A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Detectors for DHS Applications

Presentation to be presented during the 2021 ANS Virtual Meeting, Radiation Detection for Homeland Security Technical Session, on June 14, 2021 (https://www.ans.org/meetings/am2021/session/view-582/).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin-based detection of terahertz and sub-terahertz electromagnetic radiation

Systems and methods for spin-based detection of electromagnetic radiation at terahertz and sub-terahertz frequencies is provided. The detector can include a heterostructure, a magnetic field generator, and an electrical circuit. The heterostructure can include a first layer formed of an antiferromagnetic material (AFM) in contact with a second layer of a heavy metal (HM) or a topological insulator. The magnetic field generator can generate a magnetic field oriented approximately parallel to an easy axis of the first layer and approximately parallel to a propagation direction of electromagnetic radiation. The circuit can be in electrical communication with the second layer. The first layer can inject a spin current into the second layer in response to receipt of electromagnetic radiation having a sub-terahertz or terahertz frequency. The second layer can convert the injected spin current into a potential difference. The circuit can be configured to output a signal corresponding to the potential difference.

Shi, Jing↗

Confirming the absence of nuclear warheads via passive gamma-ray measurements

Arms-control agreements between the United States and Russia negotiated after the end of the Cold War have imposed limits on the number of deployed strategic nuclear weapons. Verification of these agreements has relied on onsite inspections, sometimes supported by radiation detection techniques to confirm the absence of a nuclear warhead when ambiguities arise. So far, these measurements have sought to detect neutron emissions associated with the presence of plutonium, but they would be inadequate for uranium devices. In an effort to offer instruments that could be used to confirm the absence of both plutonium and uranium weapons, here we propose an inspection system that uses only passive gamma radiation detection techniques. Such a system would be particularly valuable for next-generation arms-control agreements that limit total numbers of weapons and would involve containerized items in storage. We conducted extensive Monte Carlo simulations to support the development of a verification protocol and detection algorithm. Here, we demonstrate the viability of the technique using standard laboratory check sources and MCNP simulations for simplified configurations of special nuclear material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nuclear Science Symposium, 23rd, Scintillation and Semiconductor Counter Symposium, 15th, and Nuclear Power Systems Symposium, 8th, New Orleans, La., October 20-22, 1976, Proceedings

The volume includes papers on semiconductor radiation detectors of various types, components of radiation detection and dosimetric systems, digital and microprocessor equipment in nuclear industry and science, and a wide variety of applications of nuclear radiation detectors. Semiconductor detectors of X-rays, gamma radiation, heavy ions, neutrons, and other nuclear particles, plastic scintillator arrays, drift chambers, spark wire chambers, and radiation dosimeter systems are reported on. Digital and analog conversion systems, digital data and control systems, microprocessors, and their uses in scientific research and nuclear power plants are discussed. Large-area imaging and biomedical nucleonic instrumentation, nuclear power plant safeguards, reactor instrumentation, nuclear power plant instrumentation, space instrumentation, and environmental instrumentation are dealt with. Individual items are announced in this issue.

Wagner, L. J.↗

High fidelity ground deposition measurement with robots after explosive radiological dispersion

A team of scientists from the Remote Sensing Laboratory at Joint Base Andrews, Maryland, has assembled a remote-controlled robot to field a few sodium iodide scintillators of different size and shape 18″ above ground for measurement of ground deposition of gamma-emitting particles after an explosion of a radiological dispersal device. This system uses a high-precision differential GPS device with submeter accuracy for radiation mapping. The system is most useful in characterizing large-area contamination and detecting gamma radioactivity in invisible, submicron particulate debris deposited on the ground at surface level or embedded in subsurface up to 3″ deep. The system was assembled as part of a larger effort to integrate advanced radiological detection devices into autonomous or remote-controlled robotic systems to eliminate or minimize the need for emergency responders to enter areas that pose significant health and safety risks to humans following a major radiological incident or accident. Research into autonomous algorithms is required to develop automated robotic systems for radiological survey and characterization activities in highly contaminated areas. The scope of this project also includes developing communications pathways and supporting infrastructure capabilities for different types of robotic technologies. The expected result is an advanced autonomous robotic system with integrated radiation detection electronics that allows emergency response personnel to view data remotely and in real time for radiological emergency response and consequence management purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deployment of a double scatter system for directional detection of background neutron radiation

The detection of special nuclear materials (SNM) requires the understanding of nuclear signatures that allow the discrimination against background. In particular, understanding neutron background characteristics such as count rates and energies and their correlations with environmental conditions and surroundings of measurement locations is important in enhancing SNM detection capabilities. The Mobile Imager of Neutrons for Emergency Responders (MINER) was deployed for 8 weeks in downtown San Francisco (CA) to study such neutron background characteristics in an urban environment. Of specific interest was the investigation of the impact of surrounding buildings on the neutron background count rates and to answer the question whether buildings act as absorber of neutrons or as sources via the so-called ship effect. MINER consists of 16 liquid scintillator detector elements and can be operated as a neutron spectrometer, as a neutron imager, or simply as a counter of fast neutrons. As expected, the neutron background rate was found to be inversely proportional to the atmospheric pressure. In the energy range where MINER is most sensitive, approximately 1–10 MeV, it was found that the shape of the detected background spectrum is similar to that of a detected fission spectrum, indicating the limited discrimination power of the neutron energy. The similarities between the detected background neutron spectrum and fission sources makes it difficult to discriminate SNM from background based solely on the energies observed. The images produced using maximum likelihood expectation maximization revealed that neutrons preferentially are coming from areas in the environment that have open sky, indicating that the surrounding buildings act as absorbers of neutrons rather than sources as expected by the ship effect. Here, the inherent properties of a neutron scatter camera limit the achievable image quality and the effective deployment to systematically map neutron background signatures due to the low count rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mitigation of High Altitude and Low Earth Orbit Radiation Effects on Microelectronics via Shielding or Error Detection and Correction Systems

The NASA Cooperative Agreement NAG4-210 was granted under the FY2000 Faculty Awards for Research (FAR) Program. The project was proposed to examine the effects of charged particles and neutrons on selected random access memory (RAM) technologies. The concept of the project was to add to the current knowledge of Single Event Effects (SEE) concerning RAM and explore the impact of selected forms of radiation on Error Detection and Correction Systems. The project was established as an extension of a previous FAR awarded to Prairie View A&M University (PVAMU), under the direction of Dr. Richard Wilkins as principal investigator. The NASA sponsored Center for Applied Radiation Research (CARR) at PVAMU developed an electronic test-bed to explore and quantify SEE on RAM from charged particles and neutrons. The test-bed was developed using 486DX microprocessor technology (PC-104) and a custom test board to mount RAM integrated circuits or other electronic devices. The test-bed had two configurations - a bench test version for laboratory experiments and a 400 Hz powered rack version for flight experiments. The objectives of this project were to: 1) Upgrade the Electronic Test-bed (ETB) to a Pentium configuration; 2) Accommodate more than only 8 Mbytes of RAM; 3) Explore Error Detection and Correction Systems for radiation effects; 4) Test modern RAM technologies in radiation environments.

Gupta, Kajal↗

Extension of Cable Electrical Assessment Techniques to Detect and Discriminate Radiation Aging on Cable Insulation Systems (Abstract)

The purpose of this study of the electrical responses of gamma radiation aged low voltage nuclear cables is to advance tools to determine cable condition (extent of damage) and identify degradation location along the cable length. The developed technology will provide nuclear plant operators with the options to focus cable repair, mitigation, or replacement efforts locally and avoid wholesale cable replacement.

42 ENGINEERING↗

System and method for neutron and gamma radiation detection using non-homogeneous material scintillator

The present disclosure relates to a method for detecting incoming radiation having a plurality of differing properties including at least one of differing types, differing energies or differing incoming directions. The method involves using a scintillator structure formed from first and second dissimilar scintillator materials, where the first and second dissimilar scintillator materials emit first and second different colors of light in response to the incoming radiation. A first light detector is used for detecting light having the first color, and a second light detector is used for detecting light having the second color. A first output signal is generated in response to the detection of light having the first color, and a second output signal is generated in response to detecting light having the second color. The first and second output signals are then analyzed to determine at least one property of the incoming radiation.

Brodsky, Jason Philip↗

Dual modality endocavity biopsy imaging system and method

A dual modality endocavity imaging and treatment system for detection of cancer and targeted biopsy and treatment procedures, comprising: a housing; a nuclear detector system housed within the housing and configured for detecting nuclear radiation imaging data; an ultrasound detector system housed within the housing for detecting ultrasound imaging data; a needle associated with the housing and adjustably positionable relative thereto; and a data processing module configured to receive the nuclear radiation imaging data and the ultrasound imaging data and to generate and output an image showing the relative position of the needle and an endocavity object of interest. The needle may include a distinct radiation signature to facilitate imaging thereof.

Lall, Terrence↗

The next-generation magnetic recoil spectrometer (MRSnext) on OMEGA and NIF for diagnosing ion temperature, yield, areal density, and alpha heating

The next-generation magnetic recoil spectrometer (MRSnext) is being designed to replace the current MRS at the National Ignition Facility and OMEGA for measurements of the neutron spectrum from an inertial confinement fusion implosion. The MRSnext will provide a far-superior performance and faster data turnaround than the current MRS systems, i.e., a 2× and 6× improvement in energy resolution at the NIF and OMEGA, respectively, and 20× improvement in data turnaround time. The substantially improved performance of the MRSnext is enabled by using electromagnets that provide a short focal plane (12–16 cm) and unprecedented flexibility for a wide range of applications. In addition to being able to measure neutron yield, apparent ion temperature, areal density, and plasma-flow velocity over a wide range of yields, the NIF MRSnext will be able to directly, uniquely assess the alpha heating of the fuel ions through measurements of the alpha knock-on tail in the neutron spectrum. The goal is to implement a radiation-hard electronic detection system capable of providing rapid data acquisition and analysis. The development of the MRSnext will also set the foundation for the more advanced, time-resolving MRSt and serve as a testbed for its implementation on the NIF.

47 OTHER INSTRUMENTATION↗

Forest Damage Assessment

Thematic Mapper (TM) is an advanced scanning instrument aboard Landsat 4 & 5 originally developed by NASA, now operated as a commercial remote sensing system. The TM detects radiation reflected and emitted from earth objects such as trees in seven bands of the spectrum. Since each object has its own unique spectral "signature" the TM can distinguish among surface features and generate computer processed imagery, specific features of importance to resources managers.

Source record↗

NASA Tech Briefs, February 2011

Topics covered include: Multi-Segment Radius Measurement Using an Absolute Distance Meter Through a Null Assembly; Fiber-Optic Magnetic-Field-Strength Measurement System for Lightning Detection; Photocatalytic Active Radiation Measurements and Use; Computer Generated Hologram System for Wavefront Measurement System Calibration; Non-Contact Thermal Properties Measurement with Low-Power Laser and IR Camera System; SpaceCube 2.0: An Advanced Hybrid Onboard Data Processor; CMOS Imager Has Better Cross-Talk and Full-Well Performance; High-Performance Wireless Telemetry; Telemetry-Based Ranging; JWST Wavefront Control Toolbox; Java Image I/O for VICAR, PDS, and ISIS; X-Band Acquisition Aid Software; Antimicrobial-Coated Granules for Disinfecting Water; Range 7 Scanner Integration with PaR Robot Scanning System; Methods of Antimicrobial Coating of Diverse Materials; High-Operating-Temperature Barrier Infrared Detector with Tailorable Cutoff Wavelength; A Model of Reduced Kinetics for Alkane Oxidation Using Constituents and Species for N-Heptane; Thermally Conductive Tape Based on Carbon Nanotube Arrays; Two Catalysts for Selective Oxidation of Contaminant Gases; Nanoscale Metal Oxide Semiconductors for Gas Sensing; Lightweight, Ultra-High-Temperature, CMC-Lined Carbon/Carbon Structures; Sample Acquisition and Handling System from a Remote Platform; Improved Rare-Earth Emitter Hollow Cathode; High-Temperature Smart Structures for Engine Noise Reduction and Performance Enhancement; Cryogenic Scan Mechanism for Fourier Transform Spectrometer; Piezoelectric Rotary Tube Motor; Thermoelectric Energy Conversion Technology for High-Altitude Airships; Combustor Computations for CO2-Neutral Aviation; Use of Dynamic Distortion to Predict and Alleviate Loss of Control; Cycle Time Reduction in Trapped Mercury Ion Atomic Frequency Standards; and A (201)Hg+ Comagnetometer for (199)Hg+ Trapped Ion Space Atomic Clocks.

Source record↗