Radar Waveform Pulse Analysis Measurement System for High-Power GaN Amplifiers
No abstract available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract available
Systems and methods for voltage stability monitoring and active/reactive power support are disclosed herein. In some embodiments, a smart electric meter of an end user in a grid power system can measure the voltage supplied to the end user via the grid power system, and can analyze the voltage data to detect critical voltage characteristics. The critical voltage characteristics may indicate that a voltage collapse event is likely. The smart electric meter can further estimate a voltage stability margin based on the voltage data. If necessary, the smart electric meter can control an electrical power source and/or an electric appliance positioned at or near the end user to increase the voltage stability margin.
The tone noise generated when a fan ingests circumferentially distorted flow was studied by an experiment conducted with the Advanced Noise Control Fan at the NASA Glenn Research Center. The inflow was distorted by inserting cylindrical rods radially into the duct. The rods were arranged in circumferentially irregular patterns in three of the five configurations tested. Rods were held in place using a mounting ring with 30 equally spaced holes placed at an axial location one rotor chordlength upstream of the fan. Acoustic pressure was measured in the inlet and exhaust duct of the fan using the Rotating Rake fan tone measurement system. Sound power levels, calculated from the measured data, were plotted as a function of circumferential mode. An analytic description of the unsteady pressure distribution at the interaction plane between the stationary rods and the fan rotor is presented in a form suitable for representing the circumferentially irregularly placed rods. Terms in the analytical description for sound power were proven to be useful in determining the dominant circumferential modes measured in the experiment and the differences in mode power level between the configurations tested. Insight gained through this work will be useful in the development of tools to compute fan inflow distortion tone noise.
Miniature, low power, telemetry system that can be used with commercially available strain gage pressure transducers accurately measures pressure with a small implantable pressure cell and transmitter. The system has been used to date only with pressure transducers, but the circuit is equally applicable to any measurement using a strain gage sensor.
With the fast growth of renewable energy sources (RES), more and more uncertainties are involved and influencing the stable operation of power systems. Controlled islanding is the last measure to prevent power system blackouts, thus this paper aims to propose a novel model of system separation based on Online Coherency Identification and Adjustable Robust Optimization Programming (OCI-AROP) for minimizing load shedding considering the uncertainties of RES. First, Fuzzy C-Means (FCM) clustering method with F-statistics is utilized to identify the coherent generator groups with the frequency data measured by Phasor Measurement Units (PMUs). Then, the OCI-AROP model considering coherent group constraints, connectivity constraints and robustness constraints about RES are presented. Finally, the case studies on IEEE-39 bus system and WECC-179 bus system are employed to demonstrate the effectiveness of the proposed OCI-AROP model, and comparisons among the OCI-AROP model and the other models are also given to show its superiority.
The increasing complexity and power/energy demands of heterogeneous exascale systems, such as the Frontier supercomputer, present significant challenges for measuring and optimizing power consumption in applications. Current tools either lack the resolution to capture fine-grained power and energy measurements, fail to validate in-band measurements against out-of-band power sensors, or cannot integrate this information with application performance events in a scalable manner. This paper introduces a novel open-source performance toolkit that integrates extended PAPI components with Score-P plugins to enable in-band, fine-grained power and energy measurements, while also supporting validation using power meter measurements for both CPUs and GPUs. One key contribution is the ability to perform millisecond-level power and energy measurements for AMD MI250X GPUs, mapping them to application performance events within a single trace and measurement system that scales. Our toolkit combines coarse-grained measurements from cray_pm counters with high-resolution metrics from rocm_smi and RAPL, converting GPU instantaneous accumulated energy into power to capture both transient and steady-state power behavior, a capability often missed by out-of-band and monitoring tools. By mapping these metrics to specific application regions, developers can identify energy hotspots, address inefficiencies in GPU kernel execution, and validate in-band measurements against external measurements. We demonstrate the effectiveness of this approach through case studies using benchmarks such as GPU rocblas_sgemm, BLIS c_blas_dgemm, and rocHPL, highlighting the variability of the measurements and the impact of transient power spikes on kernel-level efficiency.
High-density synchrophasors provide valuable information for power grid situational awareness, operation and control. Unfortunately, due to factors including communication instability and hardware failure, their data quality can be greatly deteriorated by anomalies. Since the anomalies can impact the performance of the synchrophasor applications, it is of paramount significance to propose a model to detect anomalies in synchrophasor. In this study, a convolutional neural network model is established to detect and classify the anomalies in the synchrophasor measurements. Additionally, four types of anomalies observed in actual synchrophasors including erroneous patterns, random spikes, missing points and high-frequency interferences are considered in this study. The proposed model is extensively evaluated via field-collected measurements from the synchrophasor network in Jiangsu grid, China. The superior performance of the proposed model indicates the great potential of using deep learning for the detection of abnormal synchrophasor measurements.
A calorimetric measurement technique developed for NASA's Deep Space Network (DSN) transmitters that does not require data on the coolant's thermal parameters is described. Calibration of the measurement system is achieved by measuring the DC input power to the klystron and relating coolant temperature increases to this known power dissipation. Agreement between calorimetric and electrical measurements of total system power was good, the difference being less than 2 percent. The operation of the system was not greatly affected by the composition of the coolant, which was varied from pure water to 40 percent ethylene glycol by mass. Good accuracy was also shown at output power levels, which varied over a 3.6:1 range.
Here, this article introduces ways to identify dynamic system models using measurement data. In power system analysis, a static model represents the time-invariant input-output relationship of a system, while a dynamic model describes the behavior of the system over time. For example, how will a system transit from one steady-state operation point to another?
Power measurement errors due to the bandwidth of a power meter and the sampling of the input voltage and current of a power meter were investigated assuming sinusoidal excitation and periodic signals generated by a model of a simple chopper system. Errors incurred in measuring power using a microcomputer with limited data storage were also considered. The behavior of the power measurement error due to the frequency responses of first order transfer functions between the input sinusoidal voltage, input sinusoidal current, and the signal multiplier was studied. Results indicate that this power measurement error can be minimized if the frequency responses of the first order transfer functions are identical. The power error analysis was extended to include the power measurement error for a model of a simple chopper system with a power source and an ideal shunt motor acting as an electrical load for the chopper. The behavior of the power measurement error was determined as a function of the chopper's duty cycle and back EMF of the shunt motor. Results indicate that the error is large when the duty cycle or back EMF is small. Theoretical and experimental results indicate that the power measurement error due to sampling of sinusoidal voltages and currents becomes excessively large when the number of observation periods approaches one-half the size of the microcomputer data memory allocated to the storage of either the input sinusoidal voltage or current.
This report provides an introduction to selected graph theoretic topics with pertinence to the structural analysis of electric power grid and communication systems. We focus on methodologies for defining, scoring, and identifying connectivity, spectral, and bottleneckeness properties in graphs, as well as vertex and edge importance measures such as centrality. We apply these measures to power systems and communications graph data, discuss and visualize the results, and comment on computational aspects of these methods. We show that graph theoretic methods can provide useful insights into grid and communication network structure, leading to tools and methods that could be used by electric utility engineers to improve key grid and communication network characteristics, such as resilience and scalability.
Review of testing methods for solar-cell power systems, including measurements at table mountain test facility and in high-altitude balloon flight
The Phasor Measurement Unit (PMU) has revolutionized power system management by providing high-resolution, time-stamped, spatial, and temporal measure¬ments of the state of power systems. However, the standards defining the measured quantities have ambiguities that cause uncertainty, irreproducibility, and loss of interoperability during periods of change where the measurements should have the greatest value. This paper examines PMU frequency measurement to highlight the problems. It develops some suggestions for the scope and the next evolutionary improvements to the documentary standards. The aim is to improve the meaningfulness and trustworthiness of dynamic power system measurements.
As the penetration of inverter-based renewable energy resources increases in the power grid, especially at the distribution and microgrid levels, the need to accurately represent them in planning studies increases as well. However, due to the lack of well-established standard procedures, and vendor reluctance towards the detailed sharing of proprietary models, automated dynamic model validation and parameter calibration tools for inverter based resources (IBRs) remain scarce. This work presents a model validation and parameter calibration platform for representing IBRs with generic phasor-domain models. Phasor measurements of power system events are used for continuous validation using the data playback method, and model parameters are re-calibrated if a significant mismatch between measurements and model response is observed. Unique features of the proposed platform include- (a) an iterative Bayesian optimization approach towards parameter calibration to address a possible mismatch between the structures of generic models implemented in simulation softwares and actual commercial inverters, (b) error metrics designed to account for a possible mismatch between the time resolution of simulation and measurements, and (c) analysis of the measurement-simulation mismatch to provide guidance to engineering personnel regarding model shortcomings. The performance of the platform has been illustrated using both simulated data and field measurements to validate/calibrate inverter models in GridLAB-D.
The Advanced Test Reactor (ATR) at INL measures reactor power through various methods, two of them being thermal and Nitrogen-16 (N-16) activity. Water power calculator (WPC) is a thermal power system that measures flow and temperature to determine thermal quadrant powers. The N-16 system utilizes a beta detector that outputs Nitrogen activation levels to calculate lobe power through an algorithm called Lobe Power Calculation and Indication system (LPCIS). The LPCIS utilizes the N-16 system and the WPC system to determine reactor core power levels. The WPC provides accurate calculations of quadrant and total reactor thermal power. With the use of WPC measurements, thermal-to-N-16 (T2N) power ratios are produced to determine if the two indication systems agree on core power. Relative magnitude equations are used to utilize N-16 coefficients and multipliers to improve the indications of the LPCIS. These correct indications are crucial for maintaining safety limits because operators rely on this information for decision making. Currently, the LPCIS system uses linear equations and matrices to calculate lobe power through multipliers and coefficients. Advancements in technology and system upgrades have increased the accuracy of power readings by making the system more dynamic. The new proposed coefficient and multiplier method implements a cycle specific and physics-based model intended for changing coefficients during operation. This calibration experiment focused on power splitting, outer shim and neck shim, as well as fuel burning into the reactor digital acquisition system (RDAS) weighting factors. Results demonstrated that the physics learning method yields a smaller error margin inside of the desired power range for the data set 166-A. Continuing to improve the physics-based model will help improve the power accuracy of the LPCIS system.
The Advanced Test Reactor (ATR) at INL measures reactor power through two methods, thermal and Nitrogen-16 (N-16) activity. Water power calculator (WPC) is a thermal power system that measures flow and temperature to determine the thermal quadrant powers. The N-16 system utilizes a beta chamber detector that outputs reactivity levels to calculate lobe power through an algorithm called lobe power calculation and indication system (LPCIS). The LPCIS utilizes the N-16 system and the WPC system to determine reactor core power levels. The WPC provides accurate calculations of quadrant and total reactor thermal power. With the use of WPC measurements, thermal-to-N-16 (T2N) power ratios are produced to determine if the two indication systems agree on core power. Relative magnitude equations are used to utilize N-16 coefficients and multipliers to improve the indications of the LPCIS. This is crucial for maintaining safety limits. Currently, the LPCIS system uses linear equations and matrices to calculate lobe power through multipliers and coefficients. Advancements in technology and system upgrades have assisted system engineers at INL with the objective to reach a more dynamic system. In return the system demonstrates an increase in the accuracy of power reading while maintaining safety margins. The new proposed coefficient and multiple method implements a cycle specific, and a physics-based model intended for changing coefficients during operation. This calibration experiment focuses on power splitting, outer shim and neck shim, as well as fuel burning into the RDAS weighting factors. Results show that the Physics learning method yields a smaller error margin inside of the desired power range for the data set 166-A. This proved true for both constrained and unconstrained testing. This is most likely due to the physics data fitting approach that resulted in favorable coefficients and multipliers for 166-A. Continuing to improve the physics-based model will help improve the power accuracy of the LPCIS system.
Cyber-physical system (CPS) security for the smart grid enables secure communication for the SCADA and wide-area measurement system data. Power utilities world-wide use various SCADA protocols, namely DNP3, Modbus, and IEC 61850, for the data exchanges across substation field devices, remote terminal units (RTUs), and control center applications. Adversaries may exploit compromised SCADA protocols for the reconnaissance, data exfiltration, vulnerability assessment, and injection of stealthy cyberattacks to affect power system operation. In this paper, we propose an efficient algorithm to generate robust rule sets. We integrate the rule sets into an intrusion detection system (IDS), which continuously monitors the DNP3 data traffic at a substation network and detects intrusions and anomalies in real-time. To enable CPS-aware wide-area situational awareness, we integrated the methodology into an open-source distributed-IDS (D-IDS) framework. The D-IDS facilitates central monitoring of the detected anomalies from the geographically distributed substations and to the control center. The proposed algorithm provides an optimal solution to detect network intrusions and abnormal behavior. Different types of IDS rules based on packet payload, packet flow, and time threshold are generated. Further, IDS testing and evaluation is performed with a set of rules in different sequences. The detection time is measured for different IDS rules, and the results are plotted. All the experiments are conducted at Power Cyber Lab, Iowa State University, for multiple power grid models. After successful testing and evaluation, knowledge and implementation are transferred to field deployment.
Not Available