Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scaled testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Small-scale validation tests for MFIX-Exa CFD-DEM

This report describes several bench-scale fluidization experiments that can be used to validate the CFD-DEM method as encapsulated in the MFIX-Exa code. The five cases considered are the cold-flow fluidized beds of Müller et al., Link et al. (spout-fluid), and Goldschmidt et al. (bi-disperse), the hot fluidized bed of Patil et al., and the adsorbing fluidized bed of Li et al. and Janssen. In most cases, MFIX-Exa with “standard” or “typical” CFD-DEM settings, the Gidaspow drag model, and the Gunn heat transfer provide a relatively good prediction of the quantities considered: mean void fraction profiles, mean velocity profiles, fluctuating velocity profiles, mean particle temperature and segregation index. These results, with other verification and validation tests reported elsewhere, contribute to a body of work providing confidence and credibility in CFD predictions from the MFIX-Exa code.

97 MATHEMATICS AND COMPUTING↗

Testing Scale-Dependent Modified Gravity with DESI DR1

The Dark Energy Spectroscopic Instrument (DESI) provides an unprecedented opportunity to test deviations from general relativity (GR) that introduce a new physical scale within its redshift range. Using the connection between a Yukawa-like potential and the Hu-Sawicki $f(R)$ model, we place strong constraints on the range of a hypothetical fifth force mediated by a massive scalar field. We analyze the power spectrum measurements from DESI Data Release 1 using a baseline EFT model that employs the fkpt approach for the loop integrals. We find no evidence for deviations from GR and obtain the constraint $\log_{10} |f_{R_0}| < -4.59$ (95% C.L.). This corresponds to an upper bound at redshift zero on the scale at which corrections to GR become important, $λ< 17.81$ Mpc, or equivalently, a lower bound on the mass of the additional gravitational mediator of $m_ϕ> 3.60 \times 10^{-31}$ eV. We find that the modified gravity parameter $f_{R_0}$ is largely orthogonal to the cosmological parameters in the model, such that no additional projection effects relative to the GR case are introduced in this Full-Shape analysis. Furthermore, a second modified gravity parameter, the power index $n$, which modulates the time-variation of the associated mass, is found to be consistent with previous analyses that fixed it to unity. Adding DESI BAO data or other cosmological probes does not significantly change these results. The conclusions remain similar if the background evolution is described by evolving dark energy instead of a cosmological constant. Additionally, we test the robustness of the baseline model by varying the maximum wavenumber used in the Full-Shape analysis and analyzing the DESI targets separately. Finally, we analyze the degeneracies between the modified-gravity parameters and the sum of neutrino masses.

Gonzalez, D. [Guanajuato U.; UNAM, CCF] (ORCID:000↗

Development and Experimental Validation of a Heat Transfer Model for Spilled Molten Salt Pools

A spill of radionuclide-bearing molten salt is one of the major postulated events that needs to be analyzed for liquid fluorine salt-cooled high-temperature reactor (FHR) or molten salt reactor licensing purposes. In this postulated event, radioactive source term materials (RSTMs) in the molten salt are discharged from the reactor vessel to the reactor building. The release of RSTMs from the spilled salt pool to the gas space in the reactor building is expected to be controlled by the cooling behavior of the spilled salt, including the growth and shrinkage of the solid crust on the surface of the spilled salt pool. This paper presents a simulation model for spilled salt pool heat transfer and validation efforts. The validation data come from two molten salt spill tests that were performed recently: the PELE2 test by the Rapid Experimental Laboratory of Kairos Power LLC (KP) and the Argonne salt cooling test conducted by Argonne National Laboratory. The former was a large-scale test involving kilograms of molten spilled FLiNaK salt, and the latter was a relatively smaller-scale test targeting various processes associated with a salt spill event. Both tests generated valuable data sets that can be used to assess salt cooling and validate evaluation models. This paper provides a new one-dimensional model that can simulate the cooling process of a spilled salt pool as well as the thermal responses of heat structures, such as the stainless steel liner and the concrete below the salt. The model has been implemented as part of KP-SAM code, which is a branch of the systems code SAM specific to KP FHR. In conclusion, the simulation results of the model are compared with the data of the PELE2 and Argonne tests, and reasonable agreements are observed between the model and test data.

heat transfer model↗

Development of a rate-based ENRTL-RK process model for a water-lean solvent

Advanced water-lean solvents (WLS) for post-combustion CO2 capture offer several advantages over the aqueous amine solvents . WLS have lower parasitic energy penalty, lower corrosion, lower temperature and high-pressure CO2 regeneration leading to lower cost of CO2 capture. RTI International, with funding from the US Department of Energy, has been developing its novel water-lean solvent, that has shown specific reboiler duty of 2.3 GJ/t-CO2 at the 60-kWe pilot testing unit (Tiller Plant, SINTEF, Norway) and 2.6 GJ/t-CO2 at the engineering scale testing system (12 MWe) at the Technology Centre Mongstad (TCM) in Norway. All heat duties, including the one from TCM testing, were consistent with Aspen Plus modeling of the specific configuration of each test plant. This work focuses on the development of a detailed process model using in-house laboratory measurements and process data at pilot scale. The eNTRL-RK model used in this work is based on an unsymmetric activity coefficient model with the reference states chosen to be pure liquids for solvents and ideal dilute solution at unit solute molality (resulting in activity coefficient of unity at infinite dilution) for electrolytes. It uses the Redlich-Kwong equation of state for vapor phase properties and Henry’s law for solubility of supercritical gases. The model was validated using process data from the pilot-scale campaign at the Tiller plant, and the engineering scale test campaign at TCM. Data on CO2 capture rate, absorber, and regenerator temperature profiles and specific reboiler duties from two different test campaigns at Tiller and TCM, were used to further refine and validate the model and the model compares favorably to experimental data. The validation results against TCM campaign will be presented in this work.

CO2 capture↗

Flow Sensor Test Article (F-STAr) (Design and Fabrication Status Report)

The Flow Sensor Test Article (F-STAr) is a test article currently under construction for the Mechanisms Engineering Test Loop (METL). F-STAr was designed to provide high sodium flowrate capabilities for sensor calibration, component testing, and fluid studies. Figure 1 shows two solid model views of the new test article. F-STAr includes a high-capacity pump that can provide a nominal flowrate of 120 GPM; a test section support structure that can accommodate a wide array of sub-test articles and their instrumentation; and finally, a heating and cooling system to aid in controlling the testing environment. Initially, F-STAr will be configured to test liquid metal flow sensors, specifically field shift sensors like the Eddy Current Flow Sensors (ECFS) based on the RDT C4-7T standard. To test these sensors, two test sections were designed that attempt to model Sodium Fast Reactor (SFR) outlet conditions. Figure 2 shows models of the “Full-Scaled Test Section” (FSTS) that represents a generic SFR fuel handling socket and a “Pseudo-Scaled Test Section” (PSTS) that represents a generic array of scaled fuel handling sockets. While F-STAr will be configured to test ECFS’s, it can also be outfitted to meet other experimental needs. For example, F-STAr could be setup with a test section that includes a fluidic diode or a component test investigating the performance of hydrodynamic bearings. Other test sections include studies of sodium thermal hydraulics like thermal striping. Overall, F-STAr is a flexible test article designed to accommodate many needs. This report will provide a status update on the design and construction of F-STAr. Manufacturing of all components has commenced, and several components have already been completed. These components include the pump and test section assembly stand. Other components, such as the heater, have been completed but were rejected due to the vendor not meeting the requirements of the purchase order. Lastly, the submersible flowmeter and main flange components are under construction, and their status will be reviewed in this report. Overall, most of the F-STAr components and parts will be completed by the end of September 2022.

42 ENGINEERING↗

Nonlinear Impact-Echo Test for Quantitative Evaluation of ASR Damage in Concrete

Nonlinear acoustic methods demonstrate high sensitivity for concrete damage evaluation. Among these methods, nonlinear resonance acoustic methods have been widely used in laboratory tests on small scale test samples. In this study, a nonlinear impact-echo (IE) method for concrete damage evaluation was introduced, in which the IE frequency shift was measured at different impact force levels. The nonlinear IE test and the nonlinear impact resonance acoustic spectroscopy (NIRAS) test share similarities in the experimental setup and analysis method. However, the nonlinear IE test excites a local thickness resonance mode of a member instead of the global resonance vibration. Therefore, the analyzed mode is unaffected by member boundary conditions and is applicable to large concrete structural members. To identify the fundamental IE frequencies, multiple impacts were applied along the members. Once the fundamental IE frequencies were determined, the effectiveness of the nonlinear IE method was evaluated by testing seven concrete beam specimens with varying levels of alkali-silica reaction (ASR) damage. In conclusion, the nonlinear IE test demonstrates high sensitivity to concrete damage and allows for quantitative assessment of the damage state of concrete without a baseline measurement.

36 MATERIALS SCIENCE↗

High Performance Solvent for NGCC Flue Gas CO 2 Capture (Final Technical Report)

Amine-based solvent absorption is the most mature and reliable technology for large scale CO 2 capture, dating back to the 1930s when monoethanolamine (MEA) was used to treat acid gases from oil refineries. However, while strategic advancements have optimized the CO2 capture process, the cost of capture remains high, where current estimates suggest that CO 2 capture costs are around $\$$72/tonne of CO 2 . To address this, solvent development and optimization have become a focus of current research. This project sought to develop a high-performance solvent to reduce the overall cost of CO 2 capture from NGCC flue gas. Here, solvent optimization focused on: (1) reducing the energy required for CO 2 desorption in a reboiler, (2) improving CO 2 absorption and desorption reaction kinetics, (3) improving solvent stability, and (4) reducing environmental impacts. Susteon has developed and evaluated a promoted solvent, Sustenol™, for NGCC flue gas CO 2 capture. The optimized Sustenol™ also shows a higher dynamic CO 2 absorption capacity of ~0.5 mol CO2 /mol amine compared to 0.25 mol CO2 /mol amine for 30 wt% MEA. Additionally, the solvent is oxidatively, thermally and hydrothermally stable, which leads to lower solvent loss and emissions. These advancements have resulted in a solvent regeneration energy of 2.16 GJ/tonne of CO 2 which is >30% lower than current state-of-the-art commercial and emerging solvents. Combined with empirical data from the bench and pilot scale testing, this preliminary TEA study indicated the cost of CO 2 capture by Sustenol™ for 97% CO 2 removal at $\$$54/tonne and for 90% removal at $\$$49/tonne, with a pathway to achieve $\$$45/tonne of CO 2 with continued process and solvent advancements. Susteon has developed a technology roadmap to reduce the cost of CO 2 capture to <$\$$45/tonne for NGCC flue gas. Susteon plans to derisk this technology for commercial deployment through comprehensive solvent degradation testing, long-term testing in a pilot plant at 5 tonne CO2 /day and demonstration scale testing at 100 tonne CO2 /day with NGCC flue gas and engineering design studies to qualify Sustenol™ as a drop-in replacement solvent.

03 NATURAL GAS↗

Geometry Optimization of Cable-Based Actuation for Small-Scale Model Testing of a Floating Marine Turbine: Preprint

This research aims to apply combined wave and tidal current loads to a small-scale floating marine current turbine in a wave tank, where an actuation system applies hydrodynamic and mooring forces on the hardware based on results from a simulation. We use a real-time hybrid test setup with physical wave forcing from the wave tank and simulated current and mooring forces implemented through a tensioned cable array. For this paper, we developed an optimization algorithm that adjusts the hardware geometry of the cable array to achieve more efficient tension allocation across the cables for the loads that need to be actuated. By adjusting the points where the cables are attached to the floating platform and the angles between the platform and the winches, an optimal cable geometry can be found to minimize tension variations in the lines, maintain the desired pretension, and prevent excessive tensions. We present the optimization problem formulation, the actuation system evaluation approach, and optimization results that show effective cable actuation setups that are being considered for implementation in the wave tank tests.

cable-based actuation↗

Standardizing an Intermediate-Scale High Explosive Safety Test Suite

Small-scale safety testing, while successful in screening out extremely dangerous explosive compositions, does not fully characterize the explosive hazards associated with handling larger, consolidated or bare charges. It is proposed that intermediate-scale tests using consolidated charges in the range 25 mg – 1 kg are warranted to satisfactorily address the hazards. A standard for this intermediate-scale testing should be developed, proofed, peer-reviewed and adopted to assist in the development of safe new high explosive compositions across the complex. This whitepaper explains why current small-scale safety testing is insufficient to characterize the handling hazard, identifies the guiding aspects of explosive response that drive the handling hazards associated with larger consolidated charges, and proposes a suite of tests/experiments that can serve as a starting point for an intermediate-scale safety standard.

42 ENGINEERING↗

Data Center Power Systems: Architectures, Impact on Grid Reliability, Modeling Considerations, and Megawatt-Scale Hardware Testing [Slides]

This slide deck describes typical power systems of large datacenters along with reliability problems to bulk power systems from large-scale integration of datacenters. The slide deck covers the architecture of datacenter power systems, different power electronic converters used inside datacenters, their operation modes, and R&Dopportunities in maintaining grid stability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vitrification of Inactive Incineration Ash in a Full Industrial Scale In Can Melter - 20502

In the framework of the H2020 THERAMIN project funded by the European Commission, CEA performed a pilot-scale trial consisting of the vitrification of inactive ash (Al, Ca, Si, Zn, Bi, K, Mg, etc.) using the In- Can Melter technology. These ashes were coming from incineration of simulated technological wastes such as cotton, latex, neoprene, polyethylene. The borosilicate glass feasibility was first evaluated at a laboratory scale (10-100 g of glass). The volatile behavior of fly ash was controlled by pelletizing to avoid pipes clogging when performing the pilot scale test. A 10 wt.% inorganic binder was added to obtain cohesive pellets. The glass frit composition was selected and its ratio was fixed at 50 wt.%. After this step, a bench test (1 kg of glass) was done to verify the absence of container corrosion. Finally, it was followed by a pilot scale test (50 kg of glass) with 75,000 ash pellets used. The same glass microstructure and chemical composition were observed at each scale. Typical crystals of apatites (Ca, P), zincochromites (Zn, Cr, Al) and bismuth alloys (Bi, Sb) dispersed into a borosilicate glass matrix were observed. The chemical durability of the wasteform was measured during 28 days in a 90 deg. C water. Although there were durable crystalline phases, the hydrolysis rate of the vitreous part is relatively high because of the B and Na contents. However, leach rate profiles suggest that an alteration layer will form, leading to an alteration rate decrease. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Unraveling the Highly Plastic Behavior of ALD-Aluminum Oxide Encapsulations by Small-Scale Tensile Testing

We present a study directly measuring the electron-beam-induced plasticity of amorphous Al 2 O 3 coatings. Core–shell nanostructures are employed as small-scale model systems for two-dimensional coatings made by atomic layer deposition (ALD). Copper nanowires (NWs) are used as substrates for ALD deposition, representing a model system for interconnects commonly found in integrated circuits. Experiments are performed in situ in a transmission electron microscope (TEM) and further analyzed with electron energy loss spectroscopy (EELS). Our in situ TEM tensile experiments reveal the highly plastic behavior of the ALD shell, which withstands a maximum strain of 188%. Comparable samples under beam-off conditions show a brittle fracture, which underlines the effect of electron irradiation. The electron-beam-activated bond switching within the amorphous network enables compensation of the applied tensile strain, leading to viscous flow. By incorporating an intermediate nanocrystalline layer within the Al 2 O 3 shell, the plasticity is suppressed and brittle fracture occurs. This work directly demonstrates the tuning of mechanical properties in amorphous ALD structures through electron irradiation.

36 MATERIALS SCIENCE↗

A Review of Advanced Test Reactor Fuel and Assessment of Its Compatibility with the ZIRCEX Chlorination Process

Advanced Test Reactor (ATR) fuel has been identified as a resource for high-assay low-enriched uranium (HALEU) production. A survey was performed on the published literature describing ATR fuel. The geometry of the fuel is complex; different parts of the fuel compact experience differing neutron flux and burnup. The literature is sparse, and access is controlled. Therefore, fundamental studies of fuel reprocessing must use a model fuel that represents the main chemical and structural features. Advanced chlorination, or chlorination with sulfur-chlorine bearing reagents is being investigated as way to separate the fuel from metal matrix alloys. A UAl x alloy will be fabricated with x = 3, 4, and 5. The potential chlorination of individual UAl x intermetallics will be assessed in the advanced chlorination process of Al-8001 and Al-6061 as well as a representative mixture. Initial studies will track the alloying elements of the Al, which are Si, Fe, Cu, Mn, Mg, Cr, Zn, and Ti, in addition to the U itself. Further studies will include fission product simulants. Because advanced chlorination solvents include sulfur, the chemistry of sulfur with major and minor constituents will also be investigated. The experimental work accompanied by neutronic calculations will allow the assessment of the feasibility of advanced chlorination to separate aluminum from uranium. If bench-scale testing appears promising, then small-scale tests in shielded facilities with irradiated cladding, lightly irradiated fuel, and spent nuclear fuel are recommended to track the complete inventory of fissile actinides, fission product impurities, and reagent solids and liquids.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Multi-Tube Mixer Combustion for 65% Efficiency (Final Report)

This project targeted advanced low NOx combustion for advanced gas turbines capable of 65%, or greater, efficiency in combined cycle application. This technology advancement has further potential to benefit gas turbines used in coal based IGCC applications with pre-combustion carbon capture and hydrogen as the resulting fuel. The program developed and synthesized the most advanced combustion system capable of achieving low NOX emissions up to turbine inlet temperatures of 3100F while also supporting the load-following needs of a modern grid. The combustion system contributes to the overall gas turbine efficiency goal by setting the maximum cycle temperature achievable for a given NOX level and by minimizing the through-combustor air flow pressure drop. Focus areas for this project targeted maximizing the turbine inlet temperature entitlement, as constrained by emissions considerations. The design also minimized parasitic air flow pressure drop by using advanced cooling techniques and performance materials selections and by minimizing hot surface area. These two technology objectives (maximum, emissions-compliant cycle temperature and minimum air flow pressure drop) were integrated into a prototype design. The primarily analytical project sought to identify the most promising technologies to meet these objectives. Additional critical “jugular” data were obtained from multi-tube mixer tests to realize the potential of leveraging “micro flames” for minimizing overall hot surface area. This data was used, in conjunction with an understanding of advanced material and cooling design technologies, to analytically develop multiple design concepts. Phase I focused on in-depth engineering analysis and design, with minimal supporting laboratory testing to enable a selection of the top three combustion architectures for achieving these overall objectives. Phase II of the program developed the selected design through a combination of sub-scale testing and analytical efforts. Early tests included a cold-flow cascade to establish aerodynamic performance characteristics and a sub-scale fired test at GE Global Research in Niskayuna, NY, to establish cooling and heat transfer characteristics in conjunction with combustion performance. The data from these tests validated the analytical models to ultimately design a full-scale, test article to evaluate at prototypical pressure and temperature conditions at GE Gas Power’s Gas Turbine Technology Laboratory in Greenville, SC. GE Gas Power also developed, tested, and recommended a suitable seal design to be applied to the unique features of the combustor. To assess the technology challenges from prospective future production of the combustor from a ceramic matrix composite material, screening tests of Environmental Barrier Coatings were completed.

20 FOSSIL-FUELED POWER PLANTS↗

Effects of Riser Diameter on Solids Holdup and Particle Velocity Profiles in Circulating Fluidized Bed Riser Systems

Tests were performed in a 0.1-m diameter small circulating fluidized bed (SCFB) and 0.3 m diameter cold flow circulating fluidized bed (CFCFB) riser systems located at the National Energy Technology Laboratory (NETL) to study the effects of riser diameter on the riser hydrodynamics. These tests were performed at solids circulation rates of G s = 20 and 75 kg/m 2 s and superficial gas velocities of U g = 5.8 and 6.5 m/s using high-density polyethylene (HDPE) pellets with a density of 0.863 g/cm 3 , particle size range of 600–1400 µm (with a Sauter mean diameter of 871 µm, placing them in the Geldart B classification). Comparisons of riser axial pressure and solids fraction profiles, radial particle velocity profiles, and radial profiles of higher statistical moments and select chaos analysis parameters were considered. The results showed that for a given U g and G s , the smaller diameter riser exhibited characteristics associated with more dilute solids flow than that observed in the larger diameter riser. Additionally, the larger diameter riser exhibited a downward flow of solids near the wall under all test conditions, whereas the smaller diameter riser data exhibited little or no indications of solids downflow near the wall. Overall, these findings suggest that, from an industrial standpoint, a direct scaleup of small-scale tests cannot readily be accomplished as the solids holdup and the solids velocity profiles in small units (those normally tested in the laboratory) are not similar to those of large units and the performance of large units can therefore not be predicted from small-scale tests.

42 ENGINEERING↗

Investigation of thermal hydraulic behavior of the High Temperature Test Facility's lower plenum via large eddy simulation

A high-fidelity computational fluid dynamics (CFD) analysis was performed using the Large Eddy Simulation (LES) model for the lower plenum of the High–Temperature Test Facility (HTTF), a ¼ scale test facility of the modular high temperature gas-cooled reactor (MHTGR) managed by Oregon State University. In most next–generation nuclear reactors, thermal stress due to thermal striping is one of the risks to be curiously considered. This is also true for HTGRs, especially since the exhaust helium gas temperature is high. In order to evaluate these risks and performance, organizations in the United States led by the OECD NEA are conducting a thermal hydraulic code benchmark for HTGR, and the test facility used for this benchmark is HTTF. HTTF can perform experiments in both normal and accident situations and provide high-quality experimental data. However, it is difficult to provide sufficient data for benchmarking through experiments, and there is a problem with the reliability of CFD analysis results based on Reynolds–averaged Navier–Stokes to analyze thermal hydraulic behavior without verification. To solve this problem, high-fidelity 3-D CFD analysis was performed using the LES model for HTTF. It was also verified that the LES model can properly simulate this jet mixing phenomenon via a unit cell test that provides experimental information. As a result of CFD analysis, the lower the dependency of the sub-grid scale model, the closer to the actual analysis result. In the case of unit cell test CFD analysis and HTTF CFD analysis, the volume-averaged sub-grid scale model dependency was calculated to be 13.0% and 9.16%, respectively. As a result of HTTF analysis, quantitative data of the fluid inside the HTTF lower plenum was provided in this paper. As a result of qualitative analysis, the temperature was highest at the center of the lower plenum, while the temperature fluctuation was highest near the edge of the lower plenum wall. The power spectral density of temperature was analyzed via fast Fourier transform (FFT) for specific points on the center and side of the lower plenum. FFT results did not reveal specific frequency-dominant temperature fluctuations in the center part. It was confirmed that the temperature power spectral density (PSD) at the top increased from the center to the wake. The vortex was visualized using the well-known scalar Q-criterion, and as a result, the closer to the outlet duct, the greater the influence of the mainstream, so that the inflow jet vortex was dissipated and mixed at the top of the lower plenum. Additionally, FFT analysis was performed on the support structure near the corner of the lower plenum with large temperature fluctuations, and as a result, it was confirmed that the temperature fluctuation of the flow did not have a significant effect near the corner wall. In addition, the vortices generated from the lower plenum to the outlet duct were identified in this paper. It is considered that the quantitative and qualitative results presented in this paper will serve as reference data for the benchmark.

97 MATHEMATICS AND COMPUTING↗

Thermal-Hydrological-Mechanical Modelling of Stockton University Reservoir Cooling System, Fine Scale Stress Test Modelling

Mesh, properties, initial conditions, injection/withdrawal rates for modelling thermal, hydrological, and mechanical effects of fluid injection to and withdrawal from ground for Stockton University reservoir cooling system (aquifer storage cooling system), Galloway, New Jersey, for unscheduled two hour injection at 133 % designed capacity, on fine scale grid, with some results. Second simulation of J.T. Smith, E. Sonnenthal, P. Dobson, P. Nico, and M. Worthington, 2021. Thermal-hydrological-mechanical modeling of Stockton University reservoir cooling system, Proceedings of the 46th Workshop on Geothermal Reservoir Engineering, Stanford University, SGP-TR-218, from which Figures 6-9, pertain.

15 GEOTHERMAL ENERGY↗

Pilot-Scale Pelleting Tests on High-Moisture Pine, Switchgrass, and Their Blends: Impact on Pellet Physical Properties, Chemical Composition, and Heating Values

In this study, we evaluated the pelleting characteristics of southern yellow pine (SYP), switchgrass (SG), and their blends for thermochemical conversion processes, such as pyrolysis and gasification. Using a pilot-scale ring-die pellet mill, we specifically assessed the impact of blend moisture, length-to-diameter (L/D) ratio in the pellet die, and ratio of pine to SG on the physico-chemical properties of the resulting pellets. We found that an increase in pine content by 25–50% marginally affected the bulk density; however, it also led to an increase in calorific value by 7% and a decrease in ash content by 72%. A moisture content of 25% (wet basis) and an L/D ratio of 5 resulted in poor pellet durability at <90% and bulk density values of <500 kg/m 3 , but increasing the L/D ratio to 9 and lowering the moisture content to 20% (w.b.) improved the pellet durability to >90% and the bulk density to >500 kg/m 3 . Blends with ≥50% pine content resulted in lower energy consumption, while a lower L/D ratio resulted in higher pelleting energy. Based on these findings, we successfully demonstrated the high-moisture pelleting of 2.5 ton of pine top residues blended with SG at 60:40 and 50:50 ratios. The quality of the pellets was monitored off-line and at-line by near infrared (NIR) spectroscopy. Multivariate models constructed by combining the NIR data and the pelleting process variables could successfully predict the pine content (R 2 = 0.99), higher heating value (R 2 = 0.98), ash (R 2 = 0.95), durability (R 2 = 0.94), and bulk density (R 2 = 0.86) of the pellets. Thus, we established how blending and densification of SYP and SG biomass could improve feedstock specifications and that NIR spectroscopy can effectively monitor the pellet properties during the high-moisture pelleting process.

09 BIOMASS FUELS↗