Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power generation dispatch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Temperature-Staged Thermal Energy Storage Enabling Low Thermal Exergy Loss Reflux Boiling in Full Spectrum Solar Systems

Hybrid full spectrum solar systems (FSSS) designed to capture and convert the full solar wavelength spectrum use hybrid solar photovoltaic/thermodynamic cycles that require low thermal exergy loss systems capable of transferring high thermal energy rates and fluxes with very low temperature differentials and losses. One approach to achieving this capability are high-heat-flux reflux boiling systems that take advantage of high heat transfer boiling and condensation mechanisms. Advanced solar systems are also intermittent by their nature and their electrical generation is often out-of-phase with electric utility power demand, and their required power system cycling reduces efficiency, performance (dispatch ability), lifetime, and reliability. High temperature thermal energy storage (TES) at 300-600°C enables these reflux boiling systems to simultaneously store thermal energy internally to increase the energy dispatch ability of the associated solar system, as this can increase the power generation profile by several hours (up to 6-10 hours) per day. Many TES phase change materials (PCM’s) exist including KNO3, NaNO3, LiBr/KBr, MgCl2/NaCl/KCl, Zn/Mg, and CuCl/NaCl, which have various operating melting points and different latent heats of fusion. Common, cost effective TES PCM's are FeCl2/NaCl/KCl mixtures, whose phase change temperature can be varied and controlled by simple composition adjustments. This paper presents and discusses unique "temperature-staged" thermal energy storage configurations using these TES materials and analysis of such systems integrated into high-heat-flux reflux boiling systems. In this specific application, the TES materials are designed to operate at staged temperatures surrounding an operating design point near 350°C, while providing 18 kW of source heat transfer to operate a thermoacoustic power system during off-sun conditions (e.g., temporary cloud conditions, after sun-down). This work discusses relevant configurations, and critical thermal and entropy models of the TES configurations, which show the inherent minimization of thermal exergy during critical heat transfers within the configurations and systems envisioned.

Hendricks, Terry J.↗

Black-Box Optimization for Design of Concentrating Solar Power and Photovoltaic Hybrid Systems with Optimal Dispatch Decisions

The hybridization of concentrating solar power (CSP) and photovoltaics (PV) can enable dispatchable renewable electricity generation at a lower price than current stand-alone CSP systems. However, designing a CSP-PV hybrid system can be challenging because of the many degrees of freedom in design that affect the internal and external system interactions and trade-offs. We develop a methodology to determine optimal designs for CSP-PV hybrids by implementing NLopt's derivative-free, or “black-box,” algorithms around pre-existing CSP-PV hybrid simulation software that utilizes the National Renewable Energy Laboratory’s System Advisor Model (SAM); we then employ a dispatch optimization model to determine operational decisions that maximize a plant’s profits. We present optimal designs for CSP-PV hybrid systems dispatching against four time-of-delivery (ToD) pricing structures. NLopt’s algorithms can improve the base case design’s power purchase agreement (PPA) price by 15% to 21%, depending on the ToD pricing structure. In addition, we present the resulting optimal CSP-PV hybrid design’s annual performance metrics, which tend to have capacity factors between 50% and 62%, but are able to generate electricity during the year’s highest-valued periods about 90% of the time. Lastly, we investigate the trade-offs between capacity factor and PPA price using Pareto fronts and demonstrate that, for some ToD pricing structures, the system capacity factor can increase by 20% but at the expense of a 2% increase in PPA price.

black-box↗

Economic Comparison Between Battery and Supercapacitor for Hourly Dispatching Wave Energy Converter Power

This paper demonstrates a dispatching scheme of slider-crank wave energy converter (WEC) power generation using two different kinds of energy storage components, namely, Lithium-ion (Li-ion) battery and Supercapacitors (SC). The performance of the two energy storage components has been compared in order to develop the most economical energy storage system for WEC hourly dispatching scheme. The cost optimization of the energy storage system considering both cycling and calendar aging expenses is made based on its usage of depth of discharge. In this study, extensive simulation is conducted in MATLAB/Simulink platform, and it is found that SC is a better solution than Li-ion battery in terms of economic assessment for hourly dispatching WEC power.

50 EE - Wind and Water Power Program - Water (EE-4↗

Craig Energy Center Feasibility Study

Tri-State Generation and Transmission Association Inc. (“Tri-State”) provides wholesale electric power to its member cooperatives and public power districts that collectively deliver electricity to more than a million consumers in Colorado, Nebraska, New Mexico and Wyoming. The Craig Power Station has been an integral part of Tri-State’s dispatchable generation fleet that ensures an affordable, reliable and resilient energy supply for its members. The ownership of the Craig Station Unit 1&2 is a collaborative between Tri-State, Salt River Project Agricultural Improvement and Power District, Platte River Power Authority, PacifiCorp, and Public Service Company of Colorado and is known as the Yampa Project. Tri-State owns all of Craig Unit 3 and is the operator of all three units. All three of the Craig units have planned retirement dates that will not extend beyond 2028 and Tri-State Generation wanted to evaluate carbon-neutral emitting technologies that could provide approximately 300 megawatts (“MWs) of capacity and energy that will be lost after Unit 3 ceases operation, as well as provide a similar level of economic benefits to the Craig community. This report is to serve as a technology feasibility study constrained to the current land area available at the Craig site and was conducted based on the limitations of the region.

25 ENERGY STORAGE↗

The value of hydropower flexibility for electricity system decarbonization

Hydropower is an abundant, dispatchable, clean energy resource that will play an important role in supporting the clean energy transition. In particular, dispatchable hydropower can provide the operational flexibility that will be required in future systems with high variable renewable energy penetrations. However, the theoretical operational flexibility of hydropower can be restricted in practice by various non-power constraints. In this paper, we quantify how increasing the operational flexibility of dispatchable hydropower resources with reservoirs impacts least-cost generation portfolios and supports power system decarbonization. Specifically, we conduct a capacity expansion analysis of a two-zone system: a hydro-dominated region and a neighboring region with aggressive decarbonization targets that are represented by the United States Pacific Northwest and California respectively. We then introduce a quantifiable index for characterizing the operational flexibility of reservoir hydropower and assess how changes in this metric impact the system-optimal generation portfolio. We find that increasing hydropower flexibility leads to more investment in wind generation, less investment in natural gas generation, lower system costs, and lower system emissions. We further demonstrate a substitution effect between the grid services provided by flexible hydropower operation, increased transmission capacity on a congested line, and energy storage resources. Finally, we show that increasing the operational flexibility of hydropower increases the effective load carrying capability of both hydropower and wind resources. This research supports a more nuanced understanding of how hydropower can support electricity system decarbonization and may motivate reassessing the cost-benefit tradeoffs of non-power constraints that restrict operational flexibility.

Capacity expansion modeling↗

A Rapid Procedure Development Approach for Multi-stage Validation of Novel Nuclear Power Plant Systems

The integration of renewable energy sources into the modern grid introduces variability in generation, challenging nuclear reactors to remain economically viable amid low wholesale electricity prices. To address this, Idaho National Laboratory?s Flexible Plant Operation and Generation program explores alternative revenue streams, including commoditizing excess thermal energy. A Thermal Power Dispatch (TPD) system enables steam extraction from the secondary loop for industrial uses like hydrogen production via high-temperature steam electrolysis.

99 - GENERAL AND MISCELLANEOUS↗

Man‐in‐the‐middle attacks and defence in a power system cyber‐physical testbed

Abstract Man‐in‐The‐Middle (MiTM) attacks present numerous threats to a smart grid. In a MiTM attack, an intruder embeds itself within a conversation between two devices to either eavesdrop or impersonate one of the devices, making it appear to be a normal exchange of information. Thus, the intruder can perform false data injection (FDI) and false command injection (FCI) attacks that can compromise power system operations, such as state estimation, economic dispatch, and automatic generation control (AGC). Very few researchers have focused on MiTM methods that are difficult to detect within a smart grid. To address this, we are designing and implementing multi‐stage MiTM intrusions in an emulation‐based cyber‐physical power system testbed against a large‐scale synthetic grid model to demonstrate how such attacks can cause physical contingencies such as misguided operation and false measurements. MiTM intrusions create FCI, FDI, and replay attacks in this synthetic power grid. This work enables stakeholders to defend against these stealthy attacks, and we present detection mechanisms that are developed using multiple alerts from intrusion detection systems and network monitoring tools. Our contribution will enable other smart grid security researchers and industry to develop further detection mechanisms for inconspicuous MiTM attacks.

Wlazlo, Patrick↗

Water and Climate Impacts on ERCOT Long-Term Systems Assessment

Water and climate change pose many potential challenges to the electric power system. Substantial water is withdrawn every day to support thermoelectric power generating unit operations, and changes to water supply have the potential to affect generation dispatch. Climate change can accelerate growing demand for electricity, which can necessitate additional generating capacity, often in locations with limited water supply. Drought conditions also threaten thermoelectric power plant operations due to streamflow and reservoir levels dropping below intake structures, or water temperatures exceeding a power plants' permitted operating conditions. Here we explore how future climate change might influence decisions related to electricity capacity expansion planning in Electric Reliability Council of Texas (ERCOT) using a multi-model framework. Specifically, water resource modeling is used to simulate climate impacts on the future water supply for thermoelectric and hydropower generation for four future climate projections. Separately, temperature impacts on electricity load are evaluated for these scenarios. These climate impacts are applied to five alternative electricity futures in an electricity capacity expansion model that projects future generation and transmission capacity additions in ERCOT. Results indicate that climate has a measurable influence on future generation and transmission capacity needs, with temperature-driven increases in peak and average load resulting in 5-15 GW additional generating capacity and up to 1 GW additional transmission capacity. Additional capacity is a diverse mix of PV, natural gas, and wind, depending on the makeup of economic, policy and technology assumptions. Climate impacts increase total system costs 2-5%, while the marginal cost of energy and emissions are not affected substantially by climate change effects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electric Power Monitor

Control center for SAMAC (System Automatic Monitor and Control) is a sophisticated dispatch computer system, developed by Rockwell International and operated by Philadelphia Electric Co. SAMAC monitors and controls the generation and distribution of electric power throughout the Philadelphia electric network. With the assistance of NASA's Apollo computer system technology, it enables human operators to isolate and correct power distribution problems more rapidly than was possible with earlier dispatch systems without centralized computer control.

Source record↗

Tightest Mixed-Integer Programming Formulations for Quadratic SCUC Optimization

In this project, we developed new, tighter Mixed-Integer Programming (MIP) formulations for the combined Alternating Current (AC) Security-Constrained Unit Commitment (SCUC) and Security-Constrained Optimal Power Flow (SCOPF). The work addresses a critical challenge in power system operations: efficiently determining which generation units to commit and how to optimally dispatch them while maintaining network reliability constraints for both normal and contingency scenarios. Our efforts: 1. Advance the Understanding of SCUC/SCOPF Modeling: By introducing tighter MIP formulations and leveraging cutting-edge optimization tools (Julia/JuMP, PowerModels.jl), this project has pushed forward the state of the art in efficient power systems scheduling. 2. Enhance Technical and Economic Feasibility: The methods developed provide more accurate and potentially faster solutions to large-scale, realistic scheduling and dispatch problems in electric power systems, which can translate into improved reliability and potentially lower costs for grid operations. 3. Benefit to the Public: Greater efficiency in power system operations leads to cost savings for utilities and end-users. Improved reliability and integration of advanced modeling approaches can facilitate the adoption of clean energy resources and better accommodate uncertainties in renewable generation. Because this technology could impact bulk power markets and reliability, these innovations have far-reaching public benefits in terms of cost savings, reliability, and sustainability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scaling Up CSP: How Long Will it Take?

Concentrating solar power (CSP) is one of the few scalable technologies capable of delivering dispatchable renewable power. Therefore, many expect it to shoulder a significant share of system balancing in a renewable electricity future powered by cheap, intermittent PV and wind power: the IEA, for example, projects 73 GW CSP by 2030 and several hundred GW by 2050 in its Net-Zero by 2050 pathway. In this paper, we assess how fast CSP can be expected to scale up and how long time it would take to get new, high-efficiency CSP technologies to market, based on observed trends and historical patterns. We find that to meaningfully contribute to net-zero pathways the CSP sector needs to reach and exceed the maximum historical annual growth rate of 30%/year last seen between 2010-2014 and maintain it for at least two decades. Any CSP deployment in the 2020s will rely mostly on mature existing technologies, namely parabolic trough and molten-salt towers, but likely with adapted business models such as hybrid CSP-PV stations, combining the advantages of higher-cost dispatchable and low-cost intermittent power. New third-generation CSP designs are unlikely to play a role in markets during the 2020s, as they are still at or before the pilot stage and, judging from past pilot-to-market cycles for CSP, they will likely not be ready for market deployment before 2030. CSP can contribute to low-cost zero-emission energy systems by 2050, but to make that happen, at the scale foreseen in current energy models, ambitious technology-specific policy support is necessary, as soon as possible and in several countries.

concentrated solar power↗

Optimal Complementarity Analysis of Potential Floating Solar Co-Located With Existing Hydropower Assets Across the Contiguous United States

The U.S. is expected to double its rate of renewable capacity from 2024 to 2030. However, the stochastic nature of renewable energy poses challenges to the operation and reliability of our power grid. The combined generation from renewable energy sources, with dispatchable sources (such as hydropower) operating as a hybrid energy plant, could mitigate this variability. In this paper, the complementarity analysis of selected U.S. reservoirs with existing hydropower assets (EHAs) and potential floating photovoltaics (FPVs) is conducted for the continuous U.S. (CONUS). The optimal FPV capacity for each site is determined by minimizing the variability of the combined output, while adhering to the FPV potential. Our results indicate that over 50% of the analyzed reservoirs achieve a stability coefficient exceeding 0.5, leading to a less-variable output after optimization. Finally, we analyze the complementary hydro-FPV hybrid reservoirs by considering both the Pearson correlation coefficient and the stability coefficient on daily, monthly, and yearly scales. Summaries are included of locations of theoretical FPVs co-located with hydropower plants that exhibit high complementarity based on the selected metrics.

13 - HYDRO ENERGY↗

Life Cycle Assessment for Closed-Loop Pumped Hydropower Energy Storage in the United States

The federal government has initiated an aggressive set of policies to achieve a net-zero carbon emission goal for the electricity sector by 2050. As a result, rapid growth in deployment of renewable energy technologies is expected. Most commercially mature technologies are temporally variable and do not provide grid inertia, while renewable technologies with high projected deployment have intermittent generation methods. Energy storage technologies are needed to both dispatch power on-demand and help provide the needed grid inertia. Pumped storage hydro (PSH) is a well-established technology that has gained renewed interest in recent years offering energy-balancing, grid stability, control of electrical network frequency, and large-scale storage capacity. For widespread adoption of PSH, more information is needed regarding its current life cycle environmental impacts. The objective of this study is to perform a full life cycle assessment (LCA) of new closed-loop PSH in the U.S. The functional unit for this study is 1 kWh of electrical power delivered to the grid and the base case project lifetime is 80 years. The life cycle inventory for this project accounts for all material and energy flows associated with the green-field construction, operation, maintenance, and decommissioning of a closed-loop PSH plant in the U.S. Collected data represents a range of potential PSH specifications and geographic locations coming from all prospective closed-loop PSH installations in the U.S. with data available. In addition, existing PSH installations are used to provide assumptions for inventory inputs. Results presented will include the global warming potential (GWP IPCC 100a) and Energy Return on Investment (EROI) from our base case (average PSH installation) as well as from scenario analyses and model sensitivity. These results will be compared to the impacts from existing PSH sites and alternate storage technologies. Methods align with the assumptions and guidelines put in place by previous PSH LCAs to ensure an accurate comparison with the results from this report.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

Operation-adversarial scenario generation

This paper proposes a modified conditional generative adversarial network (cGAN) model to generate net load scenarios for power systems that are statistically credible, conditioned by given labels (e.g., seasons), and, at the same time, “stressful” to the system operations and dispatch decisions. The measure of stress used in this paper is based on the operating cost increases due to net load changes. The proposed operation-adversarial cGAN (OA-cGAN) internalizes a DC optimal power flow model and seeks to maximize the operating cost and achieve a worst-case data generation. The training and testing stages employed in the proposed OA-cGAN use historical day-ahead net load forecast errors and has been implemented for the realistic NYISO 11-zone system. In conclusion, our numerical experiments demonstrate that the generated operation-adversarial forecast errors lead to more cost-effective and reliable dispatch decisions.

42 ENGINEERING↗

Feasible Actuator Range Modifier (FARM), a Tool Aiding the Solution of Unit Dispatch Problems for Advanced Energy Systems

Integrated energy systems (IESs) seek to minimize power generating costs in future power grids through the coupling of different energy technologies. To accommodate fluctuations in load demand due to the penetration of renewable energy sources, flexible operation capabilities must be fully exploited, and even power plants that are traditionally considered as base-load units need to be operated according to unconventional paradigms. Thermomechanical loads induced by frequent power adjustments can accelerate the wear and tear. If a unit is flexibly operated without respecting limits on materials, the risk of failures of expensive components will eventually increase, nullifying the additional profits ensured by flexible operation. In addition to the bounds on power variations (explicit constraints),the solution of the unit dispatch problem needs to meet the limits on the variation of key process variables, including temperature, pressure and flow rate (implicit constraints).The FARM (Feasible Actuator Range Modifier) module was developed to enable existing optimization algorithms to identify solutions to the unit dispatch problem that are both economically favorable and technologically sustainable. Thanks to the iterative dispatcher–validator scheme, FARM permits addressing all the imposed constraints without excessively increasing the computational costs. In this work, the algorithms constituting the module are described, and the performance was assessed by solving the unit dispatch problem for an IES composed of three units, i.e., balance of plant, gas turbine, and high-temperature steam electrolysis. Finally, the FARM module provides dedicated tools for visualizing the response of the constrained variables of interest during operational transients and a tool aiding the operator at making decisions. These techniques might represent the first step towards the deployment of an ecological interface design (EID) for IES units.

47 OTHER INSTRUMENTATION↗

Hydrogen Storage for Load-Following and Clean Power: Duct-firing of Hydrogen to Improve the Capacity Factor of NGCC Plants (Final Report, Phase II Pre-Front End Engineering Design Study)

GTI Energy (GTI) and team members Southern Company Services (SCS), Pacific Gas & Electric (PG&E) and the Electric Power Research Institute (EPRI) performed a Phase II Pre-Feed Study under contract DE-FE0032008 for Hydrogen Storage for Load-Following and Clean Power. The configuration of the proposed system consists of subsystems for on-site H 2 production, on-site H 2 storage (up to 54 MWth in commercial vessels) and H 2 combustion in a duct burner in a Heat Recovery Steam Generator (HRSG) integrated with an existing fossil asset. Here, the firing rate of the duct burner is varied to let the plant respond to fluctuations of electrical load and H 2 production is relatively constant by storing H 2 . The proposed system is an improvement over alternate low carbon dispatchable power options. Technoeconomic analyses show H 2 produced with GTI’s patented Compact Hydrogen Generator (CHG) with inherent carbon capture will be lower cost (Levelized Cost of Hydrogen, LCOH) relative to hydrogen produced with a Steam Methane Reformer (SMR) with an amine system for carbon capture. This lower cost hydrogen enables our integrated system to deliver electricity (Levelized Cost of Electricity, LCOE) at 17.4% lower cost relative to a SMR sourced H 2 -fired HRSG (with an amine system for carbon capture) – Steam Turbine Generator (STG). Our analysis using EPRI’s US REGEN macroeconomic model shows our system will have significant demand in the power market and therefore require significant capacity expansion (CHG plants built to deliver hydrogen) to deliver low cost, low carbon power. In Phase II, our Team has completed a detailed system definition including the development of process models, definition of battery limits, Process Flow Diagrams (PFDs), Piping and Instrumentation Drawings (P&IDs), and a plant layout. A preliminary design for the key components of the CHG was developed including component lists & specifications. An evaluation of environmental and permitting considerations was completed and included the development of an Environmental Information Volume (EIV). The duct burners, which are flexible and can burn hydrogen and/or natural gas, were defined and initial CFD analyses were completed.

03 NATURAL GAS↗

US 2023/0182605 A1 Network constraint energy management system for electric vehicle depot charging and scheduling

Network constraint energy management system for electric vehicle (EV) depot charging and scheduling. In an embodiment, a power schedule is received from an economic dispatch application for a charging depot comprising EV charging station(s) and distributed energy resource(s). The power schedule may be simulated on a distribution network model of the charging depot, according to load flow analysis, to determine whether any grid-code violations occur. In response to the detection of violation(s), a constraint may be generated for each violating node, and the economic dispatch application may be re-executed with the constraint(s) to produce a new power schedule, until no violations are detected. When not all load demand can be satisfied by the power schedule, a charging schedule may be adjusted to ensure that critical energy requirements are satisfied. The final power and charging schedules may be used to schedule and control power generation and charging in the charging depot.

Hafiz, Faeza↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation: Preprint

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., lost a large generation unit). The NLM engine is a central dispatch control system that provides high-speed cost-optimal coordination of a set of net loads (combination of generation and deferrable loads) connected to the same electrical network. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm. The experimental results indicate that the NLM engine can achieve the targeted system voltage and frequency and balance load and generation to serve the critical facility.

droop control↗