Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “resonance frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Electron density measurement using a partially covered hairpin resonator in an inductively coupled plasma

Hairpin probes are used to determine electron densities via measuring the shift of the resonant frequency of the probe structure when immersed in a plasma. This manuscript presents new developments in hairpin probe hardware and theory that have enabled measurements in a high electron density plasma, up to approximately 10 12 cm -3 , corresponding to a plasma frequency of about 9 GHz. Hardware developments include the use of both quarter-wavelength and three-quarter-wavelength partially covered hairpin probes in a transmission mode together with an easily reproducible implementation of the associated microwave electronics using commercial off-the-shelf components. The three-quarter-wavelength structure is operated at its second harmonic with the purpose of measuring higher electron densities. New theory developments for interpreting the probe measurements include the use of a transmission line model to find an accurate relationship between the resonant frequency of the probe and the electron density, including effects of partially covering the probes with epoxy. Measurements are taken in an inductively coupled plasma sustained in argon at pressures below 50 mTorr. Results are compared with Langmuir probe and interferometry measurements.

47 OTHER INSTRUMENTATION↗

Infrared-active phonon modes in single-crystal thorium dioxide and uranium dioxide

The infrared-active phonon modes, in single-crystal samples of thorium dioxide (ThO 2 ) and uranium dioxide (UO 2 ), were investigated using spectroscopic ellipsometry and compared with density functional theory. Both ThO 2 and UO 2 are found to have one infrared-active phonon mode pair [consisting of one transverse optic (TO) and one associated longitudinal optic (LO) mode], which is responsible for the dominant features in the ellipsometric data. Furthermore, at room temperature, our results for the mode pair’s resonant frequencies and broadening parameters are comparable with previous reflectance spectroscopy characterizations and density functional theory predictions. For ThO 2 , our ellipsometry and density function theory results both show that the LO mode broadening parameter is larger than the TO mode broadening. This signifies mode anharmonicity, which can be attributed to the intrinsic phonon–phonon interaction. In addition to the main mode pair, a broad low-amplitude impurity-like vibrational mode pair is detected within the reststrahlen band for both ThO 2 and UO 2 . Elevated temperature measurements were performed for ThO 2 in order to study the mechanisms by which the phonon parameters evolve with increased heat. The observed change in the TO resonant frequency is in excellent agreement with previous density functional calculations, which only consider volume expansion of the crystal lattice. This suggests that the temperature-dependent change in the TO frequency is primarily due to volume expansion. The change in the main mode pair’s broadening parameters is nearly linear within the temperature range of this study, which indicates the intrinsic anharmonic scattering (via cubic anharmonicities) as the main decay mechanism.

36 MATERIALS SCIENCE↗

Dark matter axion search using a Josephson Traveling wave parametric amplifier

Here, we describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion–photon couplings above 10 -13 Ge V -1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7–4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.

47 OTHER INSTRUMENTATION↗

Broadband Ultra-Sensitive Adiabatic Magnetometer

We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. In conclusion, we experimentally conducted alkali-metal density measurements, as an example of applications.

adiabatic magnetometer↗

Strain-tunable microwave-resonance technique for quantum materials

By integrating a dielectric microwave resonator with a piezoelectric-based strain device, we develop an in situ strain-tunable microwave spectroscopy technique that enables contactless measurements of material properties under strain. To demonstrate the capability of this device, we measure the strain-dependent microwave surface impedance of the representative iron-based superconductor Ba⁢Fe 2 (As 1−𝑥 ⁢P 𝑥 ) 2 at the slightly overdoped composition. We successfully control and observe the suppression of superconductivity under both compressive and tensile anisotropic lattice distortions along the tetragonal [110] T direction, as manifested by changes in the quality factor and resonance frequency shifts of microwave resonance. Furthermore, strain-induced changes in microwave surface resistivity, an extension of conventional DC-limit transport elastoresistivity to the microwave regime, provide information on electronic anisotropy equivalent to that of DC elastoresistivity, while offering a contactless alternative. Furthermore, our strain-tunable cavity therefore serves as a powerful, contactless probe of fundamental material properties under strain and may also potentially facilitate the design of hybrid quantum systems with strain-engineered quantum degrees of freedom.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Final Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have developed a continuum electromechanics model of the microwave resonant cavity transducer performance. The deflection of the membrane is calculated using equations from the theory of plates and shells for deflection of radially constrained thin circular disk under uniform load. The microwave frequency shift is calculated using the equations from the microwave cavity perturbation theory. The transducer model was validated with proof-of-concept experimental data of water flow sensing with a Brass 360 right circular cylinder with 22.2mm diameter and 203µm thick wall. The cavity was excited through a subwavelength hole in TE 011 mode with resonant frequency f ≈ 17.8GHz. Subsequently, we have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. For this test, we have developed a cylindrical resonator with the same dimensions as for the Brass 360 cavity. The resonator for high temperature liquid sodium test was machined from stainless steel 316 and electroplated with silver on the interior surfaces. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. The sodium flow sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred kHz was observed. The transducer was removed after 70 days of testing. No visual damage was observed, and the electromagnetic response remained the same. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Water flow sensing was performed before and after liquid sodium test. The responses in both cases are similar and agree with COMSOL computer simulations. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Beehive haloscope for high-mass axion dark matter

We propose a new haloscope geometry that can arbitrarily increase the resonator volume for a given target axion mass. This geometry consists of closely packed, overlapping coaxial cavities operating as a single resonator. While the resonant frequency is still determined by the dimensions of the individual “cells,” the strong interactions between the cells encourage the entire “beehive” to oscillate in phase, a phenomenon expected of tightly coupled harmonic oscillators. This synchronization behavior allows the construction of a singly connected large volume resonator at high frequency by simply increasing the number of the cells. Using direct numerical simulations, we verify the existence of a global eigenmode that has a high (40%) form factor in a 169-element beehive resonator. The resonant frequency of the eigenmode is tunable by moving the center rods laterally in unison. The form factor is very tolerant to dimensional deviations and misalignment as a result of mode hybridization due to strong coupling. The beehive haloscope inherits many appealing properties from the conventional coaxial cavity: a high quality factor, compatibility with a solenoid magnet, and ease of fabrication, tuning, and coupling. We argue that this geometry is an excellent candidate for high-mass axion searches covering the post-inflationary parameter space (>5 GHz).

47 OTHER INSTRUMENTATION↗

Mutually guided light and particle beam propagation

The polarizability of atoms and molecules gives rise to optical forces that trap particles and a refractive index that guides light beams, potentially leading to a self-guided laser and particle beam propagation. In this paper, the mutual interactions between an expanding particle beam and a diffracting light beam are investigated using an axisymmetric particle-light coupled simulation. The nonlinear coupling between particles and photons is dependent on the particle beam radius, particle density, particle velocity and temperature, polarizability, light beam waist, light frequency (with respect to the resonance frequency), and light intensity. The computational results show that the maximum propagation distance is achieved when the waveguiding effect is optimized to single-mode operation. The application of the coupled beam propagation as a space propulsion system is discussed.

42 ENGINEERING↗

Tuned oscillator atomic force microscopy methods and apparatus

Techniques for operating an atomic force microscope, the atomic force microscope comprising a cantilever and configured to image a surface of a sample using a probe tip coupled to the cantilever, the techniques comprising using a controller to perform: obtaining, based on at least one intrinsic parameter of the cantilever, a first quality factor and a first free oscillation amplitude, wherein the cantilever exhibits only one stable oscillation state when oscillating at the first free oscillation amplitude and operating at the first quality factor; and controlling the cantilever to exhibit the only one stable oscillation state by controlling the cantilever to oscillate at a fixed frequency at or near a resonance frequency of the cantilever, oscillate at the first free oscillation amplitude, and operate at the first quality factor.

Schwarz, Udo↗

Electromagnetic response of disordered superconducting cavities

We present the results for the resonant frequency shift and quality factor of disordered niobium (Nb) superconducting radio-frequency cavities driven out of equilibrium by the resonant microwave field. The theory is based on the non-equilibrium theory of superconductivity for the current response to the electromagnetic field at the vacuum–metal interface. We are able to accurately predict the observed frequency shifts with a precision of order fractions of kHz over the full temperature range 0 < T ≤ T c , including the negative frequency shift anomalies that are observed very near T c . The origin of these anomalies is shown to be the competition between the normal metal skin depth and the London penetration depth, which diverges as T→T c ⁻. An analytical approximation to the full current response, valid for |T-Tc| $\ll$ Tc, accounts for the negative frequency shift near T c . The non-monotonic dependence of the quality factor on the quasiparticle scattering rate is related to the pair-breaking effect of disorder on the superfluid fraction and, thus, the London penetration depth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Validation of CFD simulations of the moored DeepCwind offshore wind semisubmersible in irregular waves

This article examines the use of computational fluid dynamics (CFD) simulations to predict the response of a floating wind platform to irregular-wave excitation. This work was conducted as part of the Reproducible CFD Joint Industry Project for Floating Offshore Wind Applications and involved verification across several participants and modeling tools and validation against experiments. The authors pay special attention to the uncertainties in both CFD results and experimental measurements. In this work, we perform detailed comparisons of the incident waves and the motion of a moored structure. The nonlinear, low-frequency resonance motion is of particular interest because it potentially drives the mooring and tower-base loads. The verification and validation study is partially successful in that the CFD simulations capture the low-frequency slow-drift motion well but underpredict the low-frequency pitch resonance. This underprediction can be attributed in part to the CFD incident waves, which showed some discrepancies with the experimental waves, especially around extreme events. The effects of the wave discrepancies are also estimated and investigated using a mid-fidelity OpenFAST model. Overall, the present study increases our confidence in using CFD simulations to predict the global performance of offshore wind platforms in irregular waves and to produce data for the calibration of lower-fidelity models.

17 WIND ENERGY↗

Asymmetrical cavity design that bypasses mode mixings in axion haloscope experiments

Microwave cavities used in axion haloscope experiments typically employ a tuning rod as a means to widen the range of resonance frequencies at which it is sensitive to axion-to-photon conversion. A realistic tuning mechanism requires a gap between the cavity end caps and the tuning rod to ensure movement, and causes some modes to hybridize with the resonant mode that is being tracked for the experiment. These so-called mode mixings lead to gaps in the frequency range that practically lose sensitivity to axions. Here, to solve this problem, we present a cavity design which, for two tuning rod configurations corresponding to a lower and higher frequency range, have a dielectric rod inserted at a specific location that makes the cavity asymmetrical. Moving the tuning rod closer to the dielectric insert changes the location and frequency of the mode mixing compared to when it is farther away from it. This design is easily realizable in practical experiments and makes possible an axion dark matter search with minimal loss in sensitivity due to mode mixings. We also show that the same design has the same desired effect when cavity dimensions are scaled down to be smaller and are at higher resonance frequencies.

Axion↗

Modeling frequency instability in high-quality resonant experiments

Modern resonant sensing tools can achieve increasingly high quality factors, which correspond to extremely narrow linewidths. In such systems, time variation of the resonator’s natural frequency can potentially impact its ability to accumulate power and its resulting sensitivity. One such example is the Dark SRF experiment, which utilizes superconducting radio frequency (SRF) cavities with quality factors of Q ∼ 10 10 . Microscopic deformations of the cavity lead to stochastic jittering of its resonant frequency with amplitude 20 times its linewidth. Naively, one may expect this to lead to a large suppression in accumulated power. In this work, we study in detail the effects of frequency instability on high-quality resonant systems, utilizing the Dark SRF experiment as a case study. We show that the timescale of jittering is crucial to determining its effect on power accumulation. Namely, when the resonant frequency varies sufficiently quickly, the system accumulates power as if there were no jittering at all. This implies that the sensitivity of a jittering resonator is comparable to that of a stable resonator. In the case of Dark SRF, we find that jittering only induces a ∼ 10 % loss in power. Our results allow the dark-photon exclusion bound from Dark SRF’s pathfinder run to be refined, leading to a constraint that is an order of magnitude stronger than previously reported (corresponding to a signal-to-noise ratio that is four orders of magnitude larger). This result represents the world-leading constraint on dark photons over a wide range of masses below 6 μ eV and translates to the best laboratory-based limits on the photon mass m γ < 2.9 × 10 - 48 g .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trapping of lithium atoms in a large hollow optical dipole trap

We describe the trapping of lithium atoms in an optical dipole trap about 1 mm in size, with a nearly rectangular potential. The trap has the shape of a cylinder with flat bases. The confinement region is bounded by thin walls produced by light with a frequency blue-detuned from an atomic transition (resonance) frequency by 19 GHz. Before trapping, the gas is collected and cooled in a magneto-optical trap whose centre nearly coincides with the centre of the dipole trap. After switching off the magneto-optical trap, we have photographed the atoms remaining in the dipole trap. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OC7 phase I: Toward practical sea-state-dependent modeling of hydrodynamic viscous drag and damping

Here, this article presents a collaborative research campaign under the OC7 project on refining the engineering modeling approach for hydrodynamic viscous drag and damping on floating wind platforms, focusing on the adjustment of hydrodynamic drag and damping coefficients for different sea states. The participant simulation results show significant improvements over the previous OC6 project in predicting the low-frequency resonance motion under nonoperational conditions. The improvements are mainly due to enhanced modeling, including the adoption of wave stretching, and directly tuning the coefficients to measured platform motion in waves instead of free decay. For accurate predictions of mean- and slow-drift motion, the better performing models use a decreasing column splash zone drag coefficient and increasing surge damping/drag with increasing wave height. The model tuning for heave and pitch resonance shows less consistency. Generally, both quadratic drag and additional heave or pitch damping are needed for accurate predictions. Alternatively, a quadratic drag formulation with velocity filtering for the rectangular pontoons leads to improved predictions without additional damping. This model is also potentially more predictive, requiring minimal adjustment to its parameters for different conditions.

17 WIND ENERGY↗

Thermal hysteresis controlled reconfigurable MoS 2 nanomechanical resonators

Two-dimensional (2D) structures from layered materials have enabled a number of novel devices including resonant nanoelectromechanical systems (NEMS). 2D NEMS resonators are highly responsive to strain, allowing their resonance frequencies to be efficiently tuned over broad ranges, which is a feature difficult to attain in conventional micromachined resonators. In electrically configured and tuned devices, high external voltages are typically required to set and maintain different frequencies, limiting their applications. Here we experimentally demonstrate molybdenum disulfide (MoS 2 ) nanomechanical resonators that can be reconfigured between different frequency bands with zero maintaining voltage in a non-volatile fashion. By leveraging the thermal hysteresis in these 2D resonators, we use heating and cooling pulses to reconfigure the device frequency, with no external voltage required to maintain each frequency. Here, we further show that the frequency spacing between the bands can be tuned by the thermal pulse strength, offering full control over the programmable operation. Such reconfigurable MoS 2 resonators may provide an alternative pathway toward small-form-factor and low-power tunable devices in future reconfigurable radio-frequency circuits with multi-band capability.

42 ENGINEERING↗

Approaching the Strain-Free Limit in Ultrathin Nanomechanical Resonators

Ultrathin mechanical structures are ideal building platforms to pursue the ultimate limit of nanomechanical resonators for applications in sensing, signal processing, and quantum physics. Unfortunately, as the thickness of the vibrating structures is reduced, the built-in strain of the structural materials plays an increased role in determining the mechanical performance of the devices. As a consequence, it is very challenging to fabricate resonators working in the modulus-dominant regime, where their dynamic behavior is exclusively determined by the device geometry. In this Letter, we report ultrathin doubly clamped nanomechanical resonators with aspect ratios as large as L/t similar to 5000 and working in the modulus-dominant regime. Here, we observed room temperature thermomechanically induced motion of multiple vibration modes with resonant frequencies closely matching the predicted values of Euler-Bernoulli beam theory under an axial strain of 6.3 x 10 -8 . The low strain of the devices enables a record frequency tuning ratio of more than 50 times. These results illustrate a new strategy for the quantitative design of nanomechanical resonators with unprecedented performance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗