Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “roof”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The application of photovoltaic roof shingles to residential and commercial buildings

The recent development of a shingle-type solar-cell module makes it possible to incorporate easily photovoltaic power generation into the sloping roofs of residential or commercial buildings. These modules, which use a closely packed array of nineteen 53-mm-diameter circular solar cells, are capable of producing 101 watts/sq m of module area under standard operating conditions. This module performance is achievable by the use of solar cells with an average efficiency of 13.3 percent at 1 kW/sq m air-mass-1.5 insolation and at a cell temperature of 28 C. When these modules are mounted on a sloping south-facing roof which is insulated on the rear surface, the annual energy generated at the maximum power operating point will vary from 255.6 to 137.3 kWh/sq m of module area depending on the site location, with Albuquerque, NM, and Seattle, WA, representing the highest and lowest values of the thirteen sites considered.

Shepard, N. F., Jr.↗

Photovoltaic Roofs

Solar cells perform two functions: waterproofing roof and generating electricity. Sections through horizontal and slanting joints show overlapping modules sealed by L-section rubber strips and side-by-side modules sealed by P-section strips. Water seeping through seals of slanting joints drains along channels. Rooftop photovoltaic array used watertight south facing roof, replacing shingles, tar, and gravel. Concept reduces cost of residential solar-cell array.

Drummond, R. W., Jr.↗

A Roof for the Lion's House

Fans of the National Football League's Detroit Lions don't worry about gameday weather. Their magnificent new Pontiac Stadium has a domed, air-supported, fabric roof that admits light but protects the playing field and patrons from the elements. The 80,000-seat "Silverdome" is the world's largest fabric-covered structure-and aerospace technology played an important part in its construction. The key to economical construction of the Silverdome-and many other types of buildings-is a spinoff of fiber glass Beta yarn coated with Teflon TFE fluorocarbon resin. The big advance it offers is permanency. Fabric structures-tents, for example have been around since the earliest years of human civilization. But their coverings-hides, canvas and more recently plastics-were considered temporary; though tough, these fabrics were subject to weather deterioration. Teflon TFE-coated Beta Fiberglas is virtually impervious to the effects of weather and sunlight and it won't stretch, shrink, mildew or rot, thus has exceptional longevity; it is also very strong, lightweight, flame resistant and requires no periodic cleaning, because dirt will not stick to the surface of Teflon TFE. And to top all that, it costs only 30 to 40 percent as much as conventional roofing.

Source record↗

Self-supporting roof panel

A self-supporting panel is used to form building components, including roofs that have no independent supports for the panels between the ends of the panels. The panel system includes a base support or structural component having a top face sheet supported by longitudinally load carrying webs and a layer of insulation on the exterior of the face sheet. The insulation spans the entire face sheet to overlie connectors between the edges of adjacent panels when the panels are assembled to form a wall or roof, to eliminate thermal shorts.

Davidson, Jane↗

De-pollution efficacy of photocatalytic roofing granules

Photocatalytic building surfaces can harness sunlight to reduce urban air pollution. The NO x abatement capacity of TiO 2 -coated granules used in roofing products was evaluated for commercial product development. A laboratory test chamber and ancillary setup were built following conditions prescribed by ISO Standard 22197-1. It was validated by exposing reference P25-coated aluminum plates to a 3 L min -1 air flow enriched in 1 ppm NO under UVA irradiation (360 nm, 11.5 W m -2 ). We characterized prototype granule-surfaced asphalt shingles and loose granules prepared with different TiO 2 loadings and post-treatment formulations. Tests performed at surface temperatures of 25 and 60 °C showed that NO x abatement was more effective at the higher temperature. Preliminary tests explored the use of 1 ppm NO 2 and of 1 ppm and 0.3 ppm NO/NO 2 mixtures. Specimens were aged in a laboratory accelerated weathering apparatus, and by exposure to the outdoor environment over periods that included dry and rainy seasons. Laboratory aging led to higher NO removal and NO 2 formation rates, and the same catalyst activation was observed after field exposure with frequent precipitation. However, exposure during the dry season reduced the performance. This inactivation was mitigated by cleaning the surface of field-exposed specimens. Doubling the TiO 2 loading led to a 50–150% increase in NO removal and NO x deposition rates. Finally, application of different post-treatment coatings decreased NO removal rates (21–35%) and NO x deposition rates (26–74%) with respect to untreated granules. The mass balance of nitrogenated species was assessed by extracting granules after UV exposure in a 1 ppm NO-enriched atmosphere.

54 ENVIRONMENTAL SCIENCES↗

Simulation of effects of direction and air flow speed on temperature distribution in the room covered by various roof materials

The objective of this research is to get a comparison of the distribution of the room temperature by using three materials, namely plastic-rubber composite, clay, and asbestos. The simulation used Ansys Fluent to get the temperature distribution. There were two conditions in this simulations, first the air passing beside the room and second the air passing in front of the room. Each condition will be varied with the air speed of 1 m/s, 2 m/s, 3 m/s, 4 m/s, 5 m/s for each material used. There are three heat transfers in this simulation, namely radiation, convection, and conduction. Based on the ANSI/ ASHRAE Standard 55-2004, the results of the simulation showed that the best temperature distribution was the roof of plastic-rubber composites.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Convergent Spray Technology(TM) Spray Process for Roof Coating Application

The overall goal of this project was to demonstrate the feasibility of(CST) Convergent Spray Technology (Trademark) for the roofing industry. This was accomplished by producing an environmentally compliant coating utilization recycled materials, a CST(Trademark) spray process portable application cart, and hand-held applicator with a CST(Trademark) spray process nozzle. The project culminated with application of this coating to a nine hundred sixty square foot metal for NASA Marshall Space Flight Center (MSFC) in Huntsville, Alabama.

COATINGS↗

Solar Economies of Scope through the Intersection of Four Industries: PV Installation, Electrical, Construction, and Roofing

The U.S. solar photovoltaic (PV) installation industry largely grew from pre-existing industries that provide related services such as electrical contracting, construction, and roofing. In this report, we use a new data set based on data from the California Contractors State License Board (CSLB) to explore the ties between PV installation and these related-service industries. Based on a study period of 2010 to 2016, the CSLB data show that most PV installers hold some license other than the license designed specifically for PV installation, primarily electrical and construction licenses. Indeed, only about 9% of PV installers hold only the solar contractor license. The fact that most PV installers hold electrician and construction licenses illustrates the important ties between PV installation and these industries. The CSLB data, combined with residential PV price data, also show that installers with multiple non-solar licenses are associated with lower-priced systems. These findings suggest that installers with multiple skillsets may be able to reduce PV installation costs. Further, the data show that PV systems are lower-priced when installed during new construction, especially when new-construction systems are installed by licensed roofers.

14 SOLAR ENERGY↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Interdependent Dynamics of LAI-Albedo across the Roofing Landscapes: Mongolian and Tibetan Plateaus

The Mongolian Plateau (MP) and Tibetan Plateau (TP) have experienced higher-than-global average warming in recent decades, resulting in many significant changes in ecosystem structure and function. Among them are the leaf area index (LAI) and albedo, which play a fundamental role in understanding many causes and consequences of land surface processes and climate. Here, we focused on the spatiotemporal changes of LAI, albedo, and their spatiotemporal relationships on the two roofing landscapes in Eurasia. Based on the MODIS products, we investigated the spatiotemporal changes of albedo( VIS, NIR and SHO ) and LAI from 2000 through 2016. We found that there existed a general negative logarithmic relationship between LAI and three measures of albedo on both plateaus. No significant relationship was found for LAI-albedo NIR on the TP, due to more complex land surface canopy characteristics affected by the NIR reflection there. During 2000–2016, overall, annual mean LAI increased significantly by 119.40 × 10 3 km 2 on the MP and by 28.35 × 10 3 km 2 on the TP, while the decreased areas for annual mean albedoVIS were 585.59 × 10 3 km 2 and 235.73 × 10 3 km 2 on the MP and TP, respectively. More importantly, the LAI-albedo relationships varied substantially across the space and over time, with mismatches found in some parts of the landscapes. Substantial additional efforts with observational and/or experimental investigations are needed to explore the underlying mechanisms responsible for these relationships, including the influences of vegetation characteristics and disturbances.

54 ENVIRONMENTAL SCIENCES↗

Solar power roof shingle

Silicon solar cell module provides both all-weather protection and electrical power. Module consists of array of circular silicon solar cells bonded to fiberglass substrate roof shingle with fluorinated ethylene propylene encapsulant.

Forestieri, A. F.↗

A steering law for a roof-type configuration for a single-gimbal control moment gyro system

Single-Gimbal Control Moment Gyro (SGCMG) systems have been investigated for attitude control of the Large Space Telescope (LST) and the High Energy Astronomy Observatory (HEAO). However, various proposed steering laws for the SGCMG systems thus far have some defects because of singular states of the system. In this report, a steering law for a roof-type SGCMG system is proposed which is based on a new momentum distribution scheme that makes all the singular states unstable. This momentum distribution scheme is formulated by a treatment of the system as a sampled-data system. From analytical considerations, it is shown that this steering law gives control performance which is satisfactory for practical applications. Results of the preliminary computer simulation entirely support this premise.

Yoshikawa, T.↗

The detection of the coal roof interface by use of high pressure water

A device whereby water jets can be used to detect the interface between coal and the overlying roof rock is described. Once this identification is made this distance can be measured using instruments such as the autofocus systems recently developed in the photographic industry. Experiments carried out show that the device can discriminate between coal and rock at coal thicknesses up to 8 inches. An autofocus system was examined which indicates accuracies of better than 0.1 inches.

Source record↗