Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sag”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

AmeriFlux FLUXNET-1F US-Fo1 Flux Observations of Carbon from an Airborne Laboratory (FOCAL) Campaign Site 1

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Fo1 Flux Observations of Carbon from an Airborne Laboratory (FOCAL) Campaign Site 1. This is the FLUXNET version of the carbon flux data for the site US-Fo1 Flux Observations of Carbon from an Airborne Laboratory (FOCAL) Campaign Site 1 produced by applying the standard ONEFlux (1F) software. Site Description - This tower is locate south of Prudhoe Bay off the Dalton Highway along the Sagavanirktok (Sag) River. Landcover at the site is wetsedge (based on NSSI land cover map). During the first campaign (2013-2014), the tower location was 70.085450N; -148.570160W. It was moved to the current location (70.085050N, 148.567090W) during 2022 to 2024.

Krishnan, Praveena [NOAA/ARL/ATDD]↗

AmeriFlux FLUXNET-1F US-Fo2 Flux Observations of Carbon from an Airborne Laboratory (FOCAL) Campaign Site 2

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Fo2 Flux Observations of Carbon from an Airborne Laboratory (FOCAL) Campaign Site 2. This is the FLUXNET version of the carbon flux data for the site US-Fo2 Flux Observations of Carbon from an Airborne Laboratory (FOCAL) Campaign Site 2 produced by applying the standard ONEFlux (1F) software. Site Description - This tower is locate south of Prudhoe Bay off the Dalton Highway along the Sagavanirktok (Sag) River

Krishnan, Praveena [NOAA/ARL/ATDD]↗

Hourly dynamic line ratings for existing transmission across the contiguous United States (preliminary results) [Slides]

The thermal rating of a transmission line depends on the rate at which heat generated by current flow through the line can be dissipated into the environment by convective and radiative cooling, keeping the conductor below a maximum operating temperature. Static or seasonal line ratings assume nearly-worst-case weather conditions (high ambient air temperature, high solar irradiance, and low wind speed), resulting in a low risk of "overrating" a line (i.e., allowing more current to flow than the line is designed for) but a high fraction of time when the line is "underrated" (i.e., able to flow more current while staying below the maximum temperature). Dynamic transmission line ratings (DLR) use real-time measurements of weather conditions, line sag, or line temperature to determine the thermal rating of transmission lines at hourly or higher time resolution, allowing for increased ratings during some (cold, windy, and/or dark) periods and correcting for overrating during other (hot, calm, and/or sunny) periods. Many studies have explored the benefits of DLR, but typically for small collections of transmission lines under a limited sample of weather conditions, leaving open the question of how widely applicable the benefits of DLR might be over diverse geographies and weather conditions. Here, we combine geospatial data on tens of thousands of transmission line routes across the contiguous United States with high-resolution hourly historical weather data for 2007-2013 to estimate the impact of DLR and other weather-adjusted rating systems. We compare static and dynamic line ratings to intermediate ratings adjusted by ambient temperature, day/night irradiance, clear-sky irradiance, and/or measured irradiance, illustrating the benefits of incorporating progressively more detailed weather data into the calculated line ratings. Moving from nighttime-adjusted ratings to clear-sky-adjusted ratings provides more benefit than moving from clear-sky-adjusted ratings to measured-irradiance-adjusted ratings. Depending on the assumed static windspeed for irradiance-adjusted-ratings, DLR either corrects for overrated hours or provides substantially increased ratings in the majority of hours on the majority of lines.

14 SOLAR ENERGY↗

A Review on Protection Challenges on Transmission Lines Connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses. Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

A review on protection challenges of Transmission Lines connected to Inverter Based Resources

The increased penetration of inverter-based resources (IBRs) connected to transmission grids is challenging how traditional electric power systems operate. Such systems were originally designed based on the dominant presence of synchronous generators. Some main challenges include the increased concerns about system stability due to the reduced system inertia caused by IBRs and the reduced protection reliability caused by the non-deterministic fault current response of IBRs. The protection relays’ algorithms have been designed and validated based on well-known fault current characteristics of synchronous generations, while the short-circuit responses of IBRs heavily depend on their vendor-specific control schemes, which are mainly set to protect inverter semiconductor switches and DC components. The magnitude of short current that IBRs contribute is typically between 1.1–1.5 times the rated current that may behave unstably and incoherently with the voltages. The control scheme of the IBRs also controls the active (P) and reactive (Q) support during system voltage sag and swell conditions. These characteristics challenge not only protective relay schemes but also existing short-circuit software tools to correctly model IBRs for fault studies and protection coordination analyses.

14 SOLAR ENERGY↗

Development of Scalable Coastal and Offshore Macroalgal Farming

The US DOE/ARPA-E MARINER program funded a four-year project to determine an optimal way to grow kelps in large, nearshore and offshore arrays for the eventual purpose of biofuel production with the goal of keeping the cost below $\$$80 USD per dry metric ton of kelp. This project specifically looked at how Saccharina latissima can be grown in the Gulf of Alaska to reach that goal. There were three major aspects of the research: 1) optimizing nursery production and seeding lines for outplanting, 2) designing an economical, modular outplanting structure and 3) developing methods to efficiently harvest the product. Farm designs were based on catenary structures and the use of spreader bars with variable spacing of grow lines and line types. The spacing of the grow lines makes a difference in the yield. Grow line spacing of ≥1.5m showed about a 50% increase in kg/m. There was no statistical difference in the growth of Saccharina latissima whether in the middle or the outside of the array, but the line type and perhaps line thickness can make a difference in yield. Sagging caused by the weight of the mature fronds resulted in lower growth at depth. Various harvesting approaches for mature kelps were tested by collaborating farmers. One promising innovation is the use of large bags for holding the freshly harvested fronds. Although the weight of the fronds on the growlines causes the lines to sink, the bags packed with the harvested fronds float, allowing for easy loading to the transfer vessel. Another advance in harvesting is a specially built harvest vessel, the Harvest Buddy, allowing a more mechanized and faster way to harvest. A significant aspect of this project was the TTO/T2M. Several different outreach activities were performed by the Alaska Fisheries Development Foundation and GreenWave. A techno-economic assessment (TEA) using our data has pointed to solutions to reach the $\$$80 goal. A second phase of this project involved the co-culture of two different species of kelps. Interest in farming kelps has grown beyond using kelp for food, feed or biofuels. There is considerable interest in generating biomass from seaweed for use in bioplastics and other products that would substitute for petroleum-derived products. For these uses to be viable, large amounts of biomass are needed. Very large kelp farms can be expensive to build and maintain, leading to the need to optimize the biomass per unit area. Although close spacing of growlines can lead to poor growth, a viable approach may be to grow two species of kelps together: one that hangs down and one that is buoyant, growing up. This system would increase the spacing in three dimensions. In Alaska, Saccharina latissima is commonly grown hanging down from longlines. One of the buoyant Alaskan kelps is Nereocystis luetkeana. Because there are commercial uses for wild-harvested Nereocystis in Alaska, we undertook a preliminary trial in Kodiak, Alaska that grew both Saccharina and Nereocystis in the same longline array. Closely spaced lines were seeded the first week of February 2023 and set at 3m below the surface. The arrays were harvested in late June 2023. Despite having 45% fewer grow-lines, the total yield of the Nereocystis on the combined arrays was statistically similar to the Nereocystis only arrays. Total yields were greatest on the combined arrays, followed by the Nereocystis only and Saccharina only arrays. These results may have significance for large scale macroalgal production.

09 BIOMASS FUELS↗

Mechanical Solutions Scan Report

Power lines, poles, and towers are the backbone of the United States (U.S.) electric-power grid. These transmission and distribution networks route electricity from generator to loads. The characteristics of these routes are rapidly changing -- trending towards decentralized renewable generation, electric heating, vehicle charging, and large data-center loads. Coupled with aging infrastructure and the increased frequency of extreme weather events, there is concern about the future reliability and transmission capacity of conductors and adjacent components. This scan report seeks to provide an overview of mechanical solutions to challenges caused by extreme weather events associated with components of transmission and distribution infrastructure, including conductor heat sag, ice accumulation, wind, and wildfire. Many options could increase transmission capacity or reliability, and these are at various stages of technological readiness. Some have only been lab tested, while some have been widely deployed in the U.S. or overseas for decades. The solution categories and providers featured in this report are intended to be comprehensive at the time of publication and to serve as a reference for decision-makers concerned about transmission and distribution reliability. There are two other categories of large, complex solutions, which are not covered in this report: replacing existing conductors with advanced conductors and implementing digital grid enhancing technologies. A separate scan report titled “Advanced Conductor Scan Report,” which discusses advanced carbon-core conductors, was published by the Idaho National Laboratory (INL) in 2023. Information on digital technologies, such as dynamic line ratings, power-flow controllers, and other power electronics and communications-based devices, can be found on the Grid- Enhancing Technologies landing page. Mechanical grid-enhancing technologies, or solutions covered in this report, often do not require full equipment replacement and do not rely on digital components. Mechanical technologies are overlooked because they may be older, simpler, or seemingly “more obvious” than digital or carbon-core technologies. However, it is wise to consider mechanical solutions in a thorough evaluation of grid enhancing technology solutions.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Computational Analysis of Hydraulic Efficiency of Michigan DOT Covers J and K

Drainage structures are used in urban street and highway systems to capture stormwater runoff. These structures typically consist of catch basins fitted with grates, inlets, or combination grate/inlet configurations that collect runoff and convey it through buried drainage systems. They are strategically placed within curb-and-gutter systems to enhance public safety by efficiently removing water from roadways and thereby reducing the risk of hydroplaning. The performance of drainage structures is commonly evaluated in terms of hydraulic efficiency, defined as the percentage of flow captured by the basin relative to the total flow reaching the structure. Understanding the hydraulic performance of these structures allows designers to properly space inlets, resulting in cost-effective designs that also help ensure the safety of the traveling public. MDOT uses a variety of drainage structures for runoff capture, as documented in Michigan Department of Transportation (MDOT) Drainage Manual. Many of these structures incorporate sinusoidal-type grates that are not addressed in HEC-22. Because physical modeling of these structures has been limited, further analysis is needed to verify their capture efficiency. Under current MDOT practice, the capture efficiency of these grates is estimated by assuming performance similar to that of a comparably sized reticuline grate described in HEC22. The first phase of this effort, titled Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C, focused on evaluating the hydraulic performance of MDOT’s Cover C grate. Cover C was selected as the initial test candidate because its sinusoidal pattern is representative of other MDOT grates, while it is typically used in high-volume, higher-speed applications. A similar version, Cover CX, is used on interstate highways but does not include transverse bars for bicycle safety. The current second phase of the study expands this work to evaluate MDOT’s Covers J and K. These grates were selected for additional analysis to further assess the hydraulic performance of MDOT drainage structures that are not directly represented by grate configurations in HEC-22. The results of this phase will build on the findings from the Cover C analysis and support improved understanding of the capture efficiency of MDOT’s standard drainage grates. This report is intended to serve as a companion document to the earlier study, Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C [3]. The present work applies the same overall CFD-based evaluation approach to MDOT Covers J and K and compares the resulting performance trends with those previously identified for Cover C. In particular, both studies assess on-grade interception efficiency, sag-location hydraulic capacity, and the effects of partial obstruction relative to HEC-22-based design estimates.

42 ENGINEERING↗

Passive Islanding Detection of Inverter-Based Resources in a Noisy Environment

Islanding occurs when a load is energized solely by local generators and can result in frequency and voltage instability, changes in current, and poor power quality. Poor power quality can interrupt industrial operations, damage sensitive electrical equipment, and induce outages upon the resynchronization of the island with the grid. This study proposes an islanding detection method employing a Duffing oscillator to analyze voltage fluctuations at the point of common coupling (PCC) under a high-noise environment. Unlike existing methods, which overlook the noise effect, this paper mitigates noise impact on islanding detection. Power system noise in PCC measurements arises from switching transients, harmonics, grounding issues, voltage sags and swells, electromagnetic interference, and power quality issues that affect islanding detection. Transient events like lightning-induced traveling waves to the PCC can also introduce noise levels exceeding the voltage amplitude by more than seven times, thus disturbing conventional detection techniques. The noise interferes with measurements and increases the nondetection zone (NDZ), causing failed or delayed islanding detection. The Duffing oscillator nonlinear dynamics enable detection capabilities at a high noise level. The proposed method is designed to detect the PCC voltage fluctuations based on the IEEE standard 1547 through the Duffing oscillator. For the voltages beyond the threshold, the Duffing oscillator phase trajectory changes from periodic to chaotic mode and sends an islanded operation command to the inverter. The proposed islanding detection method distinguishes switching transients and faults from an islanded operation. Experimental validation of the method is conducted using a 3.6 kW PV setup.

Energy & Fuels↗

Proceedings of the 2nd Columbia River Basalt Symposium: Maar volcanoes

Examination of maar-type volcanic cones, including tuff rings, from more than 40 localities in western North America indicates that water had access to volcano orifices during their activity. The most convincing evidence is the abundance of sideromelane (chilled basaltic glass) or its palagonitic decomposition products in the ejecta. Moreover, the volcanoes which were examined erupted in basins that either contained surface water, or else they grew above highly permeable aquifers at shallow dept. Characteristic features of maar ejecta are continuous thin beds, undulations and antidunes characteristic of base surge stratification, abundant accretionary lapilli or mud-armored rock particles, bedding sags that show soft sediment deformation, and in the subaqueous parts of the maar ramparts, great piles of subtly graded thin lenses of hyaloclastic debris.

Waters, A. C.↗

Cooling and evolution of a supernova remnant.

Discussion of the structure, evolution, and cooling of an old supernova remnant, aimed at providing a theoretical framework for relating remnants with similar energies and environments but of different ages. Discussed evolution details include the Sedov-Taylor blast wave, the electron-ion equipartition and thermal conduction, the temperature sag and the dynamics in the process of transition to a dense shell, and the history of remnant luminosity.

Cox, D. P.↗

Microcraters formed in hot glass by hypervelocity projectiles

Microcraters were formed in heated soda-lime glass by the normal incidence of spheres of plastic or fused silica with diameters between 0.8 and 4.5 microns and velocities between 2.5 and 10 km/s. The morphology of the craters in targets at temperatures up to 800 C is little different from those formed in unheated glass. Spallation still occurs to the same extent and above the same velocity threshold, but the spalls sag and sharp edges become dull in a few seconds at temperatures above the softening point. There is a small increase in the flow of glass from the central pit into a narrow lip at the higher temperatures, but this lip is often removed by spallation, especially at the higher velocities of impact. There is no evidence of a splashed lip with strings of melt overlying the spalled area. The results in conjunction with other evidence suggest that most lunar craters of micrometer size with a smooth central pit, splashed lip, and a spallation zone are the result of primary impacts.

Vedder, J. F.↗

Voltage profile program for the Kennedy Space Center electric power distribution system

The Kennedy Space Center voltage profile program computes voltages at all busses greater than 1 Kv in the network under various conditions of load. The computation is based upon power flow principles and utilizes a Newton-Raphson iterative load flow algorithm. Power flow conditions throughout the network are also provided. The computer program is designed for both steady state and transient operation. In the steady state mode, automatic tap changing of primary distribution transformers is incorporated. Under transient conditions, such as motor starts etc., it is assumed that tap changing is not accomplished so that transformer secondary voltage is allowed to sag.

Source record↗

Flicking-wire drag tensioner

Wire-drag system improves wire profile and applies consistent drag to wire. Wire drag is continuously adjustable from zero drag to tensile strength of wire. No-sag wire drag is easier to thread than former system and requires minimal downtime for cleaning and maintenance.

Dassele, M. A.↗

Criteria for evaluation of reflective surface for parabolic dish concentrators

Commercial, second surface glass mirror are emphasized, but aluminum and metallized polymeric films are also included. Criteria for sealing solar mirrors in order to prevent environmental degradation and criteria for bonding sagged or bent mirrors to substrate materials are described. An overview of the technical areas involved in evaluating small mirror samples, sections, and entire large gores is presented. A basis for mirror criteria was established that eventually may become part of inspection and evaluation techniques for three dimensional parabolic reflective surfaces.

Bouquet, F.↗

Epoxy Grout With Silica Thickener

Grout cures quickly, even in presence of hydraulic oil. Grout is mixture of aggregate particles, finely-divided silica, epoxy resin, and triethylenetetramine curing agent, with mixture containing about 85 percent silica and aggregate particle sand 15 percent resin and curing agent. Silica is thickening agent and keeps grout from sagging.

Mcclung, C. E.↗

Antenna grout replacement system

An epoxy grout suitable for use in mounting and positioning bearing runner plates used in hydrostatic bearing assemblies for rotatably mounting large radio telescope structures to stationary support pedestals is described. The epoxy grout may be used in original mountings or may be used as part of a replacement system for repairing cavities in existing grout resulting from grout deterioration. The epoxy grout has a relatively short work life and cure time even in the presence of hydraulic oil. The epoxy grout cures without shrinking or sagging to form a grout which is sufficiently strong and durable to provide a grout especially well suited for use under the high pressure loading and close tolerance requirements of large hydrostatic bearing assemblies.

Mcclung, C. E.↗