At least 73 records · Page 4

SLS Integrated Modal Test Uncertainty Quantification using the Hybrid Parametric Variation Method

Uncertainty in structural loading during launch is a significant concern in the development of spacecraft and launch vehicles. Small variations in launch vehicle and payload mode shapes and their interaction can result in significant variation in system loads. In many cases involving large aerospace systems it is difficult, not economical, or impossible to perform a system modal test. However, it is still vital to obtain test results that can be compared with analytical predictions to validate models. Instead, the “Building Block Approach” is used in which system components are tested individually. Component models are correlated and updated to agree as best they can with test results. The Space Launch System consists of a number of components that are assembled into a launch vehicle. Finite element models of the components are developed, reduced to Hurty/Craig-Bampton models and assembled to represent different phases of flight. The only opportunity to obtain modal test data from an assembled Space Launch System will be during the Integrated Modal Test. There is always uncertainty in every model, which flows into uncertainty in predicted system results. Uncertainty Quantification is used to determine statistical bounds on prediction accuracy based on model uncertainty. For the Space Launch System, model uncertainty is at the Hurty/Craig-Bampton component level. Uncertainty in the Hurty/Craig-Bampton components is quantified using the hybrid parametric variation approach that combines parametric and nonparametric uncertainty. Uncertainty in model form is one of the biggest contributors to uncertainty in complex built-up structures. This type of uncertainty cannot be represented by variations infinite element model input parameters and thus cannot be included in a parametric approach. However, model-form uncertainty can be modeled using a nonparametric approach based on random matrix theory. The hybrid parametric variation method requires the selection of dispersion values for the Hurty/Craig-Bampton fixed-interface eigenvalues, and the Hurty/Craig-Bampton stiffness matrices. Component test/analysis frequency error is used to identify the fixed-interface eigenvalue dispersions, while test/analysis cross-orthogonality is used to identify stiffness dispersion values. The hybrid parametric variation uncertainty quantification approach is applied to the Space Launch System Integrated Modal Test configuration. Monte Carlo analysis is performed, and statistics are determined for modal correlation metrics, frequency response from Integrated Modal Test shakers to selected accelerometers, as well as other metrics for determining how well target modes are excited and identified. If the predicted uncertainty envelopes future Integrated Modal Test results, then there will be increased confidence in the utility of the component-based hybrid parametric variation uncertainty quantification approach.

Uncertainty Quantification↗

Low-cost Quantification of Fluid Flow Parameter Sensitivity using Reduced-order Modeling

Uncertainty quantification of computational fluid dynamics (CFD) simulations is a complicated procedure which still relies in many cases on engineering judgment and factors of safety. This is in part because the computational cost of measuring the simulation's sensitivity to all meaningful parameters (e.g., body surface roughness) and hyperparameters (e.g., subiteration convergence criterion) is intractable for even a single simulation. Reduced-order modeling dramatically lowers this computational cost of simulating fluid flows, but usually only where similar data is already available. In this work, fluid reduced-order models are utilized to quantify a flow's sensitivity to certain physical parameters for the purposes of improved uncertainty quantification. Characteristic observability and sensitivity are both explored. The resulting sensitivity quantifications enable more informed CFD frameworks and more rigorous uncertainty bounds on the resulting data.

uncertainty quantification↗

Low-cost Quantification of Fluid Flow Parameter Sensitivity using Reduced-order Modeling

Uncertainty quantification of computational fluid dynamics (CFD) simulations is a complicated procedure which still relies in many cases on engineering judgment and factors of safety. This is in part because the computational cost of measuring the simulation's sensitivity to all meaningful parameters (e.g., body surface roughness) and hyperparameters (e.g., subiteration convergence criterion) is intractable for even a single simulation. Reduced-order modeling dramatically lowers this computational cost of simulating fluid flows, but usually only where similar data is already available. In this work, fluid reduced-order models are utilized to quantify a flow's sensitivity to certain physical parameters for the purposes of improved uncertainty quantification. Characteristic observability and sensitivity are both explored. The resulting sensitivity quantifications enable more informed CFD frameworks and more rigorous uncertainty bounds on the resulting data.

uncertainty quantification↗

Effective Uncertainty Quantification for Multi-Angle Polarimetric Aerosol Remote Sensing Over Ocean

Multi-angle polarimetric (MAP) measurements can enable detailed characterization of aerosol microphysical and optical properties and improve atmospheric correction in ocean color remote sensing. Advanced retrieval algorithms have been developed to obtain multiple geophysical parameters in the atmosphere–ocean system. Theoretical pixel-wise retrieval uncertainties based on error propagation have been used to quantify retrieval performance and determine the quality of data products. However, standard error propagation techniques in high-dimensional retrievals may not always represent true retrieval errors well due to issues such as local minima and the nonlinear dependence of the forward model on the retrieved parameters near the solution. In this work, we analyze these theoretical uncertainty estimates and validate them using a flexible Monte Carlo approach. The Fast Multi-Angular Polarimetric Ocean coLor (FastMAPOL) retrieval algorithm, based on efficient neural network forward models, is used to conduct the retrievals and uncertainty quantification on both synthetic HARP2 (Hyper-Angular Rainbow Polarimeter 2) and AirHARP (airborne version of HARP2) datasets. In addition, for practical application of the uncertainty evaluation technique in operational data processing, we use the automatic differentiation method to calculate derivatives analytically based on the neural network models. Both the speed and accuracy associated with uncertainty quantification for MAP retrievals are addressed in this study. Pixel-wise retrieval uncertainties are further evaluated for the real AirHARP field campaign data. The uncertainty quantification methods and results can be used to evaluate the quality of data products, as well as guide MAP algorithm development for current and future satellite systems such as NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission.

PACE↗

Positron emission tomography harmonization in the Alzheimer's Disease Neuroimaging Initiative: A scalable and rigorous approach to multisite amyloid and tau quantification

Abstract INTRODUCTION A key goal of the Alzheimer's Disease NeuroImaging Initiative (ADNI) positron emission tomography (PET) Core is to harmonize quantification of β‐amyloid (Aβ) and tau PET image data across multiple scanners and tracers. METHODS We developed an analysis pipeline (Berkeley PET Imaging Pipeline, B‐PIP) for ADNI Aβ and tau PET images and applied it to PET data from other multisite studies. Steps include image pre‐processing, refacing, magnetic resonance imaging (MRI)/PET co‐registration, visual quality control (QC), quantification of tracer uptake, and standardization of Aβ and tau standardized uptake value ratios (SUVrs) across tracers. RESULTS Measurements from 10,105 cross‐sectional and longitudinal Aβ and tau PET scans acquired in several studies between 2010 and 2024 can be processed, harmonized, and directly merged across tracers and cohorts. DISCUSSION The B‐PIP developed in ADNI is a scalable image harmonization approach used in several observational studies and clinical trials that facilitates rigorous Aβ and tau PET quantification and data sharing. Highlights Quantitative results from ADNI Aβ and tau PET data are generated using a rigorous, scalable image processing pipeline This pipeline has been applied to PET data from several other large, multisite studies and trials Quantitative outcomes are harmonizable across studies and are shared with the scientific community

Neurosciences & Neurology↗

Automatic identification and quantification of dense microcracks in high-performance fiber-reinforced cementitious composites through deep learning-based computer vision

Highlights: • A method is presented to detect, locate, quantify, and visualize dense microcracks in HPFRCC. • Quantification of dense microcracks is realized using deep learning method for the first time. • The presented method uses deep learning models that are trained using a realistic dataset size. • The presented method has a high computation efficiency for identifying and quantifying cracks. • The presented method provides crack width with errors up to 50 μm and a R{sup 2} value of 0.984. High-performance fiber-reinforced cementitious composites (HPFRCCs) feature high mechanical strengths, crack resistance, and durability. Under excessive loading, HPFRCCs demonstrate dense microcracks that are difficult to identify using existing methods. This study presents a computer vision method for identification, quantification, and visualization of microcracks in HPFRCCs based on deep learning. The presented method integrates multiple deep learning models and computer vision techniques in a hierarchical architecture. The crack pattern (e.g., number, width, and spacing of cracks) are automatically determined from pictures without human intervention. This study shows that the presented method achieves an accuracy of 0.992 for crack detection and an accuracy finer than 50 μm (R{sup 2} > 0.984) for quantification of crack width when deep learning models are trained using only 200 pictures of HPFRCCs and 200 pictures of conventional concrete with incorporation of data augmentation. The presented method is expected to be also applicable to other materials featuring complex cracks.

36 MATERIALS SCIENCE↗

Rapid failure mode classification and quantification in batteries: A deep learning modeling framework

Unique, rapid identification and quantification of the dominant aging modes in lithium-ion batteries (LiBs) with early and non-specialized test data is a significant scientific challenge. Leveraging synthetic-data, deep-learning (DL) techniques have great potential to enable fast and robust classification and quantification of battery aging modes that produce different patterns of cell aging. This study, for the first time, presents a synthetic–data-based DL modeling framework for rapid and automatic classification and quantification of battery-aging modes and resultant aging with experimental validation. Availing synthetic dQ.dV -1 curves for ~26000 initial conditions and aging modes, the framework classified the dominant aging modes, for cells undergoing fast charge, in fewer than 100 cycles. Upon classification, the framework quantified the evolution of the aging modes, which were often nonuniform with cycling, for 22 gr/NMC532 pouch cells tested up to 600 cycles at different charging rates (1C–9C).

25 ENERGY STORAGE↗

Remote isotope detection and quantification using femtosecond filament-laser ablation molecular isotopic spectrometry

We demonstrate the detection and quantification of isotopes from solid samples remotely at a distance of 36 m. This was accomplished through the combination of femtosecond filaments and laser ablation molecular isotopic spectrometry (F 2 -LAMIS). Isotopically enriched graphite samples with varying 13 C concentration were used and the F 2 -LAMIS emission was measured remotely using a portable spectrometer system. A standardless quantification approach was used to determine the corresponding isotopic ratios. The use of F 2 -LAMIS for the detection and quantification of isotopes at atmospheric pressure without the use of calibration standards opens the possibility to implement this technology for remote sensing of isotopes in field applications

07 ISOTOPE AND RADIATION SOURCES↗

147 Nd Quantification Using HSCCC-Purified Samples

Quantifying the fission product 147 Nd in nuclear debris samples is an important component of post-detonation nuclear forensics. The most accurate quantifications are obtained when Nd is purified from all other fission products, actinides, activation products, and environmental matrix contained within the debris. In this study, a recently developed method for Nd purification was tested, purifying 147 Nd from solutions of mixed fission products using high-speed counter-current chromatography (HSCCC). Importantly, the new method allowed for faster elution of Nd from the column as compared with established high performance liquid chromatography (HPLC) methods, and resulted in accurate/precise 147 Nd quantification by gamma-ray spectrometry. While the up-front equipment costs associated with HSCCC may be higher, its operational costs are on par with those of HPLC (solvents, extractants, power). Gas-flow proportional beta decay counting revealed contamination from the nearest neighbor lanthanide 143 Pr (a gamma-silent radioisotope) in the HSCCC-purified samples, but the activity contribution from 147 Nd could still be quantified. Remarkably consistent elution profiles were observed for the HSCCC method, spanning rare earth element (REE) loadings of more than 10 orders of magnitude (tracer to mmol quantities). In conclusion, the reliability and speed of the new method suggest utility for the rapid separation and quantification of 147 Nd in unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metagenome-Guided Proteomic Quantification of Reductive Dehalogenases in the Dehalococcoides mccartyi -Containing Consortium SDC-9

At groundwater sites contaminated with chlorinated ethenes, fermentable substrates are often added to promote reductive dehalogenation by indigenous or augmented microorganisms. Contemporary bioremediation performance monitoring relies on nucleic acid biomarkers of key organohalide-respiring bacteria, such as Dehalococcoides mccartyi (Dhc). In this work, metagenome sequencing of the commercial, Dhc-containing consortium, SDC-9, identified 12 reductive dehalogenase (RDase) genes, including pceA (two copies), vcrA, and tceA, and allowed for specific detection and quantification of RDase peptides using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Shotgun (i.e., untargeted) proteomics applied to the SDC-9 consortium grown with tetrachloroethene (PCE) and lactate identified 143 RDase peptides, and 36 distinct peptides that covered greater than 99% of the protein-coding sequences of the PceA, TceA, and VcrA RDases. Quantification of RDase peptides using multiple reaction monitoring (MRM) assays with 13 C-/ 15 N-labeled peptides determined 1.8 × 10 3 TceA and 1.2 × 10 2 VcrA RDase molecules per Dhc cell. Ultimately, the MRM mass spectrometry approach allowed for sensitive detection and accurate quantification of relevant Dhc RDases and has potential utility in bioremediation monitoring regimes.

59 BASIC BIOLOGICAL SCIENCES↗

Super-resolving microscopy images of Li-ion electrodes for fine-feature quantification using generative adversarial networks

Abstract For a deeper understanding of the functional behavior of energy materials, it is necessary to investigate their microstructure, e.g., via imaging techniques like scanning electron microscopy (SEM). However, active materials are often heterogeneous, necessitating quantification of features over large volumes to achieve representativity which often requires reduced resolution for large fields of view. Cracks within Li-ion electrode particles are an example of fine features, representative quantification of which requires large volumes of tens of particles. To overcome the trade-off between the imaged volume of the material and the resolution achieved, we deploy generative adversarial networks (GAN), namely SRGANs, to super-resolve SEM images of cracked cathode materials. A quantitative analysis indicates that SRGANs outperform various other networks for crack detection within aged cathode particles. This makes GANs viable for performing super-resolution on microscopy images for mitigating the trade-off between resolution and field of view, thus enabling representative quantification of fine features.

30 DIRECT ENERGY CONVERSION↗

Radiation image reconstruction and uncertainty quantification using a Gaussian process prior

We propose a complete framework for Bayesian image reconstruction and uncertainty quantification based on a Gaussian process prior (GPP) to overcome limitations of maximum likelihood expectation maximization (ML-EM) image reconstruction algorithm. The prior distribution is constructed with a zero-mean Gaussian process (GP) with a choice of a covariance function, and a link function is used to map the Gaussian process to an image. Unlike many other maximum a posteriori approaches, our method offers highly interpretable hyperparamters that are selected automatically with the empirical Bayes method. Furthermore, the GP covariance function can be modified to incorporate a priori structural priors, enabling multi-modality imaging or contextual data fusion. Lastly, we illustrate that our approach lends itself to Bayesian uncertainty quantification techniques, such as the preconditioned Crank–Nicolson method and the Laplace approximation. The proposed framework is general and can be employed in most radiation image reconstruction problems, and we demonstrate it with simulated free-moving single detector radiation source imaging scenarios. We compare the reconstruction results from GPP and ML-EM, and show that the proposed method can significantly improve the image quality over ML-EM, all the while providing greater understanding of the source distribution via the uncertainty quantification capability. Furthermore, significant improvement of the image quality by incorporating a structural prior is illustrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Robust quantification of the diamond nitrogen-vacancy center charge state via photoluminescence spectroscopy

Nitrogen vacancy (NV) centers in diamond are at the heart of many emerging quantum technologies, all of which require control over the NV charge state. Hence, methods for quantification of the relative photoluminescence intensities of the NV 0 and NV − charge states, i.e., a charge state ratio, are vital. Several approaches to quantify NV charge state ratios have been reported but are either limited to bulk-like NV diamond samples or yield qualitative results. We propose an NV charge state quantification protocol based on the determination of sample- and experimental setup-specific NV 0 and NV − reference spectra. The approach employs blue (400–470 nm) and green (480–570 nm) excitation to infer pure NV 0 and NV − spectra, which are then used to quantify NV charge state ratios in subsequent experiments via least squares fitting. We test our dual excitation protocol (DEP) for a bulk diamond NV sample and 20 and 100 nm nanodiamond particles and compare results with those obtained via other commonly used techniques such as zero-phonon line fitting and non-negative matrix factorization. We find that DEP can be employed across different samples and experimental setups and yields consistent and quantitative results for NV charge state ratios that are in agreement with our understanding of NV photophysics. By providing robust NV charge state quantification across sample types and measurement platforms, DEP will support the development of NV-based quantum technologies.

Color center laser spectroscopy↗

Design and execution of a verification, validation, and uncertainty quantification plan for a numerical model of left ventricular flow after LVAD implantation

Left ventricular assist devices (LVADs) are implantable pumps that act as a life support therapy for patients with severe heart failure. Despite improving the survival rate, LVAD therapy can carry major complications. Particularly, the flow distortion introduced by the LVAD in the left ventricle (LV) may induce thrombus formation. While previous works have used numerical models to study the impact of multiple variables in the intra-LV stagnation regions, a comprehensive validation analysis has never been executed. The main goal of this work is to present a model of the LV-LVAD system and to design and follow a verification, validation and uncertainty quantification (VVUQ) plan based on the ASME V&V40 and V&V20 standards to ensure credible predictions. The experiment used to validate the simulation is the SDSU cardiac simulator, a bench mock-up of the cardiovascular system that allows mimicking multiple operation conditions for the heart-LVAD system. The numerical model is based on Alya, the BSC’s in-house platform for numerical modelling. Alya solves the Navier-Stokes equation with an Arbitrary Lagrangian-Eulerian (ALE) formulation in a deformable ventricle and includes pressure-driven valves, a 0D Windkessel model for the arterial output and a LVAD boundary condition modeled through a dynamic pressure-flow performance curve. The designed VVUQ plan involves: (a) a risk analysis and the associated credibility goals; (b) a verification stage to ensure correctness in the numerical solution procedure; (c) a sensitivity analysis to quantify the impact of the inputs on the four quantities of interest (QoIs) (average aortic root flow $Q^{avg}_{Ao}$, maximum aortic root flow $Q^{max}_{Ao}$, average LVAD flow $Q^{avg}_{VAD}$, and maximum LVAD flow $Q^{max}_{VAD}$; (d) an uncertainty quantification using six validation experiments that include extreme operating conditions. Numerical code verification tests ensured correctness of the solution procedure and numerical calculation verification showed a grid convergence index (GCI)95% <3.3%. The total Sobol indices obtained during the sensitivity analysis demonstrated that the ejection fraction, the heart rate, and the pump performance curve coefficients are the most impactful inputs for the analysed QoIs. The Minkowski norm is used as validation metric for the uncertainty quantification. It shows that the midpoint cases have more accurate results when compared to the extreme cases. The total computational cost of the simulations was above 100 [core-years] executed in around three weeks time span in Marenostrum IV supercomputer. This work details a novel numerical model for the LV-LVAD system, that is supported by the design and execution of a VVUQ plan created following recognised international standards. We present a methodology demonstrating that stringent VVUQ according to ASME standards is feasible but computationally expensive.

59 BASIC BIOLOGICAL SCIENCES↗

The Fluid Dynamics Uncertainty Quantification Challenge Problem: XFOIL vs. MFOIL

Uncertainty quantification (UQ) has become more critical in aerospace engineering due to the growing dependence on computational tools for design optimization and performance analyses of aerospace vehicles. Even though the significance of UQ in assessing the credibility of computational analyses is well recognized, its costs and complexity impede its integration into standard practices, particularly in computational fluid dynamics (CFD) and other fluid analyses. This paper presents a UQ study for low-fidelity computational aerodynamics analyses with XFOIL and mfoil (i.e., the MATLAB version of XFOIL with several implementation modifications); these tools are utilized widely in both research and education. The main contributions of this paper are as follows: 1) improved precision in quantifying the uncertainty of the baseline Monte Carlo results used to benchmark surrogate modeling techniques for UQ, 2) quantification of the effect of the implementation differences between XFOIL and mfoil on solution quantities of interest (QoIs), such as lift and pitching moment coefficients, and 3) development of an open-source UQ library for use with XFOIL and mfoil, which has educational values and helps promote UQ for fluid analyses with aerospace applications. Results and discussions revolve around cases 1-4 of the challenge problem posed by the AIAA Fluid Dynamics Technical Committee’s Uncertainty Quantification Discussion Group (UQDG). In case 3, this work employs CFDverify, an open-source solution verification software, to quantify the discretization error and evaluate the extrapolated QoIs based on the grid convergence index (GCI). This UQ study differentiates itself from previous studies in the rigor of handling baseline Monte Carlo uncertainty and in including mfoil, which is a more accessible alternative to XFOIL. Finally, despite the growing computing power, low-fidelity computational tools remain valuable, such as for aerodynamic shape optimization at Mach numbers below 0.65 and low-to-mid Reynolds numbers.

Lay, Aidan S [University of Tennessee, Knoxville (↗

Real-time three-dimensional color doppler evaluation of the flow convergence zone for quantification of mitral regurgitation: Validation experimental animal study and initial clinical experience

BACKGROUND: Pitfalls of the flow convergence (FC) method, including 2-dimensional imaging of the 3-dimensional (3D) geometry of the FC surface, can lead to erroneous quantification of mitral regurgitation (MR). This limitation may be mitigated by the use of real-time 3D color Doppler echocardiography (CE). Our objective was to validate a real-time 3D navigation method for MR quantification. METHODS: In 12 sheep with surgically induced chronic MR, 37 different hemodynamic conditions were studied with real-time 3DCE. Using real-time 3D navigation, the radius of the largest hemispherical FC zone was located and measured. MR volume was quantified according to the FC method after observing the shape of FC in 3D space. Aortic and mitral electromagnetic flow probes and meters were balanced against each other to determine reference MR volume. As an initial clinical application study, 22 patients with chronic MR were also studied with this real-time 3DCE-FC method. Left ventricular (LV) outflow tract automated cardiac flow measurement (Toshiba Corp, Tokyo, Japan) and real-time 3D LV stroke volume were used to quantify the reference MR volume (MR volume = 3DLV stroke volume - automated cardiac flow measurement). RESULTS: In the sheep model, a good correlation and agreement was seen between MR volume by real-time 3DCE and electromagnetic (y = 0.77x + 1.48, r = 0.87, P <.001, delta = -0.91 +/- 2.65 mL). In patients, real-time 3DCE-derived MR volume also showed a good correlation and agreement with the reference method (y = 0.89x - 0.38, r = 0.93, P <.001, delta = -4.8 +/- 7.6 mL). CONCLUSIONS: real-time 3DCE can capture the entire FC image, permitting geometrical recognition of the FC zone geometry and reliable MR quantification.

Validation Studies↗

Quantification of Efficiency of Beneficiation of Lunar Regolith

Electrostatic beneficiation of lunar regolith is being researched at Kennedy Space Center to enhance the ilmenite concentration of the regolith for the production of oxygen in in-situ resource utilization on the lunar surface. Ilmenite enrichment of up to 200% was achieved using lunar simulants. For the most accurate quantification of the regolith particles, standard petrographic methods are typically followed, but in order to optimize the process, many hundreds of samples were generated in this study that made the standard analysis methods time prohibitive. In the current studies, X-ray photoelectron spectroscopy (XPS) and Secondary Electron microscopy/Energy Dispersive Spectroscopy (SEM/EDS) were used that could automatically, and quickly, analyze many separated fractions of lunar simulant. In order to test the accuracy of the quantification, test mixture samples of known quantities of ilmenite (2, 5, 10, and 20 wt%) in silica (pure quartz powder), were analyzed by XPS and EDS. The results showed that quantification for low concentrations of ilmenite in silica could be accurately achieved by both XPS and EDS, knowing the limitations of the techniques. 1

Trigwell, Steve↗

Aeroelastic Uncertainty Quantification Studies Using the S4T Wind Tunnel Model

This paper originates from the joint efforts of an aeroelastic study team in the Applied Vehicle Technology Panel from NATO Science and Technology Organization, with the Task Group number AVT-191, titled "Application of Sensitivity Analysis and Uncertainty Quantification to Military Vehicle Design." We present aeroelastic uncertainty quantification studies using the SemiSpan Supersonic Transport wind tunnel model at the NASA Langley Research Center. The aeroelastic study team decided treat both structural and aerodynamic input parameters as uncertain and represent them as samples drawn from statistical distributions, propagating them through aeroelastic analysis frameworks. Uncertainty quantification processes require many function evaluations to asses the impact of variations in numerous parameters on the vehicle characteristics, rapidly increasing the computational time requirement relative to that required to assess a system deterministically. The increased computational time is particularly prohibitive if high-fidelity analyses are employed. As a remedy, the Istanbul Technical University team employed an Euler solver in an aeroelastic analysis framework, and implemented reduced order modeling with Polynomial Chaos Expansion and Proper Orthogonal Decomposition to perform the uncertainty propagation. The NASA team chose to reduce the prohibitive computational time by employing linear solution processes. The NASA team also focused on determining input sample distributions.

Nikbay, Melike↗