Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Intensity Modulated Radiation Therapy (IMRT) With Simultaneously Integrated Boost Shortens Treatment Time and Is Noninferior to Conventional Radiation Therapy Followed by Sequential Boost in Adjuvant Breast Cancer Treatment: Results of a Large Randomized Phase III Trial (IMRT-MC2 Trial)

In the modern era, improvements in radiation therapy techniques have paved the way for simultaneous integrated boost irradiation in adjuvant breast radiation therapy after breast conservation surgery. Nevertheless, randomized trials supporting the noninferiority of this treatment to historical standards of care approach are lacking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Plasma Levels and Polymorphisms of Vitronectin Predict Radiation Pneumonitis in Patients With Lung Cancer Receiving Thoracic Radiation Therapy

Our previous findings have identified vitronectin (VTN) as a potential biomarker for radiation pneumonitis (RP) through proteomics and molecular mechanism studies. In a recent study, we further explored associations of plasma level and single nucleotide polymorphisms of VTN with the risk of RP in patients with lung cancer receiving radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Randomized Trial of Radiation Therapy With Weekly Cisplatin or Cetuximab in Low-Risk HPV-Associated Oropharyngeal Cancer (TROG 12.01) – A Trans-Tasman Radiation Oncology Group Study

The excellent prognosis of patients with low-risk human papillomavirus (HPV)- associated oropharyngeal squamous cell carcinoma has led to concerns about overtreatment and excessive toxicity with radiation therapy and cisplatin, leading to interest in de-intensification trials. We investigated whether cetuximab, an epidermal growth factor receptor targeting antibody, when combined with radiation therapy would result in a decrease in symptom burden and toxicity with similar efficacy compared with weekly cisplatin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reasons for Declining Applicant Numbers in Radiation Oncology From the Applicants' Perspective: Results From the Applicant Concerns and Radiation Oncology Sources Survey (ACROSS)

Applications to radiation oncology in the United States have decreased the past 3 years, resulting in unfilled residency positions (30 [14.5%] in 2019 and 35 [18.5%] in 2020). The aim of this study is to understand the concerns among radiation oncology applicants and whether these concerns may have led to a decline in applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Confinement of SIA Cluster Diffusion by Impurities on Radiation Defect Accumulation due to 14MeV neutrons in Tungsten

Impurities acting as traps, reduce the self-interstitial atom (SIA) cluster mobility, thereby increasing recombination and in turn enhancing radiation-resistance of polycrystalline materials. However, at elevated temperatures, depending on SIA-trap (impurity) binding energy, SIA clusters may trap and detrap (detach) numerous times. In tungsten, SIA clusters of all sizes glide one-dimensionally (1D) along their Burgers vector direction. Hence, detrapped SIAs would retrace their path, confining their 1D-glide between traps. However, small SIA clusters can change the direction of their 1D-glide by overcoming a rotation barrier. In addition, impurities or solutes are known to reduce this barrier. A lower rotation barrier can result in detrapped SIA clusters that diffuse in a random 1D direction, effectively leading to 3D (net-3D) diffusion. Here we investigate the effect of two cases of SIA diffusion, namely confined-1D diffusion and net-3D diffusion, on the damage accumulation in polycrystalline tungsten under 14 MeV neutron irradiation using the object kinetic Monte Carlo method. Simulations were performed using cascade debris obtained from molecular dynamics simulations with primary knock-on atom (PKA) energies corresponding to 14 MeV neutrons. In the simulations with net-3D diffusion, SIA clusters of all sizes diffuse in a random 1D direction after the clusters detrap. While for the confined 1D diffusion case, SIA clusters larger than size 5 retain their original direction of 1D-glide. In both types of simulations, trapped vacancies are assumed to be permanently immobilized. Unexpectedly, the damage accumulation was lower with confined 1D diffusion than that with net-3D. We present a systematic comparison of the influence of the two cases of SIA diffusion on the radiation damage accumulation as a function of dose rate, detrapping barrier, and impurity concentration at 1025 K.

Accumulation and recovery of lattice damage, tungs↗

Spherical time-encoded radiation imaging simulations

Radiation source localization is important for nuclear nonproliferation and can be obtained using time-encoded imaging systems with unsegmented detectors. A scintillation crystal can be used with a moving coded-aperture mask to vary the detected count rate produced from radiation sources in the far field. The modulation of observed counts over time can be used to reconstruct an image with the known coded-aperture mask pattern. Current time-encoded imaging systems incorporate cylindrical coded-aperture masks and have limits to their fully coded imaging field-of-view. This work focuses on expanding the field-of-view to 4π by using a novel spherical coded-aperture mask. A regular icosahedron is used to approximate a spherical mask. This icosahedron consists of 20 equilateral triangles; the faces of which are each subdivided into four equilateral triangle-shaped voxels which are then projected onto a spherical surface, creating an 80-voxel coded-aperture mask. Furthermore, these polygonal voxels can be made from high-Z materials for gamma-ray modulation and/or low-Z materials for neutron modulation. In this work, we present Monte Carlo N-Particle (MCNP) simulations and simple models programmed in Mathematica to explore image reconstruction capabilities of this 80-voxel coded-aperture mask.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AWARE: The Atmospheric Radiation Measurement (ARM) West Antarctic Radiation Experiment

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) West Antarctic Radiation Experiment (AWARE) performed comprehensive meteorological and aerosol measurements and ground-based atmospheric remote sensing at two Antarctic stations using the most advanced instrumentation available. A suite of cloud research radars, lidars, spectral and broadband radiometers, aerosol chemical and microphysical sampling equipment, and meteorological instrumentation was deployed at McMurdo Station on Ross Island from December 2015 through December 2016. A smaller suite of radiometers and meteorological equipment, including radiosondes optimized for surface energy budget measurement, was deployed on the West Antarctic Ice Sheet between 4 December 2015 and 17 January 2016. AWARE provided Antarctic atmospheric data comparable to several well-instrumented high Arctic sites that have operated for many years and that reveal numerous contrasts with the Arctic in aerosol and cloud microphysical properties. These include persistent differences in liquid cloud occurrence, cloud height, and cloud thickness. Antarctic aerosol properties are also quite different from the Arctic in both seasonal cycle and composition, due to the continent’s isolation from lower latitudes by Southern Ocean storm tracks. Antarctic aerosol number and mass concentrations are not only non-negligible but perhaps play a more important role than previously recognized because of the higher sensitivities of clouds at the very low concentrations caused by the large-scale dynamical isolation. Antarctic aerosol chemical composition, particularly organic components, has implications for local cloud microphysics. The AWARE dataset, fully available online in the ARM Program data archive, offers numerous case studies for unique and rigorous evaluation of mixed-phase cloud parameterization in climate models.

54 ENVIRONMENTAL SCIENCES↗

Vertical Structure of Radiative Heating Rates of the MJO during DYNAMO

The vertical structure of radiative heating rates over the region of the tropi-cal Indian Ocean associated with the MJO during the DYNAMO/ARM MJO Investigation Experiment is presented. The mean and variability of heating rates during active, suppressed, and disturbed phases are determined from the Paci?c Northwest National Laboratory combined remote sensing retrieval (CombRet) from Gan Island, Maldives (0.69? S, 73.15? E). TOA and surface ?uxes from the CombRet product are compared with collocated three-hourly CERES SYN1deg Ed4A satellite retrievals. The ?uxes are correlated in time with correlation coef?cients around 0.9, yet CombRet time-mean OLR is 15 W m-2 larger. Previous work has suggested that CombRet under-samples high clouds, due to attenuation by low-level clouds and reduced instrument sensitivity with altitude. However, mean OLR differs between CombRet and CERES for all values of OLR, not just the lowest values corresponding to widespread high clouds. The discrepancy peaks for mid-range OLR, sugges-tive of precipitating, towering cumulus convective clouds, rather than strati-form cirrus clouds. Biases in the cloud-top height of thick clouds substantially contribute to the overestimate of OLR by CombRet. CombRet data is used to generate composite shortwave and longwave atmospheric heating rate pro-?les as a function of the local OLR. Though there is considerable variability in CombRet not directly related to OLR, the time-height structure of mean heating rate composites generated using OLR as the interpolant is broadly representative of tropical convective variability on intraseasonal time scales.

Shell, Karen M.↗

Design and instrumentation for permanent magnet samples exposed to a radiation environment

This work is part of a larger program to study the effects of radiation on permanent magnets in an accelerator environment. In order to be sure that the permanent magnet samples are accurately placed, measured, and catalogued we have developed a system of sample racks, holders and measuring apparatuses. We have combined these holders and measurement racks with electronics to allow a single computer to catalogue the position and intensity of the magnet measurements. We outline the design of the apparatus, the collection software, and the methodology we will use to collect the data.

Accelerator Physics↗

Status of permanent magnet radiation resiliency studies at CEBAF

An ongoing investigation for the future of Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) lies in upgrading its maximum nominal energy using Fixed-Field Alternating-gradient (FFA) technology for its recirculating arcs, using permanent magnets for the FFA arcs. A common concern among the community is the degradation of these permanent magnets during operation due to the radiation environment in which they will be present. This work, funded by a Laboratory Directed R&D grant, aims to measure the permanent magnet degradation in the CEBAF tunnel enclosure, and extrapolate to the energies expected from the upgrade. We present the latest results of this study, as well as plans moving forward.

Accelerator Physics↗

Evaluating Use of the NASA Nowcastof Atmospheric Ionizing Radiation for Aviation Safety (NAIRAS) System for Verifying/Validating AMS Cosmic Background Radiation Measurements, RSLA-006-20, Year 1

This presentation will be presented at FY 2020 SDRD Annual (Webex) Meeting scheduled for September 23–24, 2020. Evaluating Use of the NASA Nowcastof Atmospheric Ionizing Radiation for Aviation Safety (NAIRAS) System for Verifying/Validating AMS Cosmic Background Radiation Measurements, RSLA-006-20, Year 1

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Partnership for Radiation Studies (PaRS): A Consortium for Advancing Radiation Science among Underrepresented STEM Students

The Partnership for Radiation Studies (PaRS) consortium was recently awarded by U.S. Department of Energy’s National Nuclear Security Administration (NNSA). The five-year grant aims to increase the number of underrepresented students in STEM disciplines, with simultaneous advancement of nuclear radiation science. The goal is to hire more underrepresented minorities at national laboratories. The consortium’s progress will be tracked/reported annually. This paper and subsequent presentation cover details of the consortium, highlighting the key activities of participating national laboratories in assisting the minority-serving institutions.

Minority Serving Institutions Partnership Program,↗

Pneumonia After Bacterial or Viral Infection Preceded or Followed by Radiation Exposure: A Reanalysis of Older Radiobiologic Data and Implications for Low-Dose Radiation Therapy for Coronavirus Disease 2019 Pneumonia

Currently, there are about 15 ongoing clinical studies on low dose radiation therapy for Coronavirus Disease 2019 pneumonia. One of the underlying assumptions is that irradiation of 0.5 to 1.5 Gy is effective at ameliorating viral pneumonia. We aimed to reanalyze all available experimental radiobiologic data to assess evidence for such amelioration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Clinical Cell-Cycle Risk (CCR) score Is Associated With Metastasis After Radiation Therapy and Provides Guidance on When to Forgo Combined Androgen Deprivation Therapy With Dose-Escalated Radiation

The clinical cell-cycle risk (CCR) score, which combines the University of California, San Francisco's Cancer of the Prostate Risk Assessment (CAPRA) and the cell cycle progression (CCP) molecular score, has been validated to be prognostic of disease progression for men with prostate cancer. This study evaluated the ability of the CCR score to prognosticate the risk of metastasis in men receiving dose-escalated radiation therapy (RT) with or without androgen deprivation therapy (ADT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Radiation-Induced and High-Field Electrically Stress-Induced Interface Defects in Si/SiO 2 MOSFETs via Electrically Detected Magnetic Resonance

Here, we utilize electrically detected magnetic resonance (EDMR) measurements to compare high-field stressed, and gamma irradiated Si/SiO 2 metal–oxide–silicon (MOS) structures. We utilize spin-dependent recombination (SDR) EDMR detected using the Fitzgerald and Grove dc I-V approach to compare the effects of high-field electrical stressing and gamma irradiation on defect formation at and near the Si/SiO 2 interface. As anticipated, both greatly increase the concentration of P b centers (silicon dangling bonds at the interface) densities. The irradiation also generated a significant increase in the dc I-V EDMR response of E' centers (oxygen vacancies in the SiO 2 films), whereas the generation of an E' EDMR response in high-field stressing is much weaker than in the gamma irradiation case. These results likely suggest a difference in their physical distribution resulting from radiation damage and high electric field stressing.

42 ENGINEERING↗