SEARCH · Engineering Papers

Results for “refrigerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Condensation heat transfer and pressure drop of low-global warming potential refrigerants in smooth aluminum tubes

In this work we report condensation heat transfer coefficient and pressure drop data for R-454B, R-32, and R-454C. These refrigerants are low Global Warming Potential (GWP) replacements for R-410A. We obtained these data in a smooth 7.2 mm outer diameter (5.94 mm inner diameter) aluminum tube. In these experiments, the key variables were condensation temperature (35 °C ≤ T cond ≤ 50 °C) and refrigerant mass flux (151.1 ≤ G ≤ 347.3 kg m –2 s –1 ). In general, for similar nominal operating conditions, we measured the highest heat transfer coefficients for R-32 and the lowest for R-454C. Among the correlations we used to predict the heat transfer data for all three refrigerants, the one developed by Thome et al. (2003) predicted the data with the greatest accuracy. Deviations between experimental data and predictions of this correlation were 21.7% for R-454B (with SBG correction), 22.0% for R-32, and 18.8% for R-454C (with SBG correction). Experimental pressure gradient data were predicted by the Friedel correlation Friedel (1979) with deviations of 13.8% for R-454B, 9.8% for R-32, and 10.2% for R-454C. In this work, we also compare the predictions of the Cavallini et al. correlation Cavallini et al. (2006) for R-454B and R-32 in smooth copper versus smooth aluminum tubes. To improve this correlation’s predictive capability for aluminum tubes, we have proposed some modifications. After incorporating these modifications, the deviations between the correlation’s predictions and our data were 10% for R-454B (with SBG correction), 8.1% for R-32, and 5.2% for R-454C (with SBG correction). Furthermore, these data and findings will assist the HVAC and refrigeration industry to implement low-GWP refrigerants in condensers using smooth aluminum tubes.

Aluminum tube↗

Evaluation and optimization of flow boiling frictional pressure drop correlations using the data from traditional and next-generation refrigerants in a micro-fin tube

This study presents an experimental evaluation and optimization of flow boiling frictional pressure drop correlations for conventional and next-generation refrigerants in a horizontal micro-fin tube, with particular emphasis on the newly emerging refrigerant blends R-454C and R-455A, for which pressure-drop data in enhanced tubes remain limited. Experiments were conducted with R-410A, R-454C, R-455A, R-134a, R-1234yf, and R-1234ze(E) in a copper micro-fin tube with an inner diameter of 8.468 mm, over mass fluxes ranging from 100 to 300 kg/(m²·s) depending on the refrigerant, and evaporation temperatures of 7, 12, and 14 °C. Frictional pressure gradients were determined from measured total pressure drops after subtracting acceleration pressure drop, and the resulting database was used to assess four existing models: Kuo and Wang (1996), Cavallini et al. (1997), Goto et al. (2001), and Diani et al. (2014). The measured frictional pressure gradient increased with vapor quality and mass flux for all refrigerants and increased further at lower evaporation temperatures, with the overall trend strongly related to liquid viscosity. Among the four correlations, the Goto et al. (2001) model provided the best overall agreement with the measured data before optimization. To further improve prediction accuracy, the Kuo and Wang (1996) and Goto et al. (2001) models were optimized using the complete experimental database. After optimization, both models reduced the overall mean absolute deviation to below 15%, while the optimized Goto et al. (2001) model maintained the best and most consistent overall performance. The results provide new pressure-drop data for next-generation refrigerants and demonstrate that parameter optimization can significantly enhance the applicability of existing micro-fin-tube correlations.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

International review of market trends, technologies and policies for commercial refrigeration equipment and implications for China

This report reviews the latest global and China-specific market trends as well as latest technology and policy trends related to commercial refrigeration equipment, with emphasis on refrigerated display cabinets. Section 2 reviews the global and China market trends for commercial refrigeration equipment. Section 3 presents the latest technology options for improving energy performance and compares global Best Available Technologies (BAT) to regional and China-specific baselines, and discusses low-GWP refrigerant options for commercial refrigeration equipment. Section 4 reviews global energy efficiency standards and labeling programs, and compares international efficiency standard requirements with China’s proposed and existing standard requirements. Section 5 ends with a review of key findings and conclusions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Quantum Computing – Real-Time Data Processing from a Dilution Refrigerator

This poster presents a real-time data visualization system for monitoring and displaying data from a Bluefors control unit connected to a dilution refrigerator. The goal is to provide an aesthetically pleasing and user-friendly web-based interface that continuously updates and displays critical data such as temperature and flow rates at various points within the refrigerator. Leveraging WebSocket technology, the system establishes multiple connections to the dilution refrigerators, enabling simultaneous monitoring of several units. The interactive webpage dynamically updates the data, providing researchers and operators with instant insights into the system's performance. The system's ability to stream and visualize data in real-time enhances the understanding of the dilution refrigerator's behavior, aiding in optimizing its operation and ensuring efficient scientific experiments. The application's web-based nature makes it easily accessible from any device with internet connectivity, promoting seamless collaboration and remote monitoring capabilities. Overall, this poster offers a comprehensive solution for real-time data visualization and analysis of dilution refrigerators, catering to the needs of researchers and scientists working in low-temperature physics and quantum computing fields.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Solid State Quantum Refrigeration Superconducting, Absorption and Measurement Based (Final Technical Report)

During this DOE grant, DE-SC0017890, in place for the past six years, all proposed research was carried out and published in peer-reviewed papers, as well as other projects that emerged during the research. In that effort the research team accomplished all proposed research, as well as many closely related research projects discovered and conceived of during the grant. These works included “Efficient Quantum Measurement Engines”, a work published in Physical Review Letters, giving a theory of quantum measurement-based engines, which uses quantum measurement as a resource. These engines are designed to efficiently convert energy from the stochastic quantum measurement process into useful work. Further publications include “Experimental Realization of a Quantum Dot Energy Harvester”, a joint theory and experimental work in collaboration with the group of Charles Smith in Cambridge, UK, as well as long time theoretical collaborators, Rafael Sánchez and Björn Sothmann. This work, featured as an Editor’s Suggestion in Physical Review Letters, realized an earlier theoretical proposal of ours, whereby two resonant tunneling quantum dots are connected to a central electronic cavity that is heated by a hot energy source. We also published “Superconducting Quantum Refrigerator: Breaking and Rejoining Cooper Pairs with Magnetic Field Cycles” a work done in collaboration with experimentalist Francesco Giazotto from ENS Pisa, Italy, which also resulted in a patent. This paper, published in Phys. Rev. Applied, advanced the concept of a cyclic fridge based on the normal/superconducting phase transition together with layered materials separated by tunnel junctions. We also completed the proposed research on a heat transistor, publishing “Thermal transistor and thermometer based on Coulomb-coupled conductors”, carried out as a collaboration between my group and theorists Splettstoesser (Lund U., Sweden), Sothmann (U. Duisburg-Essen, Germany), and Sánchez (U. Autónoma de Madrid, Spain). We carried out an analysis of a quantum coupled to a quantum point contact as a sensitive thermometer and heat transistor. We found the optimal statistical estimator for the temperature and compared it with experiments on the same type of devices. We also investigated autonomous quantum absorption refrigerators using quantum dots to cool by using a very hot thermal reservoir to drive heat between two other reservoirs. In the article “Quantifying the quantum heat contribution from a driven superconducting circuit”, we demonstrated that for a driven superconducting circuit, we showed heat flow provided by a hot source to the qubit can be switched on and off by varying external parameters, the frequency and the intensity of the driving. In the work “Stochastic thermodynamic cycles of a mesoscopic thermoelectric engine”, we reconsidered the autonomous thermoelectric heat engine in terms of underlying cycles. Rather than periodic behavior, the cycles were stochastic in nature. Nevertheless, by undertaking a graph theoretical analysis of the elementary transport processed, great quantitative and qualitative insight could be found. We also considered the quantum measurement process and showed that a quantum version of Maxwell’s demon could be related to the work extraction of a quantum system, closely related to arrow-of-time measures for quantum measurement, as described in our article “Thermodynamics of quantum measurement and Maxwell's demon's arrow of time”. This work was selected in Phys. Rev. A as an Editor’s Suggestion. A recent preprint titled “Cyclic Superconducting Quantum Refrigerators Using Guided Fluxon Propagation” accomplished an important piece of this grant: to propose a new kind of quantum refrigerator using the dynamics of fluxons in a type II superconductor. This invention envisioned a race-track type geometry where fluxons are confined. By applying a gradient of magnetic field together with electric current in a Corbino geometry, the circulating fluxons can actively cool a cold reservoir, realizing a new type of cyclic superconducting refrigerator. We also investigated the possibility of thermal control from different points of view. The application of quantum measurement to the system gives a new kind of control on the system of interest – we have pioneered this approach and shown that measurement can boost the thermal power of quantum engines as described in “Continuous measurement boosted adiabatic quantum thermal machines”. The ability to have heat flows on demand is an outstanding challenge, and we have provided new solutions to this problem in Thermal control across a chain of electronic nanocavities” for a chain of electron cavities using gating voltage control. The control methods using qubit/qubit coupling to create absorption fridges at their most fundamental level have also been developed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Charge Reduction and Performance Analysis of a Heat Pump Water Heater Using R290 as a Refrigerant—A Field Study

Heat pump water heaters (HPWHs) are a proven technology for water heating that has been commercialized. The adoption of HPWHs for domestic and commercial water heating is growing rapidly because of their superior performance compared with alternative water heating methods. Whereas most existing systems use R-134a as a working refrigerant, R290 has gained major attention owing to its superior thermodynamic properties. The goal of the current study is to assess the performance of residential HPWH with R290 as a direct refrigerant replacement for R134a. Two units of a 50 gal HPWH were used in this experimental study. A baseline unit contained R134a refrigerant, and a prototype unit contained R290 refrigerant. The prototype unit was developed through the modification of a commercially available HPWH unit to achieve a low charge of R290 refrigerant. Another major modification was the replacement of the baseline compressor with a compressor designed for R290. Tests were conducted in a field environment (a research and demonstration house) using programmed drawn profiles daily. The prototype that reduced the charge by 43–47% provided displayed performance comparable to the baseline unit regarding first-hour rating (FHR) and the uniform energy factor (UEF).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Leak Detection Technologies for Low Global Warming Potential (GWP), Flammable Refrigerants

Current commercial refrigeration systems use refrigerants with global warming potential (GWP) values ranging from 1250 to 4000. The emergence of low GWP alternatives (GWP <150) is expected to significantly reduce direct emissions in this sector, playing a crucial role in the ongoing electrification and decarbonization initiatives. However, many of these low GWP alternatives pose a flammability risk, necessitating robust sensing solutions to ensure the reliable and safe operation of the equipment. This paper examines various sensing mechanisms suitable for potential applications in systems that employ flammable refrigerants, specifically those designated as A2L class. It provides a summary of A2L refrigerants and their properties, followed by a comprehensive review of sensor classes, covering their working principles, features, advantages, and limitations. Additionally, the article delves into key performance characteristics such as accuracy, selectivity, sensitivity, dynamic characteristics, and durability, among other properties. The article discusses areas for improvement and suggests corresponding approaches for potential sensors in facilitating the successful adoption of flammable refrigerants. Finally, this paper presents the latest findings from experimental evaluation of 5 different sensing principles in detecting the composition variation as a result of various operational conditions. Reliability and sensitivity of the sensor in responding to shifts in true composition and the resultant LFL value is also discussed.

Reshniak, Viktor↗

Optimizing flow condensation models for next-generation refrigerants in axial micro-fin aluminum tubes

To support the transition to next-generation refrigerants, accurate modelling of heat transfer and pressure drop is essential for designing efficient heat exchangers. Current models, largely based on traditional refrigerants and unexpanded micro-fin tubes, may not reliably predict performance for new refrigerants and expanded micro-fin geometries. This study evaluates four condensation models using experimental data for six A2L refrigerants: R-32, R-454B, R-454C, R-455A, R-1234yf, and R-1234ze(E). For heat transfer models, the Han and Lee (2005) model initially yields the best accuracy (mean absolute Deviation, MAD = 22.1%). To further improve predictions, a correction factor reduces the Cavallini et al. (2009) model’s MAD from 68.2% to 15.4%, while optimization of the Kedzierski and Goncalves (1997) model achieves a MAD of 13.1%. For pressure drop, the Cavallini et al. (1997) model proves most accurate (MAD = 6.4%), with the simpler Haraguchi et al. (1993) model also effective (MAD = 9.4%). Keywords: Flow condensation models, heat transfer coefficient, frictional pressure drop, next-generation refrigerants, aluminum micro-fin tubes

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Modeling and Energy Analysis of Refrigeration Systems in Supermarkets: A Case Study

Refrigeration systems are the single largest consumer of electricity in supermarkets, accounting for approximately 40–60% of total store electricity use. As supermarkets face increasing pressures to improve efficiency and reduce operational costs, understanding the energy performance of refrigeration systems in supermarkets has become essential. In this paper, we investigate the energy performance and patterns of the refrigeration system using field measurements in one supermarket. The compressor coefficient of performance (COP) averaged 4.5 during nighttime steady-state operation, providing a practical efficiency benchmark. We develop simple physical-based load models for the display cases in the supermarket, where the refrigeration system uses R404A. The results show the display case models achieve a good agreement with measured data, validating its utility for energy estimation during unoccupied hours. Finally, the analysis reveals several challenges of data collection systems for refrigeration systems in the supermarket industry as well.

Chen, Yimin [ORNL] (ORCID:0000000338181655)↗

Grey-box Fault Models and Applications for Low Carbon Emission CO2 Refrigeration System

CO2 refrigeration systems have attracted more attentions in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in certain commercial buildings such as supermarkets. However, very limited energy studies have been done for such refrigeration systems under faults. Furthermore, this study investigated five common faults for supermarket transcritical CO2 refrigeration systems with display cases. The following major tasks were implemented for this study. (1) Five fault models (gray-box format) regarding the power consumption and supply air temperature were proposed for low- and high-temperature display cases, respectively. The models cover: ice accumulation on evaporator coil, evaporator fan partial failure, expansion valve failure, display door open, and condenser blockage. (2) These fault models were calibrated with field tests, and the modeling accuracies were in good agreement with measurement datasets. (3) The proposed fault models demonstrated more than 90% of fault detection for Fault Detection and Diagnostics (FDD) purposes for both field measurement and simulated data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A study on computational fluid dynamics modeling of a refrigerated container for COVID-19 vaccine distribution with experimental validation

A key issue with the distribution of vaccines to prevent COVID-19 is the temperature level required during transport, storage, and distribution. Typical refrigerated transport containers can provide a temperature-controlled environment down to -30 °C. However, the Pfizer vaccine must be carefully transported and stored under a lower temperature between -80 °C and -60 °C. One way to provide the required temperature is to pack the vaccine vials into small packages containing dry ice. Dry ice sublimates from a solid to a gas, which limits the allowable transport duration. This can be mitigated by transporting in a -30 °C refrigerated container. Moreover, because the dry ice will sublimate and thereby release CO 2 gas into the transport container, monitoring the CO 2 concentration within the refrigerated container is also essential. In the present work, a 3D computational fluid dynamics model was developed based on a commercially available refrigerated container and validated with experimental data. The airflow, temperature distribution, and CO 2 concentration within the container were obtained from the simulations. The modeling results can provide guidance on preparing experimental setups, thus saving time and lowering cost, and also provide insight into safety precautions needed to avoid hazardous conditions associated with the release of CO 2 during vaccine distribution.

59 BASIC BIOLOGICAL SCIENCES↗

Flow condensation heat transfer performance of natural and emerging synthetic refrigerants

There is great interest in predicting flow condensation heat transfer for lower global warming potential (GWP) fluids. This paper analyzes the efficacy of common flow condensation correlations developed for particular fluids in order to identify their suitability to predict heat transfer performance of low GWP fluids. Condensation heat transfer data were extracted from the literature, including 19 papers and 1,473 data points for natural refrigerants [i.e., ammonia (R717), CO 2 (R744), propane (R290), isobutane (R600a)] and 35 papers and 5,030 data points for synthetic refrigerants [i.e., R12, R1234yf, R1234ze(E), R1234ze(Z), R22, R32, R41, R123, R125, R134a, R142b, R152a, R161, R404A, R410A, R448A, R449A, R450A, R452B, R454C, R455A, R513A] encompassing tube diameters of 0.1–11.5 mm, mass fluxes of 55–1200 kg/m2s, and saturation temperatures of -25°C–65°C. Correlations analyzed included Akers et al. (1959), Cavallini et al. (2006, 2011), Kim and Mudawar (2013), Macdonald and Garimella (2016), Shah (1979, 2009, 2013, 2016) and Traviss et al. (1973) for smooth tubes and Chamra et al. (2005) and Kedzierski and Goncalves (1999) for enhanced tubes. Since most studies did not report wall temperature, correlations which relied on wall temperature directly or indirectly were excluded from the analysis. For synthetic refrigerants, mean average error (MAE) ranged from 6%–257%, and Cavallini et al. (2011) and Kim and Mudawar (2013) were the best predictors for emerging synthetic refrigerants. Furthermore, the Kim and Mudawar (2013) correlation was found to best predict the heat transfer performance for propane and R600a data, but most correlations did not accurately predict ammonia and CO 2 flow condensation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic model-based feature extraction for fault detection and diagnosis of a supermarket refrigeration system

With the increasing concerns over climate change and carbon emissions, fault detection and diagnostics (FDD) of low–global warming potential (GWP) refrigerant supermarket refrigeration systems has gained great attention from academic and industrial sectors. Various FDD approaches have been developed to detect, identify, and diagnose faults to save energy, improve food quality, and protect the environment. Here, to mitigate the difficulty of collecting high-quality steady-state operational data in field operations faced by most model-based FDD methods, this study developed dynamic models of a low–GWP refrigerant (CO 2 ) supermarket refrigeration system. The model accuracy was validated using manufacturer data and experimental data. Simulations were conducted to predict the system dynamic response under two common operational faults—evaporator air path blockage fault and the display case door open fault—to identify fault patterns and define key dynamic behavior indexes for supporting FDD algorithm development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficient Refrigerated Display Cases - Can They Flex Their Power? Preprint

Refrigerated display cases are widely-used, critical equipment in supermarkets for maintaining product safety and quality. Energy-efficient medium temperature liquid-cooled refrigerated display cases can save 25-70% of the total supermarket energy, according to manufacturers. Traditionally, cases operate by maintaining a temperature around a user-input setpoint that is dependent on the product in the case. Although cases are major electrical energy consumers, they are hardly ever considered for implementing load-flexibility strategies. With added load-flexibility capabilities, refrigerated display cases can shed (reduce), or shift (by adding and subsequently shedding) load. Supermarkets can reduce their energy costs and enhance electric grid integrity by implementing these smart load-flexibility control strategies. Advanced controls can also enable load-shifting to coincide with optimum periods of renewable energy generation. This will further improve operational costs and reduce greenhouse gas emissions without compromising food safety and quality. In this research, we have evaluated the energy savings of liquid-cooled medium temperature display cases and developed load flexibility strategies leveraging an advanced controls system, a variable speed compressor, and heat rejection via a water-cooled condenser. This study further assessed the impact of load flexibility strategies in a controlled environment chamber for a single refrigerated display case.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Toward a life cycle approach for classifying the toxicity of refrigerants

Refrigeration and air conditioning currently account for ~20% of the total electricity consumption in buildings around the world (IEA, 2018). Over the next three decades, as global temperatures are projected to increase, urbanization and economic growth will lead to an increased demand for refrigeration and cooling. While technological advances have led to increased cooling capacity and safer refrigerants over the years, emissions from refrigeration systems can affect the environment by contributing to greenhouse gas emissions or by depleting the ozone layer, depending on the gas emitted. Further, because of ongoing and pending policy and regulatory changes to avert ozone depletion and global climate change, there is an increasing focus on adopting compounds that are efficient at cooling while also reducing emissions and other adverse environmental impacts.

54 ENVIRONMENTAL SCIENCES↗

Virtual refrigerant charge sensing algorithm for residential CO₂ heat pumps

Natural refrigerants are increasingly adopted in next-generation heat pump systems, among which CO₂ heat pumps have attracted significant attention. However, due to their high operating pressures, the leakage risk is higher, resulting in undercharge conditions and degraded heat pump performance. Thus, developing an accurate refrigerant charge level detection technique is necessary to guarantee safe and efficient operation. Although virtual refrigerant charge (VRC) level calculation algorithms for CO₂ heat pumps exist, they typically rely on empirically selected features without a systematic selection framework, leading to multicollinearity and potential overfitting, which limit their prediction accuracy and generalizability. To address these issues, this study proposes a VRC algorithm framework with a systematic feature selection method that identifies physically meaningful and statistically significant features, and is applied using a residential CO₂ heat pump as a case study. The method is extended from previous work on conventional refrigerants to account for charge behavior in CO₂ gas coolers. The selected features include gas cooler outlet density, evaporator pressure, and superheat temperature. The results demonstrate that the proposed feature selection method significantly improves prediction accuracy compared to existing VRC approaches. A relatively small training dataset (∼30 samples) is sufficient for feature identification and model development. The developed algorithm achieves less than 3% prediction error under both undercharge and overcharge conditions, representing reductions of 46.7% and 35.3% compared to two recent reference VRC algorithms for transcritical CO₂ heat pumps reported in the literature. The proposed algorithm and feature selection method enhance leakage detection capability, facilitate the deployment of CO₂ heat pump systems, and contribute to reduced energy waste and maintenance costs.

Guo, Fangzhou [Lawrence Berkeley National Laborato↗

A 1-km photonic link connecting superconducting circuits in two dilution refrigerators

Superconducting quantum processors are a leading platform for implementing practical quantum computation algorithms. Although superconducting quantum processors with hundreds of qubits have been demonstrated, their further scale-up is constrained by the physical size and cooling power of dilution refrigerators. This constraint can be overcome by constructing a quantum network to interconnect qubits hosted in different refrigerators, which requires microwave-to-optical transducers to enable low-loss signal transmission over long distances. Although various designs and demonstrations have achieved high-efficiency and low-added-noise transducers, a coherent photonic link between separate refrigerators has not yet been realized. Here, in this work, we experimentally demonstrate coherent signal transfer between two superconducting circuits housed in separate dilution refrigerators, enabled by a pair of frequency-matched aluminium nitride electro-optic transducers connected via a 1-km telecom optical fibre. The optical frequency matching between two transducers is realized by an asymmetric photonic molecule design, and an overall 80 dB improvement in transduction efficiency over commercial electro-optic modulators is achieved, paving the way towards a fully quantum-enabled link. This work provides critical design guidelines for scalable superconducting quantum networks interconnected by photonic links.

nonlinear optics↗

Cyclic superconducting refrigerators using guided fluxon propagation

We propose cyclic refrigeration in solid state, employing a gas of magnetic field vortices in a type-II superconductor—also known as fluxons—as the cooling agent. Refrigeration cycles are realized by envisioning a racetrack geometry consisting of both adiabatic and isothermal arms, etched into a type-II superconductor. The guided propagation of fluxons in the racetrack is achieved by applying an external electrical current, in a Corbino geometry, through the sample. A gradient of magnetic field is set across the racetrack allowing one to adiabatically cool down and heat up the fluxons, which subsequently exchange heat with the cold and hot reservoirs, respectively. We characterize the steady state of refrigeration cycles thermodynamically for both s -wave and d -wave pairing symmetries, and present their figures of merit such as the cooling power delivered, and the coefficient of performance. Our cooling principle can offer significant cooling for on-chip microrefrigeration purposes, by locally cooling below the base temperatures achievable in a conventional dilution refrigerator. We estimate n W / m m 2 of cooling power per unit area assuming a tunnel coupling with ∼ M Ω µ m 2 specific resistance. Integrating the fluxon fridge to quantum circuits can enhance their coherence time by locally suppressing thermal fluctuations, and improve the efficiency of single photon detectors and charge sensors. Published by the American Physical Society 2024