Prompt Gamma Analysis of ARIES Materials and Updates to the 2015 Calibration Equations
Prompt gamma (PG) analysis is a nondestructive, nuclear, elemental analysis technique that uses charged particle reactions to interrogate a sample, and elements present in the sample matrix are identified through the characteristic gamma-rays emitted from the product nuclei in alpha-p and alpha-n nuclear reactions. This technique has been applied to plutonium oxide packaged in over 4,000 individual 3013 containers, and the concentrations of certain light elements were determined from the integrated peak areas based on a calibration that was published previously. This report provides the results for a new population of 3013 containers packaged with oxide materials produced by the conversion of metal by Advanced Recovery and Integrated Extraction System (ARIES) project using the direct metal oxidation (DMO) process and muffle furnaces. New PG and analytical chemistry data collected since 2015 were added to the existing calibration data sets to refine the calibration parameters. Calibration equations were also developed for determining beryllium and fluorine at low concentrations in high-purity ARIES product oxides. The new fluorine calibration provides an order of magnitude greater sensitivity and results in an additional 1,408 containers in the original population identified as having fluorine as an impurity. Additionally, equations for calculating the lower limits of detection (LLDs) as a function of the actual counting time (live time) were obtained using WLS regression technique for samples in the calibration data set. This resulted in changes to the LLDs published previously.