Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quadrupole magnet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Transition energy measurements of the X-ray lines of neon-like europium

Here, we report the measurements of the n = 3 → n = 2 L-shell X-ray transitions of neon-like Eu 53+ . These include all seven allowed electric dipole (E1) transitions, five electric quadrupole (E2) transitions, and one magnetic quadrupole (M2) transition. The measurements were carried out at the EBIT-I electron beam ion trap facility at Livermore using an X-ray calorimeter. The measured values agree with many-body perturbation theory calculations within the experimental uncertainties. This includes the transitions that involve a 2s electron and that are, therefore, strongly affected by quantum electrodynamical effects.

74 ATOMIC AND MOLECULAR PHYSICS↗

Systematic Errors Induced by Dipole Component Change in Quadrupole Beam-Based Alignment Measurements for Circular Accelerators

Beam-based alignment (BBA) for quadrupole magnets is now a well-established process for circular accelerators to steer beam orbit through the magnetic centers such that beam orbit is not disturbed when the gradients of quadrupoles are changed. At some facilities, the centers estimated from BBA techniques are also used as a proxy for steering beam through the centers of nearby nonlinear magnets to minimize degradation of nonlinear dynamics caused by off-centered orbit. The random errors associated with BBA are well known, but very little attention has been paid to the systematic error generated by a dipole component change, or equivalently a shift in the magnetic center, when the quadrupole strength is varied. The analytical formulas for this error and its amplification factor (potentially a few orders of magnitude) with respect to the magnetic center motion have been derived and confirmed with simulations. We address the significance of this error as well as the part that cannot be estimated from the beam-based measurement alone. Finally, the BBA measurements obtained at NSLS-II and their systematic errors on the order of hundreds of microns are discussed.

43 PARTICLE ACCELERATORS↗

Magnetic Measurements and Alignment Results of LQXFA/B Cold Mass Assemblies at Fermilab

MQXFA production series quadrupole magnets are being built for the Hi-Lumi (HL) LHC upgrade by the U.S. Accelerator Upgrade Project (US-HL-LHC AUP). These magnets are being placed in pairs, as a cold mass, within cryostats at Fermilab, and are being tested to assess alignment and magnetic performance at Fermilab's horizontal test stand facility. The ~10 m - long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis position, and for magnet variations in positioning and local field profile. Here this paper describes the results of the magnetic and alignment measurements which characterize the first LQXFA/B assembly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reconstruction of the 4D beam matrix

The widely used transverse parameters characterizing particle beams are the Twiss parameters. These parameters can be measured experimentally but they do not fully characterize the beam since they do not account for possible correlations in particle distribution between two transverse coordinates. These correlations may occur due to uncompensated magnetic field at the cathode or misalignment of focusing quadrupoles in the transport beamline. We test a novel diagnostic for diagnosing full 4D beam matrix which may be used to identify such imperfections. The diagnostic is based on transporting the beam through the beamline which includes a quadrupole and a skew quadrupole magnets and measuring the resulting 2D beam distribution at the screen downstream. Such a measurement can be viewed as measuring a 2D projection of the 4D distribution. Different settings of the quads provide measurements of different slices of the phase space. The reconstruction of the original beam matrix from a number of measurements is done using machine learning algorithm, which provides a fast and reliable way of reconstruction for an arbitrary configuration of the scanning beamline. In August 2024, we set up the diagnostic beamline to perform a quadrupole scan of the beam. The setup includes a skew quadrupole, a regular quadrupole, and a screen. The images on the screen were post-processed to remove experimental artifacts and enhance contrast by eliminating background noise outside the core of the distribution=. The rms parameters of the distribution were then calculated and used as inputs for the reconstruction algorithm. This algorithm attempts to determine the initial beam matrix that produces expected images on the screen closely matching the observed images across all quadrupole settings. The algorithm found a solution in which the expected rms parameters closely align with the observations. Validation of the results is planned for FY25.

43 PARTICLE ACCELERATORS↗

Vector potential and surface magnetic field in magnetoelectric antiferromagnetic materials

A general formula for the average vector potential of bulk periodic systems is proposed and shown to set the boundary conditions at magnetic interfaces. Here, for antiferromagnetic materials, the study reveals a unique relation between the macroscopic potential and the orientation-dependent magnetic quadrupole as a result of the different crystalline and magnetic symmetries. In particular, at surfaces and interfaces of a truncated bulk without inversion and time-reversal symmetries, the average vector potential exhibits a discontinuity which results in an interfacial magnetic field. In general, however, due to the surface and interface electronic and atomic relaxations, additional magnetization may result. For the experimentally observed magnetoelectric antiferromagnets, in particular, our symmetry analysis suggests that the relaxation effects could well be a system response to the presence of such a potential discontinuity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

3D Mechanical Analysis of a Compact Nb 3 Sn IR Quadrupole for EIC

Abstract-The Electron Ion Collider (EIC) will require large aperture quadrupole magnets for the Hadron beam in the insertion region. Key requirements include high field, compact size, and tight control of the fringe fields. A 120 mm aperture, 308.4 mm outer diameter actively shielded Nb 3 Sn quadrupole model is under development to support these goals. This work is being carried out by a collaboration of BNL, JLAB and LBNL. A compact shell-based structure preloaded with a bladder and key system was developed for this project. In this paper, the effect of the compact structure on the mechanical behavior was investigated. In particular, the impact of the assembly tolerances and coil size variations on the actual coil stresses and bladder pressures was computed and compared with results from larger bladder and key structures developed for the LHC IR. The longitudinal preload is provided by stainless steel rods. Differently from other bladder and key magnets, the rods are first preloaded axially before coil axial load is applied. This new design aims to increase the overall stiffness of the system and reduce the longitudinal coil displacement during powering. Based on the results of a 3D mechanical analysis, the preliminary preload targets for the EIC quadrupole assembly will be reviewed and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic Measurements of HL-LHC AUP Cryo-Assemblies at Fermilab

LQXFA/B production series cryogenic assemblies are being built for the LHC upgrade by the HL-LHC Accelerator Upgrade Project (AUP). These contain a pair of MQXFA quadrupole magnets combined as a cold mass within a vacuum vessel, and are to be installed in the IR regions of the LHC. The LQXFA/B are being tested at 1.9 K to assess alignment and magnetic performance at Fermilab's horizontal test facility. The ~10 m - long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis location, and for variations in axis position and local field profile. A multi-probe, PCB-based rotating coil and Single Stretched Wire system are employed for these measurements. To accurately determine rotating coil location and angles within the cold mass, a laser tracker is utilized to record multiple targets at one end of the probe. This paper describes the measurements, probes/equipment, and techniques used to perform the necessary characterization of the cold mass.

43 PARTICLE ACCELERATORS↗

Magnetic Measurements of $\mathrm{HL-LHC AUP}$ Cryo-Assemblies at Fermilab

LQXFA/B production series cryogenic assemblies are being built for the LHC upgrade by the HL-LHC Accelerator Upgrade Project (AUP). These contain a pair of MQXFA quadrupole magnets combined as a cold mass within a vacuum vessel, and are to be installed in the IR regions of the LHC. The LQXFA/B are being tested at 1.9 K to assess alignment and magnetic performance at Fermilab's horizontal test facility. The ~10 m long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis location, and for variations in axis position and local field profiles. A multi-probe, PCB-based rotating coil and a Single Stretched Wire system are employed for these measurements. To accurately determine rotating coil location and angles within the cold mass, a laser tracker is utilized to record multiple targets at one end of the probe. Here this paper describes the measurements, probes/equipment, and techniques used to perform the necessary characterization of the cold mass.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Challenges and Solutions of Meeting the Assembly Specifications for the 4.5 m Long MQXFA Magnets for the Hi-Luminosity LHC

The U.S. High-Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP) has, in the recent years, developed assembly specifications for the 4.5 m long MQXFA magnets, which are 150 mm aperture high-field Nb 3 Sn low-β quadrupole magnets that are being built for the CERN Hi-Luminosity LHC (HL-LHC) upgrade. While the specifications were based on lessons learned from the LHC Accelerator Research Program (LARP) effort and the MQXFS and MQXFA prototype magnets, the experience gained from having both MQXFA07 and MQXFA08 magnets not meeting performance specifications during cold testing actually catalyzed a better understanding of the impact of the target assembly specifications and a subsequent refinement of the same. This paper summarizes a body of assembly data from the Pre-Series (MQXFA03-MQXFA07) and Series magnets (MQXFA08-MQXFA11) that have been built to date, and discusses the processes employed to successfully face the challenge of ensuring that the assembly specifications are met for the duration of the project.

43 PARTICLE ACCELERATORS↗

Long Reach Robotic Arm

The Accelerator Division at Fermilab began a robotics program, known as the AD Robotics Initiative. A multi-axis robotic arm was proposed to be included in the program. This summer internship, our team began the planning and design for this project, called the Long Reach Robotic Arm. The problem is that critical systems around the magnets require analysis when water leaks cause them to fail. However, the tightly compacted parts and the quadrupole magnet, weighing approximately 1,000 pounds, cause access viewing problems. The process of having to dismantle and remove the magnet is time-consuming; it is not an efficient solution. The goal for the Long Reach Robotic Arm was to extend and reach behind the component of the Main Injector while "snaking" around and avoiding obstructions. At the start of the project, my teammate, Amanda Hoeksema, and I coded a program in the C language that will determine the number of links and their respective lengths for the robot arm. After, we began the 3D CAD model of the robot arm, base, and counterweight system. The design of the Long Reach Robotic Arm provided a learning experience in learning how to code in the C programming language, using SDL libraries and understanding mechanical engineering.

43 PARTICLE ACCELERATORS↗

ORBIT CORRECTION STUDIES ON THE ELECTRON TRANSPORT LINE FROM RCS TO ESR

A dedicated electron transfer line from Rapid Cycling Synchrotron (RCS) to Electron Storage Ring (ESR), referred to as the RTE line has been designed for the Electron-Ion Collider (EIC). The beamline follows a straight-line geometry, with a length of 133 m, and is consists with two matching sections and a FODO section for beam diagnostics. Imperfections with magnet alignments introduce orbit distortions, making orbit correction scheme a critical component in the design. To facilitate orbit correction, each quadrupole magnet is equipped with a pair of beam position monitors (BPMs) and kickers. The Singular Value Decomposition (SVD) algorithm is used for orbit correction and tolerance studies. This paper presents the ongoing progress in the optics design and error correction scheme of the RTE line.

Neththikumara, I. [Thomas Jefferson National Accel↗

Analysis of the Mechanical Performance of the 4.2-m-Long MQXFA Magnets for the Hi-Lumi LHC Upgrade

Under the U.S. High Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP), the 150 mm bore, high-field Nb 3 Sn low-{eta}_MQXFA quadrupole magnets are being fabricated, assembled and tested, in the context of the CERN Hi-Luminosity LHC (HL-LHC) upgrade. These magnets have 4.2 m magnetic length and 4.56 m long iron yoke. To date, eight MQXFA magnets have been tested. One of the magnets additionally underwent a successful endurance test with 40 triggered quenches, and two magnets did not perform as expected. This work summarizes for the first time the available strain gauge data from eight identical Nb 3 Sn MQXFA tested magnets, focusing on the endurance test, and on a possible cause of underperformance of the two magnets that did not pass the vertical test. Here we applied methods to prevent this from happening in future MQXFA magnets, which shown to be effective for last two tested magnets.

43 PARTICLE ACCELERATORS↗

Evaluation of the Room Temperature Field Quality Measurements of HL-LHC MQXFA Magnet Assemblies

As a member of the multi-lab U.S. High Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP), Lawrence Berkeley National Laboratory (LBNL) is assembling high-field Nb3Sn low-beta MQXFA quadrupole magnets for eventual installation at CERN as part of the HL-LHC upgrade. Each magnet undergoes room temperature magnetic measurements at two points during the assembly process: once after completion of the coil pack sub-assembly and once after the magnet is fully assembled and pre-loaded. Beyond its use to verify that each magnet assembly can meet operational requirements, the data from this two-stage measurement process allow for investigation into the impact of the pre-loading operation on field quality. Recent measurements on magnet rebuilds as well as exploratory coil pack reconfigurations also provide an opportunity to see in isolation the effects of changes to a magnet’s coil selection or coil layout. In this work, we present the magnetic measurement results of MQXFA magnets assembled or currently in process, focusing particularly on magnets with data corresponding to multiple builds, and discuss trends and insights which may be beneficial for the remaining MQXFA magnet production or for future Nb3Sn accelerator magnets.

Doyle, Jennifer [LBNL, Berkeley] (ORCID:0009000079↗

Feasibility Study of NSLS-II Sextupole BBA Measurement

In storage ring light sources, beam-based alignment (BBA) which adjusts the BPM centers to the quadrupole magnet centers is a common practice to maintain the machine performance. For more reliable and convenient BBA process, in the design of the storage ring, BPMs are located as close as possible to the quadrupoles. The most common method is scanning the position of the beam at the BPM (equivalently at the adjacent quadrupole) and find the position where the quadrupole strength change does not give change in the closed orbit. In the simulation of the feasibility test, we choose parameters, tune, orbit and phase advance and measure their variations depending on the sextupole offsets. Also, together with the real configuration of family, we simulate the individual power supply case for the comparisons. In this note, the simulation processes and the results are presented.

43 PARTICLE ACCELERATORS↗

Design and Construction of a Prototype B1pF Large Aperture Rutherford Cable Superconducting Magnet for the EIC Interaction Region

Brookhaven National Laboratory (BNL) was chosen to host the international Electron-Ion Collider (EIC), which will collide high energy and highly polarized hadron and electron beams with a center of mass energy up to 140 GeV. The Interaction Region (IR) requires several large aperture, relatively high field superconducting dipole and quadrupole magnets, some of which are very closely spaced. B1pF is a large aperture (300 mm coil ID), medium field (4.2 T), 3 meter long superconducting dipole magnet. Its size is larger than the largest superconducting magnet in the RHIC accelerator (180 mm DX dipole, 4.2 T, 3.7 m long). As such, B1pF was chosen as the representative magnet to be prototyped to demonstrate the technological choice, design and construction details. Here, this paper describes the analyses and considerations which informed both the magnet and magnet tooling designs. This paper will summarize the construction results so far, in particular the plan for novel coil winding tooling and the test coil winding & curing program that was carried out prior to coil and magnet construction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and Construction of a Superconducting “Direct Wind” R&D Magnet for the EIC Interaction Region

Brookhaven National Laboratory (BNL) was chosen to host the international Electron-Ion Collider (EIC), which will collide high energy and highly polarized hadron and electron beams with a center of mass energy up to 140 GeV. The Interaction Region (IR) [1] requires several large aperture, relatively high field superconducting dipole and quadrupole magnets, some of which are very closely spaced.\r\nA value engineering effort is underway as part of the EIC Project to construct and test a Direct Wind magnet [2] (coil comprised of NbTi conductor deposited directly onto a support tube, in this instance tapered, and secured mechanically against Lorentz forces afterwards) to replace two Rutherford cable collared magnets. This magnet exceeds the combination of aperture, number of coil \r\nlayers, and magnetic field, as compared to existing accelerator and R&D Direct Wind magnets to date. Furthermore, construction has been completed using a newly commissioned winding machine, upgraded in anticipation of the upcoming EIC production coil fabrication. Design, analysis, construction issues, lessons learned and accomplishments to date shall be discussed, including the \r\nachieved corrections to multipoles made to successive coil layers based on warm magnetic measurements of preceding layers.

43 PARTICLE ACCELERATORS↗

Development of Advanced Nb 3 Sn Superconductors for Future Energy-Frontier Colliders

Development of Advanced Nb 3 Sn Superconductors for Future Energy-Frontier Colliders: • Present record of particle collision energy: 13 TeV, by the LHC. • Further push of the energy frontier requires higher magnetic field in circular accelerators: E (in TeV) = 0.3R (in km)•B (in T). • The proposed Future Circular Collider (FCC) plans to increase B from 8 T (in LHC) to 16 T. • Nb3Sn wires will be the workhorse conductor for building dipole and quadrupole magnets for FCC.

43 PARTICLE ACCELERATORS↗

Comparison of Multi-Scale Nonlinear and Conventional Linear Methods for Stress Analysis of Nb 3 Sn Superconducting Magnets

Here this is an extension of the work on a multi-scale nonlinear procedure that demonstrated how to conduct nonlinear stress analysis of Nb 3 Sn superconducting accelerator magnets. The nonlinear procedure uses measured stress-strain curves of annealed copper, Nb 3 Sn strands and coil samples as inputs, which reduces the number of assumptions made for material properties—key uncertainties of any engineering analysis. The results from nonlinear analysis, semi-nonlinear analysis, and linear analysis of the same QFFB2 Nb 3 Sn quadrupole magnet under the same temperature and loads, were compared and discussed. The comparison illustrates that nonlinear stress analysis is significantly more accurate than other methods. As the superconducting coil block is a complex, composite material, it would be inadequate to assume the whole coil block to be linear, either isotropic or orthotropic. It is imperative to conduct nonlinear analysis by simulating the superconducting coil to the level of detail of the individual cables and individual strands. The nonlinear stress analysis procedure can be used to simulate not only Nb 3 Sn magnets, but also NbTi and HTS magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗