Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pressure injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Ignition delays, heats of combustion, and reaction rates of aluminum alkyl derivatives used as ignition and combustion enhancers for supersonic combustors

The work was based on adapting an apparatus and procedure developed at Southwest Research Institute for rating the ignition quality of fuels for diesel engines. Aluminum alkyls and various Lewis-base adducts of these materials, both neat and mixed 50/50 with pure JP-10 hydrocarbon, were injected into the combustion bomb using a high-pressure injection system. The bomb was pre-charged with air that was set at various initial temperatures and pressures for constant oxygen density. The ignition delay times were determined for the test materials at these different initial conditions. The data are presented in absolute terms as well as comparisons with the parent alkyls. The relative heats of reaction of the various test materials were estimated based on a computation of the heat release, using the pressure data recorded during combustion in the bomb. In addition, the global reaction rates for each material were compared at a selected tmperature and pressure.

Ryan, T. W., III↗

Combustion Stability Characteristics of the Project Morpheus Liquid Oxygen / Liquid Methane Main Engine

The project Morpheus liquid oxygen (LOX) / liquid methane (LCH4) main engine is a Johnson Space Center (JSC) designed ~5,000 lbf-thrust, 4:1 throttling, pressure-fed cryogenic engine using an impinging element injector design. The engine met or exceeded all performance requirements without experiencing any in- ight failures, but the engine exhibited acoustic-coupled combustion instabilities during sea-level ground-based testing. First tangential (1T), rst radial (1R), 1T1R, and higher order modes were triggered by conditions during the Morpheus vehicle derived low chamber pressure startup sequence. The instability was never observed to initiate during mainstage, even at low power levels. Ground-interaction acoustics aggravated the instability in vehicle tests. Analysis of more than 200 hot re tests on the Morpheus vehicle and Stennis Space Center (SSC) test stand showed a relationship between ignition stability and injector/chamber pressure. The instability had the distinct characteristic of initiating at high relative injection pressure drop at low chamber pressure during the start sequence. Data analysis suggests that the two-phase density during engine start results in a high injection velocity, possibly triggering the instabilities predicted by the Hewitt stability curves. Engine ignition instability was successfully mitigated via a higher-chamber pressure start sequence (e.g., ~50% power level vs ~30%) and operational propellant start temperature limits that maintained \cold LOX" and \warm methane" at the engine inlet. The main engine successfully demonstrated 4:1 throttling without chugging during mainstage, but chug instabilities were observed during some engine shutdown sequences at low injector pressure drop, especially during vehicle landing.

Melcher, John C.↗

Photomicrographic Studies of Fuel Sprays

A large number of photomicrographs of fuel sprays were taken for the purpose of studying the spray structure and the process of spray formation. They were taken at magnifying powers of 2.5, 3.25, and 10, using a spark discharge of very short duration for illumination. Several types and sizes of nozzles were investigated, different liquids were used, and a wide range of injection pressures was employed. The sprays were photographed as they were injected into a glass-walled chamber in which the air density was varied from 14 atmospheres to 0.0013 atmosphere.

Lee, Dana W↗

Experimental Investigation of Low-Frequency Distributed Acoustic Strain-Rate Responses to Propagating Fractures

Summary Low-frequency distributed acoustic sensing (LF-DAS) responds to strain changes due to far-field fracture propagation. To better understand the LF-DAS response to fracture propagation, we performed laboratory-scale hydraulic fracture experiments with embedded optical strain sensors. The objectives of this research are to generate hydraulic fractures of known geometry, measure the strain response along the embedded fiber-optic cable comparable to LF-DAS measurements, and use the results to inform the interpretation of field-derived LF-DAS data. The experiments were conducted in unconfined transparent cubic blocks with a dimension of 8 in. on each side. The block was made of transparent epoxy to visualize the fracture propagation. Fiber-optic sensing cables were embedded in the block at different distances to the source of injection. We injected dyed water through an injection tubing to generate a transverse, radial fracture along an initial flaw. An optical interrogator recorded the response of offset fiber Bragg grating (FBG) strain sensors normal to the plane of the fracture. The strain data were visualized on a waterfall plot, akin to visualizations of field-derived LF-DAS data. Dimensional analysis was used to scale the laboratory results to field conditions. We compared the evolution of the strain response at the fiber-optic cable, injection pressure, and rate with known fracture geometry. The measured strains were compared with Sneddon’s (1946) linear elastic solution for a penny-shaped crack and found to follow this behavior. The generated radial fractures in transparent media can be modeled with Sneddon’s linear elastic radial fracture model and a Mode I critical stress intensity factor. The LF-DAS characteristic response of a narrowing region of extension surrounded by compression was exhibited as a fracture that approached and intersected the fiber-optic cable. The experimentally derived strain and strain-rate waterfall plots with known fracture geometry, injection rate, and pressure response provide insight in understanding LF-DAS responses in the field. Furthermore, we developed a method to estimate fracture geometry evolution from the fiber-optic strain data and validated the method against the experimental data.

Engineering↗

Applying colloidal silica suspensions injection and sequential gelation to block vertical water flow in well annulus: laboratory testing on rheology, gelation, and injection

We evaluated the application of silica suspension injection and sequential gelation to block vertical water flow in the annuli of long-screened wells. First, we studied the viscosity, rheological behavior, and gelation performance of colloidal silica suspensions in batch tests. Then, we tested the injection of silica suspensions and the water flow blocking efficiency of the later formed silica gel in column and bench-scale sandbox experiments. Micron-sized fumed powder silica suspensions and nanosized silica suspensions recovered from geothermal fluids were tested in this work. Fumed silica suspensions showed shear thinning, while nanosized silica suspensions exhibited Newtonian flow behavior. During the gelation process, the nanosized silica suspension changed from a Newtonian fluid to a shear thinning fluid while increasing its overall viscosity. At comparable concentrations, the nanosized silica suspensions have much lower viscosity than that of the fumed silica suspensions. Increases in the Na + concentration and silica particle concentration in these suspensions shortened the gelation time. Silica suspension gelation in sand columns completely blocked the water flow and sustained the injection pressure up to 50 psig (344.7 kPa). A silica suspension was successfully injected into the target zone in the annulus of a bench-scale sandbox mimicking long-screened wells in the field. The silica gel formed in the annulus effectively blocked chemical transport through the gelled zone. Our research reveals that a process using silica suspension injection and sequential gelation technology is promising for blocking the vertical water flow and chemical transport through the filter pack in targeted zones within the annulus of long-screened well systems.

54 ENVIRONMENTAL SCIENCES↗

Coefficients of discharge of fuel-injection nozzles for compression-ignition engines

This report presents the results of an investigation to determine the coefficients of discharge of nozzles with small, round orifices of the size used with high-speed compression-ignition engines. The injection pressures and chamber back pressures employed were comparable to those existing in compression-ignition engines during injection. The construction of the nozzles was varied to determine the effect of the nozzle design on the coefficient. Tests were also made with nozzles assembled in an automatic injection valve, both with a plain and with a helically grooved stem. It was found that a smooth passage before the orifice is requisite for high flow efficiency. A beveled leading edge before the orifice gave a higher coefficient of discharge than a rounded edge. The results with the nozzles assembled in an automatic injection valve having a plain stem duplicated those with the nozzles assembled at the end of a straight tube of constant diameter. Lower coefficients were obtained with the nozzles assembled in an injection valve having a helically grooved stem. When the coefficients of nozzles of any one geometrical shape were plotted against values of corresponding Reynold's numbers for the orifice diameters and rates of flow tested, it was found that experimental points were distributed along a single curve.

Gelalles, A G↗

Combustion Stability Characteristics of the Project Morpheus Liquid Oxygen/Liquid Methane Main Engine

The Project Morpheus liquid oxygen (LOX) / liquid methane rocket engines demonstrated acousticcoupled combustion instabilities during sea‐level ground‐based testing at the NASA Johnson Space Center (JSC) and Stennis Space Center (SSC). High‐amplitude, 1T, 1R, 1T1R (and higher order) modes appear to be triggered by injector conditions. The instability occurred during the Morpheus‐specific engine ignition/start sequence, and did demonstrate the capability to propagate into mainstage. However, the instability was never observed to initiate during mainstage, even at low power levels. The Morpheus main engine is a JSC‐designed ~5,000 lbf‐thrust, 4:1 throttling, pressure‐fed cryogenic engine using an impinging element injector design. Two different engine designs, named HD4 and HD5, and two different builds of the HD4 engine all demonstrated similar instability characteristics. Through the analysis of more than 200 hot fire tests on the Morpheus vehicle and SSC test stand, a relationship between ignition stability and injector/chamber pressure was developed. The instability has the distinct characteristic of initiating at high relative injection pressure drop (dP) at low chamber pressure (Pc); i.e., instabilities initiated at high dP/Pc at low Pc during the start sequence. The high dP/Pc during start results during the injector /chamber chill‐in, and is enhanced by hydraulic flip in the injector orifice elements. Because of the fixed mixture ratio of the existing engine design (the main valves share a common actuator), it is not currently possible to determine if LOX or methane injector dP/Pc were individual contributors (i.e., LOX and methane dP/Pc typically trend in the same direction within a given test). The instability demonstrated initiation characteristic of starting at or shortly after methane injector chillin. Colder methane (e.g., sub‐cooled) at the injector inlet prior to engine start was much more likely to result in an instability. A secondary effect of LOX sub‐cooling was also possibly observed; greater LOX sub‐ cooling improved stability. Some tests demonstrated a low‐amplitude 1L‐1T instability prior to LOX injector chill‐in. The Morpheus main engine also demonstrated chug instabilities during some engine shutdown sequences on the flight vehicle and SSC test stand. The chug instability was also infrequently observed during the startup sequence. The chug instabilities predictably initiated at low dP/Pc at low Pc. The chug instabilities were always self‐limiting; startup chug instabilities terminated during throttle‐up and shutdown chug instabilities decayed by shutdown termination.

Melcher, J. C.↗

Numerical simulation of X-ray-heated winds in Seyfert galaxies. I - The case of zero angular momentum

Numerical hydrodynamics simulations are presented of X-ray heated winds believed to form the 'mirrors' which reflect light from obscured Seyfert galaxy nuclei into our line of sight. Above a likely range of parameters, it is shown that steady state flows are created when a cool torus surrounds an AGN. Some of the mass evaporated off the inner edge of the torus is captured by the central gravitational well, while the rest is driven off in a warm wind. When the central gravity is strong relative to the radiative heating rate, i.e., L/L(E) is small, nearly all the injected matter is captured. When the gravity is weaker, a given combination of heating rate and injected pressure leads to a maximum mass loss rate; when the rate at which mass is injected exceeds this amount, the excess is captured. The dividing line between these two cases comes at L/L(E) = about 0.08.

Balsara, Dinshaw S.↗

EGS Collab Experiment 1: Circulation Testing Processed data

This submission includes processed and reduced data for circulation testing that was conducted at the 164' fracture on the 4850 ft level of the Sanford Underground Research Facility. The circulation tests were done to test the flow through the 164' fracture in the EGS Collab Experiment 1 testbed on the 4850 ft level of the Sanford Underground Research Facility in order to validate computer models concerned with flow processes and heat exchange processes in EGS. This data was processed from raw data that is available in the GDR submission linked below: "EGS Collab Circulation Testing Raw Data and Documentation." Python scripts used to process and reduce the data are included. The scripts also serve as "documentation" as well as examples for data processing. More information about the test itself as well as the rationale and process of data processing is available at wiki page linked below.

15 GEOTHERMAL ENERGY↗

Experimental Study of Transport Behavior of Swellable Microgel Particles in Superpermeable Channels for Conformance Control

Summary Gel treatment is an effective way to attack excessive water production during oil development. The transport behavior of gel materials in reservoirs is of crucial importance to the effectiveness of gel treatments. The aim of this paper is investigating the transport behavior of swellable micrometer-sized preformed particle gels (PPGs, or microgels) through superpermeable (super-K) channels. Sandpacks with permeabilities ranging from 27 to 221 darcies were used to mimic the super-K channels. Multiple pressure sensors were applied along the sandpack models to monitor the propagation behavior of the microgels. The tested microgel particles could transport through the super-K channels, and a higher driving pressure gradient was required when the particle/pore size ratio was larger. The pressure gradient distribution along the super-K channels was relatively uniform when the particle/pore ratio was low (less than 1.3). However, the inlet section would show increasingly higher pressure gradients as the particle/pore ratio was increased, indicating increased difficulty in propagation. The propagation of the gel particles was significantly slower compared with the carrying fluid. The delayed propagation behavior was more pronounced when the particle/pore ratio was higher. The injection pressure was much less sensitive to the injection flow rate compared with a Newtonian fluid. The gel dispersion exhibited an apparent shear thinning (pseudoplastic) behavior when transporting through the porous channels. Breakage of the gel particles was observed especially at high superficial velocities. The particle breakage was partially responsible for the apparent shear thinning behavior. The breakage phenomenon was in favor of deep placement of the gel particles. The channel permeabilities were significantly reduced by the microgels, bringing sufficient resistance to subsequent waterflooding (more than 99.5%). At given matching size conditions, softer gels were more likely to establish in-depth placement and uniform water blocking capacity in the channels. The microgel particles exhibited salinity-responsive behavior to the post-brine flush. The gel particles could shrink and reswell according to the salinity of the injected water. Possibilities were discussed to use this salinity-responsive behavior. Also, the microgels exhibited a particular disproportionate permeability reduction (DPR) effect. After gel injection, the channel permeability to water flow was reduced by more than 20 to 92 times of the permeability to oil flow. This work provides important support to understand the transport behavior of gel particles in super-K channels. The achievements are helpful for gel product selection and gel treatment design.

Engineering↗

An Experimental Investigation of Supercritical Methane Injection Characteristics in a CO2 Environment

Abstract Clean energy generation is gaining significant attention from industries, academia, and governments across the globe. The Allam cycle is one such technology that has been under focus due to its efficiency, environmental friendliness, and economics. This is a direct-fired cycle operating at supercritical conditions using carbon dioxide as a working fluid. Fuel or oxidizer jet mixing with CO2 is a vital phenomenon that governs combustion efficiency, and it is not well understood for the Allam cycle conditions. This paper experimentally investigated the jet characteristics of a methane jet injected into a subcritical to supercritical carbon dioxide environment. A wide range of injection pressures and temperatures were targeted between subcritical to supercritical conditions. Unlike previous studies, the current work focused on injecting lower-density (methane) jets into higher-density (carbon dioxide) environments. Schlieren imaging and methane absorption measurements were simultaneously performed with a CMOS high-speed camera and a 3.39 μm infrared laser. Specifically, we looked at the classical injection parameter of jet spreading angle, which was classically established to be mainly a density ratio function. Here, the jet cone angle was obtained from the postprocessed schlieren imaging. The jet cone angle is a critical characteristic parameter that describes the entrainment rate in a jet; thus, it is a crucial parameter in understanding the nature of the jet. The laser measurements were only used as an additional check to confirm the entry time of methane into the chamber filled with carbon dioxide. Notably, this paper makes a detailed comparison between the jet cone angles of jets with a density ratio. The result showed that the classical correlations, such as Abramovich's theory applied to submerged turbulent gas jets developed for low-density ratio jets, were unsuitable for higher-density ratio jets. It was also observed that the divergence angles were dependent not only on density ratio but also on other parameters such as pressure ratios and reduced pressures.

Engineering↗

EGS Collab Experiment 2: Hydraulic Pressure Test Results

The EGS Collab experiment 2 was focused on testing shear stimulation techniques. Shear stimulation, in this case, means using hydraulic pressure to cause shear slip on preexisting fracture or fault planes such that the hydraulic conductivity of the fracture or fault increases. The concept is to create a percolating network of permeable fractures by enhancing the permeability of a primarily preexisting network of fractures. To test this concept the hydraulic pressures for experiment 2 were kept below the the estimated magnitude of the least compressive principal stress based on a set of stress measurements in nearby well TV4100. All tests for experiment 2 were performed by applying hydraulic pressure to well E2-TC. Subsequent stimulations in both E2-TC and E2-TU where the injection pressure was increased above the least compressive principal stress are considered part of experiment 3, which is documented separately. The data are organized in directories labeled by the depth range isolated between packers.

15 GEOTHERMAL ENERGY↗

Progress of Gas Injection EOR Surveillance in the Bakken Unconventional Play—Technical Review and Machine Learning Study

Although considerable laboratory and modeling activities were performed to investigate the enhanced oil recovery (EOR) mechanisms and potential in unconventional reservoirs, only limited research has been reported to investigate actual EOR implementations and their surveillance in fields. Eleven EOR pilot tests that used CO2, rich gas, surfactant, water, etc., have been conducted in the Bakken unconventional play since 2008. Gas injection was involved in eight of these pilots with huff ‘n’ puff, flooding, and injectivity operations. Surveillance data, including daily production/injection rates, bottomhole injection pressure, gas composition, well logs, and tracer testing, were collected from these tests to generate time-series plots or analytics that can inform operators of downhole conditions. A technical review showed that pressure buildup, conformance issues, and timely gas breakthrough detection were some of the main challenges because of the interconnected fractures between injection and offset wells. The latest operation of co-injecting gas, water, and surfactant through the same injection well showed that these challenges could be mitigated by careful EOR design and continuous reservoir monitoring. Reservoir simulation and machine learning were then conducted for operators to rapidly predict EOR performance and take control actions to improve EOR outcomes in unconventional reservoirs.

Energy & Fuels↗

Single and Multi-Node Modeling of Direct, Submerged, and Self-Pressurization of A Cryogenic Propellant Tank Using Nodal Tools

The pressurization of cryogenic propellant tanks will always be an important process so long as cryogenic liquids are being considered as fuel sources or used for other in-space applications. Pressure control of the tank ullage is necessary for managing propellant flowrates to an engine or a receiver tank, and modeling of the process is used to predict the pressurant requirements and the amount of propellant boiloff. Direct ullage pressurization is the more traditional approach to tank pressurization, as the physics are straight-forward, and ample test (flight) data have been collected and analyzed over the past several decades. Submerged injection pressurization is an alternate method for tank pressurization and has been shown to reduce pressurant requirements, subcool the propellant, and reduce the risk of ullage collapse. Additionally, the pressurant gas entering the ullage is usually much colder when using the submerged pressurization approach, resulting in reduced propellant boiloff. These benefits are at the expense of vaporizing a small percentage of the propellent. Both tank pressurization methods are viable options for current and future space missions, and it is important to have the capability of analyzing the tank ullage conditions for both approaches. Our previous work has demonstrated the development of a Generalized Fluid System Simulation Program (GFSSP) model, which contains a thermodynamic equilibrium heat and mass transfer subroutine capable of effectively analyzing both direct and submerged pressurization systems [1-2]. This subroutine has most recently been enhanced to include the non-equilibrium effect of pressurant dissolution into the propellant. To date the ullage has always been represented as a single node, and although the simulated single-node temperatures have good comparison with the volume-averaged ullage temperatures computed from test data, the physics of the thermal stratification in the ullage were never captured, and adjustment factors in the model were required. The purpose of this paper is to introduce the development of a multi-node ullage model using GFSSP and to discuss the improvements of the simulated ullage temperature distribution and its resulting effects on ullage heat transfer processes. Test data from the Cryogenic Propellant Storage and Transfer Engineering Developmental Unit (CPST EDU) was used for model validation. For additional comparison, a Thermal Desktop (TD) model was also developed to analyze the CPST EDU direct ullage pressurization tests using both a single node and multi-node approach. The model includes the direct pressurant line, vent line, fill/drain line, and a TD FloCAD Compartment. The TD FloCAD Compartment is employed to represent the liquid and ullage as single volumes inside the tank, to include a liquid/vapor interface, and to generate network level objects such as lumps (analogous to nodes in GFSSP), paths, and ties between the fluid and thermal elements. An established heat load on the model tank was leveraged from a pre-existing higher-fidelity model correlated to CPST EDU test data.

pressurization↗

Effect of Orifice Length-Diameter Ratio on Spray Characteristics

The effect of variations of orifice length to diameter ratio on spray characteristics was determined for a 0.014-inch and a 0.040-inch orifice for ratio of 0.5 to 4.0. The nozzles containing the orifices were mounted in an injection valve and tested with a plan stem and with a helically grooved stem. The injection pressure was varied from 4000 to 8000 pounds per square inch. The air density into which the fuel was sprayed was varied from the density obtained with a pressure of 60 pounds per square inch to the density obtained with a pressure of 250 pounds per square inch at room temperature. The tests showed that increasing the orifice length to diameter ratio with a plain stem in the injection valve causes the spray tip penetration first to decrease, reaching a minimum between a ratio of 1.5 and 2.5, and then to increase, reaching a maximum at a ratio greater than 3.5. The spray cone angle showed little change with variation of the ratio. With a helically grooved stem and small ratio of orifice area to groove area, the penetration at first shows little tendency towards a minimum; but as the time of injection is increased to 0.004 second, the penetration becomes a minimum at a ratio between 0.5 and 2.0.

Gellales, A G↗

Identifying geological structures through microseismic cluster and burst analyses complementing active seismic interpretation

At the Decatur carbon capture and storage site (IL, USA) CO 2 has been injected from 2011–2014 and from 2017 to present near the base of the Lower Mt. Simon Sandstone saline reservoir, resulting in microseismicity. Microseismicity is mainly located in the basement and distributed in distinct spatial clusters. The lack of significant impedance contrasts within the basement makes the interpretation of active-source seismic reflection data challenging, however, recent reprocessing allowed to resolve faults above and at the top of the basement. These faults generally do not coincide with the location of microseismic events and their continuation to the general depth of the seismic events cannot be assumed. This paper shows how the interpretation of the microseismicity can complement structural interpretations of active-source seismic reflection data. In particular, we analyze clusters and bursts (abrupt increases) of microseismicity, identify unresolved, smaller-scale weaknesses and extract statistical parameters. These parameters allow comparisons with the interpreted faults, and with fracture sets intercepted by boreholes. During injection at the Decatur site, the injection pressure was kept far below fracture pressure, nevertheless, seismic events were induced and spread far beyond the expected extent of the CO 2 plume. We argue that local stress transfers related to the CO 2 injection reactivated pre-existing fractures within the critically stressed basement. Finally, we conducted a slip tendency analysis for faults interpreted from active seismic, selected cluster, bursts and nodal planes from focal mechanisms to determine if the interpreted structures are optimally oriented with respect to the stress regime. Our results suggest that the orientation of fractures close to the injection well, generally shows slight deviations from the optimal orientation for slip. This might indicate either slight local deviations of the maximum horizontal stress azimuth from the average direction used in the analysis, or the lack of optimally oriented fractures at this location.

58 GEOSCIENCES↗

Systems and methods for geothermal energy storage

A method and system may be used for storing energy in a geothermal system and recovering both the stored energy as well as thermal energy on demand. The geothermal system may include injection and production wells that are hydraulically coupled in a geothermal energy reservoir that behaves as a confined reservoir system with thermal energy transferring to fluid injected into the injection well and removed via the production well. Injection flow rate, injection pressure, production flow rate, production backpressure, or fluid residence time may be managed to control energy consumption or energy generation profiles of the geothermal system. During an energy storage mode, the injection flow rate exceeds the production flow rate thereby storing energy in the geothermal reservoir. During an energy recovery mode, production backpressure is reduced thereby releasing the stored energy and electricity is generated by removing the thermal energy from the fluid in a heat engine.

Norbeck, Jack↗

Influence of ambient air pressure on effervescent atomization

The influence of ambient air pressure on the drop-size distributions produced in effervescent atomization is examined in this article. Also investigated are the effects on spray characteristics of variations in air/liquid mass ratio, liquid-injection pressure, and atomizer discharge-orifice diameter at different levels of ambient air pressure. It is found that continuous increase in air pressure above the normal atmospheric value causes the mean drop-size to first increase up to a maximum value and then decline. An explanation for this characteristic is provided in terms of the various contributing factors to the overall atomization process. It is also observed that changes in atomizer geometry and operating conditions have little effect on the distribution of drop-sizes in the spray.

Chen, S. K.↗