Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “range measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Signals of primordial black holes at gravitational wave interferometers

Primordial black holes (PBHs) can form as a result of primordial scalar perturbations at small scales. This PBH formation scenario has associated gravitational wave (GW) signatures from second-order GWs induced by the primordial curvature perturbation, and from GWs produced during an early PBH dominated era. We investigate the ability of next generation GW experiments, including BBO, LISA, and CE, to probe this PBH formation scenario in a wide mass range. Measuring the stochastic GW background with GW observatories can constrain the allowed parameter space of PBHs for masses 10 9 – 10 27 g. We also discuss possible GW sources from an unconstrained region where light PBHs (< 10 9 g) temporarily dominate the energy density of the universe before evaporating. Here we show how PBH formation impacts the reach of GW observatories to the primordial power spectrum and provide constraints implied by existing PBH bounds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Feature Extraction for Pipeline Defects Inspection Based Upon Distributed Acoustic Fiber Optic Sensing Data

Fiber-optic distributed acoustic sensing (DAS) is becoming an increasingly important tool for real-time monitoring of energy and civil infrastructure structural health such as pipelines. We present a systematic theoretical study of the potential for DAS to be directly coupled with guided ultrasonic waves typically used in conventional acoustic non-destructive evaluation (NDE) methods for real-time pipeline health monitoring. We are referring to this innovative new NDE technique as ultrasonic guided wave and optical fiber sensor fusion. In the practical application of DAS coupled with guided ultrasonic waves, the structural design of (1) the specific guided waves excited, (2) the physical installation of the acoustic transducers and the fiber optic sensors, and (3) the functional performance specifications (gauge length, sensitivity, Etc.) of fiber optic DAS have an important influence on overall capabilities of the monitoring system. Meanwhile, physics-based analysis of acoustic waves is still a challenge due to the complex nature of the Lamb wave when it propagates, scatters, and disperses in the presence of structural defects. In this work, we simulate carbon steel pipes relevant for oil and gas pipeline applications with diameters of approximately 6-12” and wall thickness of 0.5” as the objects to be monitored. By establishing and implementing these capabilities, we seek to pursue an in-depth study on structural parameter optimization of DAS network, measurement range, and signal processing with an ultimate goal of increasing the sensitivity and efficacy of DAS to defect identification for various modes of corrosion expected in practice. To study the characteristics of scattered acoustic waves and performance of DAS for defect identification, we simulated the response of DAS for multiple pipe structures, defect types, and DAS sensor network configuration using finite element software Ansys, then the properties of signal response are extracted to construct defect-sensitive features. The raw data simulated, and the associated features extracted can ultimately be utilized as annotated training data to benchmark various designs for DAS applications, guided acoustic excitation sources, and learning model parameters to enhance early detection of potentially problematic defects.

Pipeline Defects Inspection, Fiber-optic sensors, ↗

Asi Nuclear Energy Sensors Data Portal Chatbot And Data Structuring Tool

The Idaho National Laboratory (INL) is advancing the development of an AI-powered chatbot and data structuring tool specifically designed to accelerate data mining processes for sensor-related information and seamlessly integrate the results into the ASI Sensors Data Portal (https://nes.energy.gov/). By doing so, the software aims to enhance the accessibility, usability, and organization of sensor data for nuclear energy applications. The software initial phase focuses on retrieving comprehensive datasets, prioritizing the past five years of publicly available information from the Office of Scientific and Technical Information (OSTI). These datasets will be meticulously processed to ensure compatibility, employing cleaning and preprocessing steps to eliminate irrelevant, incomplete, or corrupted information, thus establishing a robust foundation for subsequent AI use. The data will serve as the backbone for training an AI model and chatbot, which will act as an interactive tool enabling users to ask complex, context-specific questions and receive accurate, validated answers derived from constrained literature. In parallel, the project incorporates a data structuring process supported by AI to organize sensor information from multiple sources into a standardized format. This structured data will include detailed sensor specifications, such as measurement range, applications, accuracy, and operating conditions, generated and documented with AI. These specifications will be systematically integrated into the sensor portal. To maintain the highest levels of accuracy and relevance, all AI-generated outputs will be reviewed and validated by subject matter experts (SMEs), with additional fields or parameters added as needed. Future stages of the project aim to expand the dataset beyond OSTI to include other sources and potentially incorporate unclassified controlled information (UCI) with restricted access protocols to address security and confidentiality requirements.

Mapes, NormanJ. [Idaho National Laboratory (INL), ↗

In-situ polymerized and crosslinked electrolytes with interchangeable Li/Na transport for battery applications

The next generation of batteries requires electrolytes with high conductivity, mechanical stability, good adhesion with electrodes, wide electrochemical windows, and scalability. The present study introduces a concept of doped quasi single-ion conducting copolymers based on methacrylate-(trifluoromethanesulfonyl)imide (TFSI) and vinyl ethylene carbonate which at room temperature are mechanically robust and display ionic conductivities of ~0.1 mS/cm. These electrolytes can be polymerized/crosslinked in-situ, making them easily implementable in current battery manufacturing technologies. They also allow for switching between Li + and Na + transport using simple chemistry procedures. To demonstrate their potential for battery applications, the newly developed Li conductors have been tested in symmetric cells, exhibiting overall impedance below 350 Ohm and plating/stripping stability up to 1 mA/cm 2 . Moreover, lithium metal batteries incorporating this electrolyte and high-voltage Lithium Nickel Manganese Cobalt Oxide (NMC) cathodes show good capacity retention (~79%) during charging and discharging for 80 cycles at C/10 rate and a Coulombic efficiency close to 100% in the entire measurement range. The compositional, mechanical and electrochemical versatility of these electrolytes opens new venues for the design of polymer-based batteries capable of fast charging and extended cycle life, aligning with the current global green energy storage strategies.

Polymer electrolytes↗

Filtration Performance Results: Sierra Peaks Material No. 4

Sandia National Laboratories (SNL) assessed the filtration performance of materials from Sierra Peaks to identify alternatives which may perform similarly to materials used in FDA-approved N95 respirators. This work is meant to characterize the aerosol performance of materials to give Sierra Peaks information for them to determine if they elect to submit masks made using these materials for follow-on N95 certification testing at an accredited facility. The R&D testbed used is a large-scale filtration system designed to test commercial filter boxes. System modifications were performed to simulate, where possible, parameters defined by the National Institute for Occupational Safety and Health (NIOSH) for certification of filter materials for N95 respirators (NIOSH 2019). The system is a pull-through design. Air enters through a Laminar Flow Element (LFE) and the volumetric flow is measured based on the pressure drop across the LFE. Pressure is measured via a Pressure Transducer (PT). The air then passes through a High Efficiency Particulate Air (HEPA) filter to purge the air of ambient airborne particulates. Test aerosol is injected into the flow shortly after and mixing is induced via a coarse mesh. The airflow is allowed to fully develop prior to arriving at the test section. The aerosol then passes through the test material mounted in a box in the test section. Pressure drop across the test article is measured and aerosol sampling probes measure the aerosol concentrations upstream and downstream of the sample. The air passes through a second HEPA filter prior to being exhausted to ambient by a blower. A Topas aerosol generator is used to produce the test aerosol from Sodium Chloride (NaC1) dissolved in deionized (DI) water. Generated aerosol passes through a heated mixing chamber and a desiccant dryer to produce nanosized solid-state particulates. A dilution loop allows for the aerosol concentration to be regulated. The aerosol sampling probes upstream and downstream of the test section are aligned with the flow path. These are ducted directly to the aerosol sizing and counting instruments. A Laser Aerosol Spectrometer (LAS) was used for data collection in the original configuration of the system and was also used for initial testing in this project. Because the lower measurement range for the LAS is 90 nanometers (nm), the LAS was switched out for a more complicated Scanning Mobility Particle Sizer (SMPS) spectrometer system. The SMPS is comprised of an Electrostatic Classifier (EC), Differential Mobility Analyzer (DMA), and a Condensation Particle Counter (CPC). This enabled data collection at 75 nm, the particle size called out in the NIOSH guidelines.

36 MATERIALS SCIENCE↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. This type of product is mounted to upper walls or ceilings to treat air in the portion of the room above occupants; this allows for safe use of the room when the device is operating, but requires sufficient air mixing between upper and lower portions of the room. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance data allowed for comparison against manufacturer or vendor claims if the tested products included such claims. Some products had no performance data available for a given quantity (e.g., UV-C output power), and only four of the eight luminaires had radiant intensity distribution data files in a standard format (e.g., IES LM-63) available for download from product websites. The lack of publicly available performance data makes it difficult for potential buyers and specifiers to identify suitable products and design GUV systems for their specific applications. When products had performance claims, they were sometimes contradictory (e.g., unexplained differences between multiple power values) or ambiguous (e.g., measurement units conflict with quantity, unclear whether luminaire power or lamp power, unclear whether UV output power or UV-C output power). Three of the eight tested luminaires had claimed output power (i.e., radiant flux) values that exceeded measured values by more than an order of magnitude. There was substantial variation in UV-C radiant efficiency, with a measured range of 0.3–1.9% for LED and 0.4–2.1% for LPM, as shown in Figure 1. For example, the LPM luminaire with 0.4% radiant efficiency would need 5 times the amount of electrical energy used by the LPM luminaire with 2.1% radiant efficiency to produce the same amount of UV-C output power. LPM luminaires that had parabolic reflectors aligned with inclined louvers exhibited substantially higher UV-C radiant efficiency than tested luminaires with other designs, potentially cutting energy use by 75%. These results indicate a substantial opportunity for more energy efficient LPM luminaire designs, while demonstrating that UV LED luminaires can offer comparable UV-C radiant efficiency in this application. This may seem surprising, given that LED emitters have lower UV-C radiant efficiency than LPM lamps, but the efficiency-throttling louvers that are generally required for LPM luminaires typically are not needed for LEDs thanks to their directionality. However, lateral beam angles (which describe beam width as viewed from above) were 41–83° for LED luminaires versus 89–110° for LPM luminaires. More luminaires may be required if their lateral beam angles are relatively small, and coverage may be poor if UV-C radiant intensity distribution (i.e., beam shape) is not considered when designing systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The NREL Sensor Laboratory Detection of Hydrogen Emissions

The development of a functional hydrogen detection system is a multifaceted process that integrates hardware, deployments strategies, and analytics which can be supported by the NREL Sensor Laboratory: 1. Support of the design, validation and optimization of sensing prototypes; 2. Guide optimized sensing element development, including control electronics; 3. Laboratory testing to validate/optimize metrological performance (measurement range, detection limit, etc.); 4. Provide test sites for field deployments representative of real-world scenarios with controlled hydrogen releases; 5. Develop sensor placement and operation guidance; 6. Provide guidance on electronics to accommodate facility integration; 7. Electrical safety designs to allow for operation within restricted zones; 8. Integration into facility monitoring and control systems; 9. Guide incorporation of cyber security elements to protect facilities from malicious attacks; 10. Modeling and application of advanced analytics to detect and quantify emissions; 11. Higher Order dispersion models to guide sensor placement for reliable detection; 12. Advanced analytics for improved metrological performances, and to inform inverse modeling; 13. Market support and commercialization (national and international markets); 14. Commercial deployments in H2@SCALE markets (e.g., HUBs and other large-scale hydrogen markets); and 15. Leverage off international collaborations/partnerships (e.g., NREL is on the advisory board for the European initiative "pre-Normative Research on Hydrogen Releases Assessment"-NHyRA).

08 HYDROGEN↗

Proteomics reveals pathways linked to septoria canker resistance and susceptibility in Populus trichocarpa

A major threat to forest ecosystems and plantation forestry is the introduction of a non-native pathogen. Among non-domesticated populations with relatively high levels of genetic diversity, a measurable range of susceptibility to resistance can be expected. Identifying genetic determinants of resistant and susceptible individuals can inform the development of new strategies to engineer disease resistance. Here we describe pathogen-induced changes in the proteome of Populus trichocarpa stem tissue in response to Sphaerulia musiva (Septoria canker). This hemibiotrophic fungal pathogen causes stem canker disease in susceptible poplar genotypes. Proteomics analyses were performed on stem tissue harvested across 0-, 12-, 24- and 48-h post-inoculation with Septoria from three genotypes including one resistant (BESC-22) and two susceptible [BESC-801; Nisqually-1 (NQ-1)]. In total, 11,897 Populus proteins at FDR <0.01 were identified across all time points and genotypes. Analysis of protein abundances between genotypes revealed that the resistant poplar genotype (BESC-22) mounts a rapid and sustained defense response involving pattern recognition receptors, calcium signaling proteins, SAR inducers, transcriptional regulators, resistance proteins, and proteins involved with the hypersensitive response. One susceptible genotype (BESC-801) had a downregulated and delayed defense response whereas the second susceptible genotype (NQ-1) lacked a distinct pattern. Overall, the proteome-wide and protein-specific trends suggest that responses to the Septoria canker infection are genotype-specific for the naïve host, Populus trichocarpa .

59 BASIC BIOLOGICAL SCIENCES↗

Development of Readily Available & Robust High Heat Flux Gardon Gauges

Concentrated solar power (CSP) technologies deliver concentrated solar energy as a heat source to industrial processes, power generation cycles, and chemical cycles. CSP systems require accurate and reliable high flux measurements, and next generation CSP systems will require flux measurement up to 1000 W/cm2. Existing flux measurement devices do not comprehensively meet the flux rating, cycle life, cost, and lead-time needs of stakeholders, necessitating the development of an improved flux sensor. In this study, Sandia National Laboratories (SNL) partnered with Hukseflux Thermal Sensors to develop a low-cost, short lead-time, and robust flux sensor rated to 250 W/cm2. Three prototype circular foil gauge designs were assessed for performance at the National Solar Thermal Test Facility (NSTTF) at SNL. Each gauge design measured flux up to 250 W/cm2 with <5% measurement error. Following baseline error quantification, gauges were exposed to flux above 500 W/cm2 to assess gauge failure mechanisms. Gauges physically survived >500 W/cm2 flux exposure, but measurement error was found to increase after foil coatings reached 400 °C. The results of this study suggest that coating optical properties change at excessive temperatures and that foil coating temperature, rather than heat flux level, dictates the acceptable gauge measurement range.

McLaughlin, Luke (ORCID:0000000303711310)↗

High power handling digitizer using photonics

Devices, methods for analog-to-digital converters (ADCs) that perform high-dynamic range measurements based on optical techniques are disclosed. In one example aspect, an optical encoder includes a polarization rotator configured to receive a train of optical pulses, and an electro-optic (EO) modulator coupled to an output of the polarization rotator. The EO modulator is configured to receive a radio frequency (RF) signal and to produce a phase modulated signal in accordance with the RF signal. The optical encoder also includes a polarizing beam splitter coupled to the output of the EO modulator; and an optical hybrid configured to receive two optical signals from the polarizing beam splitter and to produce four optical outputs that are each phase shifted with respect to one another.

DeVore, Peter Thomas Setsuda↗

Safety Compliance Verification of Fuel Cell Electric Vehicle Exhaust

NREL has been developing compliance verification tools for allowable hydrogen levels prescribed by the Global Technical Regulation Number 13 (GTR-13) for hydrogen fuel cell electric vehicles (FCEVs). As per GTR-13, FCEV exhaust is to remain below 4 vol% H2 over a 3-second moving average and shall not at any time exceed 8 vol% H2 and that this requirement is to be verified with an analyzer that has a response time of less than 300 ms. To be enforceable, a means to verify regulatory requirements must exist. In response to this need, NREL developed a prototype analyzer that meets the GTR metrological requirements for FCEV exhaust analysis. The analyzer was tested on a commercial fuel cell electric vehicle (FCEV) under simulated driving conditions using a chassis dynamometer at the Emissions Research and Measurement Section of Environment and Climate Change Canada and FCEV exhaust was successfully profiled. Although the prototype FCEV Exhaust Analyzer met the metrological requirements of GTR-13, the stability of the hydrogen sensor was adversely impacted by condensed water in the sample gas. FCEV exhaust is at an elevated temperature and nearly saturated with water vapor. Furthermore, condensed water is present in the form of droplets. Condensed water in the sample gas can collect on the hydrogen sensing element, which would not only block access of hydrogen to the sensor but can also permanently damage the sensor. In the past year, the design of the gas sampling system was modified to mitigate against the transport of liquid water to the sensing element. Laboratory testing confirmed the effectiveness of the modified sampling system water removal strategy while maintaining the measurement range and response time required by GTR-13. Testing of the upgraded analyzer design on an FCEV operating on a chassis dynamometer is scheduled for the summer of 2021.

DIRECT ENERGY CONVERSION,HYDROGEN↗

NON-DESTRUCTIVE POST IRRADIATION EXAMINATION OF FIRST CYCLE ACCIDENT TOLERANT AND ADVANCED ZIRCONIUM ALLOY HIGH BURNUP FUEL RODS

Post irradiation examination (PIE) of accident tolerant fuel concepts and high burnup uranium dioxide advanced zirconium alloy clad fuel contribute to near term nuclear industry goals of enhancing light water reactor safety and economics. Westinghouse is developing chromium coated zirconium alloy cladding as an accident tolerant fuel option for current pressurized water reactors. Examination of high burnup fuel further augments the technical foundation for extending the peak rod average burnup limits beyond the current regulatory limit of 62 MWd/kgU. Seven fuel rods were received at the Oak Ridge National Laboratory Irradiated Fuel Examination Facility. This includes three chromium coated zirconium alloy fuel rods and four high burnup advanced zirconium alloy fuel rods. Six of the seven rods were fueled with standard uranium dioxide while one of the chromium coated rods contained Westinghouse’s ADOPT fuel. The overall hot-cell PIE plan and some PIE results have been presented previously. This paper focuses on the additional non-destructive examination and fission gas release. Highlights from visual examination of these rods are presented. The chromium coating showed little to no visual change following irradiation. Observations of the axial burnup trends in the fuel rods are derived from full rod axial gamma-ray scans with additional observations related to local fission product migration. The axial dimensional changes of the seven rods are evaluated. As expected, creep down had not yet occurred in the chromium coated rods, and the maximum diameter strain in the high burnup advanced zirconium alloy cladding was less than 0.5%. Finally, the steady state fission gas release for these rods was measured ranging from 4.1% to 17.6% which matched expectation from literature. These fuel rods now await further destructive examination.

Harp, Jason↗

High power handling digitizer using photonics

Devices, methods for analog-to-digital converters (ADCs) that perform high-dynamic range measurements based on optical techniques are disclosed. In one example aspect, an optical encoder includes a polarization rotator configured to receive a train of optical pulses, and an electro-optic (EO) modulator coupled to an output of the polarization rotator. The EO modulator is configured to receive a radio frequency (RF) signal and to produce a phase modulated signal in accordance with the RF signal. The optical encoder also includes a polarizing beam splitter coupled to the output of the EO modulator; and an optical hybrid configured to receive two optical signals from the polarizing beam splitter and to produce four optical outputs that are each phase shifted with respect to one another.

DeVore, Peter Thomas Setsuda↗

12 C(e,e'pN) measurements of short range correlations in the tensor-to-scalar interaction transition region

High-momentum configurations of nucleon pairs at short-distance are probed using measurements of the $^{12}$C$(e,e'p)$ and $^{12}$C$(e,e'pN)$ reactions (where $N$ is either $n$ or $p$), at high-$Q^2$ and $x_B>1.1$. The data span a missing-momentum range of 300--1000 MeV/c and are predominantly sensitive to the transition region of the strong nuclear interaction from a Tensor to Scalar interaction. The data are well reproduced by theoretical calculations using the Generalized Contact Formalism with both chiral and phenomenological nucleon-nucleon ($NN$) interaction models. This agreement suggests that the measured high missing-momentum protons up to $1000$ MeV/c predominantly belong to short-ranged correlated (SRC) pairs. The measured $^{12}$C$(e,e'pN)$ / $^{12}$C$(e,e'p)$ and $^{12}$C$(e,e'pp)$ / $^{12}$C$(e,e'pn)$ cross-section ratios are consistent with a decrease in the fraction of proton-neutron SRC pairs and increase in the fraction of proton-proton SRC pairs with increasing missing momentum. This confirms the transition from an isospin-dependent tensor $NN$ interaction at $\sim 400$ MeV/c to an isospin-independent scalar interaction at high-momentum around $\sim 800$ MeV/c as predicted by theoretical calculation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hierarchical Modeling to Enhance Spectrophotometry Measurements—Overcoming Dynamic Range Limitations for Remote Monitoring of Neptunium

A robust hierarchical model has been demonstrated for monitoring a wide range of neptunium concentrations (0.75–890 mM) and varying temperatures (10–80 °C) using chemometrics and feature selection. The visible–near infrared electronic absorption spectrum (400–1700 nm) of monocharged neptunyl dioxocation (Np(V) = NpO2+) includes many bands, which have molar absorption coefficients that differ by nearly 2 orders of magnitude. The shape, position, and intensity of these bands differ with chemical interactions and changing temperature. These challenges make traditional quantification by univariate methods unfeasible. Measuring Np(V) concentration over several orders of magnitude would typically necessitate cells with varying path length, optical switches, and/or multiple spectrophotometers. Alternatively, the differences in the molar extinction coefficients for multiple absorption bands can be used to quantify Np(V) concentration over 3 orders of magnitude with a single optical path length (1 mm) and a hierarchical multivariate model. In this work, principal component analysis was used to distinguish the concentration regime of the sample, directing it to the relevant partial least squares regression submodels. Each submodel was optimized with unique feature selection filters that were selected by a genetic algorithm to enhance predictions. Through this approach, the percent root mean square error of prediction values were ≤1.05% for Np(V) concentrations and ≤4% for temperatures. This approach may be applied to other nuclear fuel cycle and environmental applications requiring real-time spectroscopic measurements over a wide range of conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Long-range Doppler lidar measurements of wind turbine wakes and their interaction with turbulent atmospheric boundary-layer flow at Perdigao 2017

As part of the Perdigão 2017 campaign, vertical RHI (range-height indicator) scans with long-range pulsed Doppler wind lidars were performed aligned with the main wind direction and a wind turbine (WT) located on a mountain ridge. The measurements are used to not only retrieve flow velocities, but also their variance and - by using the turbulent broadening of the Doppler spectrum - also turbulent kinetic energy (TKE) dissipation rate. The study shows that turbulence in the WT wake is dependent on the turbulence of the inflow, but also on atmospheric stability. In stable atmospheric conditions, wakes could be analyzed up to five rotor diameters downstream (D) and showed the maximum turbulence in the wake at 2-3 D, whereas in unstable conditions, the maximum was found at 2 D and the wake could not be detected further than 3 D. A clear dependency of wake turbulence enhancement on inflow turbulence intensity is found, which levels out to no further enhancement at turbulence intensities of 30%.

17 WIND ENERGY↗

Machine-learning identification of the variability of mean velocity and turbulence intensity for wakes generated by onshore wind turbines: Cluster analysis of wind LiDAR measurements

Light detection and ranging (LiDAR) measurements of isolated wakes generated by wind turbines installed at an onshore wind farm are leveraged to characterize the variability of the wake mean velocity and turbulence intensity during typical operations, which encompass a breadth of atmospheric stability regimes and rotor thrust coefficients. The LiDAR measurements are clustered through the k-means algorithm, which enables identifying the most representative realizations of wind turbine wakes while avoiding the imposition of thresholds for the various wind and turbine parameters. Considering the large number of LiDAR samples collected to probe the wake velocity field, the dimensionality of the experimental dataset is reduced by projecting the LiDAR data on an intelligently truncated basis obtained with the proper orthogonal decomposition (POD). The coefficients of only five physics-informed POD modes are then injected in the k-means algorithm for clustering the LiDAR dataset. The analysis of the clustered LiDAR data and the associated supervisory control and data acquisition and meteorological data enables the study of the variability of the wake velocity deficit, wake extent, and wake-added turbulence intensity for different thrust coefficients of the turbine rotor and regimes of atmospheric stability. Furthermore, the cluster analysis of the LiDAR data allows for the identification of systematic off-design operations with a certain yaw misalignment of the turbine rotor with the mean wind direction.

17 WIND ENERGY↗