Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “positive ions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Electron emissions and hot spots in dual-phase LXe TPCs

Persistent photon and single-electron emissions - in the form of “electron trains” and localized “hot spots” - have been observed in multiple dual-phase liquid xenon (LXe) time projection chambers (TPCs), often persisting long after ionizing events. Here, we show that these phenomena are naturally explained by photon-triggered single-electron emission from resistive mixed-oxide films on stainless-steel (SS304 or s.s.) wires, which behave as leaky capacitors with long RC time constants at LXe temperature. Positive ions landing on these oxides can further enhance local fields and drive Malter-like electron emission. We outline the materials physics (Cr 2 O 3 /Cr 2 O 3-x /Cr(OH) 3 mosaics), quantify expected time scales (∼1 s under illumination), and demonstrate how small damaged regions with enhanced QE can produce persistent hot spots.

Va'vra, J. [SLAC National Accelerator Laboratory (↗

Experimental and Computational Evaluation of Lipidomic In-Source Fragmentation as a Result of Postionization with Matrix-Assisted Laser Desorption/Ionization

Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) can provide spatially resolved molecular information about a sample. Recently, a postionization approach (MALDI-2) has been commercially integrated with MALDI-MSI, allowing for bettered sensitivity and consequent improved spatial resolution. While advantages of MALDI-2 have previously been established, we demonstrate here statistically increased in-source fragmentation (ISF) results from postionization with a commercial instrument. Via lipid standard analyses, known MALDI ISF pathways (e.g., loss of trimethylamine) were statistically increased in MALDI-2 compared to MALDI-1 (65–172% increase in fragmentation). Gas phase molecular modeling with density functional theory estimated that the most-weighted virtual orbitals to excite within lipids involve ester and phosphate bonds. Protonated lipid excitation energies are furthermore red-shifted compared to those of other adduct types [e.g., 254 nm for protonated PC(16:0/18:1)] and approach the MALDI-2 laser energy (266 nm). Analysis of rat brain homogenate detected statistically more positive-ion mode peaks with MALDI-2 (1090) than that with MALDI-1 (719), where Kernel density estimations showed that the majority of this enhancement occurs with low m/z ions (i.e., m/z 75–500). Taken together with the lipid standard data, these observations may indicate ISF due to postionization. Finally, while artifact contributions from matrix blanks were also noted, both experimental and computational data sets suggest that the overall extent of ISF is statistically increased in MALDI-2 compared to MALDI-1.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Light–ferroelectric interaction in two-dimensional lead iodide perovskites

The unique physical properties of two-dimensional (2D) metal halide perovskites (MHPs) such as nonlinear optics, anisotropic charge transport, and ferroelectricity have made these materials promising candidates for multifunctional applications. Recently, fluorine derivatives such as 4,4-difluoropiperidinium lead iodide perovskite or (4,4-DFPD, C 5 H 10 F 2 N) 2 PbI 4 have shown strong ferroelectricity as compared to other 2D MHPs. Although it was previously addressed that the ferroelectricity in MHPs can be affected by illumination, the underlying physical mechanisms of light–ferroelectricity interaction in 2D MHPs are still lacking. Here, we explore the electromechanical responses in 4,4-(DFPD) 2 PbI 4 thin films using advanced scanning probe microscopy techniques revealing ferroelectric domain structures. In this work, hysteretic ferroelectric loops measured by contact-Kelvin probe force microscopy are dependent on domain structures under dark conditions, while ferroelectricity weakens under illumination. The X-ray diffraction patterns exhibit significant changes in preferential orientation of individual lattice planes under illumination. Particularly, the reduced intensity of the (1 1 1) lattice plane under illumination leads to transitioning from a ferroelectric to a paraelectric phase. The instability of positive ions, especially molecular organic cations, is observed under illumination by time-of-flight secondary ion mass spectrometry. The combination of crystallographic orientation and chemical changes under illumination clearly contributes to the origin of light–ferroelectricity interaction in 2D (4,4-DFPD, C 5 H 10 F 2 N) 2 PbI 4 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plasma parameters and the reduction potential at a plasma-liquid interface

We report nonthermal plasmas in contact with liquids have been shown to generate a variety of reactive species capable of initiating reduction–oxidation (redox) reactions at the electrochemically active plasma–liquid interface. In conventional electrochemical cells, selective redox chemistry is achieved by controlling the reduction potential at the solid electrode–electrolyte interface by applying a bias via an external circuit. In the case of plasma–liquid systems, an analogous means of tuning the reduction potential near the interface has not clearly been identified. When treated as a floating surface, the liquid is expected to adopt a net negative charge to balance the flux of hot electrons and relatively cold positive ions. The reduction potential near the plasma–liquid interface is hypothesized to be proportional to the floating potential, which can be approximated using an analytical model provided the plasma parameters are known. Herein, we present a framework for correlating the electron density and electron temperature of a noble gas plasma jet to the reduction potential near the plasma–liquid interface. The plasma parameters were acquired for an argon atmospheric plasma jet in contact with an aqueous solution by means of laser Thomson scattering. The reduction potential was determined using identical reference electrodes to measure the potential difference between the plasma–liquid interface and bulk solution. Interestingly, the measured reduction potentials near the plasma–liquid interface were found to be in good agreement with the model-predicted values determined using the plasma parameters obtained from the Thomson scattering experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electric field measurements of DC-driven positive streamer coronas using the E-FISH method

This paper reports on electric field measurements, using the electric field-induced second harmonic (E-FISH) method, sampling the spatial structure and temporal development of DC-driven positive streamer coronas in atmospheric-pressure air at relevant timescales to examine the self-pulsating behavior of the discharge. The discharge is triggered from a point-to-plate geometry and consists of transient coronas, which bridge the inter-electrode gap and pulsate at about 3 kHz, superimposed with a persisting glow corona. The measurements presented challenge the phenomenological explanation for the pulsations based on field recovery at the anode driven by the evacuation of positive ions by electric drift effects and hint at a propagating wave-like feature from the plate-cathode to the tip-anode.

42 ENGINEERING↗

Ion trap with in-vacuum high numerical aperture imaging for a dual-species modular quantum computer

Photonic interconnects between quantum systems will play a central role in both scalable quantum computing and quantum networking. Entanglement of remote qubits via photons has been demonstrated in many platforms; however, improving the rate of entanglement generation will be instrumental for integrating photonic links into modular quantum computers. We present an ion trap system that has the highest reported free-space photon collection efficiency for quantum networking. We use a pair of in-vacuum aspheric lenses, each with a numerical aperture of 0.8, to couple 10(1)% of the 493 nm photons emitted from a 138Ba+ ion into single-mode fibers. We also demonstrate that proximal effects of the lenses on the ion position and motion can be mitigated.

Instruments & Instrumentation↗

Study of space charge in the ICARUS T600 detector

The accumulation of positive ions, produced by ionizing particles crossing Liquid Argon Time Projection Chambers (LAr-TPCs), may generate distortions of the electric drift field affecting the track reconstruction of the ionizing events. These effects could become relevant for large LAr-TPCs operating at surface or at shallow depth, where the detectors are exposed to a copious flux of cosmic rays. We report a detailed study of such possible field distortions in the ICARUS T600 LAr-TPC has been performed analyzing a sample of cosmic muon tracks recorded with one T600 module operated at surface in 2001. The maximum track distortion turns out to be of few mm in good agreement with the prediction by a numerical calculation. As a cross-check, the same analysis has been performed on a cosmic muon sample recorded during the ICARUS T600 run at the LNGS underground laboratory, where the cosmic ray flux was suppressed by a factor $\sim 10^6$ by 3400 m water equivalent shielding. No appreciable distortion has been observed, confirming that the effects measured on surface are actually due to ion space charge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the longitudinal diffusion of ionization electrons in the MicroBooNE detector

Accurate knowledge of electron transport properties is vital to understanding the information provided by liquid argon time projection chambers (LArTPCs). Ionization electron drift-lifetime, local electric field distortions caused by positive ion accumulation, and electron diffusion can all significantly impact the measured signal waveforms. This paper presents a measurement of the effective longitudinal electron diffusion coefficient, D L , in MicroBooNE at the nominal electric field strength of 273.9 V/cm. Historically, this measurement has been made in LArTPC prototype detectors. This represents the first measurement in a large-scale (85 tonne active volume) LArTPC operating in a neutrino beam. This is the largest dataset ever used for this measurement. Using a sample of ~70,000 through-going cosmic ray muon tracks tagged with MicroBooNE's cosmic ray tagger system, we measure D L = 3.74 +0.28 -0.29 cm 2 /s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact dication source for Ba 2+ tagging and heavy metal ion sensor development

Here, we present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cadmium samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba 2+ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb 2+ and Cd 2+ also demonstrated for this purpose.

47 OTHER INSTRUMENTATION↗

Broadening of the drumhead-mode spectrum due to in-plane thermal fluctuations of two-dimensional trapped ion crystals in a Penning trap

Two-dimensional crystals of ions stored in Penning traps are a leading platform for quantum simulation and sensing experiments. For small amplitudes, the out-of-plane motion of such crystals can be described by a discrete set of normal modes called the drumhead modes, which can be used to implement a range of quantum information protocols. However, experimental observations of crystals with Doppler-cooled and even nearground- state-cooled drumhead modes reveal an unresolved drumhead-mode spectrum. In this work, we establish in-plane thermal fluctuations in ion positions as a major contributor to the broadening of the drumhead-mode spectrum. In the process, we demonstrate how the confining magnetic field leads to unconventional in-plane normal modes, whose average potential and kinetic energies are not equal. This property, in turn, has implications for the sampling procedure required to choose the in-plane initial conditions for molecular-dynamics simulations. Further, for current operating conditions of the NIST Penning trap, our study suggests that the two-dimensional crystals produced in this trap undergo in-plane potential-energy fluctuations of the order of 10mK. Our study therefore motivates the need for designing improved techniques to cool the in-plane degrees of freedom.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-resolved measurement of electron beam neutralization

An intense relativistic electron beam (IREB) incident on a target generates positive ions by stimulated and thermal desorption of adsorbed gas, and subsequent electron impact ionization. These ions are accelerated upstream by the beam space-charge potential, thereby partially neutralizing the beam. If there is enough neutralization, the repulsive space-charge force can be overcome by the magnetic-pinch force due to the beam current. This so-called ion focusing is responsible for time dependent defocusing of the radiographic source spot. Since a single monolayer of adsorbed gas has a surface density of about 10 15 /cm 2 and is formed in about one second in a one micro-Torr vacuum, there is always enough adsorbed gas to make this a concern in our accelerators. Therefore, time-resolved measurements of the degree of neutralization are valuable for better understanding of this process with an eye to mitigation for improvement of our radiography. Moreover, these measurements would aid quantification of uncertainties due to these effects when using invasive beam diagnostics, such as OTR imaging targets.

43 PARTICLE ACCELERATORS↗

Collaborative Research: Advancing the Physics of Magnetized Dusty Plasmas (Final Scientific /Technical Report)

A plasma is a gas of charged particles – electrons and positive ions in roughly equal concentrations. Plasmas are formed by stripping electrons from neutral atoms and molecules. It is believed that the plasma state of matter comprises over 99% of the universe. Often the plasma coexists with small (1/1000 of a millimeter) dust particles. Some of the plasma particles collect on the dust grains which cause it to be electrically charged, and so become an integral part of the plasma, forming what is called a “dusty plasma”. The large objects in the universe (planets, asteroids, comets, stars) are formed by combining dust grains into larger and larger objects, eventually held together by their self-gravitational attraction. Thus, an understanding of the processes that control the structure and evolution of the universe, requires that we understand the behavior of dusty plasmas. These plasmas also often are embedded in magnetic fields which has a strong influence on their structure and behavior. Thus, developing an understanding of dusty plasmas in magnetic fields, so-called magnetized dusty plasmas, is also essential. In addition to the dusty plasmas occurring in nature, dusty plasmas play an important role in many plasma-based technologies, such as the production of semiconductor devices, and in the next generation of clean-and-green-energy producing devices based on nuclear fusion. The purpose of the work performed with funding provided in this grant by the United States Department of Energy was to produce and investigate the physics of magnetized dusty plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration of the ProtoDUNE Horizontal-Drift position reconstruction using a laser system

Forthcoming in the next decade of neutrino physics advancements is the construction of the Deep Underground Neutrino Experiment (DUNE), a long baseline neutrino oscillation experiment which has the potential to answer fundamental questions such as why there is more matter than antimatter in the universe, and ultimately why we exist at all. A prototype of this experiment, ProtoDUNE, sits in a charged particle test beam at the European Organization for Nuclear Research (CERN) and uses Liquid Argon time projection chambers to image interactions of these particles. ProtoDUNE Single-Phase (ProtoDUNESP) had positively charged hadrons as well as positrons in its initial 2018 beam data run. Because ProtoDUNE is a surface-based time projection chamber, it experiences a constant influx of cosmic rays. These cosmic rays ionize the liquid argon within the detector, resulting in an accumulation of slow moving positive ions towards the cathode. This local charge distribution results in electric field non uniformities, which can have a significant effect on the accuracy of the event reconstruction. This paper outlines a monte carlo simulation study which adapts methodology from the MicroBooNE experiment, another neutrino oscillation experiment, to derive electric field correction maps which can correct for distortions of the electric field within the detector. These correction maps accurately estimate the electric field throughout the detector volume and correct for uncertainties in reconstructed event data enabling for physics discoveries.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of space charge effects and energy calibration in ProtoDUNE-SP

The single-phase liquid argon prototype at CERN (ProtoDUNE-SP) acts as a validation of the design for the DUNE single-phase far detector. With a total mass of 770 tons, it is the largest monolithic liquid argon single-phase time projection chamber in the world. ProtoDUNE-SP collected test-beam in autumn of 2018 and has been collecting cosmic and special calibration data since the end of 2018.The accumulation of positive ions in a LArTPC located on the surface can distort the electric field and the reconstructed particle trajectories. It is critical to understand and correct for the space charge effects in order to achieve the desired spatial and calorimetric resolutions in the LArTPC. This talk will present the measurement of space charge effects and the calorimetric measurements of the detector in ProtoDUNE-SP.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pitch-Angle Diffusion in the Earth’s Magnetosphere Organized by the Mozer-Transformed Coordinate System

In the Earth’s dipole magnetosphere finite-gyroradius effects produce a shift of the atmospheric loss cone away from the direction of the magnetic field. This loss-cone shift is theoretically described by the “Mozer transform”, which is based upon the curvature drift of particles crossing the equatorial plane. For positive ions the northern and southern loss cones both shift westward and for electrons the northern and southern loss cones both shift eastward. This loss-cone shift is part of a coordinate-system transform, with the transformed coordinates better organizing the behavior of particle orbits in the dipole magnetic field (e.g. first adiabatic invariants, mirror heights, and bounce times). In this report it is demonstrated that the transformed coordinate system also properly organizes pitch-angle diffusion. This improved organization of the diffusion is true whether the angular scattering is produced by plasma-wave scattering or by field-line-curvature (FLC) scattering. It is shown that FLC scattering and the loss cone shift are linked, so that if FLC scattering is occurring, there is a loss cone shifted away from the magnetic-field direction and the Mozer-transformed coordinates are needed.

79 ASTRONOMY AND ASTROPHYSICS↗

Thallium Bromide Semiconductor Radiation Materials and Detectors Characterization Studies

Two overarching requirements of crucial importance for the commercial and scientific establishment of semiconductor radiation detectors are: (1) exceptionally high-purity crystals with impurity concentrations less than 1 part-per-billion and (2) single crystals that are relatively free from subgrain boundaries, secondary phases, dislocations, and other electrically-active defects. We investigated the properties of thallium bromide (TlBr) material that affect its performance with the goal of increasing the material's commercial viability for radiation detection applications. For this purpose, we used beamlines at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory (BNL), performing Micron-scale X-ray Detector Mapping, White Beam X-ray Diffraction Topography, and Micron-scale X-ray Fluorescence. These characterization methods improve the industry's understanding of TlBr and lead to the production of improved instrumentation. In this particular study we report electro-migration measurements of positive-ion Cu, Ag, and Au impurities in TlBr detectors under electric field strengths typically used for device operation. BNL improved TlBr detectors with an electrode design that corrects the response non-uniformities caused by crystal defects. This design can achieve improved energy resolution while using typical-grade, commercial crystals with relaxed quality requirements, thus reducing the overall cost of detectors. Additional characterization will be necessary to fully understand the structure and performance of TlBr with the ultimate goal to achieve the highest energy resolution. Our findings from past work will be presented along with our recommendations for additional investigation.

36 MATERIALS SCIENCE↗

Metal-air cell with performance enhancing additive

Systems and methods drawn to an electrochemical cell comprising a low temperature ionic liquid comprising positive ions and negative ions and a performance enhancing additive added to the low temperature ionic liquid. The additive dissolves in the ionic liquid to form cations, which are coordinated with one or more negative ions forming ion complexes. The electrochemical cell also includes an air electrode configured to absorb and reduce oxygen. The ion complexes improve oxygen reduction thermodynamics and/or kinetics relative to the ionic liquid without the additive.

Friesen, Cody A.↗

Quantitative Measurement of Positive and Negative Ion Species Ejected from a Li–O–H Surface by Hydrogen and Noble Gas Ion Irradiation

We report sputtering yields of Li + , H - , O - , and OH x - ion species from an Li–O–H surface for H, D, He, Ne, and Ar ion irradiation at 45° incidence in the energy range of 30–2000 eV. A Li film was deposited on a stainless steel target using Li evaporators in the LTX-β vessel, using the LTX-β Sample Exposure Probe (SEP), which includes an ultrahigh vacuum suitcase for transferring targets without significant contamination from air exposure. The SEP was used to transfer the Li-coated target from LTX-β to a separate Sample Exposure Station (SES) to perform ion exposure measurements. The SEP was also used for characterization of the Li-coated target utilizing X-ray photoelectron spectroscopy in a different chamber, showing that the lithium film surface was oxidized. Ion exposures were performed using an electron cyclotron resonance plasma source in the SES. Sputtered/ejected species were sampled by a quadrupole mass spectrometer with capabilities for detecting positive and negative ions, and an energy filter for determining the mean kinetic energy of the ejected ion species. All ion irradiations caused Li + ions to be ejected, while causing impurity ions such as H + , H - , O - and OH - to be ejected. Measured ion energies of Li + ions from a Li–O–H surface suggested that the typical sheath potential on the divertor surface can trap sputtered Li + ions, which were previously reported as ~ 60% of total sputtered Li species from Li targets (Allain and Ruzic in Nucl Fusion 42:202, 2002). Hence, our results for the sputtering yields of ejected ion species and their associated ion energies from a Li–O–H surface indicates that lithium sputtering is suppressed and impurity removal is enhanced due to the sheath potential at the divertor surface for fusion reactor applications.

Plasma-material interaction↗