Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of a portable, high-energy radiographic source

A two-year program has been undertaken to develop a portable high-energy (3-4 MeV) radiographic system for in-service and repair inspections of components at nuclear power stations. The basic design concept uses a lightweight portable linear accelerator. This paper describes the design objectives, concepts employed, and progress to date. Specific potential applications and accompanying radiographic techniques are discussed, along with novel beam-angulation devices that permit utilization in areas of highly restricted access.

Reinhart, E. R.↗

Lead Scales for X-Radiographs

Indentations made by typing on lead tape. Lead scales for inclusion in x-radiographs as length and position references created by repeatedly imprinting character like upper-case I, L, or V, or lower-case L into lead tape with typewriter. Character pitch of typewriter serves as length reference for scale. Thinning of tape caused by impacts of type shows up dark in radiograph.

Burley, Richard K.↗

Ultrasonic and radiographic evaluation of advanced aerospace materials: Ceramic composites

Two conventional nondestructive evaluation techniques were used to evaluate advanced ceramic composite materials. It was shown that neither ultrasonic C-scan nor radiographic imaging can individually provide sufficient data for an accurate nondestructive evaluation. Both ultrasonic C-scan and conventional radiographic imaging are required for preliminary evaluation of these complex systems. The material variations that were identified by these two techniques are porosity, delaminations, bond quality between laminae, fiber alignment, fiber registration, fiber parallelism, and processing density flaws. The degree of bonding between fiber and matrix cannot be determined by either of these methods. An alternative ultrasonic technique, angular power spectrum scanning (APSS) is recommended for quantification of this interfacial bond.

Generazio, Edward R.↗

Method of radiographic inspection of wooden members

The invention is a method to be used for radiographic inspection of a wooden specimen for internal defects which includes the steps of introducing a radiopaque penetrant into any internal defects in the specimen through surface openings; passing a beam of radiation through a portion of the specimen to be inspected; and making a radiographic film image of the radiation passing through the specimen, with the radiopaque penetrant in the specimen absorbing the radiation passing through it, thereby enhancing the resulting image of the internal defects in the specimen.

Berry, Maggie L.↗

Experiment K-6-27. Analysis of radiographs and biosamples from primate studies

Serial high-contrast radiographs were obtained of both arms and the right leg of two flight and four control monkeys for the period L-60 to S+16. Longitudinal growth of the tibia, radius and ulna was linear over this period in the control monkeys. In the flight monkey for whom the feeder malfunctioned, there were significant decreases in growth of the long bones. There were also hypermineralized growth arrest lines produced in the distal radial and ulnar metaphyses following resumption of growth. In the other flight monkey, there was a suggestion of decreased long bone growth during flight and immediate postflight periods, but this recovered by the end of the postflight control experiment. There was also an increase in intracortical resorption, indicative of skeletal activation. No major changes in cortical thickness or other parameters were noted, but modification of the techniques to obtain very high quality radiographs in further studies should allow subtle changes in these processes to be quantified.

Cann, C.↗

Verifying X-Radiographs With Computed Tomographs

Nondestructive technique gives added confidence in inspection. Ambiguous indications in radiographic inspections of metal castings checked by computed tomography. Fast and inexpensive conventional x-ray inspection used to make film image of overall casting, and slower, more costly computed tomography used to reinspect relatively few parts of casting presenting possible diffraction patterns or other difficult-to-interpret features. Method effective in resolving ambiguities in radiographs of turbine blades. Provides same information as metallurgical sectioning.

Roy, Jagatjit↗

Seed viability detection using computerized false-color radiographic image enhancement

Seed radiographs are divided into density zones which are related to seed germination. The seeds which germinate have densities relating to false-color red. In turn, a seed sorter may be designed which rejects those seeds not having sufficient red to activate a gate along a moving belt containing the seed source. This results in separating only seeds with the preselected densities representing biological viability lending to germination. These selected seeds demand a higher market value. Actual false-coloring isn't required for a computer to distinguish the significant gray-zone range. This range can be predetermined and screened without the necessity of red imaging. Applying false-color enhancement is a means of emphasizing differences in densities of gray within any subject from photographic, radiographic, or video imaging. Within the 0-255 range of gray levels, colors can be assigned to any single level or group of gray levels. Densitometric values then become easily recognized colors which relate to the image density. Choosing a color to identify any given density allows separation by morphology or composition (form or function). Additionally, relative areas of each color are readily available for determining distribution of that density by comparison with other densities within the image.

Vozzo, J. A.↗

Linear Calibration of Radiographic Mineral Density Using Video-Digitizing Methods

Radiographic images can provide quantitative as well as qualitative information if they are subjected to densitometric analysis. Using modern video-digitizing techniques, such densitometry can be readily accomplished using relatively inexpensive computer systems. However, such analyses are made more difficult by the fact that the density values read from the radiograph have a complex, nonlinear relationship to bone mineral content. This article derives the relationship between these variables from the nature of the intermediate physical processes, and presents a simple mathematical method for obtaining a linear calibration function using a step wedge or other standard.

Martin, R. Bruce↗

Linear Calibration of Radiographic Mineral Density Using Video-Digitizing Methods

Radiographic images can provide quantitative as well as qualitative information if they are subjected to densitometric analysis. Using modem video-digitizing techniques, such densitometry can be readily accomplished using relatively inexpensive computer systems. However, such analyses are made more difficult by the fact that the density values read from the radiograph have a complex, nonlinear relationship to bone mineral content. This article derives the relationship between these variables from the nature of the intermediate physical processes, and presents a simple mathematical method for obtaining a linear calibration function using a step wedge or other standard.

Martin, R. Bruce↗

Study of Radiographic Linear Indications and Subsequent Microstructural Features in Gas Tungsten Arc Welds of Inconel 718

This study presents examples and considerations for differentiating linear radiographic indications produced by gas tungsten arc welds in a 0.05-in-thick sheet of Inconel 718. A series of welds with different structural features, including the enigma indications and other defect indications such as lack of fusion and penetration, were produced, radiographed, and examined metallographically. The enigma indications were produced by a large columnar grain running along the center of the weld nugget occurring when the weld speed was reduced sufficiently below nominal. Examples of respective indications, including the effect of changing the x-ray source location, are presented as an aid to differentiation. Enigma, nominal, and hot-weld specimens were tensile tested to demonstrate the harmlessness of the enigma indication. Statistical analysis showed that there is no difference between the strengths of these three weld conditions.

Walley, J. L.↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving manganin gauge measurements near radiographic fiducials

In dynamic experiments diagnosed with radiography and stress gauges, the gauges are often placed adjacent to radio-graphic fiducials, such as Ta foil, which perturbs the stress measurement. We conducted experiments to test the performance of different arrangements of manganin stress gauges and Ta foils. Three different gauge/foil configurations were tested, as well as a solitary gauge as control. Gauge/foil layers were placed between high-density polyethylene (HDPE) discs and impacted by a projectile in a gas gun, a simplification of a dynamic, high explosive experiment configuration. The stress measurements were minimally perturbed when a section of foil was removed near the active element of the gauge, as expected. In conclusion, a follow-up experiment showed that the modification to the foil has minimal impact on the radiographic measurement of the dynamic flow.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Simulations of wavelength-multiplexed holography for single-shot spatiotemporal characterization of NIF’s advanced radiographic capability (ARC) laser

We simulate the use of a newly developed single-shot wavelength-multiplexed holography-based diagnostic, STRIPED FISH, to fully characterize the as-delivered laser pulses of the National Ignition Facility’s Advanced Radiographic Capability (NIF-ARC) laser. To that end, we have performed simulations of the NIF-ARC pulse incorporating (a) a time-integrated spatial-profile measurement and a complete temporal-intensity-and-phase measurement using a frequency resolved optical gating, but without any spatiotemporal pulse characterizations, and (b) simulated first-order spatiotemporal distortions, which could be measured on a single shot if a STRIPED FISH device were deployed.

47 OTHER INSTRUMENTATION↗

Simulated X-Ray Radiographic Performance of a Bismuth-Loaded PVT Array

Recent material advancements in organic plastic scintillators enable marked increases in material detection efficiency, light yield, and pulse shape discrimination properties. These advances may resolve significant capability gaps for lowcost, portable, and durable dual-particle imaging (DPI) systems for nuclear safety, security, and safeguard purposes. One such material, a 21% bismuth-loaded polyvinyl toluene (BiPVT), is computationally evaluated as a small, pixelated radiographic array using Monte Carlo N-Particle (MCNP) and Zemax OpticStudio, and it is compared to identical evaluations of EJ-200 and EJ-256 arrays. MCNP software enables estimates of particle interaction and energy deposition, while OpticStudio computes optical light transport within each material. Here, computational estimates of spatial resolution and relative light collection at 370 kVp are found to agree with experimental results for both EJ-200 and EJ-256 arrays, thereby validating predictions of the same for the BiPVT array. As such, for equivalent exposures at 370 kVp, a BiPVT array may provide ~20× the light collection expected from EJ-200 and ~10× that expected from EJ-256. Similar comparisons of estimated light collection are also computed at 150 and 270 kVp, and these results suggest that BiPVT will provide significantly improved performance over EJ-200 and EJ-256 across all energies practical for portable X-ray radiography.

42 ENGINEERING↗

Uncertainties in Density and Simulation Parameters for Radiographic Reconstructions Using Machine Learning

We will develop new and improved methods that will enable a fuller and more extensive use of experimental data, such as from radiographic imaging, towards better characterizing and reducing uncertainties in predictive modeling of weapons performance. We will achieve this by leveraging recent developments in the areas of computational imaging, statistical and machine learning, and reduced order modeling. Key new aspects of our approach include (a) a coupling of deep learning based density reconstruction with fast hydrodynamics simulators that will permit the development of certain guarantees on extrapolatability and bounds on certain other hydrodynamics-related para- metric uncertainties and (b) a dual approach towards better characterizing uncertainties in density reconstruction using deep learning based surrogates to accelerate Bayesian reconstructions on the one hand and using variational inference and Bayesian machine learning on the other hand.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Time resolved radiographs and fuel density of the stagnation phase of Inertial Confinement Fusion implosions (NSA report)

This report contains a figure and caption. Left: Compton radiographs of a 3-shock HDC THD layered implosion recorded 10ps before and 160ps after bang-time (BT) at the NIF, using >50keV point projection backlighters generated by irradiating a 25μm-diameter Au wire with 30ps-long ARC pulses. Right: Reconstructed density distributions of fuel and remaining ablator showing significant 3D structure and top-down asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Self-Magnetic Pinch (SMP) Radiographic Diode Performance on RITS-6 at Sandia National Laboratories

The goals of an electron beam-driven radiographic source are the focusing of high current at high voltage to a minimal spot size with excellent shot-to-shot reproducibility. The Self-Magnetic Pinch (SMP) diode makes use of such an intense electron beam impinging on a high-atomic weight (tantalum) converter, a counter-streaming ion beam to help minimize the spot size, and operation in a magnetic field-free diode region which further encourages small spot size. Through a series of diode development experiments, output voltages up to 12.5 MV and output currents up to 225 kA have been characterized, with resulting spot sizes below ~ few mm. Scaling studies with parameter variation, such as diode aspect ratio and anode-cathode (A-K) gap variation, give systematic validation to what has heretofore been noted anecdotally by other research groups. While the lack of an imbedded magnetic field helps minimize the SMP spot size, a secondary result may be the generation of beam instabilities which can terminate the radiation pulse. There is anecdotal evidence that in-situ DC heating of the diode region can help stabilize the beam pinch. Clear experimental evidence exists that DC heating/RF cleaning results in better control over the counter-streaming ion population. Expanded use of spatial dose-rate detection is shown to yield new insights into electron beam dynamics in the SMP diode. An attendant study of the SMP diode as a load for an Inductive Voltage Adder (IVA) driver leads to insights into the behavior of the IVA-SMP diode configuration, viewed as a total system, and yields constraints on the overall impedance behavior of the SMP diode load.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiographic Imaging and Tomography

Radiographic imaging and tomography (RadIT) come in many flavors such as X-ray imaging and tomography (IT), proton IT, neutron IT, muon IT, neutrino IT, etc. We identify five RadIT themes: Physics, Sources, Detectors, Methods, and Data Science, which are integral parts of image interpretation and three-dimensional (3D) tomographic reconstruction. Traditionally, RadIT have been driven by medicine, non-destructive testing, material sciences, and security applications. The latest thrusts of growth come from automation, machine vision, additive manufacturing and virtual reality (‘metaverse’). The five RadIT themes parallel their counterparts in optical IT. Synergies among different forms of RadIT and with optical IT motivate further advances towards multi-modal IT and quantum IT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗