At least 73 records · Page 4

TlCaBaCuO high Tc superconducting microstrip ring resonators designed for 12 GHz

Microwave properties of sputtered Tl-Ca-Ba-Cu-O thin films were investigated by designing, fabricating, and testing microstrip ring resonators. Ring resonators designed for 12 GHz fundamental resonance frequency, were fabricated and tested. From the unloaded Q values for the resonators, the surface resistance was calculated by separating the conductor losses from the total losses. The penetration depth was obtained from the temperature dependence of resonance frequency, assuming that the shift in resonance frequency is mainly due to the temperature dependence of penetration depth. The effective surface resistance at 12 GHz and 77 K was determined to be between 1.5 and 2.75 mOmega, almost an order lower than Cu at the same temperature and frequency. The effective penetration depth at 0 K is approximately 7000 A.

Subramanyam, G.↗

Aircraft-based radiometric imaging of tropospheric temperature and precipitation using the 118.75-GHz oxygen resonance

Passive microwave imaging of O2 emissions using the 118.75-GHz resonance has been investigated for tropospheric and stratospheric remote sensing of atmospheric temperature and precipitation. An imaging millimeter-wave spectrometer (MTS) using eight double-sideband channels centered around the 118.75-GHz resonance, and including a fixed-beam 53.65-GHz radiometer and video camera was constructed. The MTS collected data during 33 flights of the NASA-ER-2 high-altitude aircraft in 1986 during GALE and Cohmex, yielding the first high-spatial-resolution microwave images of atmospheric O2 brightness. The isolated 118-GHz line offers higher spatial resolution and precipitation sensitivity than O2 lines in the 5-mm band near 60 GHz. The brightness temperature perturbations of clouds in nonprecipitating regions are typically twice as large in the 118-GHz channels. However, observations over cirrus anvils show that the 118-GHz brightnesses are not adversely sensitive to some optically opaque cloud cover. Thus these channels are expected to be useful for temperature sounding in the presence of clouds, although retrieval ambiguities can result from variations in the water-vapor profile and surface emissivity.

Gasiewski, A. J.↗

High sensitivity real-time NVR monitor

A real time non-volatile residue (NVR) monitor, which utilizes surface acoustic wave (SAW) resonators to detect molecular contamination in a given environment. The SAW resonators operate at a resonant frequency of approximately 200 MHz-2,000 MHz which enables the NVR monitor to detect molecular contamination on the order of 10.sup.-11 g-cm.sup.-2 to 10.sup.-13 g-cm.sup.2. The NVR monitor utilizes active temperature control of (SAW) resonators to achieve a stable resonant frequency. The temperature control system of the NVR monitor is able to directly heat and cool the SAW resonators utilizing a thermoelectric element to maintain the resonators at a present temperature independent of the environmental conditions. In order to enable the direct heating and cooling of the SAW resonators, the SAW resonators are operatively mounted to a heat sink. In one embodiment, the heat sink is located in between the SAW resonators and an electronic circuit board which contains at least a portion of the SAW control electronics. The electrical leads of the SAW resonators are connected through the heat sink to the circuit board via an electronic path which prevents inaccurate frequency measurement.

Bowers, William D.↗

The influence of wall resonances on the levitation of objects in a single-axis acoustic processing chamber

Instabilities were observed in high temperature, single axis acoustic processing chambers. At certain temperatures, strong wall resonances were generated within the processing chamber itself and these transverse resonances were thought sufficient to disrupt the levitation well. These wall resonances are apparently not strong enough to cause instabilities in the levitation well.

Ross, B. B.↗

A Lack of Spin-Orbit Signal in the Morphology of Mercury's Large Craters

The spatial structure of Mercury's thermal lithosphere depends on the balance between internal heat and surface temperature as controlled by solar insolation. For bodies not in a spin-orbital resonance, observed spatial temperature variations are due to internal heating variations. However, for Mercury's present 3:2 spin-orbit coupling a notable difference of ~150 K exists for the sub-skin depth temperature of the crust as a function of longitude (Fig 1B.; [1,2]). Mercury's longitudinal "hot poles" and "cold poles", in addition to the standard poles (i.e. North and South), have large temperature contrasts that could lead to systematic differences in crater size, morphology, or morphometry, especially for large impacts.

Mercury↗

A Technique for Adjusting Eigenfrequencies of WGM Resonators

A simple technique has been devised for making small, permanent changes in the eigenfrequencies (resonance frequencies) of whispering-gallery-mode (WGM) dielectric optical resonators that have high values of the resonance quality factor (Q). The essence of the technique is to coat the resonator with a thin layer of a transparent polymer having an index of refraction close to that of the resonator material. Successive small frequency adjustments can be made by applying successive coats. The technique was demonstrated on a calcium fluoride resonator to which successive coats of a polymer were applied by use of a hand-made wooden brush. To prevent temperature- related frequency shifts that could interfere with the verification of the effectiveness of this technique, the temperature of the resonator was stabilized by means of a three-stage thermoelectric cooler. Measurements of the resonator spectrum showed the frequency shifts caused by the successive coating layers.

Strekalov, Dmitry↗

Microwave and millimeter-wave resonant-tunneling devices

Resonant-tunneling devices in microelectronic component form, whose structure is the electron analog of a Fabry-Perot resonator, encompass oscillators, self-oscillating mixers, and harmonic multipliers. The negative differential resistance characteristic of these devices has been obtained at room temperature, and resonant-tunneling transistors capable of operation in the THz-frequency range appear to be feasible. Three-terminal resonant-tunneling device development is in its infancy, as is that of devices for digital applications.

Sollner, T. C. L. Gerhard↗

Engineering a laser remote sensor for atmospheric pressure and temperature

A system for the remote sensing of atmospheric pressure and temperature is described. Resonant lines in the 7600 Angstrom oxygen A band region are used and an organic dye laser beam is tuned to measure line absorption changes with temperature or pressure. A reference beam outside this band is also transmitted for calibration. Using lidar techniques, profiling of these parameters with altitude can be accomplished.

Kalshoven, J. E., Jr.↗

Deposition temperature dependence of the deep defect density for a-Si:H films grown by electron cyclotron resonance microwave plasma

The dependence on deposition temperature of the mobility gap density of states has been determined for hydrogenated amorphous silicon (a-Si:H) films grown by electron cyclotron resonance (ECR) microwave plasma CVD. A minimum in the integrated deep defect density of 1 x 10 exp 16/cu cm was found to occur at a temperature of approximately 250 C, while an Urbach slope minimum of 52 meV was observed at 175 C under our deposition conditions. Based on these measurements the ECR-grown films were found to be of excellent device quality and comparable to a-Si:H films grown by RF plasma-enhanced CVD.

Essick, J. M.↗

Pulse tube cooler having 1/4 wavelength resonator tube instead of reservoir

An improved pulse tube cooler having a resonator tube connected in place of a compliance volume or reservoir. The resonator tube has a length substantially equal to an integer multiple of 1/4 wavelength of an acoustic wave in the working gas within the resonator tube at its operating frequency, temperature and pressure. Preferably, the resonator tube is formed integrally with the inertance tube as a single, integral tube with a length approximately 1/2 of that wavelength. Also preferably, the integral tube is spaced outwardly from and coiled around the connection of the regenerator to the pulse tube at a cold region of the cooler and the turns of the coil are thermally bonded together to improve heat conduction through the coil.

Gedeon, David R.↗

Feasibility Study of Velocity and Temperature Measurements of an Arcjet Flow using Laser Resonance Doppler Velocimetric (LRDV) Technique

Thermal Protection System (TPS) materials are used in space vehicles to shield from high heating environment encountered during their atmospheric reentry. Arcjet wind tunnels are used to simulate the flowfield encountered by the spacecrafts, and are used for testing TPS materials. How well these tests simulate the actual heating environment encountered by space vehicles depends on the characteristics of the simulated flow. The flow characterization requires the determination of temperature, concentration, and velocity of the various atomic and molecular species present in the flow. However, determining these parameters requires a complex set of both analytical and experimental procedures. The ability to properly simulate the flight environment is directly related to the accuracy with which these techniques can be used to define the arcjet Laser Resonance Doppler Velocimetric (LRDV) technique can be used to accurately determine the velocity and temperature of a gaseous species. In this technique, the medium is probed with a laser beam that is in resonance with an absorbing transition of the species. The absorption lineshape is Doppler-shifted due to the flow velocity of the species, and the frequency shift is detected as the variation in intensity of the fluorescence emitted by the species. Thus a measurement of the Doppler shift and the width of a spectral line can give both the temperature and the velocity of the flowfield. This summer, our project was to make a feasibility study to set up an experimental arrangement for the laser resonance Doppler velocimetric technique using a ring dye laser. Experiments required troubleshooting, cleaning, testing, and alignment of two lasers and several diagnostics instruments. All instruments and lasers necessary for the project worked well, but the output power of the broadband fundamental dye laser was limited to about 20 mW. This was quite low as compared to that necessary to obtain second harmonic oscillation at 327.49 nm for the LRDV studies. Further optimization of the dye laser optical elements is necessary before it can be used for the experiment, which requires narrowband (about 20 Mhz) laser operation.

Rob, Mohammad A.↗

Solid state crystal physics at very low temperatures

The mechanical dissipation (Q) and resonant frequency of a 15 kg silicon crystal were measured at cryogenic temperatures. In the experiment described, temperature control was incorporated to reduce the time derivative of the temperature. The results of the Q measurements with and without this temperature control are quite different. Measurements of the resonant frequency of the fundamental longitudinal mode of the silicon crystal from 6 to 300 Kelvin are presented and discussed with respect to temperature, df/dT. It is observed that frequency increases as temperature decreases down to about 16 Kelvin, i.e. dt/dT is negative. However, below this temperature the frequency decreases as temperature decreases, i.e. dt/dT is positive. It is suggested that this behavior is related to the coefficient of thermal contraction of silicon, which changes sign at 18 Kelvin. Continuation of these experiments to 20 mK is discussed.

Davis, W.↗

Experimental investigation of resonance self-shielding and the Doppler effect in uranium and tantalum

A series of average transmission and average self-indication ratio measurements were performed in order to investigate the temperature dependence of the resonance self-shielding effect in the unresolved resonance region of depleted uranium and tantalum. The measurements were carried out at 77 K, 295 K and approximately 1000 K with sample thicknesses varying from approximately 0.1 to 1.0 mean free path. The average resonance parameters as well as the temperature dependence were determined by using an analytical model which directly integrates over the resonance parameter distribution functions.

Byoun, T. Y.↗