Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “readout systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Assembly and Integration Process of the High-Density Detector Array Readout Modules for the Simons Observatory

The Simons Observatory will measure the cosmic microwave background tempera-ture and polarization using a suite of new telescopes in the Atacama Desert in Chile. The Simons Observatory will use dichroic transition edge sensor (TES) bolometer arrays spanning six frequency bands from 27 to 280 GHz. The Simons Observa-tory will pioneer the use of a densely packed multiplexing architecture based on the microwave SQUID multiplexer ( 𝜇mux), housing ∼2000 microwave resonators, each coupled to a TES. The Simons Observatory aims to multiplex each array of ∼2000 detectors with a single pair of coaxial cables and requires a multiplexing factor of ∼1000 . The Simons Observatory cryogenic readout system is called the universal microwave multiplexing module (UMM). The UMM couples to both horn and lenslet-coupled detector arrays and is integrated into the universal focal-plane module (UFM) after being independently characterized. We present processes we have developed for highly repeatable and automated integration methods of UMMs, which will be needed for the production of the 49 UFMs required for the first stage of the Simons Observatory.

CMB↗

Pulsed-laser ranging

Pulsed rubidium laser range measurements with delayed sweep oscilloscope, and with digital readout system

RUBY LASER↗

Electronic calorimetric computer

Electronic calorimetric computer calculates nuclear reactor thermal power output to a nominal accuracy of 1 percent. Heat balance is determined by an electronic approach. The thermal power is calculated using the inlet and outlet temperatures and the volume of cooling water and is displayed by a digital readout system.

Heckelman, J. D.↗

Ground testing the Apollo vehicle.

Static structure ground test for Saturn-Apollo vehicle short stack, describing air pressure simulation, data acquisition and readout systems

Reese, D. R.↗

Multiwire proportional counter development

A test run was made at the Bevatron to check the character of signals induced in an electromagnetic delay line capacitively coupled to the wire cathode plane of a multiwire proportional chamber. In particular, these signals and the behavior of the readout electronics as a function of associated delta-ray production are studied. These measurements are important in assessing the effect of delta-ray background on the spatial resolution attainable for the primary ions. Test results are used to design a multiwire proportional chamber and readout system for use as spatial detectors in a superconducting magnetic spectrometer experiment.

Source record↗

Two-dimensional photon-counting detector arrays based on microchannel array plates

The production of simple and rugged photon-counting detector arrays has been made possible by recent improvements in the performance of the microchannel array plate (MCP) and by the parallel development of compatible electronic readout systems. The construction of proximity-focused MCP arrays of novel design in which photometric information from (n x m) picture elements is read out with a total of (n + m) amplifier and discriminator circuits is described. Results obtained with a breadboard (32 x 32)-element array employing 64 charge-sensitive amplifiers are presented, and the application of systems of this type in spectrometers and cameras for use with ground-based telescopes and on orbiting spacecraft discussed.

Timothy, J. G.↗

Quadrant anode image sensor

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, about 10 microns, allows individual MCP channels to be distinguished.

Lampton, M.↗

To perform a gyro test of general relativity in a satellite and develop associated control technology

A satellite configuration having two gyroscopes with axes parallel to the boresight of a telescope and two at right angles to the telescope and approximately parallel and perpendicular to the earth's axis is proposed for measuring geodetic precessions due to the earth's motion about the sun, higher order geodetic terms calculated from the earth's quadrapole mass moment (0.010 arc-sec/year in a 400 nautical mile polar orbit), and deflection by the sun of the starlight signal for the reference telescope. Data from the experiment also contain large periodic signals due to the annual and orbital aberrations of starlight which are useful in providing a built in reference signal of known amplitude for scaling the relativity signals, and should yield a singularly precise measurement of the parallax of the reference star. The development of the gyroscope and its readout system are discussed, as well as signal integration, drag-free control, and attitude control.

Fairbank, W. M.↗

Rebirth of remote sensing: Do we know enough for our own good?

Obstacles or deficiencies in on-going satellites that impede operational use of data are described. Because spectral and spatial characteristics of LANDSAT D sensors are different from earlier satellites, they deter operational planning and data use, and an operational program operated in parallel with experimental technology development is needed. Particular attention is given to the satellite sensor readout system, its current applications, and needs for the future.

Herbst, R. L.↗

Phase-locked tracking loops for LORAN-C

Portable battery operated LORAN-C receivers were fabricated to evaluate simple envelope detector methods with hybrid analog to digital phase locked loop sensor processors. The receivers are used to evaluate LORAN-C in general aviation applications. Complete circuit details are given for the experimental sensor and readout system.

Burhans, R. W.↗

Air pressure measurement

The pressure measurement was made by a Model 830J Rosemont sensor which utilized the principle of a changing pressure to change correspondingly the capacitance of the pressure sensitive element. The sensor's range was stated to be from zero to 100 Torr (14 km); however, the sensor was not activated until an altitude of 20 km (41 Torr) was reached during the balloon ascent. The resolution of the sensor was specified by the manufacturer as infinitesimal; however, associated electronic and pressure readout systems limit the resolution to .044 Torr. Thus in the vicinity of an altitude of 30 km the pressure resolution corresponded to an altitude resolution of approximately 33 meters.

Ballard, H. N.↗

Measurement of Three-dimensional Density Distributions by Holographic Interferometry and Computer Tomography

The use of holographic interferometry to measure two and threedimensional flows and the interpretation of multiple-view interferograms with computer tomography are discussed. Computational techniques developed for tomography are reviewed. Current research topics are outlined including the development of an automated fringe readout system, optimum reconstruction procedures for when an opaque test model is present in the field, and interferometry and tomography with strongly refracting fields and shocks.

Vest, C. M.↗

SQUID readout and ultra-low magnetic fields for Gravity Probe-B (GP-B)

The superconducting readout system to be used for resolving 0.001 arcsec changes in the gyroscope spin direction in the Relativity Gyroscope (GP-B) experiment is described. This system couples the London magnetic moment flux of the spinning gyro to a low noise superconducting quantum interference device (SQUID) detector. Resolution limits and noise performance of the detection system are discussed, and improvements obtained and expected with advanced SQUIDs are presented. Also described is the novel use of superconducting magnetic shielding techniques to obtain a 250 dB attenuation of the earth's magnetic field at the location of the gyroscopes. In this approach, expanded superconducting foil shields are coupled with fixed cylindrical superconducting shields and special geometric considerations to obtain the extremely high attenuation factor required. With these shielding techniques, it appears that the 0.5-Gauss earth field (which appears to the gyroscopes as an ac field at the satellite roll rate) can be reduced to the 10 to the -13th G level required by the experiment. Recent results concerning improvements in the performance of the superconducting foil techniques obtained with the use of a new computer-controlled cooling system are presented.

Lockhart, James M.↗

High-spatial resolution and high-spectral resolution detector for use in the measurement of solar flare hard X-rays

In the areas of high spatial resolution, the evaluation of a hard X-ray detector with 65 micron spatial resolution for operation in the energy range from 30 to 400 keV is proposed. The basic detector is a thick large-area scintillator faceplate, composed of a matrix of high-density scintillating glass fibers, attached to a proximity type image intensifier tube with a resistive-anode digital readout system. Such a detector, combined with a coded-aperture mask, would be ideal for use as a modest-sized hard X-ray imaging instrument up to X-ray energies as high as several hundred keV. As an integral part of this study it was also proposed that several techniques be critically evaluated for X-ray image coding which could be used with this detector. In the area of high spectral resolution, it is proposed to evaluate two different types of detectors for use as X-ray spectrometers for solar flares: planar silicon detectors and high-purity germanium detectors (HPGe). Instruments utilizing these high-spatial-resolution detectors for hard X-ray imaging measurements from 30 to 400 keV and high-spectral-resolution detectors for measurements over a similar energy range would be ideally suited for making crucial solar flare observations during the upcoming maximum in the solar cycle.

Desai, U. D.↗

ORFEUS focal plane instrumentation: The Berkeley spectrometer

A spectrograph for the ORFEUS mission that incorporates four varied line-space, spherically figured diffraction gratings was designed. The ORFEUS, a 1-m normal incidence telescope is equipped with 2 focal plane spectrographs. The Berkeley spectrograph was developed with an optimizing raytracing computer code. Each grating accepts the light from 20 percent of the aperture of the telescope primary mirror and has a unique set of characteristics to cover a sub-bandpass within the 390 to 1200 A spectral range. Two photon-counting detectors incorporating a time delay readout system are used to record the spectra from all four gratings simultaneously. The nominal design achieves a spectral resolution (FWHM) in excess of 5500 at all wavelengths within the bandpass. The resolution is limited primarily by the detector spatial resolution. The 1 sigma astigmatism of this design varies between 13 and 150 micrometer on the same focal surface. An independent, direct imaging system tracks the drift of the target within the spectrometer aperture and allows measurement of the misalignment between the telescope optical axis and that of the external star tracker. The resolution and astigmatism achievable with this design are superior to those of a standard Rowland spectrograph designed with the same constraints.

Hurwitz, Mark↗

Digital optical spark chambers

The authors constructed and tested a prototype digital readout system for optical spark chambers using a linear, solid-state charge-coupled-device detector array. Position resolution of 0.013 mm (sigma) over a 25-cm field of view has been demonstrated. It is concluded that this technique should permit the construction of economical, lightweight and low-power trajectory hodoscopes for use in cosmic-ray instrumentation on balloons and in spacecraft.

Evenson, Paul↗

Planar double delay-line readout technique for microchannel plate detectors

A two-dimensional position-sensitive electrical readout system for microchannel plate detectors in spectroscopic applications has been devised. Two adjacent parallel coplanar delay lines are used. The difference in time of arrival of the electron event signal between the ends of the delay lines gives one coordinate of the centroid of each event pulse. The ratio of the event amplitudes on the two delay lines gives the orthogonal coordinate by means of charge partitioning. The performance characteristics of operational double delay lines for systems of this type are presented.

Lampton, M.↗

The Berkeley EUV spectrometer for ORFEUS

A novel EUV spectrometer is presented for the ORFEUS-SPAS mission. It uses a set of four varied line-space spherical diffraction gratings to obtain high-resolution spectra of point sources at wavelengths between 390 and 1200 A. The spectra are recorded with two detector units, each containing curved-surface microchannel plates and a delay-line anode-readout system. An independent optical system detects the image of the source in the entrance aperture and tracks the source as it drifts during an observation, enabling a reconstruction of the spectra postflight. The overall system performance is discussed and illustrated by synthetic spectra.

Hurwitz, M.↗