Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiative cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Performance analysis of radiation cooled dc transmission lines for high power space systems

As space power levels increase to meet mission objectives and also as the transmission distance between power source and load increases, the mass, volume, power loss, and operating voltage and temperature become important system design considerations. This analysis develops the dependence of the specific mass and percent power loss on the power and voltage levels, transmission distance, operating temperature and conductor material properties. Only radiation cooling is considered since the transmission line is assumed to operate in a space environment. The results show that the limiting conditions for achieving low specific mass, percent power loss, and volume for a space-type dc transmission line are the permissible transmission voltage and operating temperature. Other means to achieve low specific mass include the judicious choice of conductor materials. The results of this analysis should be immediately applicable to power system trade-off studies including comparisons with ac transmission systems.

Schwarze, G. E.↗

A Regulation of Tropical Climate by Radiative Cooling as Simulated in a Cumulus Ensemble Model

Responses of tropical atmosphere to low-boundary forcing are investigated in a 2-D cumulus ensemble model (CEM) with an imposed warm-pool and cold-pool SST contrast (deltaSST). The domain-mean vertical motion is constrained to produce heat sink and moisture source as in the observed tropical climate. In a series of experiments, the warm pool SST is specified at different values while the cold pool SST is specified at 26 C. The strength of the circulation increases with increasing deltaSST until deltaSST reaches 3.5 C, and remains unchanged as deltaSST exceeds 3.5 C. The regulation of tropical convection by zonal SST gradient is constrained by the radiative cooling over the cold pool. For deltaSST less than 3.5 C, an enhanced subsidence warming is balanced by a reduced condensation heating over the cold pool. For deltaSST greater than 3.5 C, the subsidence regime expands over the entire cold pool where no condensation heating exist so that a further enhanced subsidence warming can no longer be sustained. The above regulation mechanism is also evident in the change of energy at the top of the atmosphere (TOA) that is dominated by cloud and water vapor greenhouse effect (c (sub LW)) and G (sub clear). The change in shortwave radiation at TOA is largely cancelled between the warm pool and cold pool, likely due to the same imposed vertical motion in our experiments. For deltaSST less than 3.5 C, an increase of deltaSST is associated with a large increase in c (sub Lw) due to increased total clouds in response to enhanced SST-induced circulation. For deltaSST greater than 3.5 C, clouds over the warm pool decrease with increasing SST, and the change in c (sub LW) is much smaller. In both dSST regimes, the change in CLW is larger than the change in G(sub clear) which is slightly negative. However, in the case of uniform warming (deltaSST=0), DeltaG(sub clear), is positive, approximately 5 W per square meters per degree change of SST.

Sui, Chung-Hsiung↗

A Method Based on Radiative Cooling for Detecting Structural Changes in Undercooled Metallic Liquids

We introduce a structure-sensitive parameter for undercooled melts which can be measured in containerless processing experiments. We have established that the ratio, R(T), of hemispherical total emissivity epsilon(sub T)(T) to constant-pressure specific heat c(sub p)(T) can serve as an indicator which is sensitive to any changes in short range atomic order in undercooled metallic melts. R(T) (triple bonds) epsilon(sub T)(T)/c(sub p)(T) values for nickel, zirconium, and silicon have been obtained using the high temperature electrostatic levitator while the levitated melts were undergoing purely radiative cooling into the deeply undercooled region. R(T) plots for undercooled liquid nickel and zirconium indicate no significant change in short-range structure from their melting temperatures to 15% undercooling. In contrast, liquid silicon shows marked short-range structural changes beginning above its melting temperature and extending throughout the undercooled region. The short-range structure of liquid silicon is related to the highly-directional covalent bonding which characterizes its solid form. The nickel and zirconium data show that epsilon(sub T) varies linearly with T, in support of metal emissivity theories.

Rulison, Aaron J.↗

Thermal Design and Analysis of a Multi-Stage 30K Radiative Cooling System for EPIC

The Experimental Probe of Inflationary Cosmology (EPIC) is an implementation of the NASA Einstein Inflation Probe mission, to answer questions about the physics of Inflation in the early Universe by measuring the polarization of the Cosmic Microwave Background (CMB). The mission relies on a passive cooling system to cool the enclosure of a telescope to 30 K; a cryocooler then cools this enclosure to 18 K and the telescope to 4 K. Subsequently, an adiabatic demagnetization refrigerator further cools a large focal plane to approx.100 mK. For this mission, the telescope has an aperture of 1.4 m, and the spacecraft's symmetry axis is oriented approx. 45 degrees relative to the direction of the sun. The spacecraft will be spun at approx. 0.5 rpm around this axis, which then precesses on the sky at 1 rph. The passive system must both supply the necessary cooling power for the cryocooler and meet demanding temperature stability requirements. We describe the thermal design of a passive cooling system consisting of four V-groove radiators for shielding of solar radiation and cooling the telescope to 30 K. The design realizes loads of 20 and 68 mW at the 4 K and 18 K stages on the cooler, respectively. A lower cost option for reaching 40 K with three V-groove radiators is also described. The analysis includes radiation coupling between stages of the radiators and sunshields, and parasitic conduction in the bipod support, harnesses, and ADR leads. Dynamic effects are also estimated, including the very small variations in temperature due to the scan motion of the spacecraft.

Space↗

Investigation in the 7-By-10 Foot Wind Tunnel of Ducts for Cooling Radiators Within an Airplane Wing, Special Report

An investigation was made in the NACA 7- by 10-foot wind tunnel of a large-chord wing model with a duct to house a simulated radiator suitable for a liquid-cooled engine. The duct was expanded to reduce the radiator losses, and the installation of the duct and radiator was made entirely within the wing to reduce form and interference drag. The tests were made using a two-dimensional flow set-up with a full-span duct and radiator. Section aerodynamic characteristics of the basic airfoil are given and also curves showing the characteristics of the various duct-radiator combinations. An expression for efficiency, the primary criterion of merit of any duct, and the effect of the several design parameters of the duct-radiator arrangement are discussed. The problem of throttling is considered and a discussion of the power required for cooling is included. It was found that radiators could be mounted in the wing and efficiently pass enough air for cooling with duct outlets located at any point from 0.25c to 0.70c from the wing leading edge on the upper surface. The duct-inlet position was found to be critical and, for maximum efficiency, had to be at the stagnation point of the airfoil and to change with flight attitude. The flow could be efficiently throttled only by a simultaneous variation of duct inlet and outlet sizes and of inlet position. It was desirable to round both inlet and outlet lips. With certain arrangements of duct, the power required for cooling at high speed was a very low percentage of the engine power.

Harris, Thomas A.↗

Investigation in the 7-by-10 Foot Wind Tunnel of Ducts for Cooling Radiators within an Airplane Wing

Report presents the results of an investigation made in the NACA 7 by 10-foot wind tunnel of a large-chord wing model with a duct to house a simulated radiator suitable for a liquid-cooled engine. The duct was expanded to reduce the radiator losses, and the installation of the duct and radiator was made entirely within the wing to reduce form and interference drag. The tests were made using a two-dimensional-flow setup with a full-span duct and radiator. Section aerodynamic characteristics of the basic airfoil are given and also curves showing the characteristics of the various duct-radiator combinations. An expression for efficiency, the primary criterion of merit of any duct, and the effect of the several design parameters of the duct-radiator arrangement are discussed. The problem of throttling is considered and a discussion of the power required for cooling is included.

Harris, Thomas A↗

Transient radiative cooling of a droplet-filled layer

A proposed lightweight radiator system for waste heat dissipation in space would eject streams of coolant in the form of small, hot liquid droplets. The droplets would lose radiative energy by direct exposure to the very low-temperature environment of space, and would then be collected for reuse. The cooling behavior of a layer composed of many small droplets was studied by numerical solution of the radiative integral equations. Since there is mutual interference for radiative energy dissipation, an array droplet will cool more slowly than if each drop is exposed individually. Since liquid metal droplets may be used, the study includes results for conditions with high scattering. For optically thin regions, especially with high scattering, the temperature distribution is sufficiently uniform that the cooling can be computed using the approximation of a constant layer emittance. For optically thick layers starting at uniform temperature, the temperature distributions become nonuniform with time. It was found that the cooling process goes through a starting transient; a constant emittance condition is then achieved where the emittance is lower than that for a layer at uniform temperature.

Siegel, R.↗

Theory and Apparatus for Measurement of Emissivity for Radiative Cooling of Hypersonic Aircraft with Data for Inconel and Inconel X

The importance of radiation as a means of cooling high-supersonic- and hypersonic-speed aircraft is discussed to show the need for measurements of the total hemispherical emissivity of surfaces. The theory underlying the measurement of the total hemispherical emissivity of surfaces is presented, readily duplicable apparatus for performing the measurements is described, and measurements for stably oxidized Inconel and Inconel X are given for the temperature range from 600 F to 2,000 F.

MATERIALS, PROPERTIES - THERMAL↗

Observations of the Earth's Radiation Budget in relation to atmospheric hydrology. 4: Atmospheric column radiative cooling over the world's oceans

This paper introduces a simple method for deriving climatological values of the longwave flux emitted from the clear sky atmosphere to the ice-free ocean surface. It is shown using both theory and data from simulations how the ratio of the surface to top-of-atmosphere (TOA) flux is a simple function of water vapor (W) and a validation of the simple relationship is presented based on a limited set of surface flux measurements. The rms difference between the retrieved surface fluxes and the simulated surface fluxes is approximately 6 W/sq m. The clear sky column cooling rate of the atmosphere is derived from the Earth Radiation Budget Experiment (ERBE) values of the clear sky TOA flux and the surface flux retrieved using Special Scanning Microwave Imager (SSM/I) measurements of w together with ERBE clear sky fluxes. The relationship between this column cooling rate, w, and the sea surface temperature (SST) is explored and it is shown how the cooling rate systematically increases as both w and SST increase. The uncertainty implied in these estmates of cooling are approximately +/- 0.2 K/d. The effects of clouds on this longwave cooling are also explored by placing bounds on the possible impact of clouds on the column cooling rate based on certain assumptions about the effect of clouds on the longwave flux to the surface. It is shown how the longwave effects of clouds in a moist atmosphere where the column water vapor exceeds approximately 30 kg/sq m may be estimated from presently available satellite data with an uncertainty estimated to be approximately 0.2 K/d. Based on an approach described in this paper, we show how clouds in these relatively moist regions decrease the column cooling by almost 50% of the clear sky values and the existence of significant longitudinal gradients in column radiative heating across the equatorial and subtropical Pacific Ocean.

Stephens, Graeme L.↗

Emittance bounds for transient radiative cooling of a scattering rectangular region

Transient cooling was analyzed for a two-dimensional gray rectangular region that emits, absorbs, and isotropically scatters radiation. The region, initially at uniform temperature, is placed in surroundings at a much lower temperature. The cooling analysis yields two simultaneous equations for the transient temperature and scattering source function distributions. The region starts to cool with the medium at uniform temperature. For this condition, the local emittance around the perimeter was obtained by a numerical solution of the radiative equations, and the rate of heat loss from the entire medium was evaluated. As cooling continues, the emissive ability decreases because of the lower temperatures in the outer regions of the rectangle. Based on some previous work, a lower limit for the transient overall emittance was found by obtaining a similarity solution. For some ranges of optical thickness and scattering albedo, the lower limit is only a small amount below the initial emittance. For these conditions, the initial emittance can be used to compute the entire transient resulting in a considerable simplification.

Siegel, Robert↗

Radiative cooling of a solidifying droplet layer including absorption and scattering

A simple solution for the transient cooling of a solidifying layer filled with drops that can emit and scatter radiation is discussed, with application to a liquid drop radiator proposed for the Space Station (Mattick and Hertzberg, 1981). The layer remains at uniform temperature during solidification, and the outer portions rapidly lose heat, producing a variation along the length of the layer in the distribution of liquid concentration across the layer. The analysis is used to obtain both the amount of energy dissipated by the two-phase system at uniform temperature and the velocity distribution necessary to maintain a uniform liquid fraction across the entire layer at all locations along the layer length.

Siegel, Robert↗

Radiative cooling of a layer with nonuniform velocity - A separable solution

Analyzed here is the cooling of a flowing plane layer filled with hot particles or liquid droplets that emit, absorb, and scatter radiation. The velocity distribution is nonuniform across the layer and the specified shape of this distribution affects the layer temperature distribution and emittance. The velocity distribution determined is one that will cause the layer to cool at a uniform temperature. Thus, if the layer initially has a uniform temperature, it will retain the same emittance throughout its length. A separable solution is found that applies in a 'fully developed' region following an initial cooling length. In this developed region, the solution shows that there is a constant emittance based on the local heat loss and local bulk mean layer temperature. This emittance is a function of the velocity distribution, optical thickness, and scattering albedo.

Siegel, Robert↗

Transient radiative cooling of an absorbing and scattering cylinder

The transient cooling of an absorbing, emitting, and scattering cylinder is studied by using the forward integration of energy transfer equations. The analysis presented here provides cooling curves for a cylindrical region, initially at uniform temperature and then suddenly exposed to a much cooler environment. Results are presented for several optical radii and different values of the scattering albedo.

Siegel, R.↗

Combustion interaction with radiation-cooled chambers

Over 15 hours of thruster operation at temperatures between 1916 and 2246 C without failure or erosion has been demonstrated using iridium-coated rhenium chamber materials with nitrogen tetroxide/monomethylhydrazine propellants operating over a mixture ratio range of 1.60-2.05. Research is now under way to provide a basic understanding of the mechanisms which make high-temperature operation possible and to extend the capability to a wider range of conditions, including other propellant combinations and chamber materials. Techniques have been demonstrated for studying surface fracture phenomena. These include surface Raman and Auger for study of oxide formation, surface Raman and X-ray diffraction to determine the oxide phase, Auger to study oxide stoichiometry, and sputter Auger to study interdiffusion of alloy species.

Rosenberg, S. D.↗

The Stability of Radiatively Cooling Jets. 2: Nonlinear Evolution

We use two-dimensional time-dependent hydrodynamical simulations to follow the growth of the Kelvin-Helmholtz (K-H) instability in cooling jets into the nonlinear regime. We focus primarily on asymmetric modes that give rise to transverse displacements of the jet beam. A variety of Mach numbers and two different cooling curves are studied. The growth rates of waves in the linear regime measured from the numerical simulations are in excellent agreement with the predictions of the linear stability analysis presented in the first paper in this series. In the nonlinear regime, the simulations show that asymmetric modes of the K-H instability can affect the structure and evolution of cooling jets in a number of ways. We find that jets in which the growth rate of the sinusoidal surface wave has a maximum at a so-called resonant frequency can be dominated by large-amplitude sinusoidal oscillations near this frequency. Eventually, growth of this wave can disrupt the jet. On the other hand, nonlinear body waves tend to produce low-amplitude wiggles in the shape of the jet but can result in strong shocks in the jet beam. In cooling jets, these shocks can produce dense knots and filaments of cooling gas within the jet. Ripples in the surface of the jet beam caused by both surface and body waves generate oblique shock "spurs" driven into the ambient gas. Our simulations show these shock "spurs" can accelerate ambient gas at large distances from the jet beam to low velocities, which represents a new mechanism by which low-velocity bipolar outflows may be driven by high-velocity jets. Rapid entrainment and acceleration of ambient gas may also occur if the jet is disrupted. For parameters typical of protostellar jets, the frequency at which K-H growth is a maximum (or highest frequency to which the entire jet can respond dynamically) will be associated with perturbations with a period of - 200 yr. Higher frequency (shorter period) perturbations excite waves associated with body modes that produce internal shocks and only small-amplitude wiggles within the jet. The fact that most observed systems show no evidence for large-amplitude sinusoidal oscillation leading to disruption is indicative that the perturbation frequencies are generally large, consistent with the suggestion that pro- tostellar jets arise from the inner regions (r less than 1 AU) of accretion disks.

Stone, James M.↗