Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation dosimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fundamentals of Aerospace Medicine: Cosmic Radiation

Cosmic rays were discovered in 1911 by the Austrian physicist, Victor Hess. The planet earth is continuously bathed in high-energy galactic cosmic ionizing radiation (GCR), emanating from outside the solar system, and sporadically exposed to bursts of energetic particles from the sun referred to as solar particle events (SPEs). The main source of GCR is believed to be supernovae (exploding stars), while occasionally a disturbance in the sun's atmosphere (solar flare or coronal mass ejection) leads to a surge of radiation particles with sufficient energy to penetrate the earth's magnetic field and enter the atmosphere. The inhabitants of planet earth gain protection from the effects of cosmic radiation from the earth s magnetic field and the atmosphere, as well as from the sun's magnetic field and solar wind. These protective effects extend to the occupants of aircraft flying within the earth s atmosphere, although the effects can be complex for aircraft flying at high altitudes and high latitudes. Travellers in space do not have the benefit of this protection and are exposed to an ionizing radiation field very different in magnitude and quality from the exposure of individuals flying in commercial airliners. The higher amounts and distinct types of radiation qualities in space lead to a large need for understanding the biological effects of space radiation. It is recognized that although there are many overlaps between the aviation and the space environments, there are large differences in radiation dosimetry, risks and protection for airline crew members, passengers and astronauts. These differences impact the application of radiation protection principles of risk justification, limitation, and the principle of as low as reasonably achievable (ALARA). This chapter accordingly is divided into three major sections, the first dealing with the basic physics and health risks, the second with the commercial airline experience, and the third with the aspects of cosmic radiation appertaining to space travel including future considerations.

Bagshaw, Michael↗

Cosmic Radiation Dose Measurements from the RaD-X Flight Campaign

The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission obtained measurements for improving the understanding of cosmic radiation transport in the atmosphere and human exposure to this ionizing radiation field in the aircraft environment. The value of dosimetric measurements from the balloon platform is that they can be used to characterize cosmic ray primaries, the ultimate source of aviation radiation exposure. In addition, radiation detectors were flown to assess their potential application to long-term, continuous monitoring of the aircraft radiation environment. The RaD-X balloon was successfully launched from Fort Sumner, New Mexico (34.5 degrees North, 104.2 degrees West) on 25 September 2015. Over 18 hours of flight data were obtained from each of the four different science instruments at altitudes above 20 kilometers. The RaD-X balloon flight was supplemented by contemporaneous aircraft measurements. Flight-averaged dosimetric quantities are reported at seven altitudes to provide benchmark measurements for improving aviation radiation models. The altitude range of the flight data extends from commercial aircraft altitudes to above the Pfotzer maximum where the dosimetric quantities are influenced by cosmic ray primaries. The RaD-X balloon flight observed an absence of the Pfotzer maximum in the measurements of dose equivalent rate.

Mertens, Christopher J.↗

Verification of Dosimetry Measurements with Timepix Pixel Detectors for Space Applications

The current capabilities of modern pixel-detector technology has provided the possibility to design a new generation of radiation monitors. Timepix detectors are semiconductor pixel detectors based on a hybrid configuration. As such, the read-out chip can be used with different types and thicknesses of sensors. For space radiation dosimetry applications, Timepix devices with 300 and 500 microns thick silicon sensors have been used by a collaboration between NASA and University of Houston to explore their performance. For that purpose, an extensive evaluation of the response of Timepix for such applications has been performed. Timepix-based devices were tested in many different environments both at ground-based accelerator facilities such as HIMAC (Heavy Ion Medical Accelerator in Chiba, Japan), and at NSRL (NASA Space Radiation Laboratory at Brookhaven National Laboratory in Upton, NY), as well as in space on board of the International Space Station (ISS). These tests have included a wide range of the particle types and energies, from protons through iron nuclei. The results have been compared both with other devices and theoretical values. This effort has demonstrated that Timepix-based detectors are exceptionally capable at providing accurate dosimetry measurements in this application as verified by the confirming correspondence with the other accepted techniques.

Kroupa, M.↗

Radiation calculations and comparisons with data

In conjunction with the analysis of data from the Long Duration Exposure Facility (LDEF) ionizing radiation dosimetry, a calculation program was established to aid in data interpretation and to assess the accuracy of current radiation environments and effects models for future mission applications. Initial estimates of LDEF exposure to trapped, galactic, and atmospheric (albedo) radiation sources were made, and the radiation environment (primary and secondary particle spectra) and several radiation effects (induced radioactivity and dose) for varying amounts of LDEF shielding were calculated for a simplified LDEF mass model. Preliminary comparisons of the calculated results were made with the induced radioactivity measurements for several LDEF parts and with preliminary dose data from several experiments (P0004, P0006, and M0004). Predictions were compared with the radioactivity induced in the aluminum clamps holding the experiment trays and in the stainless steel trunnions to test a recently developed theory of trapped proton anisotropy.

Armstrong, T. W.↗

Efficiency of a radiophotoluminescence glass dosemeter for low-earth-orbit space radiation

Chips of a radiophotoluminescence glass dosemeter (RPLG) were used for measurements of space radiation during a 9.8 d Shuttle-Mir mission (STS-91) at an altitude of 400 km and an inclination of 51.65 degrees. Two of RPLG chips were put into each of 59 positions in or on a life-size human phantom. The RPLG values equivalent to 137Cs gamma ray absorbed doses were found to be systematically lower than those of a Mg2SiO4:Tb thermoluminescence dosemeter (TDMS). In comparison with the organ or tissue absorbed dose and dose equivalent values that were estimated using a combination of TDMS and plastic nuclear track detectors, the efficiencies of the RPLG chips were about 80% for the water absorbed dose and about 40% for the dose equivalent. Whereas the percentage values will change during different missions, such additional information obtained from small RPLG chips is useful for improving the reliability of radiation dosimetry in space.

NASA Discipline Radiation Health↗

Geometry and mass model of ionizing radiation experiments on the LDEF satellite

Extensive measurements related to ionizing radiation environments and effects were made on the LDEF satellite during its mission lifetime of almost 6 years. These data, together with the opportunity they provide for evaluating predictive models and analysis methods, should allow more accurate assessments of the space radiation environment and related effects for future missions in low Earth orbit. The LDEF radiation dosimetry data is influenced to varying degrees by material shielding effects due to the dosimeter itself, nearby components and experiments, and the spacecraft structure. A geometry and mass model is generated of LDEF, incorporating sufficient detail that it can be applied in determining the influence of material shielding on ionizing radiation measurements and predictions. This model can be used as an aid in data interpretation by unfolding shielding effects from the LDEF radiation dosimeter responses. Use of the LDEF geometry/mass model, in conjunction with predictions and comparisons with LDEF dosimetry data currently underway, will also allow more definitive evaluations of current radiation models for future mission applications.

Colborn, B. L.↗

The Rapid Response Radiation Survey (R3S) Mission Using the HiSat Conformal Satellite Architecture

The Rapid Response Radiation Survey (R3S) experiment, designed as a quick turnaround mission to make radiation measurements in Low Earth Orbit (LEO), will fly as a hosted payload in partnership with NovaWurks using their Hyper-integrated Satlet (HISat) architecture. The need for the mission arises as the Nowcast of Atmospheric Ionization Radiation for Aviation Safety (NAIRAS) model moves from a research effort into an operational radiation assessment tool. Currently, airline professionals are the second largest demographic of radiation workers and to date their radiation exposure is undocumented in the USA. The NAIRAS model seeks to fill this information gap. The data collected by R3S, in addition to the complementary data from a NASA Langley Research Center (LaRC) atmospheric balloon mission entitled Radiation Dosimetry Experiment (RaD-X), will validate exposure prediction capabilities of NAIRAS. The R3S mission collects total dose and radiation spectrum measurements using a Teledyne μDosimeter and a Liulin-6SA2 LED spectrometer. These two radiation sensors provide a cross correlated radiometric measurement in combination with the Honeywell HMR2300 Smart Digital Magnetometer. The magnetometer assesses the Earth's magnetic field in the LEO environment and allows radiation dose to be mapped as a function of the Earth's magnetic shielding. R3S is also unique in that the radiation sensors will be exposed on the outer surface of the spacecraft, possibly making this the first measurements of the LEO radiation environment with bare sensors. Viability of R3S as an extremely fast turnaround mission is due, in part, to the nature of the robust, well-defined interfaces of the conformal satellite HiSat Architecture. The HiSat architecture, which was developed with the support of the Defense Advanced Research Projects Agency's (DARPA's) Phoenix Program, enabled the R3S system to advance from the first concept to delivery of preliminary design review (PDR) level documents in 29 calendar days. The architecture allows for interface complexities between the specific devices and the satellite bus to be resolved in a standardized interface control document (ICD). The ICD provided a readymade framework to interface to the modular satellite bus. This modularity allowed for approximately 90% of the R3S system to be designed and fabricated in two months without constraint of the hosting satellite's development cycle. This paper discusses the development of the R3S experiment as made possible by use of the HiSat architecture. The system design and operational modes of the experiment are described, as well as the experiment interfaces to the HiSat satellite via the user defined adapter (UDA) provided by NovaWurks. This paper outlines the steps taken by the project to execute the R3S mission in the 4 months of design, build, and test. Additionally portrayed is the ground work done at LaRC to posture the organization for a fast response and the process by which the opportunity was identified as aligning with key strategic goals. Finally, a description of the engineering process is provided, including the use of facilitated rapid/concurrent engineering sessions, the associated documentation, and the review process employed.

Miller, Nathanael A.↗

Ionizing radiation calculations and comparisons with LDEF data

In conjunction with the analysis of LDEF ionizing radiation dosimetry data, a calculational program is in progress to aid in data interpretation and to assess the accuracy of current radiation models for future mission applications. To estimate the ionizing radiation environment at the LDEF dosimeter locations, scoping calculations for a simplified (one dimensional) LDEF mass model were made of the primary and secondary radiations produced as a function of shielding thickness due to trapped proton, galactic proton, and atmospheric (neutron and proton cosmic ray albedo) exposures. Preliminary comparisons of predictions with LDEF induced radioactivity and dose measurements were made to test a recently developed model of trapped proton anisotropy.

Armstrong, T. W.↗

Future directions for LDEF ionizing radiation modeling and assessments

A calculational program utilizing data from radiation dosimetry measurements aboard the Long Duration Exposure Facility (LDEF) satellite to reduce the uncertainties in current models defining the ionizing radiation environment is in progress. Most of the effort to date has been on using LDEF radiation dose measurements to evaluate models defining the geomagnetically trapped radiation, which has provided results applicable to radiation design assessments being performed for Space Station Freedom. Plans for future data comparisons, model evaluations, and assessments using additional LDEF data sets (LET spectra, induced radioactivity, and particle spectra) are discussed.

Armstrong, T. W.↗

Characterization of the RaD-X Mission Instruments

The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission, launched on 25 September 2015, provided dosimetric measurements above the Pfotzer maximum. The goal of taking these measurements is to improve aviation radiation models by providing a characterization of cosmic ray primaries, which are the source of radiation exposure at aviation altitudes. The RaD-X science payload consists of four instruments. The main science instrument is a tissue-equivalent proportional counter (TEPC). The other instruments consisted of three solid state silicon dosimeters: Liulin, Teledyne total ionizing dose (TID) and RaySure detectors. To properly interpret the measurements, it is necessary to evaluate how the payload affects the radiation environment of the detectors. In addition, it is necessary to evaluate how the detectors react to the different particles impacting them. We present the results of the Geant-4 simulations of the interaction of the different radiations with the payload and the instruments. We show how it affect the measurements, and which instruments are better suited for future missions

Gronoff, Guillaume↗

Assessment of the Influence of the RaD-X Balloon Payload on the Onboard Radiation Detectors

The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission, launched on 25 September 2015, provided dosimetric measurements above the Pfotzer maximum. The goal of taking these measurements is to improve aviation radiation models by providing a characterization of cosmic ray primaries, which are the source of radiation exposure at aviation altitudes. The RaD-X science payload consists of four instruments. The main science instrument is a tissue-equivalent proportional counter (TEPC). The other instruments consisted of three solid state silicon dosimeters: Liulin, Teledyne total ionizing dose (TID) and RaySure detectors. The instruments were housed in an aluminum structure protected by a foam cover. The structure partially shielded the detectors from cosmic rays but also created secondary particles, modifying the ambient radiation environment observed by the instruments. Therefore, it is necessary to account for the influence of the payload structure on the measured doses. In this paper, we present the results of modeling the effect of the balloon payload on the radiation detector measurements using a Geant-4 (GEometry ANd Tracking) application. Payload structure correction factors derived for the TEPC, Liulin, and TID instruments are provided as a function of altitude. Overall, the payload corrections are no more than a 7% effect on the radiation environment measurements.

Gronoff, Guilluame↗

Radiation model predictions and validation using LDEF data

Radiation dosimetry aboard LDEF, as well as post-flight measurements of the radioactivity induced in numerous LDEF spacecraft components, provide unique data for evaluating the accuracy of current models for predicting both the space radiation environments (trapped proton intensity, spectra, and directionality; cosmic ray fluence) and the radiation environments induced in spacecraft components (fluence, energy spectra, secondary particle, linear energy transfer, etc.). By determining the accuracy of such models using LDEF data, and with model updates where required, improved radiation environment predictions can be made for future missions, which in turn allows improved predictions for specific radiation effects for future spacecraft components (single event upsets of microelectronics, radiation damage to focal plane arrays, noise in sensitive instrumentation, etc.). Herein, the status and results from radiation model predictions and comparisons with LDEF data is given. The calculations are made using radiation transport codes coupled with a 3-D geometry/mass model of LDEF, together with current models of the space radiation environment.

Armstrong, T. W.↗

LDEF Satellite Radiation Analyses

Model calculations and analyses have been carried out to compare with several sets of data (dose, induced radioactivity in various experiment samples and spacecraft components, fission foil measurements, and LET spectra) from passive radiation dosimetry on the Long Duration Exposure Facility (LDEF) satellite, which was recovered after almost six years in space. The calculations and data comparisons are used to estimate the accuracy of current models and methods for predicting the ionizing radiation environment in low earth orbit. The emphasis is on checking the accuracy of trapped proton flux and anisotropy models.

Armstrong, T. W.↗

GeneLab: A Systems Biology Platform for Omics Analysis

NASA GeneLab is an open-access repository for omics datasets generated by biological experiments conducted in space or experiments relevant to spaceflight (e.g. simulated cosmic radiation, simulated microgravity, bed rest studies). The GeneLab Data Systems (GLDS) version 4.0 will be available on October 1st 2019, and will provide the latest in terms of professional state-of-the-art bioinformatics platform for the space biology and radiation community to upload their data into an omics data commons, to process their data with vetted standard workflows and to compare to existing analyses. Started in 2015 as a repository designed to archive omics data from space experiments, GeneLab has expanded its scope to all ionizing radiation omics experiments conducted on the ground and has put considerable effort in providing carefully characterized radiation metadata on all dataset. GeneLab is also providing processed data derived from the raw data covering a large spectrum of omics (genome, epigenome, transcriptome, epitranscriptome, proteome, metabolome) to help users explore important questions: 1) Which genes or proteins are expressed differently in space for various living organisms? 2) What specific DNA mutations or epigenetic changes happen in space or after exposure to ionizing radiation? and 3) How does genetics affect these responses? Processed data available on GeneLab are derived by standard data analysis workflows vetted by hundreds of scientists who volunteered to join one of the four GeneLab Analysis Working Groups (Animal AWG, Plant AWG, Microbe AWG, Multi-Omics AWG). In this presentation, we will discuss how to bridge the gap between irradiation studies performed on earth and biological experiments conducted in space since the early 1990's. We will discuss how radiation dosimetry was estimated for datasets derived from samples collected during the Space Shuttle era or on the International Space Station. Finally, we will address future strategies regarding dose monitoring in future missions into space, inter-agency efforts to unify data under one umbrella, and knowledge dissemination across the radiation research community and the space biology community.

open-science↗

NASA GeneLab Space Omics Database: Expanding from Space to Ionizing Radiation Data on the Ground

NASA GeneLab is an open-access repository for omics datasets generated by biological experiments conducted in space or ground experiments relevant to spaceflight (e.g. simulated cosmic radiation, simulated microgravity, bed rest studies). The GeneLab Data Systems (GLDS) version 4.0 will be available on October 1st 2019, and will provide a state-of-the-art bioinformatics platform for the space biology and radiation communities to upload their data into an omics data commons, to process their data with vetted standard workflows and to compare with existing analyses. Started in 2015 as a repository designed to archive omics data from space experiments, GeneLab has expanded its scope to all ionizing radiation omics experiments conducted on the ground and has put considerable effort in providing carefully characterized radiation metadata on all datasets. GeneLab is also providing processed data derived from the raw data covering a large spectrum of omics (genome, epigenome, transcriptome, epitranscriptome, proteome, metabolome) to help users explore important questions: 1) Which genes or proteins are expressed differently in space for various living organisms? 2) What specific DNA mutations or epigenetic changes happen in space or after exposure to ionizing radiation? and 3) How does genetics affect these responses? Processed data available on GeneLab are derived by standard data analysis workflows vetted by hundreds of scientists who volunteered to join one of the four GeneLab Analysis Working Groups (Animal AWG, Plant AWG, Microbe AWG, Multi-Omics AWG). In this presentation, we will discuss how to bridge the gap between irradiation studies performed on earth and biological experiments conducted in space since the early 1990's. We will discuss how radiation dosimetry was estimated for datasets derived from samples collected during the Space Shuttle era on the International Space Station and on other orbiting platforms. Finally, we will address future strategies regarding dose monitoring in future missions into space, inter-agency efforts to unify data under one umbrella, and knowledge dissemination across the radiation research community and the space biology community.

open-science↗

The emulsion chamber technology experiment

Photographic emulsion has the unique property of recording tracks of ionizing particles with a spatial precision of 1 micron, while also being capable of deployment over detector areas of square meters or 10's of square meters. Detectors are passive, their cost to fly in Space is a fraction of that of instruments of similar collecting. A major problem in their continued use has been the labor intensiveness of data retrieval by traditional microscope methods. Two factors changing the acceptability of emulsion technology in space are the astronomical costs of flying large electronic instruments such as ionization calorimeters in Space, and the power and low cost of computers, a small revolution in the laboratory microscope data-taking. Our group at UAH made measurements of the high energy composition and spectra of cosmic rays. The Marshall group has also specialized in space radiation dosimetry. Ionization calorimeters, using alternating layers of lead and photographic emulsion, to measure particle energies up to 10(exp 15) eV were developed. Ten balloon flights were performed with them. No such calorimeters have ever flown in orbit. In the ECT program, a small emulsion chamber was developed and will be flown on the Shuttle mission OAST-2 to resolve the principal technological questions concerning space exposures. These include assessments of: (1) pre-flight and orbital exposure to background radiation, including both self-shielding and secondary particle generation; the practical limit to exposure time in space can then be determined; (2) dynamics of stack to optimize design for launch and weightlessness; and (3) thermal and vacuum constraints on emulsion performance. All these effects are cumulative and affect our ability to perform scientific measurements but cannot be adequately predicted by available methods.

Gregory, John C.↗

NAIRAS Version 3 Atmospheric Ionizing Radiation Validation: Comparisons to RaD-X Measurements

The Nowcast of Aerospace Ionizing RAdiation System (NAIRAS) model predicts dosimetric and radiative flux quantities for assessing human radiation exposure levels and radiation effects on flight electronic systems from the surface of the Earth to deep space. NAIRAS version 3 includes many updates and improvements to the model. In this paper, NAIRAS version 3 dosimetric quantities are compared to observations of the atmospheric radiation environment taken during the Radiation Dosimetry Experiment (RaD-X) flight campaign. The RaD-X campaign consisted of a high-altitude balloon flight, with altitudes up to 40 km, and four coordinated aircraft flights covering an altitude range from 6-20 km. The RaD-X measurement data from the different flight platforms were acquired in September 2015 and at nearly the same vertical cutoff rigidity (3-4 GV). High quality, flight-averaged measurement data were provided at seven altitudes, which correspond to regions of fundamentally different radiation transport and collisional interaction physics. The NAIRAS model agrees with the RaD-X measurements to within 30% over the entire altitude domain of the flight campaign (0-40 km), which is within the measurement uncertainty.

Christopher J Mertens↗

Dosimetric and biological impact of activity extravasation of radiopharmaceuticals in PET imaging

The increasing use of nuclear medicine and PET imaging has intensified scrutiny of radiotracer extravasation. To our knowledge, this topic is understudied but holds great potential for enhancing our understanding of extravasation in clinical PET imaging. This work aims to (1) quantify the absorbed doses from radiotracer extravasation in PET imaging, both locally at the site of extravasation and with the extravasation location as a source of exposure to bodily organs and (2) assess the biological ramifications within the injection site at the cellular level. A radiation dosimetry simulation was performed using a whole-body 4D Extended Cardiac-Torso (XCAT) phantom embedded in the GATE Monte Carlo platform. A 10-mCi dose of 18 F-FDG was chosen to simulate a typical clinical PET scan scenario, with 10% of the activity extravasated in the antecubital fossa of the right arm of the phantom. The extravasation volume was modeled as a 5.5 mL rectangle in the hypodermal layer of skin. Absorbed dose contributions were calculated for the first two half-lives, assuming biological clearance thereafter. Dose calculations were performed as absorbed doses at the organ and skin levels. Energy deposition was simulated both at the local extravasation site and in multiple organs of interest and converted to absorbed doses based on their respective masses. Each simulation was repeated ten times to estimate Monte Carlo uncertainties. Biological impacts on cells within the extravasated volume were evaluated by randomizing cells and exposing them to a uniform radiation source of 18 F and 68 Ga. Particle types, their energies, and direction cosines were recorded in phase space files using a separate Geant4 simulation to characterize their entry into the nucleus of the cellular volume. Subsequently, the phase space files were imported into the TOPAS-nBio simulation to assess the extent of DNA damage, including double-strand breaks (DSBs) and single-strand breaks (SSBs). Organ-level dosimetric estimations are presented for 18 F and 68 Ga radionuclides in various organs of interest. With 10% extravasation, the hypodermal layer of the skin received the highest absorbed dose of 1.32 ± 0.01 Gy for 18 F and 0.99 ± 0.01 Gy for 68 Ga. The epidermal and dermal layers received absorbed doses of 0.07 ± 0.01 Gy and 0.13 ± 0.01 Gy for 18 F, and 0.14 ± 0.01 Gy and 0.29 ± 0.01 Gy for 68 Ga, respectively. In the extravasated volume, 18 F caused an average absorbed dose per nucleus of 0.17 ± 0.01 Gy, estimated to result in 10.58 ± 0.50 DSBs and 268.11 ± 12.43 SSBs per nucleus. For 68 Ga, the absorbed dose per nucleus was 0.11 ± 0.01 Gy, leading to an estimated 6.49 ± 0.34 DSBs and 161.24 ± 8.12 SSBs per nucleus. Absorbed doses in other organs were on the order of micro-gray (µGy). The likelihood of epidermal erythema resulting from extravasation during PET imaging is low, as the simulated absorbed doses to the epidermis remain below the thresholds that trigger such effects. Moreover, the organ-level absorbed doses were found to be clinically insignificant across various simulated organs. The minimal DNA damage at the extravasation site suggests that long-term harm, such as radiation-induced carcinogenesis, is highly unlikely.

DNA strand breaks↗