SEARCH · Engineering Papers
Results for “risers”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Method and Prediction of Transition Velocities in a Circulating Fluidized Bed's Riser
Explore the source record for details and available documents.
Analysis of Solids Volume Fraction and Dimensionless Regime Mapping in a Circulating Fluidized Bed Riser
2024 AIChE Annual Meeting conference presentation detailing the analysis of legacy solids concentration measure data taken via optical fiber probe in NETL's 12-inch Cold Flow Circulating Fluidized Bed (CFCFB), including discussion of the variation in statistical and chaotic parameters as a function of different fluidization regimes.
Dimensionless Regime Mapping and Chaos Analysis of Solids Volume Fraction Data in a Circulating Fluidized Bed Riser
Presentation of experimental results of solids volume fraction data measurements in a 12-inch diameter cold flow circulating fluidized bed in relation to a dimensionless fluidization regime map. Statistical and chaotic system analysis results are shown to illustrate differences in hydrodynamic behavior at different operating conditions. Presentation was made at the ASTFE 10th Thermal and Fluids Engineering Conference, March 09-12, 2025.
CONSTRUCTION METHOD STUDY FOR INSTALLATION OF A LARGE RISER IN A SINGLE SHELL TANK
This study evaluates and identifies a construction method for cutting a hole in a single-shell tank dome. This study also identifies and evaluates vendors for performing the cut.
CONSTRUCTION METHOD STUDY FOR INSTALLATION OF A LARGE RISER IN A SINGLE-SHELL TANK
This study evaluates and identifies a construction method for cutting a hole in a single-shell tank dome. This study also identifies and evaluates vendors for performing the cut.
Observation of flow regime transition in a CFB riser using an LDV
Explore the source record for details and available documents.
CFPD Analysis of a Vortexing Bed Riser System
Presented by NETL at NETL Multiphase Flow Workshop, 08/16
Riser Dynamics – a Comparison of Scale
Presented by NETL at 8th World Congress on Particle Technology, 04/18
Effects of Scale on CFB Riser Dynamics
Presented by NETL at Clearwater Clean Energy Conference 06/19
Dynamical tests on fiber optic data taken from the riser section of a circulating fluidized bed
Dynamical tests have been applied to fiber optic data taken from a cold-flow circulating fluidized bed to characterize flow conditions, identify three time and/or length scales (macro, meso, and micro), and understand the contribution these scales have on the raw data. The characteristic variable analyzed is the raw voltage signal obtained from a fiber-optic probe taken at various axial and radial positions under different loading conditions so that different flow regimes could be attained. These experiments were carried out with the bed material of 812 μm cork particles. The characterization was accomplished through analysis of the distribution of the signal through the third and fourth moments of skewness and excess kurtosis. A generalization of the autocorrelation function known as the average mutual information function was analyzed by examining the function’s first minimum, identifying the point at which successive elements are no longer correlated. Further characterization was accomplished through the correlation dimension, a measure of the complexity of the attractor. Lastly, the amount of disorder of the system is described by a Kolmogorov-type entropy estimate. All six aforementioned tests were also implemented on ten levels of detail coefficients resulting from a discrete wavelet transformation of the same signal as used above. Through this analysis it is possible to identify and describe micro (particle level), meso (clustering or turbulence level), and macro (physical or dimensional level) length scales even though some literature considers these scales inseparable [6]. This investigation also used detail wavelet coefficients in conjunction with ANOVA analysis to show which scales have the most impact on the raw signal resulting from local hydrodynamic conditions.
System for estimating fatigue damage
In one aspect, a system for estimating fatigue damage in a riser string is provided. The system includes a plurality of accelerometers which can be deployed along a riser string and a communications link to transmit accelerometer data from the plurality of accelerometers to one or more data processors in real time. With data from a limited number of accelerometers located at sensor locations, the system estimates an optimized current profile along the entire length of the riser including riser locations where no accelerometer is present. The optimized current profile is then used to estimate damage rates to individual riser components and to update a total accumulated damage to individual riser components. The number of sensor locations is small relative to the length of a deepwater riser string, and a riser string several miles long can be reliably monitored along its entire length by fewer than twenty sensor locations.
Computational Modeling of Circulating Fluidized Bed Reactors
Details of numerical simulations of two-phase gas-solid turbulent flow in the riser section of Circulating Fluidized Bed Reactor (CFBR) using Computational Fluid Dynamics (CFD) technique are reported. Two CFBR riser configurations are considered and modeled. Each of these two riser models consist of inlet, exit, connecting elbows and a main pipe. Both riser configurations are cylindrical and have the same diameter but differ in their inlet lengths and main pipe height to enable investigation of riser geometrical scaling effects. In addition, two types of solid particles are exploited in the solid phase of the two-phase gas-solid riser flow simulations to study the influence of solid loading ratio on flow patterns. The gaseous phase in the two-phase flow is represented by standard atmospheric air. The CFD-based FLUENT software is employed to obtain steady state and transient solutions for flow modulations in the riser. The physical dimensions, types and numbers of computation meshes, and solution methodology utilized in the present work are stated. Flow parameters, such as static and dynamic pressure, species velocity, and volume fractions are monitored and analyzed. The differences in the computational results between the two models, under steady and transient conditions, are compared, contrasted, and discussed.
SRS Strategy for Tank 3 Salt Dissolution - Performance and Lessons Learned - 20441
The Savannah River Site (SRS) Tank Farms have 51 underground waste tanks used to store and process liquid nuclear waste materials. There are 4 different tank types, ranging in capacity from 2,840,000 to 4,920,000 L (750,000 to 1,300,000 Gal). Twenty-four of the tanks are older style and do not meet full secondary containment standards. The older style tanks are the initial focus of waste removal efforts for tank closure at SRS. Eight of these twenty-four tanks have completed waste removal and are filled with grout. Prior to salt dissolution, Tank 3 was a dry salt tank that contained 5.06 m (199.3 in) of salt and sludge waste. Additional salt waste was present on cooling coils above the salt layer up to approximately 5.59 m (220 in). Three mixing eductors were installed in Tank 3 to aid in dissolving salt waste in three tank riser access ports. A transfer pump was installed, and the transfer pump suction was located 25.4 cm (10 in) from the tank bottom. Well water was added to the tank through a downcomer until the dry bulk salt was covered with liquid. During the initial fill of Tank 3, approximately 242,000 L (64,000 Gal) of rain water were added from periodic F-Tank Farm (FTF) Catch Tank additions and approximately 17,000 L (4,500 Gal) of well water were added. Following liquid additions to cover the dry bulk salt, well water was added through the three mixing eductors in batches during each stage. Additionally, during the salt dissolution campaigns, the FTF Catch Tank was utilized to add rain water through a downcomer in the center tank riser access port as needed for volume relief in the FTF Catch Tank. Following liquid additions, the water was recirculated (internal to the tank) using the transfer pump, and a sample was pulled to confirm the target specific gravity (SpG) of the dissolved salt solution was achieved. The dissolved salt solution was then transferred to the receipt tank (Tank 7), and the mixing eductors were lowered as close to the new bulk salt layer as possible, to support subsequent dissolution campaigns. While the mixing jets were able to dissolve salt successfully in Tank 3, they did not do so in a completely uniform manner. Throughout dissolution, mounds were discovered under Riser 1, Riser 2, and the Center Riser. The mixing jets dissolved the salt around the edges of the tank well but were not as effective toward the center of the tank. FTF Catch Tank additions through the center tank riser access port downcomer were required to impact the mound under the center tank riser. FTF Catch Tank additions were sporadic as they were dependent on rainfall in the area. Additionally, all mixing jets were rarely able to be lowered to the same elevation, indicating some mounding in the bulk salt layer. Indexing of the mixing jets was also utilized to impact the salt mounds. Overall, Tank 3 salt dissolution was successful as approximately 1,476,000 L (390,000 Gal) of dissolved salt solution was transferred to Tank 7 over six stages. Slightly less than 852,000 L (225,000 Gal) of water were added to Tank 3. The original material balance prediction estimated that the bulk salt level in Tank 3 would be 3.88 m (152.8 in) after six salt dissolution stages. After six stages the actual bulk salt level was 3.38 m (133 in). This paper will discuss the salt removal strategy, each salt dissolution stage, and lessons learned for future salt dissolution. (authors)