Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pyranometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Measuring Broadband IR Irradiance in the Direct Solar Beam (Poster)

Solar and atmospheric science radiometers, e.g. pyranometers, pyrheliometers, and photovoltaic cells are calibrated with traceability to a consensus reference, which is maintained by Absolute Cavity Radiometers (ACRs). The ACR is an open cavity with no window, developed to measure extended broadband direct solar irradiance beyond the ultraviolet and infrared bands below and above 0.2 micrometers and 50 micrometers, respectively. On the other hand, pyranometers and pyrheliometers are developed to measure broadband shortwave irradiance from approximately 0.3 micrometers to 3 micrcometers, while the present photovoltaic cells are limited to approximately 0.3 micrometers to 1 micrometers. The broadband mismatch of ACR versus such radiometers causes discrepancy in radiometers' calibration methods that has not been discussed or addressed in the solar and atmospheric science literature. Pyrgeometers are also used for solar and atmospheric science applications and calibrated with traceability to consensus reference, yet calibrated during nighttime only, because no consensus reference has yet been established for the daytime longwave irradiance. This poster shows a method to measure the broadband IR irradiance in the direct solar beam from 3 micrometers to 50 micrometers, as first step that might be used to help develop calibration methods to address the mismatch between broadband ACR and shortwave radiometers, and the lack of a daytime reference for pyrgeometers. The irradiance was measured from sunrise to sunset for 5 days when the sun disk was cloudless; the irradiance varied from approximately 1 Wm-2 to 16 Wm-2 for solar zenith angle from 80 degres to 16 degrees respectively; estimated uncertainty is 1.5 Wm-2.

47 OTHER INSTRUMENTATION↗

Relative Accuracy of 1-Minute and Daily Total Solar Radiation Data for 12 Global and 4 Direct Beam Solar Radiometers: Preprint

This report evaluates the relative performance of 12 global and four direct beam solar radiometers deployed at a single site over a 12-month period. Test radiometer irradiances were compared with a reference irradiance consisting of either an absolute cavity radiometer (during calibrations) or a low uncertainty thermopile pyrheliometer (during the evaluation period) for pyrheliometers; and for pyranometers a reference global irradiance computed from the reference pyrheliometer and diffuse irradiance from a shaded pyranometer.

14 SOLAR ENERGY↗

The “Fresnel Equations” for Diffuse radiation on Inclined photovoltaic Surfaces (FEDIS)

Here the well-known Fresnel equations solve for the reflection and transmission of light for precise incident angles. The transmission of diffuse radiation incident on a planar or domed surface is often needed for real-world applications. Due to the complexity of the Fresnel equations, the analytical solution of the integration has hitherto been unobtainable over the last centuries. Therefore, this problem was numerically solved by integrating the angular transmittances in space often leading to substantial computing burden and bias in the results. To efficiently estimate the solar energy resource for a glass-covered photovoltaic (PV) module, we derive an analytical solution of diffuse transmission based on the rigorous integration of an alternate form of the Fresnel equations. The approach leads to a simple yet accurate relative transmittance model that reconciles the solar energy sensed by pyranometers and PV panels. With limited and clearly stated approximations, the complex mathematical derivation resulted in an elegant solution. An experiment using 1-year of data at the National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) shows that the new model dramatically decreases the disparity between the solar radiation measurements by a Kipp and Zonen CM Pyranometer 22 (CMP22) and an IMT reference cell on a 1-axis tracking system. The solution in this paper can be widely used in scientific and engineering research, development, and applications wherever the Fresnel equations are used.

14 SOLAR ENERGY↗

Improved broadband solar irradiance from the multi-filter rotating shadowband radiometer

Approximations to total and diffuse horizontal and direct normal, broadband solar irradiance (280-4000 nm) can be obtained from the multi-filter rotating shadowband radiometer (MFRSR) using the unfiltered silicon channel of this seven-channel instrument. However, the unfiltered silicon channel only responds to wavelengths between 300 and 1100 nm and does not have a uniform spectral response. In contrast, the best, more expensive, first-class, thermopile-based radiometers respond fairly uniformly to all solar wavelengths. While the total horizontal and direct normal solar irradiance measurements made with the MFRSR unfiltered silicon channel are reasonable if carefully calibrated with a thermopile radiometer, the diffuse horizontal irradiance calibrated in this way has a large bias. These issues are common to all inexpensive, silicon-cell, solar pyranometers. In this paper we use a multivariate, linear regression technique for approximating the thermopile-measured total, diffuse, and direct broadband solar irradiances using the six, narrowband filters and the open-channel of an MFRSR. The calibration of the MFRSR for broadband solar by comparing various combinations of MFRSR channels to first-class thermopile instruments is illustrated, and methods to track the instrument response during field deployments are investigated. We also suggest an approach to calibrate the open-channel for all three components that could improve measurements that are made using typical, commercial, silicon-cell pyranometers. (author)

47 OTHER INSTRUMENTATION↗

Shortwave Radiometer Calibration Methods Comparison and Resulting Solar Irradiance Measurement Differences: A User Perspective

Banks financing solar energy projects require assurance that these systems will produce the energy predicted. Furthermore, utility planners and grid system operators need to understand the impact of the variable solar resource on solar energy conversion system performance. Accurate solar radiation data sets reduce the expense associated with mitigating performance risk and assist in understanding the impacts of solar resource variability. The accuracy of solar radiation measured by radiometers depends on the instrument performance specification, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of different calibration methods provided by radiometric calibration service providers, such as NREL and manufacturers of radiometers, on the resulting calibration responsivity. Some of these radiometers are calibrated indoors and some outdoors. To establish or understand the differences in calibration methodology, we processed and analyzed field-measured data from these radiometers. This study investigates calibration responsivities provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The BORCAL method provides the outdoor calibration responsivity of pyranometers and pyrheliometers at 45 degree solar zenith angle, and as a function of solar zenith angle determined by clear-sky comparisons with reference irradiance. The BORCAL method also employs a thermal offset correction to the calibration responsivity of single-black thermopile detectors used in pyranometers. Indoor calibrations of radiometers by their manufacturers are performed using a stable artificial light source in a side-by-side comparison between the test radiometer under calibration and a reference radiometer of the same type. In both methods, the reference radiometer calibrations are traceable to the World Radiometric Reference (WRR). These different methods of calibration demonstrated +1% to +2% differences in solar irradiance measurement. Analyzing these differences will ultimately help determine the uncertainty of the field radiometer data and guide the development of a consensus standard for calibration. Further advancing procedures for precisely calibrating radiometers to world reference standards that reduce measurement uncertainty will allow more accurate prediction of solar output and improve the bankability of solar projects.

14 SOLAR ENERGY↗

Evaluation of Radiometers Deployed at the National Renewable Energy Laboratory's Solar Radiation Research Laboratory

This study analyzes the performance of various commercially available radiometers used for measuring global horizontal irradiances and direct normal irradiances. These include pyranometers, pyrheliometers, rotating shadowband radiometers, and a pyranometer with fixed internal shading and are all deployed at the National Renewable Energy Laboratory's Solar Radiation Research Laboratory. Data from 32 global horizontal irradiance and 19 direct normal irradiance radiometers are presented. The radiometers in this study were deployed for one year (from April 1, 2011, through March 31, 2012) and compared to measurements from radiometers with the lowest values of estimated measurement uncertainties for producing reference global horizontal irradiances and direct normal irradiances.

14 SOLAR ENERGY↗

Measuring Broadband IR Irradiance in the Direct Solar Beam (Presentation)

Solar and atmospheric science radiometers, e.g. pyranometers, pyrheliometers, and photovoltaic cells are calibrated with traceability to a consensus reference, which is maintained by Absolute Cavity Radiometers (ACRs). The ACR is an open cavity with no window, developed to measure extended broadband direct solar irradiance beyond the ultraviolet and infrared bands below and above 0.2 um and 50um, respectively. On the other hand, pyranometers and pyrheliometers are developed to measure broadband shortwave irradiance from approximately 0.3 um to 3 um, while the present photovoltaic cells are limited to approximately 0.3 um to 1 um. The broadband mismatch of ACR versus such radiometers causes discrepancy in radiometers' calibration methods that has not been discussed or addressed in thesolar and atmospheric science literature. Pyrgeometers are also used for solar and atmospheric science applications and are calibrated with traceability to consensus reference, yet are calibrated during nighttime only, because no consensus reference has yet been established for the daytime longwave irradiance. This poster shows a method to measure the broadband IR irradiance in the direct solarbeam from 3 um to 50 um, as a first step that might be used to help develop calibration methods to address the mismatch between broadband ACR and shortwave radiometers, and the lack of a daytime reference for pyrgeometers. The irradiance was measured from sunrise to sunset for 5 days when the sun disk was cloudless; the irradiance varied from approximately 1 Wm-2 to 16 Wm-2 for solar zenithangle from 80 degrees to 16 degrees respectively; estimated uncertainty is 1.5 Wm-2.

14 SOLAR ENERGY↗

Measuring Broadband IR Irradiance in the Direct Solar Beam and Recent Developments

Solar and atmospheric science radiometers such as pyranometers, pyrheliometers, and photovoltaic cells are calibrated with traceability to a consensus reference which is maintained by Absolute Cavity Radiometers (ACRs). An ACR is an open cavity with no window, developed to measure the extended broadband spectrum of the terrestrial direct solar beam irradiance that extends beyond the ultraviolet and infrared bands; i.e. below 0.2 um and above 50 um, respectively. On the other hand, the pyranometers and pyrheliometers were developed to measure broadband shortwave irradiance from approximately 0.3 um to 3 um, while the present photovoltaic cells are limited to the spectral range of approximately 0.3 um to 1 um. The broadband mismatch of ACR versus such radiometers causes discrepancy in radiometers' calibration methods that has not been discussed or addressed in the solar and atmospheric science literature. Pyrgeometers, which measure the atmospheric longwave irradiance, are also used for solar and atmospheric science applications and calibrated with traceability to a consensus reference, yet they are calibrated during nighttime only, because no consensus reference has been established for the daytime longwave irradiance. This poster describes a method to measure the broadband longwave irradiance in the terrestrial direct solar beam from 3 um to 50 um, as a first step that might be used to help develop calibration methods to address the mismatch between broadband ACR and shortwave radiometers, and the lack of a daytime reference for pyrgeometers. The described method is used to measure the irradiance from sunrise to sunset; the irradiance varied from approximately 1 Wm-2 to 16 Wm-2 with an estimated uncertainty of 1.5 Wm-2, for a solar zenith angle range from 80 degrees to 16 degrees, respectively. Recent development shows that there is greater than 1.1 percent bias in measuring shortwave solar irradiance.

14 SOLAR ENERGY↗

The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements

This study addresses the effect of calibration methodologies on calibration responsivities and the resulting impact on radiometric measurements. The calibration responsivities used in this study are provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The BORCAL method provides outdoor calibration responsivity of pyranometers and pyrheliometers at a 45 degree solar zenith angle and responsivity as a function of solar zenith angle determined by clear-sky comparisons to reference irradiance. The BORCAL method also employs a thermal offset correction to the calibration responsivity of single-black thermopile detectors used in pyranometers. Indoor calibrations of radiometers by their manufacturers are performed using a stable artificial light source in a side-by-side comparison of the test radiometer under calibration to a reference radiometer of the same type. These different methods of calibration demonstrated 1percent to 2 percent differences in solar irradiance measurement. Analyzing these values will ultimately enable a reduction in radiometric measurement uncertainties and assist in developing consensus on a standard for calibration.

14 SOLAR ENERGY↗

Improved Field Evaluation of Reference Cell Using Spectral Measurements: Preprint

Spectral irradiance measurements as opposed to modeled spectral values are used to evaluate the effects of changing spectral distributions on the output of reference solar cells. Comparisons are made on a one-axis tracking surface to a Class A pyranometer. The ratio of the reference cells to reference pyranometers exhibit a bias over the day. Spectral and temperature modeling reproduce most but not all changes in the ratio over the day. Sources for this difference in modeling and performance of the reference cells are examined.

14 SOLAR ENERGY↗

The De-Icing Comparison Experiment – ARM Contribution (DICEXACO) Field Campaign Report

Longwave and shortwave radiative fluxes are fundamental quantities regularly observed globally using broadband radiometers. In regions conducive to frost, rime, and snow, ice frequently builds up on sensor windows, contaminating measurements. Since icing occurs under particular meteorological conditions, associated data loss constitutes a climatological bias. Furthermore, the signal caused by ice is difficult to distinguish from that of clouds, hampering efforts to identify contaminated data in post-processing. Because of the sensitivity of radiometers to internal temperature instabilities, there are limitations to using heat as a de-icing method, and consequently substantial amounts of data are lost. The De-Icing Comparison Experiment (D-ICE) was a campaign carried out at $Utqia\dot{g}vik$ (formerly known as Barrow) and Oliktok Point, Alaska, from August 2017 to July 2018. The purpose of D-ICE was to evaluate ventilation and heating technologies developed to mitigate radiometer icing. D-ICE consisted of 20 pyranometers and 5 pyrgeometers operating in various ventilator housings alongside operational stations run by the NOAA Global Monitoring Division (GMD) at NOAA’s Barrow Atmospheric Baseline Observatory. D-ICE also evaluated the sky radiometer (SKYRAD) systems at the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) North Slope of Alaska (NSA) and Oliktok Point (OLI; third ARM Mobile Facility [AMF3]) observatories. In total, 34 systems were evaluated (8 of which were SKYRAD radiometers). All radiometers were monitored continuously using cameras, and a total of more than one million images of sensor domes were archived collectively between the stations. Data collected as part of D-ICE by NOAA can be found through the project web page, https://www.esrl.noaa.gov/psd/arctic/d-ice/. The DICEXACO component of D-ICE (https://www.arm.gov/research/campaigns/nsa2017dicexaco) are the images collected at 10-min intervals at both OLI and NSA and are the subject of this report. Two cameras were installed at each ARM station, one directed towards the SKYRAD tracker and the other towards the SKYRAD global precision spectral pyranometer (PSP).

Oliktok Point, North Slope of Alaska, SKYRAD, pyra↗

Spectral Effects in Albedo and Rearside Irradiance Measurment for Bifacial Performance Estimation: Preprint

Albedo data are essential for accurate prediction of bifacial PV module performance. However, spectral response mismatch between PV modules and irradiance sensors used in albedometers can limit the accuracy of performance predictions. In order to provide quantitative assessment of this effect, we investigate via simulation the differences in spectrally responsive albedo measured with thermopile pyranometers and crystallinesilicon PV reference cells in comparison to a representative crystalline-silicon bifacial PV module for nine different representative ground surface materials. Calculations are performed using simulated solar spectra together with catalogued spectral reflectivity data distributed with the SMARTS simulation software. For the specific materials considered, the results show that albedo measurement using thermopile pyranometers could over or under-estimate the ground-reflected radiation usable by a bifacial PV module by up to 10%, versus only approximately 4% total range of variation for a PV reference cell.

Albedo↗

Masking of photovoltaic system performance problems by inverter clipping and other design and operational practices

We describe how performance problems can be “masked,” or not readily evident by several causes: by photovoltaic (PV) system configuration (such as the size of the PV array capacity relative to the size of the inverter and the resultant clipped operating mode); by instrumentation design, installation, and maintenance (such as a misaligned or dirty pyranometer); by contract clauses (when operational availability is transformed to contractual availability, which excludes many factors); and by identified management and operational practices (such as reporting on a portfolio of plants rather than individually). A simple method based on a duration curve is introduced to overcome shortcomings of Performance Ratio based on nameplate capacity and Performance Index based on hourly simulation when quantifying masking effects, and inverter clipping and pyranometer soiling are presented as two examples of the new method. With a better understanding of the non-transparency of masking issues, stakeholders can better interpret performance data and deliver improved AC and DC plant conditions through PV system operation and maintenance (O&M) for improved performance, reduced O&M costs, and a more consistently delivered, and reduced, levelized cost of energy (LCOE).

14 SOLAR ENERGY↗

Measuring solar reflectance - Part I: Defining a metric that accurately predicts solar heat gain

Solar reflectance can vary with the spectral and angular distributions of incident sunlight, which in turn depend on surface orientation, solar position and atmospheric conditions. A widely used solar reflectance metric based on the ASTM Standard E891 beam-normal solar spectral irradiance underestimates the solar heat gain of a spectrally selective ''cool colored'' surface because this irradiance contains a greater fraction of near-infrared light than typically found in ordinary (unconcentrated) global sunlight. At mainland US latitudes, this metric R{sub E891BN} can underestimate the annual peak solar heat gain of a typical roof or pavement (slope {<=} 5:12 [23 ]) by as much as 89 W m{sup -2}, and underestimate its peak surface temperature by up to 5 K. Using R{sub E891BN} to characterize roofs in a building energy simulation can exaggerate the economic value N of annual cool roof net energy savings by as much as 23%. We define clear sky air mass one global horizontal (''AM1GH'') solar reflectance R{sub g,0}, a simple and easily measured property that more accurately predicts solar heat gain. R{sub g,0} predicts the annual peak solar heat gain of a roof or pavement to within 2 W m{sup -2}, and overestimates N by no more than 3%. R{sub g,0} is well suited to rating the solar reflectances of roofs, pavements and walls. We show in Part II that R{sub g,0} can be easily and accurately measured with a pyranometer, a solar spectrophotometer or version 6 of the Solar Spectrum Reflectometer. (author)

14 SOLAR ENERGY↗

Measured Long-Term Solar Irradiance for Climate Studies

Solar radiation is primarily measured using high-quality radiometers (e.g., pyranometers and pyrheliometers). These instruments need to be calibrated regularly (every two years at a minimum). They are also susceptible to various sources of uncertainties. Therefore, rigorous data quality assessment is required to obtain high-confidence data from these radiometers. This is especially true when the data is used to understand climatic trends and/or extreme weather events. In this study, we attempted to create a continuous and reliable dataset by correcting the underlying data which we believe contains bias due to reference pyranometers swap procedures. These biases can be significant which can be up to two percentage points thereby influencing the interpretation of climate changes and/or extreme events. This study elaborates on the biases and methods to correct those biases.

data integrity↗

Solar variability datalogger

To address the lack of knowledge of local solar variability, we have developed and deployed a low-cost solar variability datalogger (SVD). While most currently used solar irradiance sensors are expensive pyranometers with high accuracy (relevant for annual energy estimates), low-cost sensors display similar precision (relevant for solar variability) as high-cost pyranometers, even if they are not as accurate. In this work, we present evaluation of various low-cost irradiance sensor types, describe the SVD, and present validation and comparison of the SVD collected data. In conclusion, the low cost and ease of use of the SVD will enable a greater understanding of local solar variability, which will reduce developer and utility uncertainty about the impact of solar photovoltaic (PV) installations and thus will encourage greater penetrations of solar energy.

14 SOLAR ENERGY↗

Solar Resource Measurements in Cocoa, Florida (FSEC) - Equipment Loaned to NREL: Cooperative Research and Development Final Report, CRADA Number CRD-08-318

Site-specific measurements of global and diffuse solar irradiance components, passively separated by alternate shading and unshading of a pyranometer mounted under a shading band with alternating opaque and open panels (for a site other than NREL) are needed to verify the underlying theory and mathematical techniques for developing direct, global and diffuse renewable resource data from such a system. These data are used for several research and development activities consistent with the NREL mission: Establish a national 30-year climatological database of measured solar irradiances; Support development of radiative transfer models for estimating solar irradiance from available meteorological observations; Provide solar resource information needed for technology deployment and operations. NREL will provide the supporting equipment (Shadow Bank Stand) for the specially designed shading band. FSEC will provide the calibrated pyranometer and perform data acquisition of the radiometer signal. Data acquired under this agreement will be shared with the NREL Principle Investigator for the purposes of validating techniques for estimating direct radiation from global and diffuse components measured with the ZEBRA system.

14 SOLAR ENERGY↗