resolution imaging in thick materials. To quantitatively assess this effect, we performed high-precision measurements at UCLA’s PEGASUS beamline, characterizing beam divergence and intensity profiles for 3–8 MeV electrons transmitted through a wedged-silicon sample of varying thickness. Our results reconcile discrepancies among analytical models and validate Monte Carlo simulations. Here, we find that increasing beam energy from 3.0 to 5.8 MeV reduces angular broadening by a factor of 2.6, with diminishing returns observed at 7.6 MeV. These findings provide a quantitative framework for optimizing MeV-STEM parameters in high-resolution imaging of thick biological and microelectronic specimens, and for guiding beam energy selection in other advanced imaging modes beyond STEM.

36 MATERIALS SCIENCE↗

A gyrokinetic perspective on the JET-ILW pedestal

JET has been unable to recover historical confinement levels when operating with an ITER-like wall (ILW) due largely to the inaccessibility of high pedestal temperatures. Finding a path to overcome this challenge is of utmost importance for both a prospective JET DT campaign and for future ITER operation. Gyrokinetic simulations (using the Gene code) quantitatively capture experimental transport levels for a representative experimental discharge and qualitatively recover the major experimental trends. Microtearing turbulence is a major transport mechanisms for the low-temperature pedestals characteristic of unseeded JET-ILW discharges. At higher temperatures and/or lower ${{\rho}_{\ast}}$ , we identify electrostatic ITG transport of a type that is strongly shear-suppressed on smaller machines. Consistent with observations, this transport mechanism is strongly reduced by the presence of a low-Z impurity (e.g. carbon or nitrogen at the level of ${{Z}_{\text{eff}}}\sim 2$ ), recovering the accessibility of high pedestal temperatures. Notably, simulations based on dimensionless ${{\rho}_{\ast}}$ scans recover historical scaling behavior except in the unique JET-ILW parameter regime where ITG turbulence becomes important. Our simulations also elucidate the observed degradation of confinement caused by gas puffing, emphasizing the important role of the density pedestal structure. This study maps out important regions of parameter space, providing insights that may point to optimal physical regimes that can enable the recovery of high pedestal temperatures on JET.

Hatch, D. R.↗

MO-AB-BRA-07: Prompt Gamma-Ray Spectroscopy for Range Verification of Clinical Proton Beams

Purpose: We developed a pre-clinical prototype system for range verification of proton pencil-beam scanning fields. The system was evaluated using phantom treatment plans delivered with a clinical dose rate. Methods: The absolute range of proton pencil-beams was verified through an optimization procedure, which matches energy- and time-resolved prompt gamma-ray measurements with models, based on cross sections for discrete prompt gamma-ray line excitations. Phantom experiments were performed with a pre-clinical prototype detector, using treatment plans delivered with a clinical pencil-beam scanning system. The detector consisted of an actively shielded lanthanum(III) bromide scintillator. Tungsten was used to collimate the gamma-rays. To support high event rates, the detector readout featured custom amplifiers and an active voltage divider for the photomultiplier. The detector signals were acquired by fast analog-to-digital converters and processed using digital algorithms. The data acquisition was also synchronized with the pencil-beam scanning and dosimetry systems. Results: We successfully acquired prompt gamma-ray spectra during the delivery of proton pencil-beams with a clinical beam current of 2 nA at the exit of the treatment head. The number of events in the primary detector ranged from 1 x 10{sup 6} to 2 x 10{sup 6} per second. In phantom experiments, non-uniform range errors were introduced by placing strips of plastic in the beam path. The magnitudes and positions of these range errors were correctly detected in two-dimensional range maps that were generated from the measurements. With our small scale prototype, a 1.0 mm standard deviation on the absolute range required about 5 x 10{sup 8} protons per delivered pencil-beam. Conclusions: Prompt gamma-ray spectroscopy to verify the absolute range of proton beams was demonstrated under clinical pencil-beam delivery conditions. A 1 mm to 2 mm range verification accuracy for a field delivering 1 Gy, appears feasible with a full scale system. This work was supported by the Federal Share of program income earned on C06-CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

Lessons Learned from a Complex FUSRAP Site - Sylvania Corning FUSRAP Site - 12269

Since its addition to the Formerly Utilized Sites Remedial Action Program (FUSRAP) in 2005, the Sylvania Corning FUSRAP Site (the Site) in Hicksville, New York, has provided challenges and opportunities from which to gain lessons learned for conducting investigation work at a complex multi-contaminant FUSRAP Site. The United States Army Corps of Engineers (USACE) and its contractors conducted a Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) Remedial Investigation (RI) and are currently in the Feasibility Study (FS) phase at the Site. This paper presents the planning, execution, and reporting lessons learned by USACE during the RI/FS. The Site, operated from 1952 to 1967 for the research, development, and fabrication of nuclear elements under the Atomic Energy Commission, and other government and commercial contracts. Previous investigations performed by the New York State Department of Environmental Conservation (NYSDEC) and the current property owner have identified uranium, thorium, nickel, and chlorinated solvents, as Site contaminants [1]. The property owner is currently under two separate voluntary agreements with NYSDEC to investigate and remediate the Site. USACE's work at the site has been independent of this voluntary agreement and has moved on a parallel path with any work the property owner has completed. The project at the Site is complex because of the radiological and chemical concerns in both soils and groundwater, high hydraulically conductive soils, lack of a shallow aquiclude/aquitard, and a principal water table aquifer underlying the site. Contaminants are migrating from the Site and may potentially impact local drinking water supplies (municipal wells). During the RI/FS process the project team has encountered many issues and has thus developed many resolutions. The issues are organized into three categories: Planning and Contracting, Execution, and Reporting. Planning and Contracting lessons learned include: how to incorporate an overwhelming volume of historical data; how to manage a complex team of three prime contractors innovatively, and how to implement a project under an Award Fee task order. Execution lessons learned include: characterization of investigation derived wastes, and proper approach to radiological scanning of direct-push borings and soil cores. Reporting lessons learned include: coordinating multiple phase (iterative) reporting, large dataset presentation, and the National Priorities List (NPL) designation. The goal of this paper is to provide a resource for other project delivery teams that encounter similar situations on their projects to optimize cost savings, realization of efficiency, shorten schedules, or simply ensure higher quality deliverables. Each FUSRAP project is unique but there are many lessons we can apply to each site to gain efficiency and work more effectively. The Sylvania Corning FUSRAP site is a complex site with both soils and groundwater contamination, contamination to depths of 182 meters, and a highly politically charged environment of PRP involvement. Many of the lessons the project team has learned during the life of the project to date are being shared with others as well as being applied back to this project for future work. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗