OpenStudio® HPXML workflow [SWR-25-13]

OpenStudio-HPXML allows running residential EnergyPlus™ simulations using an HPXML file for the building description. It is intended to be used by user interfaces or other automated software workflows that automatically produce the HPXML file. OpenStudio-HPXML can accommodate a wide range of different building technologies and geometries. End-to-end simulations typically run in 3-10 seconds, depending on complexity, computer platform and speed, etc. For more information on running simulations, generating HPXML files with the appropriate inputs to run EnergyPlus, etc., please visit the documentation linked below. https://openstudio-hpxml.readthedocs.io/en/latest

Horowitz, Scott↗

Virtual Refrigerant Charge Sensing Method for Next-Generation Refrigerant in Residential Heat Pumps

The charge level of refrigerant in heat pump systems significantly affects their operational performance. Virtual refrigerant charge (VRC) sensing technology has been well-established for traditional refrigerants (HFCs and HCFCs) for its low cost compared to physical sensors. However, other than traditional refrigerants, HFOs are increasingly used in next-generation heat pumps; whether these conventional VRC sensing methods remain applicable for heat pump systems utilizing next-generation refrigerants requires further investigation. To address these issues, this study develops a low-cost VRC sensing method for next-generation refrigerant heat pumps used in residential buildings. The developed algorithm is evaluated by using simulation models to evaluate the accuracy, considering an R454B heat pump with a nominal heating capacity of 51K Btu/hr (14.95 kW) as an example, and compared with those of the two reference VRC sensing algorithms. Though the developed VRC sensing algorithm and the two reference methods can accurately predict the charge level for the R454B heat pump system (with mean absolute percentage error for various cooling and heating conditions less than 7%), the developed VRC sensing algorithm uses fewer sensors and improves the overall accuracy for heating conditions by 7.1%, and the accuracy for undercharge cooling conditions 14.2%, compared with a mainstream algorithm. This technology will complement physical leakage detectors, and promote the adoption of next-generation heat pump systems, along with reducing wasted energy and maintenance costs.

Liang, Chenjiyu↗

Using Residential and Office Building Archetypes for Energy Efficiency Building Solutions in an Urban Scale: A China Case Study

Building energy consumption accounts for 36% of the overall energy end use worldwide and is growing rapidly as developing countries continue to urbanize. Understanding the energy use at urban scale will lay the foundation for identification of energy efficiency opportunities to be deployed at speed. China has almost half of global new constructions and plays an important role in building suitability. However, an open source national building energy consumption database is not available in China. To provide data support for building energy consumptions, this paper used a simulation method to develop an urban building energy consumption database for a pilot city in Wuhan, China. First, residential, small, and large office building archetype energy models were created in EnergyPlus to represent typical building energy consumption in Wuhan. The baseline reference model simulation results were further validated using survey data from the literature. Second, stochastic simulations were conducted to consider different design parameters and occupants’ energy usage intensity scenarios, such as thermal properties of the building envelope, lighting power density, equipment power density, HVAC (heating, ventilation and air conditioning) schedule, etc. A building energy consumption database was generated for typical building archetypes. Third, data-driven regression analysis was conducted to support quick building energy consumption prediction using key high- level building information inputs. Finally, a web-based urban energy platform and an interface were developed to support further third-party application development. The research is expected to provide fast energy efficiency building design solutions for urban planning, new constructions as well as building retrofits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing residential activity in a home plumbing system simulator: monitoring the occurrence and relationship of major opportunistic pathogens and phagocytic amoebas

Opportunistic premise plumbing pathogens (OPPPs) have been detected in buildings’ plumbing systems causing waterborne disease outbreaks in the United States. In this study, we monitored the occurrence of OPPPs along with free-living amoeba (FLA) and investigated the effects of residential activities in a simulated home plumbing system (HPS). Water samples were collected from various locations in the HPS and analyzed for three major OPPPs: Legionella pneumophila, nontuberculous mycobacterial species (e.g., Mycobacterium avium, M. intracellulare, and M. abscessus), and Pseudomonas aeruginosa along with two groups of amoebas (Acanthamoeba and Vermamoeba vermiformis). A metagenomic approach was also used to further characterize the microbial communities. Results show that the microbial community is highly diverse with evidence of spatial and temporal structuring influenced by environmental conditions. L. pneumophila was the most prevalent pathogen (86% of samples), followed by M. intracellulare (66%) and P. aeruginosa (21%). Interestingly, M. avium and M. abscessus were not detected in any samples. The data revealed a relatively low prevalence of Acanthamoeba spp. (4%), while V. vermiformis was widely detected (81%) across all the sampling locations within the HPS. Locations with a high concentration of L. pneumophila and M. intracellulare coincided with the highest detection of V. vermiformis, suggesting the potential growth of both populations within FLA and additional protection in drinking water. After a period of stagnation lasting at least 2-weeks, the concentrations of OPPPs and amoeba immediately increased and then decreased gradually back to the baseline. Furthermore, monitoring the microbial population after drainage of the hot water tank and partial drainage of the entire HPS demonstrated no significant mitigation of the selected OPPPs. This study demonstrates that these organisms can adjust to their environment during such events and may survive in biofilms and/or grow within FLA, protecting them from stressors in the supplied water.

59 BASIC BIOLOGICAL SCIENCES↗

Optimal Efficiency and Operational Cost Savings: A Framework for Automated Rooftop PV Placement

Residential energy consumers are charged based on a utility rate structure, such as net metering or feed-in tariff. To lower consumers' electricity bills, expensive batteries are deployed to reduce the electricity fed from the grid during peak hours. However, strategic photovoltaic (PV) panel placement enables the reduction of operational energy cost while considering the spatial feasibility and efficiency for hosting rooftop PV. In this paper, we present a framework to automatically identify the optimal location of rooftop PV panels on residential buildings. Our framework integrates multiple workflows, including energy and environmental simulation, parametric modeling, and optimization to identify the ideal location of PV panels to balance the demand and supply at a building and community scale. These workflows are linked using the Grasshopper plug-in for Rhinoceros CAD software. The framework includes two different workflows, each satisfying a target for optimal PV placement: (a) maximizing PV panel efficiency, where users aim to maximize energy generation, and (b) minimizing operational energy cost, where "best'' panels are selected considering utility rates for operational energy cost. Our framework is demonstrated in a residential community in Fort Collins, Colorado, to generate the optimal PV placement for each of the two aforementioned targets. Results from the two workflows are compared to illustrate the effect of PV location and orientation on solar energy production efficiency and operational energy cost. The developed workflows are introduced as tools within the Grasshopper plug-in to investigate the solar potential of rooftop PV panels while taking into account factors such as contextual shading, utility rate structures, and buildings' energy demand profiles.

30 DIRECT ENERGY CONVERSION↗

Simulating dispatchable grid services provided by flexible building loads: State of the art and needed building energy modeling improvements

End-use electrical loads in residential and commercial buildings are evolving into flexible and cost-effective resources to improve electric grid reliability, reduce costs, and support increased hosting of distributed renewable generation. This article reviews the simulation of utility services delivered by buildings for the purpose of electric grid operational modeling. We consider services delivered to (1) the high-voltage bulk power system through the coordinated action of many, distributed building loads working together, and (2) targeted support provided to the operation of low-voltage electric distribution grids. Although an exhaustive exploration is not possible, we emphasize the ancillary services and voltage management buildings can provide and summarize the gaps in our ability to simulate them with traditional building energy modeling (BEM) tools, suggesting pathways for future research and development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model Predictive Control of Discrete-Continuous Energy Systems via Generalized Disjunctive Programming

Generalized Disjunctive Programming (GDP) provides an alternative framework to model optimization problems with both discrete and continuous variables. The key idea behind GDP involves the use of logical disjunctions to represent discrete decisions in the continuous space, and logical propositions to denote algebraic constraints in the discrete space. Compared to traditional mixed-integer programming (MIP), the inherent logic structure in GDP yields tighter relaxations that are exploited by global branch and bound algorithms to improve solution quality. In this paper, we present a general GDP model for optimal control of hybrid systems that exhibit both discrete and continuous dynamics. Specifically, we use GDP to formulate a model predictive control (MPC) model for piecewise-affine systems with implicit switching logic. As an example, the GDP-based MPC approach is used as a supervisory control to improve energy efficiency in residential buildings with binary on/off, relay-based thermostats. A simulation study is used to demonstrate the validity of the proposed approach, and the improved solution quality compared to existing MIPbased control approaches.

Bhattacharya, Arnab↗

Performance analysis of novel thermal storage integrated heat pump system in a residential building at the hot climate for demand flexibility

A novel thermal energy storage integrated heat pump system was proposed to reshape the electricity load profile of residential buildings while maintaining thermal comfort. High-fidelity computer simulations are needed for evaluating the feasibility of the proposed system. This study investigates the annual performance of the proposed system through Modelica-based system simulations. A rule-based control strategy was developed to shift the electric demand of a typical single-family house in Atlanta, GA from peak to off-peak hours to utilize the Time-of-Use electricity rate to lower the energy costs for conditioning the building. For comparison, a conventional air-source heat pump system serving the same building was also developed. Simulation results indicate that the proposed system is capable of shifting around 90% of the building's electricity consumption for meeting the thermal demand from peak to off-peak hours on a daily basis. In addition, the annual power consumption and operating cost for running the HVAC system can be reduced by 6% and 34%, respectively, compared with the conventional air-source heat pump.

Shi, Liang↗

ResStock™ v3.2.0 [SWR-19-15 and SWR-20-07]

The ResStock™ analysis tool was built on NREL's OpenStudio® platform, and is a project geared at modeling existing residential building stocks at national, regional, or local scales with a high-degree of granularity (e.g., one physics-based simulation model for every 200 dwelling units), using the EnergyPlus® simulation engine. Information about ComStock™, a sister tool for modeling the commercial building stock, can be found here: https://www.nrel.gov/buildings/comstock.html This repository contains: Housing characteristics of the U.S. residential building stock, in the form of conditional probability distributions stored as tab-separated value (.tsv) files. Comments at the bottom of each file document data sources and assumptions for each. A library of housing characteristic "options" that translate high-level characteristic parameters into arguments for OpenStudio measures, and which are referenced by the housing characteristic .tsv files and building energy upgrades defined in project definition files Project definition files: v2.3.0 and later: buildstockbatch YML files openable in any text editor v2.2.5 and prior: Project folder openable in PAT Unit-level OpenStudio Measures for automatically constructing OpenStudio Models of each representative dwelling unit model: v3.0.0 and later: OpenStudio-HPXML Measures v2.5.0 and prior: OpenStudio Measures Higher-level OpenStudio Measures for controlling simulation inputs and outputs This repository does not contain software for running ResStock simulations, which can be found as follows: Versions 2.3.0 and later only support the use of buildstockbatch for deploying simulations on high-performance or cloud computing. Version 2.3.0 also removed separate projects for single-family detached and multifamily buildings, in lieu of a combined project_national representing the U.S. residential building stock. See the changelog for more details. Versions 2.2.5 and prior support the use of the publicly available OpenStudio-PAT software as an interface for deploying simulations on cloud computing. Read the documentation for v2.2.5.

Horowitz, Scott↗

Heterogeneity or illusion? Track the carbon Kuznets curve of global residential building operations

Residential buildings, the “last mile” sector in the global decarbonization, have become the most significant uncertain factor hindering carbon neutrality with increasing household energy demand. To track the operational carbon in buildings, this study investigates the carbon Kuznets curve (CKC) and the corresponding decoupling status of residential building operations at four emission scales by using the data of 30 countries from 2000 to 2019. The results show that (1) the CKC model can fit more than half of the samples. Most curves have an inverted U-shape, with 76% of emission per household and 82% of total emissions. (2) In the presence of the CKC, over four-fifths of global residential buildings peak regardless of any emission scale. The analysis denotes that the carbon emissions of developed countries reach their peaks earlier. In the total emissions, the samples’ peaking proportion is 20% and 25% with income per capita < 20,000 United States dollars (USD) and 20,000–40,000 USD, respectively. (3) The Tapio decoupling analysis and the threshold regression effectively verify the robustness and the heterogeneity of CKCs, respectively. Strong decoupling effects of CKCs in most countries are demonstrated at the scales of emission per floor space and the total emissions, and the heterogeneity proves the classic inverted U-shaped relationship between economy and emissions doesn’t exist in all emitters. Overall, this study tracks the historical carbon emission trajectories of residential building operations at a global scale, providing reference for different economies to simulate the dynamic of building carbon emissions along with the economic booming.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeled Results of Four Residential Energy Efficiency Measure Packages for Deriving Advanced Building Construction Research Targets

The Advanced Building Construction (ABC) Initiative from the U.S. Department of Energy Building Technologies Office is working to accelerate industrialized construction innovations for decarbonizing buildings. To inform performance and cost targets for research under the ABC Initiative, this analysis used the ResStock™ tool to evaluate the energy savings, utility bill impacts, and carbon emissions impacts of four simulated upgrade packages with specific target performance levels on a large sample of residential dwelling units (approximately 550,000) representative of the U.S. housing stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Home energy management under realistic and uncertain conditions: A comparison of heuristic, deterministic, and stochastic control methods

We report home energy management systems (HEMS) have been shown to reduce energy bills and to provide grid services including peak demand reduction and demand flexibility. However, uncertainty in residential energy systems is a significant issue and can reduce the benefits of a HEMS to the homeowner or grid operator. Sources of uncertainty include weather forecasts, predictions of energy-related occupant activities (e.g., hot water draws), and parameter estimation for the building envelope and energy-consuming equipment. This paper tackles the problem of uncertainty by developing a framework that simulates HEMS in uncertain conditions and evaluates the performance of multiple control strategies. A linear, reduced-order residential building model for model predictive control applications is derived and compared to a full-order model. Stochastic model predictive control is shown to perform better than deterministic and heuristic methods when considering realistic forecasts with uncertainty. The framework can evaluate the performance of HEMS in real-world applications, which can help de-risk HEMS deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EUI Benchmarks for Net-Zero Energy Buildings in India

In our study we present EUI benchmarks for NZEBs for six building types across residential and non-residential typologies and for India's five climate zones. This approach is similar to the simulation-based benchmarks used by the B3 program in Minnesota, the Cal-Arch methodology in California, and the US Solar Decathlon approach, which combine simulations with actual building data. Of the six building types we explore one in detail with a range of operation scenarios, specifically narrowing down the EUI benchmarks for mixed-mode building operation and for variable temperature set-points as prescribed in the National Building Code of India.The contribution of this work is to provide rigorous end-use level EUI benchmarks for six building types, and to describe a method for simulation-based EUI benchmarks for mixed-mode operation with variable setpoints to highlight the difference between the standard approach used for the five building types and the On-Site Construction Worker Housing which additionally has the mixed-mode variable setpoint approach.On-Site Construction Worker Housings are typically poorly constructed temporary structures, without adequate thermal comfort, It is critical to provide adequate thermal comfort to protect people from the warming effects of climate change, and to discover super efficient and cost-effective ways to do so.The methodology used for the On-Site Construction Worker Housing (CWH) results in an 80% acceptability according to the India Model for Adaptive Comfort in the National Building Code of India. EUIs of all six buildings are 60% lower than the minimum compliance with India's Energy Conservation Building Codes, providing benchmarks for efficiency levels. The end-use level EUI benchmarks are now provided to over 1800 Solar Decathlon India participants so that they can compare the performance of their NZEB designs.In particular, the CWH results provide an insight into the importance of the mixed-mode operation with variable temperature set-points. The results from the simulation study show that for an NZEB target, the EUI with standard thermal comfort model and without mixed operation is 58.26 kWh/m2*year, while that with the variable set-points of the adaptive model with mixed mode operation is 24.23 kWh/m2*year. This is a 58% reduction in EUI. Given that many building types including residential, and non-residential operate in mixed mode, it is important to take this work further to develop mixed-mode operation NZEB benchmarks so that the carbon intensity of these buildings could be lower than the standard thermal comfort model approach.

benchmarking↗

Field validation of isotropic analytical models for simulating fabric shades

Fabric roller shades are common shading materials used in commercial and residential buildings. Accurately characterizing and modeling shades helps practitioners select the appropriate product and its control strategy based on climate and occupants' priorities, such as visual comfort and view to outdoors. Previous studies established a generalized method for modeling complex fenestration systems using data-driven tabulated bidirectional scattering distribution functions. However, deploying such a method at scale to all fabric shading products on the market is too costly and time-consuming. Analytical models that are based on a limited set of measurements (e.g., normal-normal and normal-hemispherical visible transmittance and reflectance, and directional cut-off angles) can be used to model the wide variety of shading products on the market. This study evaluates the performance of two isotropic analytical models, Roos-Wienold and Modified-Kotey, for modeling fabric roller shades, with a focus on the model's ability to predict occupant visual comfort. The performance evaluation was conducted through laboratory and field measurements and simulations. The results showed that both models are sufficient for predicting vertical illuminance at seated eye-level. Roos-Wienold model was able to predict binary visual comfort classification (glare/no-glare) under a wide range of luminance conditions, while Modified-Kotey model did not perform as well under high-contrast low-adaptation conditions. Both models are insufficient in predicting visual comfort at a four-point scale (e.g., imperceptible, perceptible, disturbing, intolerable). The two isotropic models become less accurate when the fabric exhibits high anisotropy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pathway for decarbonizing residential building operations in the US and China beyond the mid-century

With global carbon budget targets looming, residential buildings in top economies must become carbon neutral as soon as possible to reserve more emission space for emerging carbon-emitting economies. This study is the first to compare the operational decarbonization process of China’s and the United States (US) residential buildings from 2000 to 2060 by combining the end-use emission model with the decomposing structural decomposition (DSD) method and Monte Carlo simulation. The results show that from 2001 to 2020 China decarbonized 1544 mega-tons of carbon dioxide (MtCO 2 ) and the US decarbonized 1848 MtCO 2 . In the business-as-usual scenario, China will hit its emission peak in 2031 (±3) with 934 (±61) MtCO 2 , while the US will maintain a lock-in level of 736 (±133) MtCO 2 since the 2030s. In the decarbonization scenario, operational carbon neutrality for residential buildings in 2060 is promoted by an increase in clean power generation proportion, building-integrated power generation level, building electrification level, and a reduction in end-use energy intensity, which will contribute 34.4 %, 21.4 %, 14.3 %, and 29.9 % in China and 32.9 %, 33.1 %, 8.2 %, and 25.8 % in the US, respectively. Especially, building-integrated power generation in China only costs about 40 % of what it costs in the US. Besides, high-decarbonization strategies for residential building operations are proposed as references for governments to formulate targeted climate policies. Overall, this study offers data benchmarks for buildings’ carbon neutrality of top economies to further promote synergistic carbon neutrality with the buildings of emerging economies in the age of Post COP27.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Technical Reference Documentation (V.3.3.0)

ResStock™ is the best-in-class building stock energy model for simulating and publishing energy use, utility bills, and greenhouse gas emissions from the residential sector of the U.S. ResStock answers two primary questions: (1) How is energy used in the U.S. residential building stock? and (2) What is the timeseries aggregate impact of energy technologies? Specifically, ResStock quantifies energy use across geographical locations, demographic groups, building types, fuels, end uses, and time of day. Additionally, it details the impact of efficiency or electrification measures: total changes in the amount of energy used by measure; where or in what use cases efficiency or electrification upgrade measures save energy; when or at what times of day savings occur; and which building stock or demographic segments have the biggest savings potential. This model, and the datasets it produces, are foundational to identifying pathways to affordable and equitable decarbonization of the U.S. residential buildings sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗