Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Enhancements to the Engine Data Interpretation System (EDIS)

The Engine Data Interpretation System (EDIS) expert system project assists the data review personnel at NASA/MSFC in performing post-test data analysis and engine diagnosis of the Space Shuttle Main Engine (SSME). EDIS uses knowledge of the engine, its components, and simple thermodynamic principles instead of, and in addition to, heuristic rules gathered from the engine experts. EDIS reasons in cooperation with human experts, following roughly the pattern of logic exhibited by human experts. EDIS concentrates on steady-state static faults, such as small leaks, and component degradations, such as pump efficiencies. The objective of this contract was to complete the set of engine component models, integrate heuristic rules into EDIS, integrate the Power Balance Model into EDIS, and investigate modification of the qualitative reasoning mechanisms to allow 'fuzzy' value classification. The result of this contract is an operational version of EDIS. EDIS will become a module of the Post-Test Diagnostic System (PTDS) and will, in this context, provide system-level diagnostic capabilities which integrate component-specific findings provided by other modules.

Hofmann, Martin O.↗

Quasi-CW Laser Diode Bar Life Tests

NASA's Goddard Space Flight Center is developing technology for satellite-based, high peak power, LIDAR transmitters requiring 3-5 years of reliable operation. Semi-conductor laser diodes provide high efficiency pumping of solid state lasers with the promise of long-lived, reliable operation. 100-watt quasi- CW laser diode bars have been baselined for the next generation laser altimeters. Multi-billion shot lifetimes are required. The authors have monitored the performance of several diodes for billions of shots and investigated operational modes for improving diode lifetime.

Stephen, Mark A.↗

Development and Validation of High Performance Unshrouded Centrifugal Impeller

The feasibility of using a two-stage unshrouded impeller turbopump to replace the current three-stage reusable launch vehicle engine shrouded impeller hydrogen pump has been evaluated from the standpoint of turbopump weight reduction and overall payload improvement. These advantages are a by-product of the higher tip speeds that an unshrouded impeller can sustain. The issues associated with the effect of unshrouded impeller tip clearance on pump efficiency and head have been evaluated with one-dimensional tools and full three-dimensional rotordynamic fluid reaction forces and coefficients have been established through time dependent computational fluid dynamics (CFD) simulation of the whole 360 degree impeller with different rotor eccentricities and whirling ratios. Unlike the shrouded impeller, the unshrouded impeller forces are evaluated as the sum of the pressure forces on the blade and the pressure forces on the hub using the CFD results. The turbopump axial thrust control has been optimized by adjusting the first stage impeller backend wear ring seal diameter and diverting the second stage backend balance piston flow to the proper location. The structural integrity associated with the high tip speed has been checked by analyzing a 3D-Finite Element Model at maximum design conditions (6% higher than the design speed). This impeller was fabricated and tested in the NASA Marshall Space Flight Center water-test rig. The experimental data will be compared with the analytical predictions and presented in another paper. The experimental data provides validation data for the numerical design and analysis methodology. The validated numerical methodology can be used to help design different unshrouded impeller configurations.

Chen, Wei-Chung↗

Sensitivities of Tropical Cyclones to Surface Friction and the Coriolis Parameter in a 2-D Cloud-Resolving Model

The sensitivities to surface friction and the Coriolis parameter in tropical cyclogenesis are studied using an axisymmetric version of the Goddard cloud ensemble model. Our experiments demonstrate that tropical cyclogenesis can still occur without surface friction. However, the resulting tropical cyclone has very unrealistic structure. Surface friction plays an important role of giving the tropical cyclones their observed smaller size and diminished intensity. Sensitivity of the cyclogenesis process to surface friction. in terms of kinetic energy growth, has different signs in different phases of the tropical cyclone. Contrary to the notion of Ekman pumping efficiency, which implies a preference for the highest Coriolis parameter in the growth rate if all other parameters are unchanged, our experiments show no such preference.

Chao, Winston C.↗

6S Return Samples: Assessment of Air Quality in the International Space Station (ISS) Based on Solid Sorbent Air Sampler (SSAS) and Formaldehyde Monitoring Kit (FMK) Analyses

The toxicological assessments of SSAS and FMK analytical results are reported. Analytical methods have not changed from earlier reports. Surrogate standard recoveries from the SSAS tubes were 66-76% for 13C-acetone, 85-96% for fluorobenzene, and 73-89% for chlorobenzene. Post-flight flows were far below pre-flight flows and an investigation of the problem revealed that the reduced flow was caused by a leak at the interface of the pump inlet tube and the pump head. This resulted in degradation of pump efficiency. Further investigation showed that the problem occurred before the SSAS was operated on orbit and that use of the post-flight flows yielded consistent and useful results. Recoveries from formaldehyde control badges were 86 to 104%. The two general criteria used to assess air quality are the total-non-methane-volatile organic hydrocarbons (NMVOCs) and the total T-value (minus the CO2 and formaldehyde contributions). The T values will not be reported for these data due to the flow anomaly. Control of atmospheric alcohols is important to the water recovery system engineers, hence total alcohols (including acetone) are also shown for each sample. Octafluoropropane (OFP) is not efficiently trapped by the sorbents used in the SSAS. Because formaldehyde is quantified from sorbent badges, its concentration is also listed separately. These five indices of air quality are summarized.

James, John T.↗

Evaluating Long-Term Changes in Atmospheric Ozone

Ozonesondes have made inexpensive, accurate measurements of ozone from the ground to 30km for more than 50 years. The data are used extensively for trend analyses and for evaluation of satellite and model data products, and are also part of climatologies that are used as a priori data for satellite retrievals. They are essential as a transfer standard when merging shorter satellite-derived time series, and are the most important source of trend-quality long-term records below about 18 km. The importance of long-term ozonesonde records as a stable reference has led to increased attention to quantifying uncertainties and changes in ozonesonde data. Based on past intercomparison data, ECC sondes show a modest (~1-5%) high bias with respect to UV-absorption measurements (including MOZAIC-IAGOS) in the troposphere, with an uncertainty of 5%, but no evidence of a change with time. Other sonde types show an increase of 5-20% in sensitivity to tropospheric ozone from 1970-1995. Agreement in the stratosphere is much better. In the past 20 years ozonesonde precision has improved by a factor of 2, primarily through the adoption of strict standard operating procedures. In addition, many of the most important ozonesonde records have been re-evaluated and corrected, and detailed estimates made of their biases and uncertainties. Corrections to historical data for known issues may reduce biases but simultaneously introduce additional uncertainties. The uncertainty budget for the ozone partial pressure reading has contributions from stoichiometry, cell background current, pump efficiency and temperature, sensing solution type and volume. The much-discussed “background current” has recently been shown to be primarily related to reaction stoichiometry. Several quality assurance issues remain, but are tractable problems that can be addressed with further research. This will be required if the present goal of better than 5% overall uncertainty throughout the global ozonesonde network is to be achieved. Finally, the importance of regular sonde intercomparisons, employing UV photometers traceable to the modern UV-absorption standard, and of regular comparison of operational station records with multiple satellite sensors, is emphasized.

Ozonesondes↗

Efficiency and threshold pump intensity of CW solar-pumped solid-state lasers

The authors consider the relation between the threshold pumping intensity, the material properties, the resonator parameters, and the ultimate slope efficiencies of various solid-state laser materials for solar pumping. They clarify the relation between the threshold pump intensity and the material parameters and the relation between the ultimate slope efficiency and the laser resonator parameters such that a design criterion for the solar-pumped solid-state laser can be established. Among the laser materials evaluated, alexandrite has the highest slope efficiency of about 12.6 percent; however, it does not seem to be practical for a solar-pumped laser application because of its high threshold pump intensity. Cr:Nd:GSGG is the most promising for solar-pumped lasing. Its threshold pump intensity is about 100 air-mass-zero (AM0) solar constants and its slope efficiency is about 12 percent when thermal deformation is completely prevented.

Hwang, In H.↗

High Efficiency End-Pumped Ho:Tm:YLF Disk Amplifier

Space based coherent lidar for global wind measurement requires an all solid state laser system with high energy, high efficiency and narrow linewidth that operates in the eye safe region. A Q-switched, diode pumped Ho:Tm:YLF 2 micrometer laser with output energy of as much as 125 mJ at 6 Hz with an optical-to-optical efficiency of 3% has been reported. Single frequency operation of the laser was achieved by injection seeding. The design of this laser is being incorporated into NASA's SPARCLE (SPAce Readiness Coherent Lidar Experiment) wind lidar mission. Laser output energy ranging from 500 mJ to 2 J is required for an operational space coherent lidar. We previously developed a high energy Ho:Tm:YLF master oscillator and side pumped power amplifier system and demonstrated a 600-mJ single frequency pulse at a repetition rate of 10 Hz. Although the output energy is high, the optical-to-optical efficiency is only about 2%. Designing a high energy, highly efficient, conductively cooled 2-micrometer laser remains a challenge. In this paper, the preliminary result of an end-pumped amplifier that has a potential to provide a factor 3 of improvement in the system efficiency is reported.

Yu, Jirong↗

Efficient flashlamp-pumped IBr laser

The operating characteristics and scaling parameters of a flashlamp-pumped, 4-m-long IBr laser were investigated to further evaluate its potential as a solar-pumped laser. A peak power of 3 kW/sq cm at 2.7 microns was achieved at 4-Torr IBr pressure. A gain of 0.07 per m was measured at a maximum capacitor discharge energy of 4 kJ. The threshold input power necessary for lasing was found to decrease by a factor of 4 and the laser pulse width increased fourfold as the active gain length was increased from 1 to 4 m. A maximum pulse width of 120 microseconds was achieved with 10-Torr argon diluent added to 4-Torr IBr. Quenching of the excited state by the parent molecule was shown to be unimportant for pressures less than 4-Torr IBr. An intrinsic efficiency in the range of 12 percent has been measured for flashlamp-pumped IBr.

Zapata, L. E.↗

Practical and efficient magnetic heat pump

Method for pumping heat magnetically at room temperature is more economical than existing refrigeration systems. Method uses natural magneto-thermal effect of gadolinium metal to establish temperature gradient across length of tube. Regenerative cyclic process in which gadolinium sample is magnetized and gives off heat at one end of tube, and then is demagnetized at other end to absorb heat has established temperature gradients of 144 degrees F in experiments near room temperature. Other materials with large magnetothermal effects can be used below room temperature. Possible commercial applications include freeze-drying and food processing, cold storage, and heating and cooling of buildings, plants, and ships.

Brown, G. V.↗

Efficient CW diode-pumped Tm, Ho:YLF laser with tunability near 2.067 microns

A conversion efficiency of 42 percent and slope efficiency of approximately 60 percent relative to absorbed pump power are reported from a continuous wave diode-pumped Tm, Ho:YLF laser at 2 microns with output power of 84 mW at sub-ambient temperatures. The emission spectrum is etalon tunable over a range of 16/cm centered on 2.067 microns, with fine tuning capability of the transition frequency with crystal temperature at a measured rate of about -0.03/cm-K. The effective emission cross section is measured to be 5 x 10 exp -21 sq cm. These and other aspects of the laser performance are discussed in the context of calculated atmospheric absorption characteristics in this spectral region and potential use in remote sensing applications.

Mcguckin, B. T.↗

Blackbody absorption efficiencies for six lamp pumped Nd laser materials

Utilizing high resolution spectra, the absorption efficiencies for six Nd laser materials were calculated as functions of the effective blackbody temperature of the lamp and laser crystal size. The six materials were Nd:YAG, Nd:YLF, Nd:Q-98 Glass, Nd:YVO4, Nd:BEL, and Nd:Cr:GSGG. Under the guidelines of this study, Nd:Cr:GSGG's absorption efficiency is twice the absorption efficiency of any of the other laser materials.

Cross, Patricia L.↗

Method and apparatus for efficient operation of optically pumped laser

An optically pumped single mode laser, e.g., Nd:YAG crystal (20) with planoconcave mirrors is increased in efficiency by an order of magnitude to about 8% by optics (25, 27) for focusing the high power multimode output of laser diode arrays (21, 22) into the mode volume (20') of the laser medium (20). A plurality of these optically pumped single mode lasers (1-4) may be cascaded in a ring with dichroic mirrors (M.sub.1 -M.sub.4) at the corners for coupling in the laser diode arrays, each having its own means for spatially tailoring its beam to concentrate pump distribution inside the lasing mode volume of the medium. An InGaAlAs pump diode (30) with its wavelength the same as the lasing medium makes the ring unidirectional.

Sipes, Jr., Donald L.↗

Cavity blackbody-pumpd lasers: Present research status

The basic concept for a blackbody cavity is given. A comparison between the direct solar-pumped laser efficiency and one which is indirectly pumped by a blackbody cavity shows that they are similar to a carnot cycle. The blackbody spectrum used to optically pump the lasant material is shown. Also shown is the physical principle behind the blackbody laser idea. An example of an infrared laser media is given. A system study was conducted to scale cavity blackbody pumped lasers to high output powers.

Christiansen, W.↗

Efficiency of Nd laser materials with laser diode pumping

For pulsed laser-diode-pumped lasers, where efficiency is the most important issue, the choice of the Nd laser material makes a significant difference. The absorption efficiency, storage efficiency, and extraction efficiency for Nd:YAG, Nd:YLF, Nd:GSGG, Nd:BEL, Nd:YVO4, and Nd:glass are calculated. The materials are then compared under the assumption of equal quantum efficiency and damage threshold. Nd:YLF is found to be the best candidate for the application discussed here.

Barnes, Norman P.↗

LOX/LH2 vane pump for auxiliary propulsion systems

Positive displacement pumps offer potential efficiency advantages over centrifugal pumps for future low thrust space missions. Low flow rate applications, such as space station auxiliary propulsion or dedicated low thrust orbiter transfer vehicles, are typical of missions where low flow and high head rise challenge centrifugal pumps. The positive displacement vane pump for pumping of LOX and LH2 is investigated. This effort has included: (1) a testing program in which pump performance was investigated for differing pump clearances and for differing pump materials while pumping LN2, LOX, and LH2; and (2) an analysis effort, in which a comprehensive pump performance analysis computer code was developed and exercised. An overview of the theoretical framework of the performance analysis computer code is presented, along with a summary of analysis results. Experimental results are presented for pump operating in liquid nitrogen. Included are data on the effects on pump performance of pump clearance, speed, and pressure rise. Pump suction performance is also presented.

Hemminger, J. A.↗