Engineering PapersSearch

SEARCH · Engineering Papers

Results for “pv cost”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Solar Photovoltaics Resilient Fasteners Levelized Cost of Energy (LCOE) Tool

Solar photovoltaics (PV) module fasteners are one of the most common structural failure points on PV systems, particularly in high winds and coastal areas with ocean spray. Some fastener types have been shown to survive these conditions at higher rates than others. The fastener type, material, quantity, and placement all impact performance. Fasteners that fail less often typically have a higher upfront cost, but this investment can pay off in savings from less frequent torque audits (which reduces O&M costs), reduced system damage, and decreased system downtime. We developed an Excel-based tool to evaluate different module fasteners for a PV system - either a new or retrofit project - and compare differences in upfront and outyear costs to determine the expected life cycle costs and simple payback periods of different fastener options. The tool is site-specific, with inputs including system attributes (such as system size, location, price of power) and fastener attributes (such as design, washer type, nut type, use of locking hardware, materials, installation time, and torque audit requirements). A baseline fastener scenario can be compared to up to four proposed fastener scenarios. In addition to presenting expected life cycle cost implications of the different fastener options, the tool produces results showing the reductions in outyear costs needed to offset any initial cost premiums for more reliable fasteners across four categories: preventative O&M, avoided damage, reduced downtime, and reduced insurance premiums. These numbers can serve as decision aids for users when considering fastener options on new or existing projects. This poster will present the tool, methodology, and scenarios using example sites to highlight the tool capabilities and how it can inform different fastener decisions on different projects. Future work includes incorporating lifetime expected damage costs by embedding damage function curves that the authors are developing from field data.

14 SOLAR ENERGY

Feasibility of Passive MOSFET Paralleling for Photovoltaic Current-Voltage Curves

Current-voltage curves are an important method of characterizing Photovoltaic (PV) Modules. NREL has developed several low-cost MOSFET-based devices that can characterize PV cells and modules. The size of PV modules that can be measured is limited by the power limitations of a single MOSFET. By using multiple MOSFET devices, each can operate at a lower current, paralleled on resistance is also decreased allowing for higher power loads. Operating multiple devices in parallel can cause an imbalance in current, thus causing some devices to conduct more, pushing them into a thermal runaway condition. To investigate this, an active feedback circuit was tested with paralleled devices using a PV module load. The efficacy, limitations, and design considerations of using parallel MOSFET loads for PV characterization are explored. This work is not new, but the implementation of a paralleled architecture in a low cost characterization tool is novel.

14 SOLAR ENERGY

Demonstration of an All-Refractory Corrosion-Resistant Molten Salt Pumping and Storage Infrastructure Up to 950 degrees C

Concentrating solar power (CSP) with thermal energy storage (TES) has an estimated cost similar to solar photovoltaics (PV) with lithium-ion batteries (LIB), but CSP + TES has the potential for significantly reduced cost by operating above 700 degrees C. However, this requires a TES medium and containment infrastructure which are chemically compatible and do not degrade above 700 degrees C. MgCl2-KCl-NaCl (MKN) salt is a promising medium, but when MKN salt has small amounts of water and oxygen dissolved in it, it excessively corrodes conventional commercial alloys. Here, we consider refractory materials including graphite, carbon-carbon composite (C/C), and molybdenum because they maintain high mechanical strength at elevated temperatures and are expected to resist corrosion by MKN salt. While selection of refractory materials is often constrained by the need to remain chemically stable in air, this work uses an enclosure filled with inert gas to allow the use of materials like graphite and molybdenum. Notably, graphite components can seal against liquids unlike many brittle refractory materials. We demonstrate a centrifugal pump and mechanical seals made of refractory materials in a laboratory-scale circulation loop, which successfully operated continuously for more than 49 h at temperatures ranging from 750 degrees C to 950 degrees C with no mechanical failures or chemical degradation of the refractory materials. To the best of our knowledge, this is the highest temperature molten salt circulation loop that has been successfully developed, and this refractory infrastructure allows for operation at even much higher temperatures (<1600 degrees C) if a storage medium with a lower vapor pressure is used. The principles of this architecture are relevant to other applications with high temperature flowing metals and salts including Generation IV nuclear fission reactors for power production and molten salt electrolysis reactors for metallurgical processing.

14 SOLAR ENERGY

FACT, Mega-ROSA, SOLAROSA

The Flexible Array Concentrator Technology (FACT) is a lightweight, high-performance reflective concentrator blanket assembly that can be used on flexible solar array blankets. The FACT concentrator replaces every other row of solar cells on a solar array blanket, significantly reducing the cost of the array. The modular design is highly scalable for the array system designer, and exhibits compact stowage, good off-pointing acceptance, and mass/cost savings. The assembly s relatively low concentration ratio, accompanied by a large radiative area, provides for a low cell operating temperature, and eliminates many of the thermal problems inherent in high-concentration-ratio designs. Unlike other reflector technologies, the FACT concentrator modules function on both z-fold and rolled flexible solar array blankets, as well as rigid array systems. Mega-ROSA (Mega Roll-Out Solar Array) is a new, highly modularized and extremely scalable version of ROSA that provides immense power level range capability from 100 kW to several MW in size. Mega-ROSA will enable extremely high-power spacecraft and SEP-powered missions, including space-tug and largescale planetary science and lunar/asteroid exploration missions. Mega-ROSA's inherent broad power scalability is achieved while retaining ROSA s solar array performance metrics and missionenabling features for lightweight, compact stowage volume and affordability. This innovation will enable future ultra-high-power missions through lowcost (25 to 50% cost savings, depending on PV and blanket technology), lightweight, high specific power (greater than 200 to 400 Watts per kilogram BOL (beginning-of-life) at the wing level depending on PV and blanket technology), compact stowage volume (greater than 50 kilowatts per cubic meter for very large arrays), high reliability, platform simplicity (low failure modes), high deployed strength/stiffness when scaled to huge sizes, and high-voltage operation capability. Mega-ROSA is adaptable to all photovoltaic and concentrator flexible blanket technologies, and can readily accommodate standard multijunction and emerging ultra-lightweight IMM (inverted metamorphic) photovoltaic flexible blanket assemblies, as well as ENTECHs Stretched Lens Array (SLA) and DSSs (Deployable Space Systems) FACT, which allows for cost reduction at the array level.

Spence, Brian

Global techno-economic and life cycle greenhouse gas emissions assessment of solar and wind based renewable hydrogen production

This study conducts a global assessment of renewable hydrogen production pathways, focusing on techno-economic performance and life cycle greenhouse gas (GHG) emissions. It evaluates standalone solar photovoltaic (PV), wind, and hybrid PV/wind systems, integrated with proton exchange membrane (PEM) electrolyzers, through multi-objective optimization and considering embodied emissions in manufacturing PV, wind and electrolyzers. Results identify optimal configurations to minimize levelized cost of hydrogen (LCOH) and carbon intensity (CI) of hydrogen, showing potential reductions of cost and CI by 2030. Standalone PV systems can achieve LCOH values smaller than 6.5 USD/kg H 2 and CI less than 2.5 kg CO 2 eq/kg H 2 in regions with high solar irradiance, such as North Africa, the Middle East and Chile. Wind systems in regions such as Middle East, North Africa, Australia and Central United States achieve LCOH below 5 USD/kg H 2 and CI under 1.5 kg CO 2 eq/kg H 2 . Hybrid systems emerge as the optimal solution for minimizing both the LCOH and CI by maximizing the use of renewable energy. Moreover, the results also indicate that, with the technological advancements, future reduction in the capital cost of renewable energy systems and the PEM electrolyzer as well as the trade of coproduct O 2 could drive the LCOH of all the RES-based hydrogen systems below 1 USD/kg H 2 and the CI below zero in different regions as Middle East, North Africa and Central United State

08 HYDROGEN

Cost-optimized energy storage operation for a grid-connected solar PV system at community and individual scales

This study provides a comparative analysis of grid-connected PV-integrated battery storage at individual and community scales. The paper addresses the challenge of managing energy demand-generation mismatch by using a battery energy storage optimization algorithm, which minimizes operational costs while accounting for battery degradation. Also, this work introduces a broader evaluation basis that includes seasonal variability, grid exchange smoothness, and scalability across different battery capacities. Results show that community-scale storage more effectively dampens grid exchange power fluctuations and reduces system costs, particularly with moderate price differences between electricity buying and selling prices and low battery capacities. The paper also analyzes the impacts of static control versus cost-optimized battery system management. Here, it is shown that the gap in system costs between the cost-optimized and static control scenarios widens as the price difference increases.

25 ENERGY STORAGE

Technoeconomic Analysis (TEA)

Techno-economic analysis (TEA) for the DuraMAT Consortium includes the following areas: linking solar photovoltaic (PV) technology trends to reliability implications; providing a framework to calculate technology costs, yielding insights useful for research decision-making, proposals, technology selection, and publications; and examining technology tradeoffs considering lifecycle project economics. This poster highlights results from the first and second iterations of the DuraMAT Technology Scouting reports as well as the updated Simplified PV Levelized Cost of Energy (LCOE) Calculator.

14 SOLAR ENERGY

Benefits of the SolarAPP+ Online Permitting Software

The Solar Automated Permit Processing Plus (SolarAPP+) software is an online platform that provides plan review and instantly issues permits for code-compliant residential photovoltaic (PV) systems.

automated permitting

5 Easy Steps to SolarAPP+ Adoption

The Solar Automated Permit Processing Plus (SolarAPP+) software is an online platform that provides plan review and instantly issues permits for code-compliant residential photovoltaic (PV) systems. Here's how your jurisdiction can get started.

automated permitting

Estimating the impact of tariff-driven behind-the-meter storage operation on distribution grid investments

Increasing growth of distributed solar photovoltaics (PV) and electric vehicles (EV) can strain local distribution networks and require costly upgrades. Distributed battery storage, often deployed alongside PV, can be used to mitigate those costs, depending on how batteries are operated. This study evaluates the potential deferral value of distributed battery storage across a range of tariff structures, focusing on the rate structures most commonly available to residential customers today and related variants. Deferrals are evaluated with a least-cost distribution grid expansion optimization model to identify requirements on line reconductoring, transformer upgrades, and voltage regulator installations under each tariff. Results show that TOU rates and net billing tariffs can yield meaningful deferral value, depending on specific tariff structure features. Under the best performing tariff structure tested, storage produced a median annualized deferral value of $7.18 per kW of storage capacity ( kW S ) across all feeders in the sample, though deferral values were considerably larger for feeders with peak loads that coincide with utility system peak, i.e., timing of TOU peak period. In contrast, under an unrestricted TOU design with no restrictions on grid charging or discharging, the median deferral value was $0/ kW S illustrating the critical importance of tariff structure details.

Rodriguez-Garcia, Luis

Solar Electric System

Heat Pipe Technology, Inc. undertook the development of a PV system that could bring solar electricity to the individual home at reasonable cost. His system employs high efficiency PV modules plus a set of polished reflectors that concentrate the solar energy and enhance the output of the modules. Dinh incorporated a sun tracking system derived from space tracking technology. It automatically follows the sun throughout the day and turns the modules so that they get maximum exposure to the solar radiation, further enhancing the system efficiency.

Source record

Low embodied energy and carbon, high lifetime silicon boules via a combined chemical vapor deposition/float zone process

This work evaluates a new process route to making float zone (Fz)-quality silicon wafers using a combination of computational fluid dynamics (CFD) modeling and technoeconomic analysis. Our analysis finds that the new process competes with Czochralski (Cz)-grown wafers on a levelized cost of energy system level. The new process also decreases embodied energy and carbon of silicon photovoltaics (PV) by ~6x circumventing the energy-costly Siemens process used in polycrystalline silicon (poly-Si) production plants to generate feedstock for Fz and Cz boules. Instead of using poly-Si from the Siemens process to feed crystallization, the new process uses the high-purity, trichlorosilane (TCS) precursor gas to grow a poly-Si feed rod in-situ during a modified Fz1,2 boule growth process. The gas-to-boule float zone process enables opportunity to produce high-purity (low metals and oxygen content), uniformly doped single crystal silicon boules and wafers with high bulk lifetimes (τ bulk > 15 ms) to enable higher efficiency cells (>27 %) with fewer known degradation mechanisms than Czochralski (Cz)-grown wafers. These benefits reduce the levelized cost of electricity (LCOE) of PV-produced electricity. Here we show the results of our CFD and chemical modeling of the process to prove feasibility and economic viability.

14 SOLAR ENERGY

Economic viability of photovoltaic power for development assistance applications

This paper briefly discusses the development assistance market and examines a number of specific photovoltaic (PV) development assistance field tests, including water pumping/grain grinding (Tangaye, Upper Volta), vaccine refrigerators slated for deployment in 24 countries, rural medical centers to be installed in Ecuador, Guyana, Kenya and Zimbabwe, and remote earth stations to be deployed in the near future. A comparison of levelized energy cost for diesel generators and PV systems covering a range of annual energy consumptions is also included. The analysis does not consider potential societal, environmental or political benefits associated with PV power. PV systems are shown to be competitive with diesel generators, based on life cycle cost considerations, assuming a system price of $20/W(peak), for applications having an annual energy demand of up to 6000 kilowatt-hours per year.

Bifano, W. J.

Evaluating Utility Costs Savings and Resilience: A Case Study in Port Arthur, Texas

This study evaluates the techno-economic feasibility of integrating solar photovoltaics (PV), battery energy storage systems (BESS), and generators to enhance both cost savings and resilience in critical community facilities in Port Arthur, Texas. Using NREL's REopt model, we analyze four facilities: the Golden Triangle Empowerment Center (GTEC), Lamar State College (LSC), Port Arthur Independent School District (PAISD), and Port Arthur Transit (PAT). A key aspect of the analysis is the incorporation of the Value of Lost Load (VoLL) and microgrid upgrade costs to assess the hidden value of resilience during grid outages. While standalone PV scenarios show moderate cost reductions and a 10-15% decrease in CO2 emissions, the inclusion of resilience measures with BESS and generators significantly increases system costs. However, the hidden value of resilience - quantified through avoided outage costs - leads to a substantial improvement in financial outcomes, resulting in positive Net Present Value (NPV) at many sites. The study demonstrates that resilient solar and storage systems offer both economic and resilience benefits, particularly for underserved communities, by balancing energy savings and enhanced operational continuity during outages.

14 SOLAR ENERGY

Cross-sectoral synergies for household energy savings: the role of electric vehicles, solar photovoltaics, and remote work

Over the past two decades, new technologies and behavioral shifts – such as electric vehicles, solar photovoltaics, and increased work-from-home practices – have reshaped residential electricity consumption and cost. However, their combined or synergistic impact on a household’s electricity cost remains unexplored. Leveraging data from the 2020 Residential Energy Consumption Survey, this study uses a structural equation model to unravel the extent to which the bundled adoption of EV-PV and stay-at-home decisions impact the total electricity cost of households. Results indicate that adopting both EVs and PV reduces electricity costs by 31% despite a 16% rise in consumption. When combined with stay-at-home practices, households still experience a 13% cost reduction, even with a 25% increase in electricity consumption. In conclusion, these findings suggest that financial savings are not merely a byproduct of adopting new technologies or behavioral changes but could serve as a key consideration for household contemplating engagement with multiple modern energy solutions simultaneously.

14 SOLAR ENERGY

Flat-plate solar array project of the US Department of Energy's National Photovoltaics Program: Ten years of progress

The Flat-Plate Solar Array (FSA) Project, a Government-sponsored photovoltaics project, was initiated in January 1975 (previously named the Low-Cost Silicon Solar Array Project) to stimulate the development of PV systems for widespread use. Its goal then was to develop PV modules with 10% efficiency, a 20-year lifetime, and a selling price of $0.50 per peak watt of generating capacity (1975 dollars). It was recognized that cost reduction of PV solar-cell and module manufacturing was the key achievement needed if PV power systems were to be economically competitive for large-scale terrestrial use.

Christensen, Elmer

Demonstration of GaAs-Based Photovoltaics on Acoustically Spalled Surfaces Grown by MOCVD

This study demonstrates the potential of sonic lift-off (SLO) technology for repeatable substrate reuse in gallium arsenide (GaAs)–based photovoltaics (PVs), offering a pathway toward cost effective production for terrestrial PV applications. Single-junction GaAs solar cells fabricated on acoustically spalled substrates achieved performance metrics comparable with those grown on standard commercial substrates, exhibiting short-circuit current densities (J sc ) of approximately 26.2–26.4 mA/cm 2 , open-circuit voltages (V oc ) around 1001 mV, fill factors (FFs) of 84%, and AM1.5G efficiencies near 22%. These results confirm that one reuse cycle can be realized without a performance penalty, offering a direct pathway to reducing substrate cost in fabrication. Furthermore, subsequent reuse of the substrates highlighted critical challenges, as devices fabricated from reused substrates showed significant degradation in performance (J sc of 15.5 mA/cm 2 , V oc of 748 mV, FF of 72%, and efficiency of 8%), primarily due to degradation of the epitaxial structure resulting from repeated spalling cycles.

Acoustic Spalling

Photovoltaic Reliability Workshop (PVRW) 2025 Proceedings: Presentations

NREL hosts this annual workshop so that solar technology experts can discuss current and future issues in PV reliability. Longer-lasting PV systems make lower-cost solar electricity and have less impact on the environment, human health, and natural resources. PVRW offers a combination of oral presentations, panel discussions with vigorous audience participation, and poster presentations. At our workshop, every attendee is a presenter or the sole guest of a presenter.

14 SOLAR ENERGY