Influence of testing environment on the room temperature ductility of FeAl alloys

The effects of testing atmospheres (air, O2, N2, and vacuum) on the room-temperature ductility of Fe-40Al, Fe-40Al-0.5B, and Fe-50Al alloys were investigated. The results confirmed the decrease in room-temperature ductility of Fe-rich FeAl alloys by the interaction of the aluminide with water vapor, reported previously by Liu et al. (1989). The highest ductilities were measured in the atmosphere with the lowest moisture levels, i.e., in vacuum. It was found that significant ductility is still restricted to Fe-rich alloys (Fe-40Al), as the Fe-50Al alloy remained brittle under all testing conditions. It was also found that slow cooling after annealing was beneficial, and the effect was additive to the environmental effect. The highest ductility measurements in this study were 9 percent elongation in furnace-cooled Fe-40Al and in Fe-40Al-0.5B, when tested in vacuum.

Gaydosh, D. J.↗

Room-temperature InGaAs detector arrays for 1.0 - 1.7 microns spectroscopy

Linear arrays of 256 element InGaAs detectors with 100 x 30 micron pixels were mounted in multiplexer packages and tested in an optical multichannel analyzer (OMA). Typical performance characteristics include dark current (-5V) of 400 picoamps and responsivities of 0.75 A/W (1.3 microns) and 0.14 A/W (0.85 microns). The 256 element exhibited a mean room-temperature dark current of under 400 picoamps when mounted in the OMA and a dynamic range over 11 bits (2000:1). Future applications, including room-temperature detector arrays for 2.5 microns and avalanche photodiode arrays for 1.0-1.7 microns, are discussed.

Olsen, G. H.↗

Room Temperature Cyclic Deformation Behavior of Cast and Extruded NiAl

The fully reversed, strain controlled fatigue behavior of cast and extruded NiAl was evaluated at room temperature for plastic strain ranges of 0.0006 to 0.0002 to provide baseline data on the fatigue life of NiAl and to investigate whether the low ductility of NiAl would result in poor low-cycle fatigue behavior. Except at the smallest plastic strain range investigated, NiAl work hardened continuously until failure with a final fracture stress under cyclic conditions which was at least 60 percent greater than the monotonic fracture strength of NiAl. Fatigue fracture initiation occurred at large internal tear-shaped pores, and fatigue life was controlled or limited by the presence of these processing-related defects. Even with the processing defects present in this material and the limited ductility of NiAl in general, cast and extruded NiAl exhibited much greater fatigue life at room temperature than comparable B2 ordered compounds when compared on a strain range basis.

Noebe, R. D.↗

Magnetically suspended stepping motors for clean room and vacuum environments

To answer the growing needs for super-clean or contact free actuators for uses in clean rooms, vacuum chambers, and space, innovative actuators which combine the functions of stepping motors and magnetic bearings in one body were developed. The rotor of the magnetically suspended stepping motor is suspended like a magnetic bearing and rotated and positioned like a stepping motor. The important trait of the motor is that it is not a simple mixture or combination of a stepping motor and conventional magnetic bearing, but an amalgam of a stepping motor and a magnetic bearing. Owing to optimal design and feed-back control, a toothed stator and rotor are all that are needed structurewise for stable suspension. More than ten types of motors such as linear type, high accuracy rotary type, two-dimensional type, and high vacuum type were built and tested. This paper describes the structure and design of these motors and their performance for such applications as precise positioning rotary table, linear conveyor system, and theta-zeta positioner for clean room and high vacuum use.

Higuchi, Toshiro↗

Binaural room simulation

In every-day listening the auditory event perceived by a listener is determined not only by the sound signal that a sound emits but also by a variety of environmental parameters. These parameters are the position, orientation and directional characteristics of the sound source, the listener's position and orientation, the geometrical and acoustical properties of surfaces which affect the sound field and the sound propagation properties of the surrounding fluid. A complete set of these parameters can be called an Acoustic Environment. If the auditory event perceived by a listener is manipulated in such a way that the listener is shifted acoustically into a different acoustic environment without moving himself physically, a Virtual Acoustic Environment has been created. Here, we deal with a special technique to set up nearly arbitrary Virtual Acoustic Environments, the Binaural Room Simulation. The purpose of the Binaural Room Simulation is to compute the binaural impulse response related to a virtual acoustic environment taking into account all parameters mentioned above. One possible way to describe a Virtual Acoustic Environment is the concept of the virtual sound sources. Each of the virtual sources emits a certain signal which is correlated but not necessarily identical with the signal emitted by the direct sound source. If source and receiver are non moving, the acoustic environment becomes a linear time-invariant system. Then, the Binaural Impulse Response from the source to a listener' s eardrums contains all relevant auditory information related to the Virtual Acoustic Environment. Listening into the simulated environment can easily be achieved by convolving the Binaural Impulse Response with dry signals and representing the results via headphones.

Lehnert, H.↗

KATE: From the lab to the firing room

For the past 9 years, the AI group at NASA's Kennedy Space Center (KSC) has been developing a real-time model-based reasoning (MBR) system that can diagnose faults and provide control advisories. The system resulting from this effort is called KATE (Knowledge-based Autonomous Test Engineer). This article describes the transition of KATE from the applied research lab to the firing room (the firing room is the main control and monitoring center for all Shuttle ground support and launch processing). Because the problems that were countered along the way are not unique, we decided to share some of our experiences. This article also includes a brief overview of the latest application of KATE.

Pepe, Charles↗

Lightning Effects in the Payload Changeout Room

Analytical and empirical studies have been performed to provide better understanding of the electromagnetic environment inside the Payload Changeout Room and Orbiter payload bay resulting from lightning strikes to the launch pad lightning protection system. The analytical studies consisted of physical and mathematical modeling of the pad structure and the Payload Changeout Room. Empirical testing was performed using a lightning simulator to simulate controlled (8 kA) lightning strikes to the catenary wire lightning protection system. In addition to the analyses and testing listed above, an analysis of the configuration with the vehicle present was conducted, in lieu of testing, by the Finite Difference, Time Domain method.

Thomas, Garland L.↗

Ultra-Low-Cost Room Temperature SiC Thin Films

The research group at CSU has conducted theoretical and experimental research on 'Ultra-Low-Cost Room Temperature SiC Thin Films. The effectiveness of a ultra-low-cost room temperature thin film SiC growth technique on Silicon and Germanium substrates and structures with applications to space solar sells, ThermoPhotoVoltaic (TPV) cells and microelectronic and optoelectronic devices was investigated and the main result of this effort are summarized.

Faur, Maria↗

Epitaxial Ferroelectric Ba(0.5)Sr(0.5)TiO3 Thin Films for Room-Temperature High-Frequency Tunable Element Applications

Perovskite Ba(0.5)SR(0.5)TiO3 thin films have been synthesized on (001) LaAl03 substrates by pulsed laser ablation. Extensive X-ray diffraction, rocking curve, and pole-figure studies suggest that the films are c-axis oriented and exhibit good in-plane relationship of <100>(sub BSTO)//<100>(sub LAO). Rutherford Backscattering Spectrometry studies indicate that the epitaxial films have excellent crystalline quality with an ion beam minimum yield chi(sub min) Of only 2.6 %. The dielectric property measurements by the interdigital technique at 1 MHz show room temperature values of the relative dielectric constant, epsilon(sub r), and loss tangent, tan(sub delta), of 1430 and 0.007 with no bias, and 960 and 0.001 with 35 V bias, respectively. The obtained data suggest that the as-grown Ba(0.5)SR(0.5)TiO3 films can be used for development of room-temperature high-frequency tunable elements.

Chen, C. L.↗

Oxygen Impurities and Defects in Epitaxial Layer SiC and SiC Wafer Characterized by Room and Low Temperatures FTIR

SiC as a highly promising semiconducting material has received increasing attention in the last decade. The impurities such as oxygen and hydrogen have a great effect in electronic properties of semiconducting materials. In this study, the FTIR spectra were measured at room temperature (25 C) and low temperature (-70 C) for an n-type SiC substrate, a p-type epitaxial layer SiC, and patterned Ta on a p-type epitaxial layer SiC sample. The oxygen related IR peaks were measured for all three samples at room and low temperatures. The peak at 1105 cm(exp -1) is the result of a substitutional carbon and a interstitial oxygen in SiC. The concentration of the impurity oxygen increases in the SiC epitaxial layer during the CVD and electron beam processes. For the n-type SiC substrate, this peak does not appear. The peak at 905 cm(exp -1) exists in the IR spectra only for two epitaxial layer on p-type SiC substrate samples. This peak is related to oxygen vacancy centers in SiC, which are introduced in the CVD epitaxial growth process. At low temperature, the peak at 1105 cm(exp -1) shifts down and the peak at 905 cm(exp -1) shifts up for the epitaxial layer SiC samples. It can be explained that, at low temperatures, the stress increases due to the distorted bonds. The study shows that FTIR is a very effective method to evaluate low concentration impurities in SiC.

Lu, W. J.↗

Room and Elevated Temperature Tensile Properties of Single Tow Hi-Nicalon, Carbon Interphase, CVI SiC Matrix Minicomposites

Single tow Hi-Nicalon(TM), C interphase, CVI SiC matrix minicomposites were tested in tension at room temperature, 700 C, 950 C, and 1200 C in air. Monotonic loading with modal acoustic emission monitoring was performed at room temperature in order to determine the dependence of matrix cracking on applied load. Modal acoustic emission was shown to correlate directly with the number of matrix cracks formed. Elevated temperature constant load stress-rupture and low-cycle fatigue experiments were performed on precracked specimens. The elevated temperature rupture behavior was dependent on the precrack stress, the lower precrack stress resulting in longer rupture life for a given stress. It was found that the rupture lives of C-interphase Hi-Nicalon(TM) minicomposites were superior to C-interphase Ceramic Grade Nicalon(TM) minicomposites and inferior to those of BN-interphase Hi-Nicalon(TM) minicomposites.

Martinez-Fernandez, J.↗

Room Temperature Creep Of SiC/SiC Composites

During a recent experimental study, time dependent deformation was observed for a damaged Hi-Nicalon reinforced, BN interphase, chemically vapor infiltrated SiC matrix composites subjected to static loading at room temperature. The static load curves resembled primary creep curves. In addition, acoustic emission was monitored during the test and significant AE activity was recorded while maintaining a constant load, which suggested matrix cracking or interfacial sliding. For similar composites with carbon interphases, little or no time dependent deformation was observed. Evidently, exposure of the BN interphase to the ambient environment resulted in a reduction in the interfacial mechanical properties, i.e. interfacial shear strength and/or debond energy. These results were in qualitative agreement with observations made by Eldridge of a reduction in interfacial shear stress with time at room temperature as measured by fiber push-in experiments.

Morscher, Gregory N.↗

A Comparison of Weld-Repaired and Base Metal for Inconel 718 and CRES 321 at Cryogenic and Room Temperatures

Fatigue crack growth tests were conducted to characterize the performance of Inconel 718 and CRES 321 welds, weld heat-affect-zone and parent metal at room temperature laboratory air and liquid nitrogen (-196oC) environments. The results of this study were required to predict the damage tolerance behavior of proposed orbiter main engine hydrogen fuel liner weld repairs. Experimental results show that the room and cryogenic temperature fatigue crack growth characteristics of both alloys are not significantly degraded by the weld repair process. However, both Inconel 718 and CRES 321 exhibited lower apparent toughness within the weld repair region compared to the parent metal.

Newman, John A.↗

Resetting of circadian melatonin and cortisol rhythms in humans by ordinary room light

The present study was designed to investigate whether a weak photic stimulus can reset the endogenous circadian rhythms of plasma melatonin and plasma cortisol in human subjects. A stimulus consisting of three cycles of 5 h exposures to ordinary room light (approximately 180 lux), centered 1.5 h after the endogenous temperature nadir, significantly phase-advanced the plasma melatonin rhythm in eight healthy young men compared with the phase delays observed in eight control subjects who underwent the same protocol but were exposed to darkness (p < or = 0.003). After light-induced phase advances, the circadian rhythms of plasma melatonin and plasma cortisol maintained stable temporal relationships with the endogenous core body temperature cycle, consistent with the conclusion that exposure to ordinary indoor room light had shifted a master circadian pacemaker.

Non-NASA Center↗

Modeling the Effect of Enlarging Seating Room on Passengers' Preference of Taiwan's Domestic Airlines

This study addresses the need for measuring the effect of enlarging seating room in airplane on passengers' preferences of airline in Taiwan. The results can assist Taiwan's domestic air carriers in better understanding their customers' expectations. Stated choice experiment is used to incorporate passengers' trade-offs in the preferred measurement, and three major attributes are taken into account in the stated choice experiment: (1) type of seat (enlarged or not), (2) price, and (3) brand names of airlines. Furthermore, a binary logit model is used to model the choice behavior of air passengers. The findings show that the type of seat is a major significant variable; price and airline's brand are also significant as well. It concludes that air carriers should put more emphasis on the issue of improving the quality of seat comfort. Keywords: Passengers' preference, Enlarged seating room, Stated choice experiment, Binary logit model.

Lu, Jin-Long↗

Testing Efficiency Improved by Addition of Remote Access Control Room

The NASA Lewis Research Center's Remote Access Control Room (RACR) uses off-the-shelf video conferencing software integrated with existing facility data systems to provide access to the test data by networking from virtually anywhere in the country. The system allows research engineers in remote locations to participate in tests and monitor data in real time just as if they were present in the control room.

Source record↗

Single Event Effects on Space Radiation Hardened 64K SRAMS at Room temperature

The laser threshold linear Energy transfer for single event upsetscan be estimaed, even at room temperature, for space radiation hardened 64K SRAMs. The memories where independently developed to quality for the Qualified Manufacturer's List by IBM and Honeywell. The memory was so hard that high energy heavy ions generated by the Van de Graff could not determine the SEU threshold at room temperature. Use of pulsed Laser tests would meake it possible to forgo very expensive testing at ultra-high energy accelerators.

Space Radiation 64K SRAMS↗

Room-Temperature-Cured Copolymers for Lithium Battery Gel Electrolytes

Polyimide-PEO copolymers (PEO signifies polyethylene oxide) that have branched rod-coil molecular structures and that can be cured into film form at room temperature have been invented for use as gel electrolytes for lithium-ion electric-power cells. These copolymers offer an alternative to previously patented branched rod-coil polyimides that have been considered for use as polymer electrolytes and that must be cured at a temperature of 200 C. In order to obtain sufficient conductivity for lithium ions in practical applications at and below room temperature, it is necessary to imbibe such a polymer with a suitable carbonate solvent or ionic liquid, but the high-temperature cure makes it impossible to incorporate and retain such a liquid within the polymer molecular framework. By eliminating the high-temperature cure, the present invention makes it possible to incorporate the required liquid.

Meador, Mary Ann B.↗