Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rate design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Exploring the impact of increased solar deployment levels on residential electricity bills in India

Here, in this study, the impact of increased solar penetration in the electricity generation mix on residential electricity consumer bills is explored. The study comprises of two sections: simulation of wholesale electricity rates and retail rate modeling. In the first stage, wholesale prices were modeled using a bottom-up long term unit commitment optimization model for different energy mix scenarios based on increased solar penetration, ranging from 5 to 40% on energy basis. The simulations indicated a fall in wholesale prices with increased solar penetration, a result of merit order effect. The simulated wholesale prices were then used to model retail rates for residential consumers. Four different types of retail rates were designed: flat rate, real time pricing, time of use and critical peak pricing. The impact of these retail rate mechanisms on electricity bills of residential consumers was analyzed and it was found that the bill savings achieved from time varying rates are greater than for time invariant rates. With increased solar penetration, customers with time-varying rates are likely to benefit the most from electricity bill savings. Although consumers with flat rate gain bill savings with increased solar penetration, the savings are likely to be lower than with time-varying rates.

14 SOLAR ENERGY↗

On the Path to SunShot - Utility Regulatory Business Model Reforms forAddressing the Financial Impacts of Distributed Solar on Utilities

Net-energy metering (NEM) with volumetric retail electricity pricing has enabled rapid proliferation of distributed photovoltaics (DPV) in the United States. However, this transformation is raising concerns about the potential for higher electricity rates and cost-shifting to non-solar customers, reduced utility shareholder profitability, reduced utility earnings opportunities, and inefficient resource allocation. Although DPV deployment in most utility territories remains too low to produce significant impacts, these concerns have motivated real and proposed reforms to utility regulatory and business models, with profound implications for future DPV deployment. This report explores the challenges and opportunities associated with such reforms in the context of the U.S. Department of Energy’s SunShot Initiative. As such, the report focuses on a subset of a broader range of reforms underway in the electric utility sector. Drawing on original analysis and existing literature, we analyze the significance of DPV’s financial impacts on utilities and non-solar ratepayers under current NEM rules and rate designs, the projected effects of proposed NEM and rate reforms on DPV deployment, and alternative reforms that could address utility and ratepayer concerns while supporting continued DPV growth. We categorize reforms into one or more of four conceptual strategies. Understanding how specific reforms map onto these general strategies can help decision makers identify and prioritize options for addressing specific DPV concerns that balance stakeholder interests.

14 SOLAR ENERGY↗

Sensor for Measuring Hydrogen Partial Pressure in Parabolic Trough Power Plant Expansion Tanks

The National Renewable Energy Laboratory and Acciona Energy North America are working together to design and implement a process system that provides a permanent solution to the issue of hydrogen buildup at parabolic trough power plants. We are pursuing a method that selectively removes hydrogen from the expansion tanks that serve as reservoirs for the heat transfer fluid (HTF) that circulates in the collector field and power block components. Our modeling shows that removing hydrogen from the expansion tanks at a design rate reduces and maintains dissolved hydrogen in the circulating HTF to a selected target level. Our collaborative work consists of several tasks that are needed to advance this process concept to a development stage, where it is ready for implementation at a commercial power plant. Our main effort is to design and evaluate likely process-unit operations that remove hydrogen from the expansion tanks at a specified rate. Additionally, we designed and demonstrated a method and instrumentation to measure hydrogen partial pressure and concentration in the expansion-tank headspace gas. We measured hydrogen partial pressure in the headspace gas mixture using a palladium-alloy membrane, which is permeable exclusively to hydrogen. The membrane establishes a pure hydrogen gas phase that is in equilibrium with the hydrogen in the gas mixture. We designed and fabricated instrumentation, and demonstrated its effectiveness in measuring hydrogen partial pressures over a range of three orders of magnitude. Our goal is to install this instrument at the Nevada Solar One power plant and to demonstrate its effectiveness in measuring hydrogen levels in the expansion tanks under normal plant operating conditions.

14 SOLAR ENERGY↗

The effect of prefilter design on sample rate selection in digital flight control systems

The effect of prefilters on sample rate selection is examined and design procedures are determined for obtaining the best combination of prefilter breakpoint and sample rate. The employed approach involves a quantitative comparison of the output noise response of systems originating from the same basic plant and designed over a wide range of prefilters and sample rates. Each system design was carefully tailored so that it exhibited approximately identical responses to commands. The results presented augment the criteria for sample rate selection which have been discussed by Powell and Katz (1975). Attention is given to system characteristics, an integrator as a plant, and the short period motion of the F-8 aircraft.

Peled, U.↗

Advanced Rooftop Control (ARC) Retrofit: Field-Test Results

The multi-year research study was initiated to find solutions to improve packaged equipment operating efficiency in the field. Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) and Bonneville Power Administration (BPA) conducted this research, development and demonstration (RD&D) study. Packaged equipment with constant speed supply fans is designed to provide ventilation at the design rate at all times when the fan is operating as required by building code. Although there are a number of hours during the day when a building may not be fully occupied or the need for ventilation is lower than designed, the ventilation rate cannot be adjusted easily with a constant speed fan. Therefore, modulating the supply fan in conjunction with demand controlled ventilation (DCV) will not only reduce the coil energy but also reduce the fan energy. The objective of this multi-year research, development and demonstration project was to determine the magnitude of energy savings achievable by retrofitting existing packaged rooftop air conditioners with advanced control strategies not ordinarily used for packaged units. First, through detailed simulation analysis, it was shown that significant energy (between 24% and 35%) and cost savings (38%) from fan, cooling and heating energy consumption could be realized when packaged air conditioning units with gas furnaces are retrofitted with advanced control packages (combining multi-speed fan control, integrated economizer controls and DCV). The simulation analysis also showed significant savings for heat pumps (between 20% and 60%). The simulation analysis was followed by an extensive field test of a retrofittable advanced rooftop unit (RTU) controller.

Katipamula, Srinivas↗

Large-scale scenarios of electric vehicle charging with a data-driven model of control

Transportation electrification is forecast to bring millions of new electric vehicles to roads worldwide this decade. Planning to support those vehicles depends on detailed scenarios of their electricity demand in both uncontrolled and controlled or smart charging scenarios. In this work, we present a novel modeling approach to enable rapid generation of demand estimates that represent the impact of controlled charging for large-scale scenarios with millions of individual drivers. To model the effect of load modulation control on aggregate charging profiles, we propose a novel machine learning approach that replaces traditional optimization approaches. We demonstrate its performance modeling workplace charging control under a range of electricity rate schedules, achieving small errors (2.5%–4.5%) while accelerating computations by more than 4000 times. To generate the uncontrolled charging demand for scenarios with residential, workplace, and public charging we use statistical representations of a large data set of real charging sessions. We demonstrate the methodology by generating diverse sets of scenarios for California's charging demand in 2030 which consider multiple charging segments and controls, each run locally in under 50 s. We further demonstrate support for rate design by modeling the large-scale impact of a new, custom rate schedule for workplace charging.

33 ADVANCED PROPULSION SYSTEMS↗

Laser Confocal Microscopy Uncertainty Quantification Study

At Los Alamos National Laboratory (LANL), the Storage Safety and Engineering (SSE) team completes annual surveillance on a subset of in-use interim nuclear material storage containers in fulfilment of requirements outlined in DOE Manual M 441.1-1. The containers are selected through several methods, such as subject matter expert judgement, random selection, and trending items. Following these selections, the SSE team has the capacity to complete surveillance on 15-20 containers each fiscal year, composed of a combination of SAVY-4000 and Hagan storage containers. Through previous work, the stainless-steel components of the containers have been identified as life limiting components, with an emphasis on the thin-walled bodies. The team is focused on understanding the extent of general and pitting corrosion, due to observations of extensive corrosion from stored contents and bag-out-bag degradation. Quantifying corrosion effects on the thin-walled stainless steel container bodies, and understanding potential impacts to the respective design release rates and design qualification release rates is paramount to the team. To date, destructive examination (DE) has proven to be the most insightful method for developing an understanding on the extent of corrosion on used containers. To standardize this process, the SSE team developed a destructive examination guide for analyzing stainless steel components of the containers. Corroded containers of interest are identified during surveillance activities and set aside for sectioning and characterization. Following sectioning, a major step in the DE workflow is the utilization of laser confocal microscopy for scanning corroded samples of interest and extracting data on pits, such as count, depth, and equivalent diameter. Adhering to the techniques outlined in the DE guide, analysis has been completed on two Hagans and one SAVY-4000 container, with the maximum pit depth recorded as 139.1 ± 22.82 μm on a 17.5 year old Hagan. The findings from the completed destructive examinations will be utilized to support lifetime extension efforts of the SAVY-4000 as the team can better estimate corrosion rates and effects over time based on stored contents and age. Due to the implications of observing extreme pit depths that approach the nominal container body thickness of .0299 inches (0.759 mm) or minimum container thickness of 0.236” (0.6 mm), high confidence in the LCM measurements is desired. Through testing outlined in, it was concluded that the total error ascribed to the 20x objective when conducting large image mapping on the Keyence VK-X3050 laser confocal microscope (LCM) relative to a 50x objective (reference) is 16.4% (± 8.73%). For shallow features on the order of pristine SAVY surface defects (i.e. 5 μm), this uncertainty is appropriate. However, this conservative estimate of total error poses a fundamental concern for pit depths that approach the thickness of the measured samples. That is, with the measurement uncertainty currently employed on all measurements, the LCM would be unable to resolve if a pit with a depth of 515 μm is through wall. Standard step height samples were procured and used in the present study to assess the resolution and repeatability of height measurements. Understanding the resolution and repeatability of height measurements was the first focus of the team as it relates directly to pit depth, which is of primary concern. Calibration gratings were procured to evaluate the resolution and repeatability of measurements in the X and Y axes of the LCM stage. The results of the depth uncertainty study were conducted first and presented in the subsequent sections. The planar uncertainty study is appended to the depth study with conclusions from both summarized at the end of the report.

36 MATERIALS SCIENCE↗

InSight Aerothermal Environment Assessment

The InSight spacecraft was proposed to be a build-to-print copy of the Phoenix vehicle due to the knowledge that the lander payload would be similar and the trajectory would be similar. However, the InSight aerothermal analysts, based on tests performed in CO2 during the Mars Science Laboratory mission (MSL) and completion of Russian databases, considered radiative heat flux to the aftbody from the wake for the first time for a US Mars mission. The combined convective and radiative heat flux was used to determine if the as-flown Phoenix thermal protection system (TPS) design would be sufficient for InSight. All analyses showed that the design would be adequate. Once the InSight lander was successfully delivered to Mars on November 26, 2018, work began to reconstruct the atmosphere and trajectory in order to evaluate the aerothermal environments that were actually encountered by the spacecraft and to compare them to the design environments.The best estimated trajectory (BET) reconstructed for the InSight atmospheric entry fell between the two trajectories considered for the design, when looking at the velocity versus altitude values. The maximum heat rate design trajectory (MHR) flew at a higher velocity and the maximum heat load design trajectory (MHL) flew at a lower velocity than the BET. For TPS sizing, the MHL trajectory drove the design. Reconstruction has shown that the BET flew for a shorter time than either of the design environments, hence total heat load on the vehicle should have been less than used in design. Utilizing the BET, both DPLR and LAURA were first run to analyze the convective heating on the vehicle with no angle of attack. Both codes were run with axisymmetric, laminar flow in radiative equilibrium and vibrational non-equilibrium with a surface emissivity of 0.8. Eight species Mitcheltree chemistry was assumed with CO2, CO, N2, O2, NO, C, N, and O. Both codes agreed within 1% on the forebody and had the expected differences on the aftbody. The NEQAIR and HARA codes were used to analyze the radiative heating on the vehicle using full spherical ray-tracing. The codes agreed within 5% on most aftbody points of interest.The LAURA code was then used to evaluate the conditions at angle of attack at the peak heating and peak pressure times. Boundary layer properties were investigated to confirm that the flow over the forebody was laminar for the flight.Comparisons of the aerothermal heating determined for the reconstructed trajectory to the design trajectories showed that the as-flown conditions were less severe than design

Beck, Robin↗

InSight's Reconstructed Aerothermal Environments

The InSight spacecraft was proposed to be a build-to-print copy of the Phoenix vehicle due to the knowledge that the lander payload would be similar and the trajectory would be similar. However, the InSight aerothermal analysts, based on tests performed in CO2 during the Mars Science Laboratory mission (MSL) and completion of Russian databases, considered radiative heat flux to the aftbody from the wake for the first time for a US Mars mission. The combined convective and radiative heat flux was used to determine if the as-flown Phoenix thermal protection system (TPS) design would be sufficient for InSight. All analyses showed that the design would be adequate. Once the InSight lander was successfully delivered to Mars on November 26, 2018, work began to reconstruct the atmosphere and trajectory in order to evaluate the aerothermal environments that were actually encountered by the spacecraft and to compare them to the design environments.The best estimated trajectory (BET) reconstructed for the InSight atmospheric entry fell between the two trajectories considered for the design, when looking at the velocity versus altitude values. The maximum heat rate design trajectory (MHR) flew at a higher velocity and the maximum heat load design trajectory (MHL) flew at a lower velocity than the BET. For TPS sizing, the MHL trajectory drove the design. Reconstruction has shown that the BET flew for a shorter time than either of the design environments, hence total heat load on the vehicle should have been less than used in design. Utilizing the BET, both DPLR and LAURA were first run to analyze the convective heating on the vehicle with no angle of attack. Both codes were run with axisymmetric, laminar flow in radiative equilibrium and vibrational non-equilibrium with a surface emissivity of 0.8. Eight species Mitcheltree chemistry was assumed with CO2, CO, N2, O2, NO, C, N, and O. Both codes agreed within 1% on the forebody and had the expected differences on the aftbody. The NEQAIR and HARA codes were used to analyze the radiative heating on the vehicle using full spherical ray-tracing. The codes agreed within 5% on most aftbody points of interest.The LAURA code was then used to evaluate the conditions at angle of attack at the peak heating and peak pressure times. Boundary layer properties were investigated to confirm that the flow over the forebody was laminar for the flight.Comparisons of the aerothermal heating determined for the reconstructed trajectory to the design trajectories showed that the as-flown conditions were less severe than design

radiation↗

Aeroacoustic Characterization of Optimum Hovering Rotors using Artificial Neural Networks

This work illustrates the use of artificial neural network modeling in the aerodynamic and aeroacoustic characterization of optimum hovering rotors over a broad range of design and operating conditions. Design of Experiments was used to create input feature spaces over eight input factors: the number of rotor blades, rotor radius, rotor rotation rate, design thrust condition, collective pitch, airfoil camber, the location of maximum camber, and the airfoil thickness. A low-fidelity tool chain was then used at the discrete data points defined by the designed input feature spaces to analytically design optimum hovering rotors and simulate aerodynamic and aeroacoustic quantities. This allowed for the generation of data sets over which to train and test the artificial neural network prediction models. Prediction models were trained over the data sets for the actual thrust generated by the rotor, power loading, tonal thickness and loading noise at the fundamental blade passage frequency, and broadband self-noise at seventeen one-third octave bands between 1 kHz and 40 kHz. These prediction models were validated by testing over data previously unseen by the models to quantify their capability for generalization to new data within the design feature space. The models were then used to study the effect each input feature had on the aeroacoustics and aerodynamics of optimum hovering rotors and physical insights were concluded to further explain the effect of each input. This characterization study showed that tonal noise and power loading were most sensitive to the number of rotor blades and the rotor rotation rate and that broadband noise was most sensitive to collective pitch and the design thrust condition.

Christopher S Thurman↗

Apparatus, components and operating methods for circulating fluidized bed transport gasifiers and reactors

The improvements proposed in this invention provide a reliable apparatus and method to gasify low rank coals in a class of pressurized circulating fluidized bed reactors termed "transport gasifier." The embodiments overcome a number of operability and reliability problems with existing gasifiers. The systems and methods address issues related to distribution of gasification agent without the use of internals, management of heat release to avoid any agglomeration and clinker formation, specific design of bends to withstand the highly erosive environment due to high solid particles circulation rates, design of a standpipe cyclone to withstand high temperature gasification environment, compact design of seal-leg that can handle high mass solids flux, design of nozzles that eliminate plugging, uniform aeration of large diameter Standpipe, oxidant injection at the cyclone exits to effectively modulate gasifier exit temperature and reduction in overall height of the gasifier with a modified non-mechanical valve.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of source coders and joint source/channel coders for noisy channels

A theory behind a proposed joint source/channel coding approach is developed and a variable rate design approach which provides substantial improvement over current joint source/channel coder designs is obtained. The Rice algorithm as applied to the output of the Gamma Ray Detector of the Mars Orbiter is evaluated. An alternative algorithm is obtained which outperforms the Rice both in terms of data compression and noisy channel performance. A high-fidelity low-rate image compression algorithm is developed which provides almost distortionless compression of high resolution images.

Sayood, Khalid↗

Regulators’ Financial Toolbox: Designing Low- and Moderate- Income (LMI) Community Solar Compensation Programs

On February 9, 2022, as part of the NARUC Winter Policy Summit, five NARUC Staff Subcommittees (Energy Resources and the Environment, Rate Design, Electricity, Electric Reliability and Resilience, and Consumers and the Public Interest) co-hosted two sessions on community solar. The first panel was Community Solar I: Benefits for Low- and Moderate-Income Consumers, featuring opening remarks from moderator Hon. Eric Blank, Chairman of the Colorado Public Utilities Commission, and presentations from Richard Caperton, Vice President, Policy and Market Development, Arcadia, on behalf of the Coalition for Community Solar Access (CCSA); Chris Nichols, Senior Program Director, Groundswell; and Ted Trabue, Managing Director, DC Sustainable Energy Utility. See presentations and recordings. The second panel, titled What is Community Solar 2: Cost Impacts to Participants and Non-Participants, featured opening remarks from moderator Jamie Barber, Director of the Energy Efficiency and Renewable Energy Unit at the Georgia Public Service Commission, and presentations from Dr. Gabriel Chan, Associate Professor, Humphrey School of Public Affairs, University of Minnesota; Matthew McDonnell, Managing Director, Strategen Consulting; and Katie Chiles Ottenweller, Southeast Director, Vote Solar. See presentations and recordings.

14 SOLAR ENERGY↗

Better Gas-Gap Thermal Switches For Sorption Compressors

Gas-gap thermal switches associated with sorption compressors of some heat pumps and cryogenic systems designed for higher performance, according to proposal, by introducing controlled turbulent flows into gas gaps. Utilizes convection in turbulent flow to transfer heat at greater rate. Design takes advantage of flow of working fluid. Working fluid also serve as heat transfer medium in gas gap.

Bhandari, Pradeep↗

An Atlas of Current Customer-Facing Utility Program Designs and Pricing

The National Renewable Energy Laboratory (NREL) and Kevala conducted a targeted literature review and leveraged extensive expertise, including team members with four decades of experience in the utility sector, to characterize utility programs and rate designs. This analysis delves into the motivations behind these programs and the various hurdles they face. Through this in-depth study, the team provides critical insights into the operational dynamics of utility programs, identifying key drivers and barriers that influence their effectiveness and implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Financial Impacts of a Combined Energy Efficiency and Net-Metered PV Portfolio on a Prototypical Northeast Utility

Reductions in electricity consumption from customer-funded energy efficiency (EE) programs and distributed photovoltaic (PV) are expected to dramatically increase over the next ten years. While EE programs and net-metered PV provide numerous utility, customer, and societal benefits, including utility cost reductions, lower customer bills, and achievement of clean energy public policy goals, they may contribute to stagnant or declining retail sales for electric utilities. Investor-owned utilities are concerned about stagnant or declining sales as they undermine existing regulatory and ratemaking approaches to cover fixed costs and may negatively impact utility profitability. Current retail rate designs allocate a large fraction of fixed costs to volumetric energy charges creating challenges for the utility’s recovery of its fixed costs due to reductions in retail sales between rate cases.

14 SOLAR ENERGY↗

Low Leakage Valves for Long Duration Missions

I.Nomenclaturemtypical_mission=internal mass of propellant lost over the course of a mission with Qtypicalmmission_goal=mass of propellant loss over the course of a mission with Qgoaltmission=theoretical mission durationQtypical=internal leakage rate found in commercially available valvesQgoal=internal leakage rate design goalρH2_STP=density of hydrogen at standard temperature and pressure.1NASA AST, Liquid Propulsion Valve Engineer.Valves, Actuators, and Ducts Design and Development Branch (ER14)2NASA AST, Liquid Propulsion Valve Engineer.Valves, Actuators, and Ducts Design and Development Branch (ER14)3NASA AST, Liquid Propulsion Valve Engineer (Retired).Valves, Actuators, and Ducts Design and Development Branch (ER14)4JSEG ESSCA, Engineering Specialist.Valves Actuators and Ducts Design and Development Branch (ER14)5NASA AST, Liquid Propulsion Valve Engineer.Valves, Actuators, and Ducts Design and Development Branch (ER14)6JSEG ESSCA, Valve Design and Development Engineer.Valves Actuators and Ducts Design and Development Branch (ER14) II.IntroductionCurrent aerospace cryogenic valves present challenges to potential long duration missions that utilize cryogenic propellants. Small interplanetary and long-life communication satellites typically utilize hypergolic propellants that operate at higher temperatures, making it easier to achieve very low internal leakage rates. Larger vehicles for long duration missions will likely need to utilize cryogenic-based chemical and nuclear systems to achieve mission requirements. Some early propulsion concepts are projected to require valves with a nominal size ranging from 3” to 10”.Currently available cryogenic aerospace valves typically have internal leakage rates which can range from 100 to 300 SCIM for 3” valves, or upwards of 2,000 SCIM for 10” valves. With just a few of these valves in a system, internal leakage could account for multiple tons of propellant loss over the course of a potential Mars mission, as shown in Figure 1.Figure 1 - Potential Propellant Loss Over the Course of a Long Duration MissionMost internal leakage rates can be attributed to inherent imperfections and misalignments, which result in imperfect contact between sealing surfaces, as shown in Figure 2.Figure 2 - Imperfections and Misalignments Between Sealing Surfaces The ER14 Branch at Marshall Space Flight Center (MSFC) has created a self-aligning seat and poppet design (shown in Figure 3) that allows a valve to be more tolerant of imperfect contacts. This design utilizes a metallic poppet head with five degrees of freedom that allows the poppet toself-align with the seat, reducing the need for tight tolerances.Figure 3 - Self-Aligning Seat and Poppet DesignIII.Test Valve DescriptionA series of development tasks have been conducted to study potential improvements to internal leakage rates. These tasks include 3 test valves (shown in Figure 4) to demonstrate the potential application to various configurations and sizes:A 3” isolation valve for liquid flows (similar to a fill and drain valve)A 3” relief valve for low temperature gas flows.An 8” pre-valve (similar to the engine isolation valve needed on a Nuclear Thermal Propulsion (NTP) engine).Figure 4 - Low Leakage Development Test ValvesThese valves have been developed and are currently being tested at liquid nitrogen (LN2) temperatures, and are anticipated to undergo testing at liquid hydrogen (LH2) temperatures in late 2022

Cody L Gilliland↗

Solar San Diego: The Impact of Binomial Rate Structures on Real PV-Systems

There is confusion in the marketplace regarding the impact of solar photovoltaics (PV) on the user's actual electricity bill under California Net Energy Metering, particularly with binomial tariffs (those that include both demand and energy charges) and time-of-use (TOU) rate structures. The City of San Diego has extensive real-time electrical metering on most of its buildings and PV systems, with interval data for overall consumption and PV electrical production available for multiple years. This paper uses 2007 PV-system data from two city facilities to illustrate the impacts of binomial rate designs. The analysis will determine the energy and demand savings that the PV systems are achieving relative to the absence of systems. A financial analysis of PV-system performance under various rates structures is presented. The data revealed that actual demand and energy use benefits of bionomial tariffs increase in summer months, when solar resources allow for maximized electricity production. In a binomial tariff system, varying on- and semi-peak times can result in approximately $1,100 change in demand charges per month over not having a PV system in place, an approximate 30% cost savings. The PV systems are also shown to have a 30%-50% reduction in facility energy charges in 2007. Future work will include combining demand and electricity charges and increasing the breadth of rate structures tested, including the impacts of non-coincident demand charges.

14 SOLAR ENERGY↗