DER Inverter Control Fault Ride Through Model in Accordance with IEEE 1547-2018 Std

Distributed Energy Resources (DER) with smart inverters are becoming more prevalent as the need for renewable energy and grid stability increases. An important challenge arises when considering that inverterbased generation methods contribute less current during faults, rendering traditional overcurrent protection unsatisfactory. DERs have fault ride-through requirements when operating in high or low voltage, outlined by IEEE Std. 1547-2018. Faults cause the voltage to reach abnormal steady state magnitudes, depending on the fault resistance and fault type. There are several high voltage and low voltage ride-through zones defined by IEEE Std. 1547-2018. Each zone’s ride through duration decreases as the applicable voltage measurement, i.e., the phase RMS voltage, deviates from its nominal value. This presentation demonstrates the implementation of IEEE Std. 1547-2018 high and low voltage ridethrough grid support functions using a preexisting RSCAD model, discussing the challenges presented during this process. The implemented controls monitor the filtered phase voltages to have a more accurate reading of the applicable voltages. The controls sense the duration that the applicable voltage remains in a specific zone. The breaker trips and ceases energization to the grid when the duration is exceeded. The standard allows the operator to adjust the ride-through times and voltage zones from the default settings. These ranges are implemented into the runtime, which acts as the operator’s SCADA. The results show the accuracy of the voltage measurements, which remain within the IEEE Std. 1547-2018 for all cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mechanical ventilation and indoor air quality in recently constructed U.S. homes in marine and cold-dry climates

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and the Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO 2 , PM2.5 and radon; and time-integrated NO 2 , NO X and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2–2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO 2 and NO (NO X -NO 2 ) when operated with WHMV, and had faster PM 2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19% vs 3%) felt their IAQ could be improved and more reported dryness as a problem (58% vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Run-Time Verification Framework for Smart Grid Applications Implemented on Simulation Frameworks

Smart grid applications are implemented and tested with simulation frameworks as the developers usually do not have access to large sensor networks to be used as a test bed. The developers are forced to map the implementation onto these frameworks which results in a deviation between the architecture and the code. On its turn this deviation makes it hard to verify behavioral constraints that are de- scribed at the architectural level. We have developed the ConArch toolset to support the automated verification of architecture-level behavioral constraints. A key feature of ConArch is programmable mapping for architecture to the implementation. Here, developers implement queries to identify the points in the target program that correspond to architectural interactions. ConArch generates run- time observers that monitor the flow of execution between these points and verifies whether this flow conforms to the behavioral constraints. We illustrate how the programmable mappings can be exploited for verifying behavioral constraints of a smart grid appli- cation that is implemented with two simulation frameworks.

Architecture baed testing↗

Hydro-frac monitoring using ground time-domain electromagnetics: Hydro-frac monitoring using ground time-domain EM

& Engineers. As motivation for considering new electromagnetic techniques for hydraulic fracture monitoring, we develop a simple financial model for the net present value offered by geophysical characterization to reduce the error in stimulated reservoir volume calculations. Additionally, this model shows that even a 5% improvement in stimulated reservoir volume for a 1 billion barrel (bbl) field results in over 1 billion U.S. dollars (US$) in net present value over 24 years for US$100/bbl. oil and US$0.5 billion for US$50/bbl. oil. The application of conductivity upscaling, often used in electromagnetic modeling to reduce mesh size and thus simulation runtimes, is shown to be inaccurate for the high electrical contrasts needed to represent steel-cased wells in the earth. Fine-scale finite-difference modeling with 12.22-mm cells to capture the steel casing and fractures shows that the steel casing provides a direct current pathway to a created fracture that significantly enhances the response compared with neglecting the steel casing. We consider conductively enhanced proppant, such as coke-breeze-coated sand, and a highly saline brine solution to produce electrically conductive fractures. For a relatively small frac job at a depth of 3 km, involving 5,000 bbl. of slurry and a source midpoint to receiver separation of 50 m, the models show that the conductively enhanced proppant produces a 15% increase in the electric field strength (in-line with the transmitter) in a 10-Ωm background. In a 100-Ωm background, the response due to the proppant increases to 213%. Replacing the conductive proppant by brine with a concentration of 100,000-ppm NaCl, the field strength is increased by 23% in the 100-Ωm background and by 2.3% in the 10-Ωm background. Finally, all but the 100,000-ppm NaCl brine in a 10-Ωm background produce calculated fracture-induced electric field increases that are significantly above 2%, a value that has been demonstrated to be observable in field measurements. © 2015 European Association of Geoscientists

58 GEOSCIENCES↗

Comfort in High-Performance Homes in a Hot-Humid Climate

"9IBACOS monitored 37 homes during the late summer and early fall of 2014 in a hot and humid climate to better understand indoor comfort conditions. These homes were constructed in the last several years by four home builders that offered a comfort and performance guarantee for the homes. The homes were located in one of four cities: Tampa, Florida; Orlando, Florida; Houston, Texas; and San Antonio, Texas. Temperature and humidity data were collected from the thermostat and each room of the house using small, battery-powered data loggers. To understand system runtime and its impact on comfort, supply air temperature also was measured on a 1-minute interval. Overall, the group of homes only exceeded a room-to-room temperature difference of 6 degrees F for 5% of the time. For 80% of the time, the rooms in each house were within 4 degrees F of each other. Additionally, the impact of system runtime on comfort is discussed. Finally, measurements made at the thermostat were used to better understand the occupant operation of each cooling system's thermostat setpoint. Builders were questioned on their perceived impact of offering a comfort and performance guarantee. Their feedback, which generally indicates a positive perception, has been summarized in the report.

"9residential↗

Comfort in High-Performance Homes in a Hot-Humid Climate

IBACOS monitored 37 homes during the late summer and early fall of 2014 in a hot and humid climate to better understand indoor comfort conditions. These homes were constructed in the last several years by four home builders that offered a comfort and performance guarantee for the homes. The homes were located in one of four cities: Tampa, Florida; Orlando, Florida; Houston, Texas; and San Antonio, Texas. Temperature and humidity data were collected from the thermostat and each room of the house using small, battery-powered data loggers. To understand system runtime and its impact on comfort, supply air temperature also was measured on a 1-minute interval. Overall, the group of homes only exceeded a room-to-room temperature difference of 6 degrees Fahrenheit for 5% of the time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tool coupling for the design and operation of building energy and control systems based on the Functional Mock-up Interface standard

This paper describes software tools developed at the Lawrence Berkeley National Laboratory (LBNL) that can be coupled through the Functional Mock-up Interface standard in support of the design and operation of building energy and control systems. These tools have been developed to address the gaps and limitations encountered in legacy simulation tools. These tools were originally designed for the analysis of individual domains of buildings, and have been difficult to integrate with other tools for runtime data exchange. The coupling has been realized by use of the Functional Mock-up Interface for co-simulation, which standardizes an application programming interface for simulator interoperability that has been adopted in a variety of industrial domains. As a variety of coupling scenarios are possible, this paper provides users with guidance on what coupling may be best suited for their application. Furthermore, the paper illustrates how tools can be integrated into a building management system to support the operation of buildings. These tools may be a design model that is used for real-time performance monitoring, a fault detection and diagnostics algorithm, or a control sequence, each of which may be exported as a Functional Mock-up Unit and made available in a building management system as an input/output block. We anticipate that this capability can contribute to bridging the observed performance gap between design and operational energy use of buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of native Earth system model output with ESMValTool v2.6.0

Earth system models (ESMs) are state-of-the-art climate models that allow numerical simulations of the past, present-day, and future climate. To extend our understanding of the Earth system and improve climate change projections, the complexity of ESMs heavily increased over the last decades. As a consequence, the amount and volume of data provided by ESMs has increased considerably. Innovative tools for a comprehensive model evaluation and analysis are required to assess the performance of these increasingly complex ESMs against observations or reanalyses. One of these tools is the Earth System Model Evaluation Tool (ESMValTool), a community diagnostic and performance metrics tool for the evaluation of ESMs. Input data for ESMValTool needs to be formatted according to the CMOR (Climate Model Output Rewriter) standard, a process that is usually referred to as “CMORization”. While this is a quasi-standard for large model intercomparison projects like the Coupled Model Intercomparison Project (CMIP), this complicates the application of ESMValTool to non-CMOR-compliant climate model output. In this paper, we describe an extension of ESMValTool introduced in v2.6.0 that allows seamless reading and processing of “native” climate model output, i.e., operational output produced by running the climate model through the standard workflow of the corresponding modeling institute. This is achieved by an extension of ESMValTool's preprocessing pipeline that performs a CMOR-like reformatting of the native model output during runtime. Thus, the rich collection of diagnostics provided by ESMValTool is now fully available for these models. For models that use unstructured grids, a further preprocessing step required to apply many common diagnostics is regridding to a regular latitude–longitude grid. Extensions to ESMValTool's regridding functions described here allow for more flexible interpolation schemes that can be used on unstructured grids. Currently, ESMValTool supports nearest-neighbor, bilinear, and first-order conservative regridding from unstructured grids to regular grids. Example applications of this new native model support are the evaluation of new model setups against predecessor versions, assessing of the performance of different simulations against observations, CMORization of native model data for contributions to model intercomparison projects, and monitoring of running climate model simulations. For the latter, new general-purpose diagnostics have been added to ESMValTool that are able to plot a wide range of variable types. Currently, five climate models are supported: CESM2 (experimental; at the moment, only surface variables are available), EC-Earth3, EMAC, ICON, and IPSL-CM6. As the framework for the CMOR-like reformatting of native model output described here is implemented in a general way, support for other climate models can be easily added.

58 GEOSCIENCES↗

Hydronic Heating Retrofits for Low-Rise Multifamily Buildings: Boiler Control Replacement and Monitoring

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of the heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predicting runtime and resource utilization of jobs on integrated cloud and HPC systems

Recent advances in virtualization technologies used in cloud computing offer performance that closely approaches bare-metal levels. Combined with specialized instance types and high-speed networking services for cluster computing, cloud platforms have become a compelling option for high-performance computing (HPC). However, most current batch job schedulers in HPC systems are designed for homogeneous clusters and make decisions based on limited information about jobs and system status. Scientists typically submit computational jobs to these schedulers with a requested runtime that is often over- or under-estimated. More accurate runtime predictions can help schedulers make better decisions and reduce job turnaround times. Here, they can also support decisions about migrating jobs to the cloud to avoid long queue wait times in HPC systems.

97 MATHEMATICS AND COMPUTING↗

A Path to Operating System and Runtime Support for Extreme Scale Tools

In this project, we cast distributed resource access as operations on files in a global name space and developed a common, scalable solution for group operations on distributed processes and files. The resulting solution enables tool and middleware developers to quickly create new scalable software or easily improve the scalability of existing software. The cornerstone of the project was the design of a new programming idiom called group file operations that eliminates iterative behavior when a single process must apply the same set of file operations to a group of related files. To demonstrate our novel and scalable ideas for group file operations and global name space composition, we developed a group file system called TBON-FS that leverages a tree-based overlay network (TBON), specifically MRNet, for logarithmic communication and distributed data aggregation. We also developed proc++, a new synthetic file system co-designed for use in scalable group file operations. Over the course of the project, we evaluated the utility and performance of group file operations, global name space composition, TBON-FS, and proc++ in three case studies. The first study focused on the ease in using group file operations and TBON-FS to quickly develop several new scalable tools for distributed system administration and monitoring. The second study evaluated the integration of group file operation and TBON-FS within the Ganglia Distributed Monitoring System to improve its scalability for clusters. The final study involved the integration of group file operations, TBON-FS, and proc++ within TotalView, the widely-used parallel debugger. For this project, the work of the Oak Ridge National Laboratory (ORNL) team occurred primarily in two directions: bringing the MRNet tree-based overlay network (TBON) implementation to the Cray XT platform, and investigating techniques for predicting the performance of MRNet topologies on such systems. Rogue Wave Software (RWS), formerly TotalView Technologies Inc., worked with the University ofWisconsin (UW) team on the design and prototyping of a scalable version of the TotalView debugger. RWS assisted UW with their "proc++" design effort. RWS assisted UW with strategy for integrating proc++ into TotalView.

97 MATHEMATICS AND COMPUTING↗

Solving k –SAT problems with generalized quantum measurement

We generalize the projection–based quantum measurement–driven k –SAT algorithm of Benjamin, Zhao, and Fitzsimons to arbitrary strength quantum measurements, including the limit of continuous monitoring. In doing so, we clarify that this algorithm is a particular case of the measurement–driven quantum control strategy elsewhere referred to as “Zeno dragging”. We argue that the algorithm is most efficient with finite time and measurement resources in the continuum limit, where measurements have an infinitesimal strength and duration. Moreover, for solvable k -SAT problems, the dynamics generated by the algorithm converge deterministically towards target dynamics in the long–time (Zeno) limit, implying that the algorithm can successfully operate autonomously via Lindblad dissipation, without detection. We subsequently study both the conditional and unconditional dynamics of the algorithm implemented via generalized measurements, quantifying the advantages of detection for heralding errors. These strategies are investigated first in a computationally–trivial 2-qubit 2-SAT problem to build intuition, and then we consider the scaling of the algorithm on 3-SAT problems encoded with 4–10 qubits. We numerically investigate the scaling of 3-SAT with respect to algorithmic runtime and find that the optimized time to solution scales with qubit number n as λ n , where λ is slightly larger than $\sqrt{2}$ for unconditional dynamics and less than $\sqrt{2}$ for conditional dynamics. We assess the implications for using this analog measurement–driven approach to quantum computing in practice.

quantum information↗

On Undecidability Aspects of Resilient Computations and Implications to Exascale

Future Exascale computing systems with a large number of processors, memory elements and interconnection links, are expected to experience multiple, complex faults, which affect both applications and operating-runtime systems. A variety of algorithms, frameworks and tools are being proposed to realize and/or verify the resilience properties of computations that guarantee correct results on failure-prone computing systems. We analytically show that certain resilient computation problems in presence of general classes of faults are undecidable, that is, no algorithms exist for solving them. We first show that the membership verification in a generic set of resilient computations is undecidable. We describe classes of faults that can create infinite loops or non-halting computations, whose detection in general is undecidable. We then show certain resilient computation problems to be undecidable by using reductions from the loop detection and halting problems under two formulations, namely, an abstract programming language and Turing machines, respectively. These two reductions highlight different failure effects: the former represents program and data corruption, and the latter illustrates incorrect program execution. These results call for broad-based, well-characterized resilience approaches that complement purely computational solutions using methods such as hardware monitors, co-designs, and system- and application-specific diagnosis codes.

Exascale systems↗

Presentation layer of CMS Online Monitoring System

The Compact Muon Solenoid (CMS) is one of the experiments at the CERN Large Hadron Collider (LHC). The CMS Online Monitoring system (OMS) is an upgrade and successor to the CMS Web-Based Monitoring (WBM)system, which is an essential tool for shift crew members, detector subsystem experts, operations coordinators, and those performing physics analyses. The CMS OMS is divided into aggregation and presentation layers. Communication between layers uses RESTful JSON:API compliant requests. The aggregation layer is responsible for collecting data from heterogeneous sources, storage of transformed and pre-calculated (aggregated) values and exposure of data via the RESTful API. The presentation layer displays detector information via a modern, user-friendly and customizable web interface. The CMS OMS user interface is composed of a set of cutting-edge software frameworks and tools to display non-event data to any authenticated CMS user worldwide. The web interface tree-like component structure comprises (top-down): workspaces, folders, pages, controllers and portlets. A clear hierarchy gives the required flexibility and control for content organization. Each bottom element instantiates a portlet and is a reusable component that displays a single aspect of data, like a table, a plot, an article, etc. Pages consist of multiple different portlets and can be customized at runtime by using a drag-and-drop technique. This is how a single page can easily include information from multiple online sources. Different pages give access to a summary of the current status of the experiment, as well as convenient access to historical data. This paper describes the CMS OMS architecture, core concepts and technologies of the presentation layer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DIMPLES: Distributed Influence Maximization for Pandemic pLanning on Exascale Systems

We study exascale parallel algorithms for the selection of intervention or monitoring strategies in massive realistic socio-technical networks through scalable Influence Maximization (InfMax) algorithms. We employ novel techniques to enable efficient scaling on up to 8k nodes of OLCF Frontier, with 65k AMD GPUs and 458k AMD CPU cores. Current state-of-the-art InfMax tools are limited to networks with only a few million actors (vertices) and a few hundred million interactions (edges). By overcoming these limitations, we show that our approach is capable of processing a realistic social contact network of the United States with 285 million nodes and about 8 billion edges. This two orders-of-magnitude improvement over the previous state-of-the-art is obtained by leveraging algorithmic advancements for the InfMax problem and designing several problem-specific approaches to overlap communication with computation, improve GPU efficiency, and lower the application’s memory requirements. We evaluate strong scaling for computing 10k most influential seeds using up to 8k nodes of an exascale system, and weak scaling from 128 to 8k system nodes for seed sets ranging from 625 to 40k seeds. We achieve the fastest-known runtime of 25 minutes while performing 48 million diffusion simulations totaling 2.31 petabytes to identify 40k influential seeds using 8k nodes, and take 5.75 minutes to identify 10k seeds while using 4k nodes.

Minutoli, Marco [Pacific Northwest National Labora↗

Monitoring of Temperature Measurements for Different Flow Regimes in Water and Galinstan with Long Short-Term Memory Networks and Transfer Learning of Sensors

Temperature sensing is one of the most common measurements of a nuclear reactor monitoring system. The coolant fluid flow in a reactor core depends on the reactor power state. We investigated the monitoring and estimation of the thermocouple time series using machine learning for a range of flow regimes. Measurement data were obtained, in two separate experiments, in a flow loop filled with water and with liquid metal Galinstan. We developed long short-term memory (LSTM) recurrent neural networks (RNNs) for sensor predictions by training on the sensor’s own prior history, and transfer learning LSTM (TL-LSTM) by training on a correlated sensor’s prior history. Sensor cross-correlations were identified by calculating the Pearson correlation coefficient of the time series. The accuracy of LSTM and TL-LSTM predictions of temperature was studied as a function of Reynolds number (Re). The root-mean-square error (RMSE) for the test segment of time series of each sensor was shown to linearly increase with Re for both water and Galinstan fluids. Using linear correlations, we estimated the range of values of Re for which RMSE is smaller than the thermocouple measurement uncertainty. For both water and Galinstan fluids, we showed that both LSTM and TL-LSTM provide reliable estimations of temperature for typical flow regimes in a nuclear reactor. The LSTM runtime was shown to be substantially smaller than the data acquisition rate, which allows for performing estimation and validation of sensor measurements in real time.

Pantopoulou, Stella↗

Comfort in High-Performance Homes in a Hot-Humid Climate

TO5 2.3.2: Large-Scale Temperature Study Although space-conditioning systems are required to meet standards such as those in the Air Conditioning Contractors of America (ACCA) Manual RS (Rutkowski 1997) and the ASHRAE Standard 55 (ASHRAE 2013) comfort criteria, little is known about how space-conditioning systems are actually operating in the field and if these systems are meeting those standards. Unconventional space-conditioning systems may be necessary for low-load homes in the future. It is important to know how current systems are functioning in existing homes and to what temperatures occupants typically set the thermostats in their homes. The U.S. Department of Energy's Building America research team IBACOS set out to find some answers. By using low-cost data loggers and occupant surveys to monitor 37 single-family homes that have standard heating, ventilating, and air-conditioning (HVAC) equipment, the team gained insight into how sensitive occupants are to comfort in their homes relative to the ACCA and ASHRAE standards. This study focused on one climate zone (hot-humid); however, future studies may find differences among occupants- ideas of thermal comfort in other climate zones. Data were collected from installed sensors during a 2-month period from late August 2014 through late October 2014. The final aspect of this project was to review the business metrics associated with builders involved in a comfort and performance guarantee program. The results of this study-taken as an aggregate-show that the homes provided room-to-room temperature differences less than 6 degrees F 95% of the time. Temperature differences were less than 4 degrees F 80% of the time. Some homes showed better or worse performance. On average, two-story homes had a 3.3 degrees F temperature difference between rooms; single-story homes had an average of a 2.2 degrees F temperature difference between rooms. Occupants who did not use programmable thermostats had an average set point of 75 degrees F. Homes in which the thermostats were programmed with a setback schedule showed a median baseline temperature value of 74 degrees F and had a median afternoon setback of 75 degrees F. System runtime was analyzed and showed that the room-to-room temperature uniformity in some homes worsened during an on cycle, whereas the uniformity improved in other homes. That is, when the system was running, some rooms were receiving too much or too little air relative to the rest of the house, and the temperatures in those rooms were moving away from the temperatures of the other rooms in the house. Finally, analysis of the thermostat data shows a wide degree of variability among homes in the study. Interpretation of the measured data suggests that 21 occupants made no regular adjustments to the thermostats in their homes, seven had regular setbacks, seven showed varying setbacks, and 10 appeared to follow no pattern (with random adjustments). Ultimately, the data show that current systems are maintaining expected levels of comfort. As expected, it is more challenging to maintain a uniform temperature in all rooms of two-story homes, and future systems should address this issue. Furthermore, the data show that the majority of homes maintained relative humidity levels below 60% without any supplemental dehumidification

ACCA Manual RS↗

Flexible and Effective Object Tiering for Heterogeneous Memory Systems

Computing platforms that package multiple types of memory, each with their own performance characteristics, are quickly becoming mainstream. To operate efficiently, heterogeneous memory architectures require new data management solutions that are able to match the needs of each application with an appropriate type of memory. As the primary generators of memory usage, applications create a great deal of information that can be useful for guiding memory management, but the community still lacks tools to collect, organize, and leverage this information effectively. To address this gap, this work introduces a novel software framework that collects and analyzes object-level information to guide memory tiering. The framework includes tools to monitor the capacity and usage of individual data objects, routines that aggregate and convert this information into tier recommendations for the host platform, and mechanisms to enforce these recommendations according to user-selected policies. Moreover, the developed tools and techniques are fully automatic, work on standard Linux systems, and do not require modification or recompilation of existing software. Using this framework, this study evaluates and compares the impact of a variety of design choices for memory tiering, including different policies for prioritizing objects for the fast memory tier as well as the frequency and timing of migration events. In conclusion, the results, collected on a modern Intel platform with conventional DDR4 SDRAM as well as Intel Optane NVRAM, show that guiding data tiering with object-level information can enable significant performance and efficiency benefits compared with standard hardware- and software-directed data-tiering strategies for a diverse set of memory-intensive workloads.

97 MATHEMATICS AND COMPUTING↗