Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “process cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

PINCH POINT ANALYSIS OF GAS COOLERS IN TRANSCRITICAL R1336mzz(Z) HIGH-TEMPERATURE HEAT PUMPS

The majority of high-temperature heat pumps (HTHPs) operate subcritical vapor compression cycles, where the maximum sink temperature is limited by the critical temperature of refrigerants. In HTHPs with a sink temperature of ≥ 150°C, transcritical cycles overcome this limitation by rejecting heat in the supercritical regions of refrigerant. Supercritical refrigerants in gas coolers have a large temperature glide and substantial nonlinear variation in specific heat capacity vs. temperature. Closely matching the refrigerant glide temperature and the heat sink temperature profile greatly impacts the heat transfer characteristic of gas coolers and the overall performance of HTHPs. This study conducts a pinch point analysis for the gas cooling process of supercritical R1336mzz(Z) in HTHPs. A finite volume element model of a supercritical R1336mzz(Z) counterflow gas cooler is built and solved. This study evaluates the influences of operating conditions, including inlet and outlet of coolants, refrigerant evaporation temperature and superheat degree, pinch temperature difference, and heat rejection pressure, on the performance of HTHPs. The optimal discharge pressures in gas coolers are proposed for industrial spray dryers in providing drying air at 170°C−210°C. The results of the present study help design gas coolers in transcritical R1336mzz(Z) HTHPs.

Wang, Pengtao↗

JSPEC: A Program for IBS and Electron Cooling Simulation

Intrabeam scattering is an important collective effect that can deteriorate the properties of a high-intensity beam, and electron cooling is a method to mitigate the IBS effect. JSPEC (JLab Simulation Package for Electron Cooling) is an open-source program developed at Jefferson Lab, which simulates the evolution of the ion beam under the IBS and/or the electron cooling effect. JSPEC has been benchmarked with BETACOOL and experimental data. In this report, we will introduce the features of JSPEC, including the friction force calculation, the IBS expansion rate and electron cooling rate calculation, and the beam-dynamic simulations for the electron cooling process; explain how to set up the simulations in JSPEC; and demonstrate the benchmarking results.

Zhang, He↗

Evaluating MetGlasTM Solderability with Tin-Silver-Copper and Tin-Silver-Bismuth Solder Alloys

The solderability of MetGlas TM (subsidiary of Hitachi Metals, America Ltd) 2826 MB, a rapidly solidified metallic foil, was evaluated by the meniscus height/wetting force method for tin-silver-copper (SnAgCu) and tin-silver-bismuth (SnAgBi) solders to understand the effects of the extreme non-equilibrium condition of the MetglasTM surface on solderability performance. Of the variables studied here (solder temperature, heat treatment, and solder composition), solder composition had the largest impact on contact angle. Flux and foil composition remained constant throughout; but, these factors would also be predicted to significantly affect solderability. A greater understanding of the manner whereby non-equilibrium cooling affects solderability of these foils will broaden the application of soldering technology of structures fabricated by rapid cooling process (i.e. additively manufactured coatings and parts). Developing a robust database for Pb-free solderability behavior is also necessary, as industry transitions from tin-lead (SnPb) to lead free (Pb-free) solders.

36 MATERIALS SCIENCE↗

The Structure of Liquid and Glassy Carbamazepine

To enhance the solubility of orally administered pharmaceuticals, liquid capsules or amorphous tablets are often preferred over crystalline drug products. However, little is known regarding the variation in bonding mechanisms between pharmaceutical molecules in their different disordered forms. In this study, liquid and melt-quenched glassy carbamazepine have been studied using high energy X-ray diffraction and modeled using Empirical Potential Structure Refinement. The results show significant structural differences between the liquid and glassy states. The liquid shows a wide range of structures; from isolated molecules, to aromatic ring correlations and NH-O hydrogen bonding. Upon quenching from the liquid to the glass the number of hydrogen bonds per molecule increases by ~50% at the expense of a ~30% decrease in the close contact (non-bonded) carbon-carbon interactions between aromatic rings. During the cooling process, there is an increase in both singly and doubly hydrogen-bonded adjacent molecules. Although hydrogen-bonded dimers found in the crystalline states persist in the glassy state, the absence of a crystalline lattice also allows small, hydrogen-bonded NH-O trimers and tetramers to form. This proposed model for the structure of glassy carbamazepine is consistent with the results from vibrational spectroscopy and nuclear magnetic resonance.

Benmore, Chris J. (ORCID:0000000170077749)↗

Implementation of Chemistry in the Athena++ Code

Chemistry plays a key role in many aspects of astrophysical fluids. Atoms and molecules are agents for heating and cooling, determine the ionization fraction, serve as observational tracers, and build the molecular foundation of life. We present the implementation of a chemistry module in the publicly available magnetohydrodynamic code Athena++ . We implement several chemical networks and heating and cooling processes suitable for simulating the interstellar medium (ISM). A general chemical network framework in the KIDA format is also included, allowing users to easily implement their own chemistry. Radiation transfer and cosmic-ray ionization are coupled with chemistry and solved with the simple six-ray approximation. The chemical and thermal processes are evolved as a system of coupled ordinary differential equations with an implicit solver from the CVODE library. We perform and present a series of tests to ensure the numerical accuracy and convergence of the code. Many tests combine chemistry with gas dynamics, including comparisons with analytic solutions, 1D problems of the photodissociation regions and shocks, and realistic 3D simulations of the turbulent ISM. We release the code with the new public version of Athena++ , aiming to provide a robust and flexible code for the astrochemical simulation community.

79 ASTRONOMY AND ASTROPHYSICS↗

Fiber and bundle orientations, matrix rich regions, and mechanical properties of fiber reinforced composites using thermal digital image correlation

Methods for assessing fiber and bundle orientations and mechanical properties of fiber reinforced composite materials using Thermal Digital Image Correlation (TDIC) are disclosed. In some examples, the method comprises exposing the composite material to a temperature change; imaging the composite material at a plurality of time points before, during and/or after the temperature change; and assessing the characteristic of the composite material based on the imaging. In others, temperature changes naturally occur during the cooling process after manufacturing can be employed for this method such as compression molding process, injection molding process, resin transfer molding processes and its variants.

36 MATERIALS SCIENCE↗

helios: An R package to process heating and cooling degrees for GCAM

helios is an open-source R package that estimates population-weighted heating and cooling degree-hours (HDH and CDH) and degree-days (HDD and CDD) at various temporal (e.g., energy dispatch segments, monthly, yearly) and spatial scales (e.g., U.S. states, global political regions, countries). The degree hour and degree day outputs from helios are used to inform electricity demand load in the Global Change Analysis Model (GCAM) as well as in GCAM-USA (which is the version of GCAM with U.S. state-level details). helios uses a workflow with four steps: processing raw data; calculating heating and cooling degrees; visualizing performance diagnostics; and outputing results in various formats. There are two sources of widely-used climate data compatible with helios: (1) hourly climate data with 12-km resolution that are dynamically downscaled with the Weather Research and Forecasting (WRF) model and projected using a thermal global warming (TGW) approach; and (2) daily climate data with 0.5-degree resolution from the Coupled Model Intercomparison Project (CMIP) that is bias-adjusted and statistical downscaled by the Inter-Sectoral Impact Model Intercomparison Project (ISIMIP). In summary, helios is a model that standardizes methodology of heating and cooling degrees-hours and degree-days using publicly available data and advance the understanding of the impact of spatial and temporal temperature variability on building energy services.

97 MATHEMATICS AND COMPUTING↗

U-gas +Cool GTL™ - A New Integrated Process for Direct Biomass Conversion to Liquid Fuels

The U-Gas gasification technology, marketed by Sungas, is a proven fluid bed gasification technology for biomass conversion. U-Gas has been tested on a wide variety of biomass feeds including wood and waste streams. The U-Gas Technology has successfully converted wood for more than 20 years in a gasification plant in Skive Denmark at the 150t/d size. GTI has also recently developed the Cool GTL process for converting biogas to high quality gasoline, jet, and diesel fuels. The technoeconomics and LCA for the combination of the two technologies results an integrated optimized process, which will be discussed. The Cool GTL process is still in development and the development should be complete by 2023. Cool GTL converts high CO2 content feeds to synthesis gas with a 2-2.4/1 H2/CO ratio suitable for fuels synthesis. The process is based on a novel, highly stabile CO2/steam reforming catalyst. The 2.0-2.4/1 H2/CO synthesis gas ratio is always achieved, independently of feed CO2 content, by adjusting the amount of water added according to the amount of CO2 in the feed. The reformer catalyst has been tested for 500 hours and shows no measurable deactivation. The product from the reformer then goes directly to a low temperature slurry bed Fischer Tropsch reactor with an integrated finishing hydroisomerization reactor which makes hydrocarbon liquids from the synthesis gas. With this configuration no wax is produced. The technoeconomics and carbon intensity for the integration of UGas and the Cool GTL processes will be compared to other biomass conversion approaches. The use of electrolysis to boost H2 in the feed and increase liquid production will also be analyzed as a potential process improvement with sensitivities to the cost of electricity and the use of renewable electricity.

09 BIOMASS FUELS↗

Fitness For Service Assessment of a Corroded Heat Exchanger

Within the Fermi National Accelerator complex, there exist various water systems that support accelerator operations. One of these systems is extremely vital to the operation of the machine; that is the cooling system. The cooling system consists of nine relatively large heat exchangers that take untreated pond water and use it to cool the process fluid that further cools machine components. Over the 30 years these heat exchangers have been in operation, they have undergone significant material loss on the channels. This material loss, due to various forms of corrosion such as galvanic and microbiologically influenced corrosion (MIC) and possibly others, has deteriorated more than 80% of the nominal wall thickness of some of the exchangers and placed them in a questionable state. ASME FFS-1 (API 579) has been applied to address the condition of the heat exchangers due to their noncompliance with the governing code, BPVC Sec. VIII Div. 1. The assessments encompassed ASME FFS-1 parts 4: General Metal Loss and 9: Crack Like Flaw using level 1, 2, and 3 analysis techniques based on inspection data obtained by API 510 inspections. Level 1 and 2 assessments were deemed unfit for the corroded regions due to their location relative to a major structural discontinuity (channel to tube-sheet joint), so a level 3 analysis was conducted according to ASME Sec. VIII Div. 2 (design by analysis) rules for pressure vessels. Supplemental information included pond water tests to determine an accurate future corrosion allowance due to lacking inspection history. A leak before break (LBB) route was chosen to evaluate the possibility of leaking prior to the onset of failure. The analysis of one heat exchanger shows that the possibility the channel will develop a pinhole leak over 2.5 more years of operation should not be overlooked, but burst was unlikely from operation. The use of fracture mechanics show, that if a through-wall crack were to develop, it would not propagate further than the channel geometry and cause a leak not greater than 35 GPM. Using ASME Section XI Code Case N-705-1, allowing us to operate with a leak until the next outage given certain operating conditions and developing a leak mitigation procedure, this heat exchanger is deemed fit-for-service.

Humenik, Alex [Fermilab]↗

Estimating outflow masses and velocities in merger simulations: Impact of r -process heating and neutrino cooling

Here, the determination of the mass, composition, and geometry of matter outflows in black hole-neutron star and neutron star-neutron star binaries is crucial to current efforts to model kilonovae and to understand the role of neutron star merger in r-process nucleosynthesis. In this manuscript, we review the simple criteria currently used in merger simulations to determine whether matter is unbound and what the asymptotic velocity of ejected material will be. We then show that properly accounting for both heating and cooling during r-process nucleosynthesis is important to accurately predict the mass and kinetic energy of the outflows. These processes are also likely to be crucial to predict the fall-back timescale of any bound ejecta. We derive a model for the asymptotic velocity of unbound matter and binding energy of bound matter that accounts for both of these effects and that can easily be implemented in merger simulations. We show, however, that the detailed velocity distribution and geometry of the outflows can currently only be captured by full three-dimensional fluid simulations of the outflows, as nonlocal effect ignored by the simple criteria used in merger simulations cannot be safely neglected when modeling these effects. Finally, we propose the introduction of simple source terms in the fluid equations to approximately account for heating/cooling from r-process nucleosynthesis in future seconds-long three-dimensional simulations of merger remnants, without the explicit inclusion of out-of-nuclear statistical equilibrium reactions in the simulations.

79 ASTRONOMY AND ASTROPHYSICS↗

Modular Adaptive Packing for Integrally Cooled Absorbers

Process intensification is one cornerstone in ION Clean Energy’s (ION) efforts to lowering CO2 capture cost. ION has modeled, designed, and fabricated an innovative gas-liquid contactor known as Modular Adaptive Packing (MAP). During two successful SBIR Phase I and II projects entitled: “Rapid Design and Testing of Novel Gas-Liquid Contacting Devices for Post-Combustion CO2 Capture via 3D-printing”, ION developed and proved this new technology at bench scale. MAP, a 3D-printed lattice-structured packing, combines the absorber gas/liquid contactor with an innovative in-situ heat-exchanger. Thanks to the capabilities of 3D-printing, the lattice structure of MAP contains hollow channels through which coolant water can be pumped to remove the heat of reaction from CO2 absorption. ION refers to this novel method of heat exchange as intracooling. After 25.4 cm (10 in) diameter MAP modules were fabricated, ION built and tested a packing characterization rig at its pilot facility in Boulder, Colorado, U.S.A. To provide baseline results for the characterization rig, ION tested Sulzer’s Mellapak™ 250Y (MP250Y) as a standard structured packing. ION’s MAP was then compared directly to the baseline MP250Y packing to evaluate key indicators including pressure drop, liquid hold-up, and effective area. MAP has a higher pressure drop than MP250Y at the same gas velocities in addition to greater liquid holdup. However, ION found that MAP displays a higher wetting coverage of 93% compared to 65% for MP250Y and reduces shearing forces that result in undesirable droplet formation. Using Optimized Gas Treating’s (OGT) rate-based simulation software ProTreat®, a conceptual evaluation of MAP was modeled for a CO2 absorber using 30 wt% MEA solvent over a range of lean loadings at 90% CO2 capture from a coal-fired power plant. ION modeled a 25-meter column absorber for both the standard MP250Y packing and a hybrid column. The hybrid absorber contained 10 m of MP250Y packing at the top and bottom with the middle 5 meters comprised of MAP. Compared to a traditional intercooled absorber, MAP can remove 22% more heat and increase overall MEA carrying capacity by 4% without increasing overall pressure drop.

20 FOSSIL-FUELED POWER PLANTS↗

Optimal Design of Intensified Towers for CO2 Capture with Internal, Printed Heat Exchangers

Solvent-based carbon capture processes typically suffer from the temperature rise of the solvent due to the heat of absorption of CO2. This increased temperature is not thermodynamically favor-able and results in a significant reduction in performance in the absorber column. As opposed to interstage coolers, which only remove, cool, and return the solvent at discrete locations in the column, internal coolers that are integrated with the packing can cool the process inline, which can result in improved efficiency. This work presents the modeling of these internal coolers within an existing generic, equation-oriented absorber column model that can cool the process while allowing for simultaneous mass transfer. Optimization of this model is also performed, which is capable of optimally choosing the best locations to place these devices, such that heat removal and mass transfer area are balanced. Results of the optimization have shown that optimally placed cooling elements result in a significant increase in the capture efficiency of the process, compared to a similar column with no internal cooling, with a common trend being the cooling of the column in the temperature bulge region. It is observed that by optimally placing an internal cooler, the solvent flow rate can be decreased, and the CO2 lean loading can be increased while still maintaining the same efficiency. These process changes can lead to a substantial reduction in costs due to lower reboiler duty.

Summits, Stephen↗

Internally-cooled compressor diaphragm

An internally-cooled diaphragm for an internally-cooled compressor is provided. The internally-cooled diaphragm may include an annular body configured to cool a process fluid flowing through a fluid pathway of the internally-cooled compressor. The annular body may define a return channel of the fluid pathway, and a cooling pathway in thermal communication with the fluid pathway. The return channel may be configured to at least partially diffuse and de-swirl the process fluid flowing therethrough, and the cooling pathway may be configured to receive a coolant to absorb heat from the process fluid flowing through the return channel.

42 ENGINEERING↗

Package Data for CERF-Data Centers

This dataset contains sample input 100m resolution raster files for running the CERF-DC python package (see https://github.com/IMMM-SFA/cerf_data_centers) at the state level across the CONUS. Due to data availability constraints, some of the items included in this dataset are proxies or assumptions for siting factors used in the model. These are individually noted in the item descriptions and can be exchanged with more detailed information upon availability. Data Descriptions The following raster files are included in the data download: state_siting_region.tif — State areas identified by state FIPS code composite_siting_suitability.tif — Value of 1 indicates suitable siting location, 0 otherwise. The following areas are excluded from siting: Areas within 300m of a federal airport runway Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory Protected Areas Database of the United States (PAD-US) areas Railroads, major roadways, and minor roadways Military areas and training grounds Developed lands Areas >0.8 km (0.5 miles) from developed lands land_value_dollar_per_sqft.tif — USD per square foot (sqft) derived from USDA $/acre land cost personal_property_tax_rate.tif — Personal property tax rate by state. Uses an assumed 0.0125 personal property tax rate for states with personal property tax, 0 for states without personal property tax. real_property_tax_rate.tif — Real property tax rate. Based on county level residential real estate property tax rates. sales_tax_rate.tif — Sales tax rate by state. mechanical_cooling_fraction.tif — Fraction of year (values between 0 and 1, inclusive) that the data center would be cooled through mechanical processes based on local water stress and humidity levels. water_cooling_fraction.tif — Fraction of year (values between 0 and 1, inclusive) that the data center would be cooled through evaporative (water cooled) processes based on local water stress and humidity levels. distance_to_substation.tif — Distance to nearest substation in hundreds of meters (i.e., value of 1 equals a distance of 100m). Offshore areas have a value of 0. industrial_electricity_rates_dollar_per_kwh.tif — USD/kWh industrial electricity rates. Represents the average industrial rate across all utilities that operate within a given county. Values are derived from the US Utility Rate Database. commercial_electricity_rates_dollar_per_kwh.tif — USD/kWh commercial electricity rates. Represents the average commercial rate across all utilities that operate within a given county. Values are derived from the US Utility Rate Database. data_center_market_locations.tif — Grid cells with positive values represent the centroid of existing data center market clusters. The value of non-zero grid cells represents the number of data centers in the market cluster. All other grid cells have a value of 0. Geospatial Metadata CRS: Albers Equal Area Conic (ESRI:102003) Extent: -2415585.0000000023283064,-1441981.2605773280374706 : 2384414.9999999976716936,1708018.7394226719625294 Dimensions: X: 48000 Y: 31500 Bands: 1 Origin: -2415585.0000000023283064,1708018.7394226719625294 Pixel Size: 100,-100 Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall↗