Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampled value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Discerning Deception: An Empirically-Driven Agent-Based Model of Expert Evaluation of Scientific Content

Both human subject experiments and computational, modeling and simulations have been used to study detection of deception. This work aims to combine these two methods by integrating empirically-derived information (from human subject experiments) into agent-based models to generate novel insights into the complex problems of detection of disinformation content. Computational experiments are used to simulate across multiple scenarios for evaluation and decision-making regarding the validity of potentially deceptive scientific documents. Factors influencing the human agent behaviors in the model were identified through a human subject experiment that was conducted to evaluate and characterize decision making related to disinformation discernment. Correlation and regression analyses were used to translate insights from the human subjects experiment to inform the parameterization of agent features and scenario development. Three scenarios were evaluated with the agent-based models to help evaluate the replicability of the simulations (validation analysis) and assess the influence of human agent and document features (sensitivity analyses). A replication of the human participant experiment demonstrated that the agent-based simulations compare favorably to empirical findings. The agent-based modeling was then used to conduct sensitivity analysis on the accuracy of deception detection as a function of document proportions and human agent features. Results indicate that precision values are adversely impacted when the proportion of deceptive documents is lower in the overall sample, whereas recall values are more sensitive to changes in human agent features. These findings indicate important nuances in accuracy evaluations that should be further considered (including consideration of potential alternate metrics) in future agent-based models of disinformation. Additional areas for future exploration include extension of simulations to consider other ways to align the agent-based model design with psychological theory and inclusion of agent-agent interactions, especially as it pertains to sharing of scientific information within an organizational context.

99 GENERAL AND MISCELLANEOUS↗

The gallium isotopic composition of the Moon

Here, in this study, we present new Ga isotope data from a suite of 28 mare basalts and lunar highland rocks. The δ 71 Ga values of these samples range from -0.10 to +0.66‰ (where δ 71 Ga is the relative difference between the 71 Ga/ 69 Ga ratio of a sample and the Ga-IPGP standard), which is an order of magnitude more heterogeneous than δ 71 Ga values in terrestrial magmatic rocks. The cause of this isotopic heterogeneity must be established to estimate the bulk δ 71 Ga value of the Moon. In general, low-Ti basalts and ferroan anorthosite suite (FAS) rocks have δ 71 Ga values that are lower than high-Ti basalts and KREEP-rich rocks. The observation that rocks derived from later forming LMO cumulates have higher δ 71 Ga values suggests that Ga isotopes are fractionated by processes that operate within the chemically evolving LMO, rather than localized degassing or volatile redistribution. Correlations between indices of plagioclase removal from the LMO (e.g. Eu/Eu*) with Ga isotope ratios suggest that a Δ 71 Ga plagioclase-melt of -0.3‰, (where Δ 71 Ga plagioclase-melt is the isotopic fractionation associated with crystallization of plagioclase from a melt), could drive the observed isotopic fractionation in high-Ti mare basalts and KREEP-rich rocks. This would be consistent with the observation that FAS rocks have δ 71 Ga values that are lower than mare basalts. However, the addition of KREEP-like material into the mare basalt source regions would not contribute enough Ga to perturb the isotopic composition outside of analytical uncertainty. Thus, basalts derived from early formed LMO cumulates such as those from Apollo 15, would preserve light Ga isotopic compositions despite containing modest amounts of urKREEP. We estimate that the δ 71 Ga value of the LMO was ~0.14‰ prior to the onset of plagioclase crystallization and extraction. Whether this δ 71 Ga value is representative of the initial BSM cannot be ascertained from the current dataset. It remains plausible that the Moon accreted with a heavier Ga isotopic composition than the Earth. Alternatively, the Moon and Earth could have accreted with similar isotopic compositions (BSE = 0.00 ± 0.06‰, Kato et al., 2017) and volatile loss drove the LMO to higher δ 71 Ga values prior to formation of the lunar crust.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating the performance of a high resolution SLIM IM module integrated with an Agilent 6560 IM-QTOF MS - CRADA 413 (Final Report)

Developing new technologies that enhance our abilities to identify molecular signatures is important for the health of the public, the environment, and national security. Deploying these novel technologies requires multiple stages of validation and evaluation. This project focused on evaluating a technology developed at PNNL named Structures for Lossless Ion Manipulations (SLIM) in the context of a commercially available ion mobility mass spectrometer instrument from Agilent Technologies. There is a benefit to integrating the recently developed SLIM module into a real-world instrument platform. Data from the combined instrument will provide new standards for characterizing samples using ion mobility. These standards, related to both the drift time of ions and their resulting collisional cross sections (CCS) will be of value in characterizing samples from both humans and environmental samples, such as soil microbiomes. Because no previous instrument has been designed and implemented to simultaneously analyze the same sample in both constant and oscillating drift fields, the project will provide a new research capability that will support research in a wide variety of applications. The evaluation approach included measuring the resolving power, mass range, sensitivity, and accuracy of two SLIM variations (constant and oscillating fields). Although SLIM performed similarly to the commercial instrument in terms of sensitivity, mass range, and accuracy the resolving power of SLIM far exceeded that of the commercially-available instrument. This validation will provide critically useful data to our commercial partners which they can use to reach informed decisions on the advantages of the SLIM technology such as the outstanding performance and the low cost of manufacturing.

42 ENGINEERING↗

Operator-level quantum acceleration of non-logconcave sampling

Sampling from probability distributions of the form 𝝈 ∝ e −𝜷V , where V is a continuous potential, is a fundamental task across physics, chemistry, biology, computer science, and statistics. However, when V is nonconvex, the resulting distribution becomes non-logconcave, and classical methods such as Langevin dynamics often exhibit poor performance. We introduce a quantum algorithm that provably accelerates a broad class of continuous-time sampling dynamics. For Langevin dynamics, our method encodes the target Gibbs measure into the amplitudes of aquantum state, identified as the kernel of a block matrix derived from a factorization of the Witten Laplacian operator. This connection enables Gibbs sampling via singular value thresholding and yields up to a quartic quantum speedup over best-knownclassical Langevin-based methods in the non-logconcave setting. Building on this framework, we further develop the first quantum algorithm that accelerates replica exchange Langevin diffusion, a widely used method for sampling from complex, rugged energy landscapes.

97 MATHEMATICS AND COMPUTING↗

Merging Fungal and Bacterial Community Profiles via an Internal Control

Integrated measurements of fungi and bacteria are critical to understand how interactions between these taxa drive key processes in ecosystems ranging from soils to animal guts. High-throughput amplicon sequencing is commonly used to census microbiomes, but the genetic markers targeted for fungi and bacteria (typically ribosomal regions) are domain-specific so profiling must be performed separately, obscuring relationships between these groups. To solve this problem, we developed a spike-in method with an internal control (IC) construct containing primer sites commonly used for bacterial and fungal taxonomic profiling. The internal control offers several advantages: estimation of absolute abundances, estimation of fungal to bacterial ratios (F:B), integration of bacterial and fungal profiles for holistic community analysis, and lower costs compared to other quantitation methods. To validate the IC as a scaling method, we compared IC-derived measures of F:B to measures from quantitative PCR (qPCR) using a commercial mock community (the ZymoBiomic Microbial Community DNA Standard II, containing two fungi and eight bacteria) and complex environmental samples. For both the mock community and the environmental samples, the IC produced F:B values that were statistically consistent with qPCR. Merging the environmental fungal and bacterial profiles based on the IC-derived F:B values revealed new relationships among samples in terms of community similarity. As a result, this IC method is the first spike-in method to employ a single construct for cross-domain amplicon sequencing, offering more reliable measurements.

59 BASIC BIOLOGICAL SCIENCES↗

Electronic device and method for compressing sampled data

An electronic device for compressing sampled data comprises a memory element and a processing element. The memory element is configured to store sampled data points and sampled times. The processing element is in electronic communication with the memory element and is configured to receive a plurality of sampled data points, a slope for each sampled data point in succession, the slope being a value of a change between the sampled data point and its successive sampled data point, and store the sampled data point in the memory element when the slope changes in value from a previous sampled data point.

Morrow, Mitchell Hedges↗

Electronic device and method for compressing sampled data

An electronic device for compressing sampled data comprises a memory element and a processing element. The memory element is configured to store sampled data points and sampled times. The processing element is in electronic communication with the memory element and is configured to receive a plurality of sampled data points, a slope for each sampled data point in succession, the slope being a value of a change between the sampled data point and its successive sampled data point, and store the sampled data point in the memory element when the slope changes in value from a previous sampled data point.

Tohlen, Michael Aaron↗

Electronic device and method for compressing sampled data

An electronic device for compressing sampled data comprises a memory element and a processing element. The memory element is configured to store sampled data points and sampled times. The processing element is in electronic communication with the memory element and is configured to receive a plurality of sampled data points, a slope for each sampled data point in succession, the slope being a value of a change between the sampled data point and its successive sampled data point, and store the sampled data point in the memory element when the slope changes in value from a previous sampled data point.

Morrow, Mitchell Hedges↗

Simulation system for testing a radar system

A simulation system for use in testing a radar system comprises a coarse delay module, a fine delay module, and a doppler shift module. The coarse delay module is configured to receive a first stream of digital data samples that are sampled from a radar signal at a sample time period or a second stream of digital data samples that are processed by another simulation system component and delay the digital data samples by a selectable first delay time that is greater than or equal to the sample time period. The fine delay module is configured to receive the digital data samples and filter the digital data samples to represent delay by a selectable second delay time that is less than the sample time period. The doppler shift module is configured to receive the digital data samples and adjust a value of a frequency content of the fine delayed samples.

Chritton, Audrey L.↗

Evaluation of coal-associated sediments, wastes, and AMD sludge in the Southern Appalachian Basin as feedstock materials for REE and Li recovery

Critical minerals (CM) such as rare earth elements (REE+) and Lithium (Li) are essential to technological innovation, energy transitions, global economic and defense security, necessitating the search for unconventional resources and efficient recovery methods to avert supply chain disruptions. Here, this study evaluates coal-associated sediments (underclay and roof rock) and wastes from the Pennsylvanian Pottsville Formation of the Southern Appalachian Basin (SAB) as potential feedstocks for CM recovery. A total of 34 samples (15 underclays, 12 roof rocks, 5 Acid Mine Drainage (AMD) sludges, and 2 coal mining wastes) were characterized using XRD, XRF, ICP-MS, and μ-XRF analytical methods. The REE+ and Li concentrations of these materials ranged from 46.8 to 334.4 ppm and from 11.1 to 519 ppm, respectively, with one underclay sample (Hendrix 3456) yielding the highest values for both. Bulk mineralogy for all samples was dominated by aluminosilicate clay phases, particularly illite and kaolinite. All samples exhibited REY def, rel% values >26% and C outl indices that ranged from 0.69 to 0.94, classifying their REE ore potential as Category II (Promising) as defined by Seredin and Dai (2012). Extractability tests (EPA method 3051 A) yielded low REE+ and Li recoveries, with maximum values of 3.3% and 3.6%, respectively, suggesting associations with resistant minerals like clay and phosphates. Elemental mapping indicates that REE+ is associated with phosphate, whereas statistical analysis suggests that REE+ are associated with aluminosilicates, suggesting heterogeneous associations or minimal phosphate contribution. Li also correlated positively with Al 2 O 3 , indicating an aluminosilicate host. This study highlights the potential of coal-associated sediments in the SAB.

Clay minerals↗

Plasma proteomic biomarkers of physical frailty in heart failure: a propensity score matched discovery-based pilot study

Background: Physical frailty is highly prevalent in heart failure (HF), but we lack an understanding of the underlying pathophysiology. Proteomics evaluation of plasma samples may elucidate potential mechanisms and biomarkers of physical frailty in HF. We aimed to identify plasma proteomic biomarkers that are differentially expressed between physically frail and non physically frail adults with HF. Methods: This was a secondary analysis of a subset of data and plasma samples from a study of frailty among patients with New York Heart Association (NYHA) Functional Classification I-IV HF. Physical frailty was measured using the Frailty Phenotype Criteria. Propensity score matching was used to match pairs of physically frail (n = 20) vs. non-physically frail (n = 20) patients on clinical characteristics. Plasma samples were processed using a sensitive liquid chromatography mass spectrometry platform, utilizing a multiplexed tandem mass tag-labeled quantitative proteomics approach. Differentially expressed proteins were quantified individually using paired t tests with associated log fold change of 0.3 and Fisher’s combined p values. Results: The sample (n = 40) was 62.8±16.9 years old, 58% female, and 55% NYHA Class III/IV. Proteomics analysis revealed 7 proteins differentially expressed using full differential criteria: matrix metalloproteinase-14 was downregulated in frailty, and copine-1, low affinity immunoglobulin gamma Fc region receptor III-A and III-B, probable non-functional immunoglobulin kappa variable 2D-24, glutathione S-transferase Mu 1, and argininosuccinate lyase were upregulated in frailty. Conclusions: Proteomic biomarkers related to the immune system, stress response, and detoxification were differentially expressed between physically frail and non-physically frail adults with HF.

Biomarkers↗

Pool boiling critical heat flux studies of accident tolerant fuel cladding materials

Pool boiling experiments have been performed at atmospheric pressure on potential accident tolerant fuel (ATF) cladding materials (Zirlo®, Cr coated Zirlo®, FeCrAl coated Zirlo®, and monolithic SiC) to evaluate the Critical Heat Flux (CHF) points. Corrosion resistant coatings of Cr and FeCrAl alloy were deposited on flat Zirlo® samples using cold spray technology. The as-prepared samples after uniform surface polishing were subjected to autoclave tests at 360 °C water and 18.6 MPa for 360 h to simulate prototypic corrosion of the ATF cladding materials in LWR normal operation. Surface characteristics potentially influencing CHF such as surface morphology, roughness, static contact angle, and surface chemistry were characterized using a suite of characterization methods including scanning electron microscopy, 3D optical profilometry, optical contact angle measurements, and x-ray photoelectron spectroscopy (XPS). Thermo-physical properties of the samples such as density, thermal conductivity, and heat capacity were measured by differential scanning calorimetry and laser flash thermal diffusivity measurement. FeCrAl coatings showed CHF values comparable to bare Zirlo® samples, while slightly lower CHF values were observed for Cr coated samples and bulk SiC flats (produced by chemical vapor deposition, CVD). As-deposited Cr coatings showed 67% higher CHF than the as-polished Cr coatings due to its higher surface roughness level. The autoclave testing for the prepared samples generally increased the CHF except for the surface polished Cr coatings. Similar CHF values of bare Zirlo®, FeCrAl coating, and CVD SiC samples were observed after autoclave test but there were negligible change CHF of Cr coatings. XPS studies indicated that the formation or deposition of a few monolayers of hydrophobic carbonaceous species on surface can affect CHF values. The trends in CHF data are discussed in terms of evolution of the surface characteristics of the ATF materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comment on “Tunneling-tip-induced collapse of the charge gap in the excitonic insulator Ta 2 NiSe 5 ”

In this study, we investigate the discrepancy between the estimate of Q. He [], who observed a remarkable collapse of the exciton gap in Ta 2 NiSe 5 due to the electrostatic field between the scanning tunneling microscope (STM) tip and the sample, and that of a recent angle-resolved photoemission spectroscopy investigation [C. Chen , ]. It is proposed that a critical factor contributing to this discrepancy is due to He 's assumption of a constant work function of the STM tip. This assumption led to an underestimation of the tip-induced electric field. Using a literature value for the sample work function, a more substantial electric field strength is obtained, which resolves the apparent conflict between the doping estimates of these two techniques. Furthermore, our findings highlight the importance of the STM tip condition, which can significantly impact the tip work function and, consequently, influence the doping estimation in experiments involving tip-induced electric fields. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluating Manual Sampling Locations for Regulatory and Emergency Response

Drinking water systems commonly use manual or grab sampling to monitor water quality, identify or confirm issues, and verify that corrective or emergency response actions have been effective. In this paper, the effectiveness of regulatory sampling locations for emergency response is explored. An optimization formulation based on the literature was used to identify manual sampling locations to maximize overall nodal coverage of the system. Results showed that sampling locations could be effective in confirming incidents for which they were not designed. When evaluating sampling locations optimized for emergency response against regulatory scenarios, the average performance was reduced by 3%–4%, while using optimized regulatory sampling locations for emergency response reduced performance by 7%–10%. Secondary constraints were also included in the formulation to ensure geographical and water age diversity with minimal impact on the performance. This work highlighted that regulatory sampling locations provide value in responding to an emergency for these networks.

54 ENVIRONMENTAL SCIENCES↗

Interior soft x-ray tomography with sparse global sampling

To investigate the feasibility of interior imaging reconstruction in soft X-ray tomography for higher-resolution cellular imaging, including whole-cell imaging, we develop an alignment and reconstruction algorithm that combines a small number of sparse whole-cell images with a high-resolution local interior scan. Based on numerical simulations, we demonstrate that combined reconstructions mitigate the depth-of-field limitation in high-resolution scans, enable radiation dose optimization, and yield quantitative X-ray absorption values with sparse sampling. We further validate our numerical approach using experimental data from two different cell types and show that the combined reconstruction reliably provides high spatial resolution within an interior region of interest of a whole cell. The resulting sparse reconstruction framework offers robust, faithful visualization of cellular organelles in soft X-ray tomography. This mesoscale imaging strategy allows one to ‘scout’ and zoom into selected subcellular volumes of interest, enabling increased spatial resolution without sacrificing larger-volume imaging and providing information on the relative positions of all organelles within a cell.

3D imaging↗

Joint Sample Analyses of Nuclear Forensic Materials Provided by the Republic of Kazakhstan: U. S. Laboratory Results

This document serves as an interim report to summarize sample analyses performed by Lawrence Livermore National Laboratory (LLNL) and Los Alamos National Laboratory (LANL) on a series of five nuclear forensics samples provided by the Institute of Nuclear Physics (INP) in the Republic of Kazakhstan. The sample set contains four uranium oxide powders and one low-enriched uranium fuel pellet. The samples were provided as part of a broader collaboration that involved a set of joint sample analyses conducted by INP and the US National Laboratories. The joint analyses are being conducted using well-developed analytical plans. These activities are designed to support the advancement of nuclear forensic science and capacity building in all three institutes in both countries. This report builds upon an earlier preliminary summary of the joint interactions and will be augmented by a final report. The final report will summarize the results and value of all sample analyses performed at the three institutes (INP, LLNL, and LANL). The final report will also provide an intercomparison of the results, analytical methods and best practices employed, as well as outline future collaborative nuclear forensics activities that are being developed in the Kazakhstan region.

and nuclear chemistry↗

High throughput, spatially resolved thermal properties measurement using attachable and reusable 3ω sensors

The 3ω method is a well-established thermal technique used to measure the thermal conductivity of materials and the thermal resistance of interfaces. It has significant advantages over other steady state and transient thermal techniques in its ability to provide spatially resolved thermal property measurements over a wide range of thermal conductivity. Despite its advantages, it has been restricted to lab-scale use because of the difficulty involved in sample preparation and sensor fabrication and is limited to non-metallic substrates. High-throughput 3ω measurements with reusable sensors have not been realized yet. In this work, we demonstrate a method of applying reusable 3ω sensors fabricated on flexible polyimide films to measure bulk and spatially resolved thermal properties. Here, we establish the limits of thermal conductivity measurement with the method to be 1 to 200 W/mK, and within the measurement limit, we verify the method by comparing the measured thermal conductivities of standard samples with established values. From the 3ω measurements, we also determine the thermal resistance of an interlayer of thermal grease as a function of pressure and compare it against the resistance calculated from direct thickness measurements to demonstrate the ability of this method to provide spatially resolved subsurface information. The technique presented is general and applicable to both metallic and non-metallic substrates, providing a method for high-throughput 3ω measurements with reusable sensors and without considerable sample preparation.

47 OTHER INSTRUMENTATION↗