Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Dose-Weighted Radiographic Source-Spot Size

The spatial resolution of a flash radiograph is determined by the time-integrated size of the radiation source. Since the radiation pulse includes the beam head and tail, which may be substantially larger than the beam body, the radiation source is larger than the focused flattop of the electron beam pulse. Moreover, the radiation dose rate is weighted by both beam current and electron energy, and it is the radiation dose that forms the radiograph image. Therefore, in order to estimate radiographic resolution from computer simulations of a focused electron beam, one should use a dose weighted moment analysis of the radiation source distribution. This approach is used to show that, in the absence of beam effects other than space-charge and emittance, radiographic resolution for Scorpius exceeds requirements, regardless of reasonable timing options for current and gap-voltage pulses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SDRD Image Data Delivery 1/4

This is a collection of radiographic image data collected at the SEALab test bed at Los Alamos operations.

97 MATHEMATICS AND COMPUTING↗

Monte Carlo N-Particle Transport Performance of Predicting Digital Radiographic IQI Inspection

The identification of porosity, geometric noncompliance, and other defect types are critical to the qualification of materials and components. X-ray radiographic nondestructive testing is a common industrial inspection method for process quality control and component qualification and certification. Digital radiography provides a quick and efficient alternative when compared to traditional film-based inspection. The quality of radiographic inspection is dependent on equipment specifications, such as the source spot size and detector pixel size, and the specific parameters selected for use for the radiographic technique. To evaluate if an x-ray system and technique is sufficient for a given requirement, a radiographic image quality indicator (IQI) can be used. Radiographic IQIs in hard to machine materials or hard to manufacture defects can be time consuming and expensive to manufacture. This study was conducted to evaluate current Savannah River National Laboratory (SRNL) x-ray imaging systems with a custom tantalum IQI and using Monte Carlo simulations to predict the performance of future systems. The tantalum IQI was tested using a Siefert Isovolt 420 keV x-ray tube with a Perkin Elmer XRD 1611 flat panel with 100-micron pixels. Using the Monte Carlo N-Particle transport software, the radiographic tally was used to simulate the photon flux through an identical tantalum IQI. These simulations provided a benchmark as to the best theoretical identification on a given system using our tantalum IQI. The simulations were refined to match SRNL’s current systems’ noise levels, leading to confidence in their ability to predict the performance of other systems that may be purchased and deployed in the future at the Savannah River Site. Future studies will be conducted to prove this research can be extended to artificially evaluate the ability for systems to identify critical defect sizes through x-ray radiographic inspection, drastically reducing the cost and time burdens of producing high-fidelity radiographic test articles.

digital X-ray radiography↗

3D X-Ray Luggage-Screening System

A three-dimensional (3D) x-ray luggage- screening system has been proposed to reduce the fatigue experienced by human inspectors and increase their ability to detect weapons and other contraband. The system and variants thereof could supplant thousands of xray scanners now in use at hundreds of airports in the United States and other countries. The device would be applicable to any security checkpoint application where current two-dimensional scanners are in use. A conventional x-ray luggage scanner generates a single two-dimensional (2D) image that conveys no depth information. Therefore, a human inspector must scrutinize the image in an effort to understand ambiguous-appearing objects as they pass by at high speed on a conveyor belt. Such a high level of concentration can induce fatigue, causing the inspector to reduce concentration and vigilance. In addition, because of the lack of depth information, contraband objects could be made more difficult to detect by positioning them near other objects so as to create x-ray images that confuse inspectors. The proposed system would make it unnecessary for a human inspector to interpret 2D images, which show objects at different depths as superimposed. Instead, the system would take advantage of the natural human ability to infer 3D information from stereographic or stereoscopic images. The inspector would be able to perceive two objects at different depths, in a more nearly natural manner, as distinct 3D objects lying at different depths. Hence, the inspector could recognize objects with greater accuracy and less effort. The major components of the proposed system would be similar to those of x-ray luggage scanners now in use. As in a conventional x-ray scanner, there would be an x-ray source. Unlike in a conventional scanner, there would be two x-ray image sensors, denoted the left and right sensors, located at positions along the conveyor that are upstream and downstream, respectively (see figure). X-ray illumination may be provided by a single source or by two sources. The position of the conveyor would be detected to provide a means of matching the appropriate left- and right-eye images of an item under inspection. The appropriate right- and left-eye images of an item would be displayed simultaneously to the right and left eyes, respectively, of the human inspector, using commercially available stereo display screens. The human operator could adjust viewing parameters for maximum viewing comfort. The stereographic images thus generated would differ from true stereoscopic images by small distortions that are characteristic of radiographic images in general, but these distortions would not diminish the value of the images for identifying distinct objects at different depths.

Fernandez, Kenneth↗

A profile monitor for proton radiography experiments at the Los Alamos Neutron Science Center

The Proton Radiography (pRad) facility at the Los Alamos Neutron Science Center utilizes pulses of protons delivered by the 800 MeV linear accelerator to produce a series of radiographic images to study the dynamic behavior of materials under extreme conditions. Radiographs taken with an empty field of view, or beam pictures, are used to normalize transmission. However, because the center of the proton beam shifts between pulses, an in situ method for measuring beam position is required to normalize images for beam movement to perform absolute radiography. The beam profile monitor described here uses an array of scintillating fibers positioned in the beam path to produce light proportional to beam intensity across the beam cross section. This light is detected using fast photodiodes and a digital oscilloscope, providing a response time of several nanoseconds—suitable for measuring the 50-ns proton pulses used in pRad. The profile monitor achieves a measured position precision of 40 μm and an intensity precision of 0.7%, allowing for beam movement corrections to be applied to images, thereby improving data accuracy and image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Diffraction and Imaging Study of Imperfections of Crystallized Lysozyme with Coherent X-Rays

Phase-sensitive x-ray diffraction imaging and high angular-resolution diffraction combined with phase contrast radiographic imaging are employed to characterize defects and perfection of a uniformly grown tetragonal lysozyme crystal in symmetric Laue case. The fill width at half-maximum (FWHM) of a 4 4 0 rocking curve measured from the original crystal is approximately 16.7 arcseconds, and defects, which include point defects, line defects, and microscopic domains, have been clearly observed in the diffraction images of the crystal. The observed line defects carry distinct dislocation features running approximately along the <110> growth front, and they have been found to originate mostly at a central growth area and occasionally at outer growth regions. Individual point defects trapped at a crystal nucleus are resolved in the images of high sensitivity to defects. Slow dehydration has led to the broadening of the 4 4 0 rocking curve by a factor of approximately 2.4. A significant change of the defect structure and configuration with drying has been revealed, which suggests the dehydration induced migration and evolution of dislocations and lattice rearrangements to reduce overall strain energy. The sufficient details of the observed defects shed light upon perfection, nucleation and growth, and properties of protein crystals.

Hu, Zheng-Wei↗

Diffraction and imaging study of imperfections of crystallized lysozyme with coherent X-rays

Phase-contrast X-ray diffraction imaging and high-angular-resolution diffraction combined with phase-contrast radiographic imaging were employed to characterize defects and perfection of a uniformly grown tetragonal lysozyme crystal in the symmetric Laue case. The full-width at half-maximum (FWHM) of a 4 4 0 rocking curve measured from the original crystal was approximately 16.7 arcsec and imperfections including line defects, inclusions and other microdefects were observed in the diffraction images of the crystal. The observed line defects carry distinct dislocation features running approximately along the <1 1 0> growth front and have been found to originate mostly in a central growth area and occasionally in outer growth regions. Inclusions of impurities or formations of foreign particles in the central growth region are resolved in the images with high sensitivity to defects. Slow dehydration led to the broadening of a fairly symmetric 4 4 0 rocking curve by a factor of approximately 2.6, which was primarily attributed to the dehydration-induced microscopic effects that are clearly shown in X-ray diffraction images. The details of the observed defects and the significant change in the revealed microstructures with drying provide insight into the nature of imperfections, nucleation and growth, and the properties of protein crystals.

Muramidase/chemistry↗

Real-time damage characterization for GFRCs using high-speed synchrotron X-ray phase contrast imaging

Here, we report the application of high-speed synchrotron X-ray phase contrast imaging (PCI) in real-time damage characterization for glass fiber reinforced composites (GFRCs) subjected to dynamic loading. Dynamic single-edge notched bending (DSENB) experiments on pre-notched S-2 GFRCs were performed on a modified Kolsky compression bar. During loading, the synchrotron X-ray beam penetrated through the composite specimen from the side to detect damage evolution inside the material. Entire dynamic events were recorded by a high-speed camera as image sequences.0° and 90° unidirectional and cross-ply composites were investigated. An optical imaging technique was also employed to capture similar dynamic events in comparison with the radiographic imaging. It is demonstrated that high-speed X-ray PCI had sufficient phase contrast to characterize a crack initiation at a 20-μm spatial resolution within 920 ns and track the crack geometry during propagation, thereby providing reliable data to quantify the dynamic damage resistance of GFRCs. Furthermore, being capable of recognizing microscopic damage-related features at a sub-10-μm resolution, high-speed X-ray PCI provided fundamental material failure mechanisms to reveal the essential of macroscale structural failure of composites. It can also track the damage evolution inside and between individual plies of laminated composites. However, current high-speed X-ray PCI technique only supports in-situ observation and the high timing and spatial resolutions are limited within a field of view of ~2.5 mm in square, preventing its application in the three-dimensional and larger-area damage detection for GFRC structures.

42 ENGINEERING↗

High-contrast, convergent x-ray imaging with laser-Compton sources

Techniques are provided for the production of high-contrast, x-ray and/or gamma-ray radiographic images. The images have minimal contributions from object-dependent background radiation. The invention utilizes the low divergence, quasi-monoenergetic, x-ray or gamma-ray output from a laser-Compton source in combination with x-ray optical technologies to produce a converging x-ray or gamma-ray beam with which to produce a high-contrast, shadowgraph of a specific object. The object to be imaged is placed within the path of the converging beam between the x-ray optical assembly and the focus of the x-ray beam produced by that assembly. The beam is then passed through an optically thick pinhole located at the focus of the beam. Downstream of the pinhole, the inverted shadowgraph of the object is then recorded by an appropriate 2D detector array.

Barty, Christopher P. J.↗

(U) Endpoint Energy and Scintillator Geometry Effects on the Swank Factor, Quantum Efficiency, and DQE(0) for High-Energy Radiography

High-energy radiography is used to image imploding materials to better understand weapon design and performance. The Enhanced Capabilities for Subcritical Experiments (ECSE) is a new facility proposal that aims to collect radiographic images of nuclear material. As part of the facility design, we aim to optimize data quality and radiographic performance by investigating different detector designs. We addressed design decisions by simulating different scintillator designs using M CNP6 and calculated the quantum efficiency, Swank factor, and detective quantum efficiency at zero-frequency (DQE(O)). First, we investigated the effects of the x-ray endpoint energy on the detector response. We generated three x-ray spectra with endpoint energies of 20 MeV, 22 MeV, and 24 MeV. The three raw spectra were filtered using the Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) line-of-sight materials along with 1) flat field filtration using 7 cm tungsten alloy in the bullnose and 2) an FTO with 4 plates. The scatter-to-direct radiation ratio was much larger for FTO with 4 plates (50-60%) compared to the flat field with 7 cm of bullnose material (8%). We used these filtered spectra to calculate the detector response for the original DARHT segmented scintillator design. We found that the endpoint energy and filtration had a negligible effect on the detector response. The quantum efficiency was 0.63, the Swank factor was 0.84, and the DQE(O) was 0.53 for all six spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reconstructing Richtmyer–Meshkov instabilities from noisy radiographs using low dimensional features and attention-based neural networks

We develop an ML-based approach for density reconstruction based on transformer neural networks. This approach is demonstrated in the setting of ICF-like double shell hydrodynamic simulations wherein the parameters related to material properties and initial conditions are varied. The new method can robustly recover the complex topologies given by the Richtmyer-Meshkoff instability (RMI) from a sequence of hydrodynamic features derived from radiographic images corrupted with blur, scatter, and noise. A noise model is developed to characterize errors in extracting features from synthetic radiographs of the simulated density field. The key component of the network is a transformer encoder that acts on a sequence of features extracted from noisy radiographs. This encoder includes numerous self-attention layers that act to learn temporal dependencies in the input sequences and increase the expressiveness of the model. This approach is shown to exhibit an excellent ability to accurately recover the RMI growth rates, despite the gas-metal interface being greatly obscured by radiographic noise. Our approach can be applied in a broad array of fields involving shock physics and material science.

47 OTHER INSTRUMENTATION↗

Real-Time Radiographic In-Situ Characterization Of Ply Lift In Composite Aerospace Materials

The problem of ply lifting in composite materials is a significant issue for various aerospace and military applications. A fundamental element in the prevention or mitigation of ply lift is determination of the timing of the ply lifting event during exposure of the composite material to flight conditions. The Marshall Space Flight Center s Nondestructive Evaluation Team developed a real-time radiographic technique for the detection of ply lift in carbon phenolic ablative materials in situ during live firings of subscale test motors in support of NASA s Reusable Solid Rocket Motor program, using amorphous silicon detector panels. The radiographic method has successfully detected ply lifting in seven consecutive carbon phenolic converging cones attached to solid fuel torches, providing the time of ply lift initiation in each test. Post-processing of the radiographic images improved the accuracy of timing measurements and allowed measurement of the ply lifting height as a function of time. Radiographic data correlated well with independent pressure and temperature measurements that indicate the onset of ply lift in the nozzle material.

Beshears, Ronald D.↗

High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector

Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.

36 MATERIALS SCIENCE↗

Optimizing time integration for accurate recovery of shockwave interface location in radiography

We present simulations and experiments of time integrated radiographic imaging of a moving 1D shock wave front and a quantitative method for determining the statistical error in locating the shock front as a function of integration time and noise in the radiograph. We discuss the trade-off between increasing motion blur, which leads to decreased shock front location certainty, and increasing signal-to-noise, which leads to improved image quality with increasing integration time. We find an optimum integration time between a short integration time, where noise limits the error, and a long integration time, where motion blurring limits the error. This methodology can be used to tune experimental configurations to obtain the highest quality radiograph for a given experimental configuration.

Bremsstrahlung↗

Development of a broadband hard x-ray radiography platform for pulsed-power experiments

In this article, we develop and demonstrate a broadband hard x-ray radiography platform at the Zebra Pulsed Power Laboratory that integrates point-projection radiography, bremsstrahlung measurements, and hard x-ray pinhole imaging, designed to diagnose current-driven, cylindrically compressed matter. Initial laser-pulsed-power coupled experiments revealed that intense background radiation generated during 1 MA Zebra current shots overwhelmed laser-produced hard x-rays, obscuring radiographic images. Using combined spectral and spatial diagnostics, we identify energetic electrons accelerated by return currents as the dominant source of background hard x-rays, with electron energies inferred to be 3–4 MeV based on Monte Carlo simulations, and demonstrate mitigation through modifications to the radiation shielding and return-current configuration. The diagnostic platform was validated using a wire-pinch hard x-ray source, allowing radiographs of static 1-mm-diameter aluminum wires to be obtained while simultaneously measuring x-ray source spectra and spatial emission distributions within a single shot. Measured wire transmission profiles were quantitatively reconstructed using radiation transport simulations that incorporate an experimentally inferred two-temperature exponential x-ray spectrum from bremsstrahlung signal analysis and spatially distributed emission sources identified by pinhole imaging. Agreement between measured and simulated transmission profiles demonstrates the validity of the radiographic and x-ray source characterization approach, establishing this diagnostic platform as a promising tool for diagnosing magnetically driven, high-density plasmas relevant to warm dense matter and inertial fusion energy research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-driven high-resolution MeV x-ray tomography

The need for high-resolution MeV x-ray tomography to observe the three-dimensional structure of dense, large-sized objects is rapidly increasing for the non-destructive evaluation of critical additively manufactured parts, national security, and other applications. We report a demonstration of high-resolution MeV computed tomography of a dense, large object with a laser-driven x-ray source. A record detector-limited MeV radiograph resolution of < 200 µm as determined with the Bennett approximation of the point spread function was achieved by irradiating millimeter-thick tungsten targets with 300 TW femtosecond laser pulses at a 0.5 Hz repetition rate. A tungsten alloy step wedge spectrometer indicates that the peak of the x-ray emission is between 1 and 2 MeV, with an endpoint energy of 19 MeV. To illustrate the radiographic imaging capability of the system, a tomographic reconstruction of a nickel superalloy turbine blade ( maximum $ρr$ = 139 g/cm 2 ) with sub-millimeter resolution was performed using 2160 individual radiographs. The small x-ray source size opens the prospect of extremely high-resolution tomographs of large, dense objects. This laser-driven approach has major advantages for non-destructive evaluation.

47 OTHER INSTRUMENTATION↗

Thermographic imaging for high-temperature composite materials: A defect detection study

The ability of a thermographic imaging technique for detecting flat-bottom hole defects of various diameters and depths was evaluated in four composite systems (two types of ceramic matrix composites, one metal matrix composite, and one polymer matrix composite) of interest as high-temperature structural materials. The holes ranged from 1 to 13 mm in diameter and 0.1 to 2.5 mm in depth in samples approximately 2-3 mm thick. The thermographic imaging system utilized a scanning mirror optical system and infrared (IR) focusing lens in conjunction with a mercury cadmium telluride infrared detector element to obtain high resolution infrared images. High intensity flash lamps located on the same side as the infrared camera were used to heat the samples. After heating, up to 30 images were sequentially acquired at 70-150 msec intervals. Limits of detectability based on depth and diameter of the flat-bottom holes were defined for each composite material. Ultrasonic and radiographic images of the samples were obtained and compared with the thermographic images.

Roth, Don J.↗