Carbonated Brine Injection for a Pilot Site as a Low-Risk Geologic Carbon Storage Strategy: A Simulation Study

This technical report presents a preliminary study for CBI implementation in the Pena Creek pilot site in Dimmit County, Texas, targeting the Edwards Limestone Formation for SWD, in collaboration with NGL Energy Partners. The objective of this study is to find the conservative CO 2 molality for safe storage and potential risks for CBI at this pilot site. Geomodel was performed to get site-specific reservoir geology information. Reservoir modeling was performed to investigate dissolved CO 2 molality and pressure changes at relevant injection conditions. Wellbore corrosion and compatibility was discussed with corrosion modeling. Dissolved CO 2 long-term fate in the reservoir was examined with reactive transport modeling. This plan would set the scientific foundation as the initial step for future implementation in the field.

58 GEOSCIENCES↗

New Virtual Test Bed Capabilities: Virtual DOME Model and New Updates to Repository

The Department of Energy (DOE) Office of Nuclear Energy National Reactor Innovation Center accelerates the deployment of novel reactor concepts by establishing both physical and virtual spaces for building and testing various components, systems, and complete pilot plants. The Virtual Test Bed represents the virtual arm of the National Reactor Innovation Center and is a joint effort with the DOE Nuclear Energy Advanced Modeling and Simulation Program. The Virtual Test Bed mission is to accelerate the deployment of advanced reactors by facilitating the adoption of cutting-edge DOE advanced modeling and simulation tools to design, evaluate, and license reactors. This is primarily achieved by storing example challenge problems in an externally available repository and by developing models to fill the M&S gaps needed for potential demonstrators. Activities conducted this fiscal year focused on developing of a Demonstration of Microreactor Experiments shield model to help accelerate the confirmatory analysis required for the reactor demonstration. This model and workflow will allow developers to leverage advanced modeling and simulation tools to ensure their reactor demonstration concept will meet dose requirements and that the surrounding shield will stay within concrete temperature limits during steady-state and transient operation conditions. An initial model has been developed to evaluate the temperature distribution in the concrete shield during steady-state operation, including neutron and gamma heating effects. Various modeling strategies have been examined to understand their applicability and limitations with different reactor designs to make the workflow as reactor-agnostic as possible and computationally effective to maximize its usability. In addition to describing the Demonstration of Microreactor Experiments shield model and associated results, this report summarizes other accomplishments regarding repository maintenance and improvement and new external models hosted on the repository.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Status of New Models Hosted on the Virtual Test Bed (VTB) in 2024

The National Reactor Innovation Center (NRIC) mission is to support deployment of novel reactor concepts. This is achieved by providing physical and virtual spaces for building and testing various components, systems, and complete pilot plants. The Virtual Test Bed (VTB) represents the virtual counterpart to the physical test bed. It is in development in collaboration with the Department of Energy’s (DOE) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. The mission of the VTB is to accelerate the deployment and licensing of advanced reactors by leveraging state-of-the-art modeling and simulation (M&S) tools developed by the DOE NEAMS program. This is accomplished by three primary means: (1) openly hosting simulations that showcase analysis capabilities, (2) continuously testing the models hosted against code updates to avoid deprecation, and (3) filling key M&S gaps that are relevant for the physical NRIC test beds. The VTB repository consists of two sub-entities: 1. A documentation website detailing the models (https://mooseframework.inl.gov/virtual_test_bed). 2. A GitHub repository that hosts the corresponding files (https://github.com/idaholab/virtual_test_bed). Previous documentation on the models hosted in the VTB can be found in [1,2,3,4]. These references also include additional background information on the various NEAMS codes showcased in the VTB (which is omitted here for brevity). This paper primarily provides a status update of the most recent additions to the repository.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

FY25 Theory and Simulation Performance Target: Development of an integrated modeling framework for fusion reactor design and assessment (Final Report)

This report documents the FY25 Theory and Simulation Performance Target (TSPT) of developing an integrated modeling framework for fusion reactor design and assessment (FREDA). Over Q1-Q4, new capabilities were developed across both plasma and engineering domains and demonstrated on an example representation of a Compact Advanced Tokamak with a Dual Cooled Lead Lithium blanket. This represents a first-of-a-kind demonstration of coupled core-to-wall-to-engineering for a reactor. Self-consistent CESOL workflows were applied to provide core, pedestal, and SOL prediction; new modules were developed for energetic particle stability (FAR3D) and transport (TGLF-EP) analysis; and boundary plasma modeling (SOLPS-ITER, BOUT++/Hermes-3) was expanded to evaluate wall and divertor heat fluxes and interface with engineering thermal analysis. A parameterized CAD tool, TRACER, was expanded to generate medium-fidelity divertor, blanket, and coil geometries; OpenFOAM and Diablo workflows were applied for first-wall and divertor thermal analyses with helium cooling; and reduced-order models were created for high-mass-flux divertor cooling. Magnet multiphysics capabilities were verified between Elmer, Diablo, and a new MFEM-based solver, and workflows enable stress, thermal, and neutron-fluence analysis of TF coils with neutronics-driven heating. Nuclear and blanket analysis workflows were demonstrated, including tritium breeding, transport, and CFD-informed thermo-mechanical assessment. Preliminary multi-fidelity uncertainty quantification workflows were applied to boundary modeling codes and shown to achieve variance reductions with fewer high-fidelity boundary simulations. Key findings highlight the challenges of resolving the ITEP gap to find suitable balance between wall and divertor loads, neutron heating, and practical limits of PFC cooling. Next step priorities are to develop automated workflows to check boundary code convergence and detachment, implement tighter physics-engineering CAD provenance tracking, and inclusion of plasma-material interface models for SLAG and tungsten cracking behavior. Collectively, these developments establish sophisticated capabilities for predictive, multi-fidelity, whole-device modeling that integrates plasma physics, materials, magnets, and nuclear engineering to guide pathways to viable Fusion Pilot Plant design points.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessing the limitations of commercial sensors and models for supporting marine carbon dioxide removal monitoring: a case study

Several unknowns remain surrounding marine Carbon Dioxide Removal (mCDR) monitoring, reporting, and verification (MRV) practices and capabilities. Current in-situ sensor technology is limited (primarily pH and pCO 2 ), requiring calculations and assumptions to estimate changes in carbonate chemistry parameters, including total alkalinity (TA). Considering that cost, energy consumption, and accuracy of commercial sensors can vary by orders of magnitude, understanding how well existing sensors perform in an mCDR context is important for this emerging community. Likewise, documenting sensor limitations and how relatively simple models can optimize sensor deployments will improve MRV efforts and support protocol development. Here we (1) compare performance a variety of commercially available sensors in a blind mesocosm experiment simulating ocean alkalinity enhancement (OAE), and how sensor performance impacted carbonate chemistry estimates; (2) evaluate if sensors can distinguish the OAE signal from natural variability during a small scale OAE field test in Sequim Bay, WA, USA, and (3) use an idealized ocean biogeochemistry model to explore optimal sensor network design based on (1) and (2). Our mesocosm results indicate that correctly constraining pH uncertainty will be critical for accurate TA estimates with current sensor technology compared to the less impactful variation caused by uncertainty in pCO 2 (pH data that are presented throughout are reported on the total scale (pH T ) unless otherwise noted). Our pilot field test demonstrated that sensors were capable of distinguishing mCDR signatures from natural variability under optimal real-world conditions. Idealized modeling simulations of the field test showed that a range of sparse and dense (3 to 100) sensors sampling areas of detectable increases will underestimate the net change in surface pH by at least 35–55%, at both realistic and highly elevated alkalinity input levels. We also highlight the limitations of current sensing technology for MRV, and the importance of ocean biogeochemistry models as critical tools for predicting when and where mCDR signals will be detectable using available sensors. Overall, our findings suggest that commercially available pCO 2 sensors and some pH sensors will form an important backbone for mCDR MRV tasks, though complete MRV characterization will require these data to be used in combination with other tools.

OAE↗

Comparing Constant and Transient Membrane Transport Parameters for Use in Wave Desalination Models

Directly pressurizing seawater for desalination with reverse osmosis membranes via wave motion is a promising and sustainable method for producing freshwater in coastal regions. However, such a system could result in significant pressure fluctuations and a departure from conventional steady-state desalination operations. This study sought to assess if membrane transport parameters (apparent water and salt permeability) should be modeled as transient or constant in solution–diffusion-based modeling efforts of dynamically operated desalination systems, such as those coupled to wave power. Two approaches were used to model membrane transport parameters: one considered each parameter to be a function of the net driving pressure of the system, and the other assumed they were constant across all conditions. A pilot-scale system was used to conduct steady-state and controlled ramping experiments. Data from steady-state experiments were used to calculate transient and constant transport parameters. Parameter combinations were used in a simulation model to predict water flux and effective permeate salinity, and simulation outcomes were compared against experimental ramping results. The transient relationships for both water and salt permeability produced the most accurate results for water flux and comparable results for effective permeate salinity. Development of such relationships would be unique to a specific system but could be valuable in modeling wave-driven desalination systems across the wide range of operating conditions they experience.

13 HYDRO ENERGY↗

Numerical simulation of compressible fluid-dynamics in the chamber of inertial fusion energy systems

Here, this paper aims to establish new and innovative modeling capabilities for analyzing chambers in Inertial Fusion Energy (IFE) systems. IFE is emerging as a promising method to achieve fusion power production, but several challenges must be overcome to develop an IFE pilot plant or deploy commercial IFE systems. These challenges are both theoretical and technical, encompassing a deeper understanding of the underlying physical phenomena and the development of new technologies and materials. One of the needs is to develop mathematical models to describe IFE systems and numerical tools to simulate them. This paper contributes to this endeavor by presenting a new OpenFOAM solver for IFE systems, focusing on gas dynamics in their chambers. The analysis and development of chamber designs will play a significant role in the transition from single-shot experiments to high-repetition rates, as there is a need to protect the chamber walls from the intense radiation fields produced by fusion reactions. A promising design option, normally referred to as thick wall chamber design, consists in using lithium or molten salt jet arrays within the chamber. A critical phenomenon is the venting of high-pressure gases from the center to the external part of the chamber, passing through the blanket array. This process involves the propagation and attenuation of strong pressure waves, requiring suitable modeling approaches for compressible fluid-dynamics. The solver proposed in this work implements a multi-material hydrodynamics model tailored to accurately describe the non-linear propagation of pressure waves while avoiding numerical oscillation issues typical of high-velocity compressible simulation. This solver is verified against numerical test cases, validated against experimental data, and applied to the analysis of the High-Yield Lithium-Injection Fusion-Energy (HYLIFE-I) concept. The relevance of this paper is threefold. Firstly, it contributes to developing and testing modeling approaches for compressible fluid-dynamics phenomena, with specific focus on the new and unexplored topic of IFE thick-liquid-wall blanket modeling. Secondly, it marks one of the first applications of the OpenFOAM library in the research field of IFE systems. Finally, the investigated problem is of practical interest for IFE developers, as it provides useful indications about relevant phenomena in pressure wave propagation in the chamber of these systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrating DOE ASCR Computing into HEPCloud through GlideinWMS

Fermilab's HEPCloud facility expands the laboratory's computing capacity by provisioning resources beyond the local grid, using GlideinWMS to deliver pilots to where experiments such as CMS and DUNE run. The High-Performance Computing (HPC) facilities of the DOE Office of Advanced Scientific Computing Research (ASCR) are a growing part of that pool. HEPCloud currently provisions NERSC over SSH, but NERSC is moving away from that path as it adopts multi-factor authentication and directs automated access to its Superfacility API and the DOE Integrated Research Infrastructure (IRI) APIs. Maintaining and extending access across the ASCR ecosystem now requires provisioning through these interfaces. This work adds new pilot submission paths to GlideinWMS for the NERSC Superfacility API, IRI, and Globus Compute. Each uses the provisioning model GlideinWMS already applies to batch resources, so experiments can run on ASCR computing resources without changes to their existing workflows. This work finally presents a comparison of the paths to guide which interfaces are best suited for different workflows.

Majumder, Meghanto [U. Houston (main)]↗

Scaling High-Resolution Soil Organic Matter Composition to Improve Predictions of Potential Soil Respiration Across the Continental United States

Despite the importance of microbial soil organic matter (SOM) respiration in regulating the flux of carbon between soils and the atmosphere, soil carbon cycling models remain primarily based on climate and soil properties, leading to large uncertainty in predictions. To address this knowledge gap, we analyzed high-resolution water-extractable SOM profiles from soil cores collected across the United States by the 1,000 Soils Pilot of the Molecular Observation Network. Our innovation lies in using machine learning to distill thousands of SOM formula into tractable units; and it enables integrating data from molecular measurements into soil respiration models. In surface soils, SOM chemistry provided better estimates of potential soil respiration than soil physicochemistry, and using them combined yielded the best prediction. Overall, we identify specific subsets of organic molecules that may improve predictions of global soil respiration and create a strong basis for developing new representations in process-based models.

54 ENVIRONMENTAL SCIENCES↗

Synthesis of results for Brine Availability Test in Salt (BATS) DECOVALEX-2023 Task E

In the 2023 phase of the international collaborative DECOVALEX modeling project, Task E focused on understanding thermal, hydrological, and mechanical (THM) processes related to predicting brine migration in the excavation damaged zone around a heated excavation in salt. Salt is attractive as a disposal medium for radioactive waste because it is self-healing and is essentially impermeable and non-porous in the far field. Investigation of the short-term, near-field behavior is important for radioactive waste disposal because this early period strongly controls the amount of inflowing brine. Brine leads to corrosion of waste forms and waste packages, and possible dissolution of radionuclides with brine transport being a potential transport vector to the accessible environment.The Task was divided into steps. Step 0 included matching unheated brine inflow data from boreholes at the Waste Isolation Pilot Plant (WIPP) and matching temperature observations during a Brine Availability Test in Salt (BATS) heater test. Step 1 included validation of models against a thermo-poroelastic analytical solution, and two-phase flow around an excavation. Finally, Step 2 required all the individual components covered in steps 0 and 1 to come together to match observed brine inflow behavior during the same BATS heater test.There were a range of approaches from the teams, from mechanistic to prescriptive. Given the uncertainties in the problem, some teams used one- or two-dimensional models of the processes, while other teams included more geometrical complexity in three-dimensional models. Task E was a learning experience for the teams involved, and feedback from the modeling teams has led to changes in follow-on BATS experiments at WIPP. The primary Task E lessons learned were the impact of hydrologic initialization methods (wetting up vs. drying down), the difference between confined and unconfined thermal expansion, and the large changes in permeability associated with heating and cooling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Consistent performance of large language models in rare disease diagnosis across ten languages and 4917 cases

Background Large language models (LLMs) are increasingly used medicine for diverse applications including differential diagnostic support. The training data used to create LLMs such as the Generative Pretrained Transformer (GPT) predominantly consist of English-language texts, but LLMs could be used across the globe to support diagnostics if language barriers could be overcome. Initial pilot studies on the utility of LLMs for differential diagnosis in languages other than English have shown promise, but a large-scale assessment on the relative performance of these models in a variety of European and non-European languages on a comprehensive corpus of challenging rare-disease cases is lacking. Methods We created 4917 clinical vignettes using structured data captured with Human Phenotype Ontology (HPO) terms with the Global Alliance for Genomics and Health (GA4GH) Phenopacket Schema. These clinical vignettes span a total of 360 distinct genetic diseases with 2525 associated phenotypic features. We used translations of the Human Phenotype Ontology together with language-specific templates to generate prompts in English, Chinese, Czech, Dutch, French, German, Italian, Japanese, Spanish, and Turkish. We applied GPT-4o, version gpt-4o-2024-08-06, and the medically fine-tuned Meditron3-70B to the task of delivering a ranked differential diagnosis using a zero-shot prompt. An ontology-based approach with the Mondo disease ontology was used to map synonyms and to map disease subtypes to clinical diagnoses in order to automate evaluation of LLM responses. Findings For English, GPT-4o placed the correct diagnosis at the first rank 19.9% and within the top-3 ranks 27.0% of the time. In comparison, for the nine non-English languages tested here the correct diagnosis was placed at rank 1 between 16.9% and 20.6%, within top-3 between 25.4% and 28.6% of cases. The Meditron3 model placed the correct diagnosis within the first 3 ranks for 20.9% of cases in English and between 19.9% and 24.0% for the other nine languages. Interpretation The differential diagnostic performance of LLMs across a comprehensive corpus of rare-disease cases was largely consistent across the ten languages tested. This suggests that the utility of LLMs in clinical settings may extend to non-English clinical settings.

Artificial intelligence↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lepton-flavor-violating ALP signals with TeV-scale muon beams

We explore the feasibility of using TeV-energy muons to probe lepton-flavor-violating (LFV) processes mediated by an axion-like particle (ALP) a with mass O(10 GeV). We focus on µτ LFV interactions and assume that the ALP is coupled to a dark state χ, which can be either less or more massive than a. Such a setup is demonstrated to be consistent with χ being a candidate for dark matter, in the experimentally relevant regime of parameters. We consider the currently operating NA64-µ experiment and proposed FASERν2 detector as both the target and the detector for the process µA → τA a, where A is the target nucleus. We also show that a possible future active muon fixed-target experiment operating at a 3 TeV muon collider or in its preparatory phase can provide an impressive reach for the LFV process considered, with future FASERν2 data providing a pilot study towards that goal. The implications of the muon anomalous magnetic moment (g - 2) µ measurements for the underlying model, in case of a positive signal, are also examined, and a sample UV completion is outlined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of ionization and transport on pedestal density structure in DIII-D and Alcator C-Mod

Abstract This paper investigates the role of ionization on the pedestal structure using both measurements and modeling for H-mode plasmas on DIII-D and Alcator C-Mod to enhance our ability to predict pedestal behavior in future pilot plants. The impact of the neutral penetration depth on the pedestal density is investigated using dimensionally matching hydrogen and deuterium DIII-D H-mode discharges at low and high electron density. The DIII-D Lyman- α diagnostic measurements show that hydrogen neutrals penetrate deeper inside the plasma on both the high field and low field side, while the pedestal electron density structure is similar for both isotopes. However, as the opaqueness increases we observe that the pedestal density gradient becomes stiff, similar to prior observations on DIII-D and C-Mod (Mordijck 2020 Nuclear Fusion 60 082006). In addition, these results also confirm prior measured and modeled poloidal asymmetries in neutral densities, indicating that to make transport predictions, 2D neutral modeling is necessary. The first direct validation of SOLPS-ITER for the measured brightness, emissivity and neutral densities for three different confinement regimes on C-Mod is introduced. The SOLPS-ITER model shows good agreement, within the constrains of the model for all regimes. In addition, a comparison of SOLPS-ITER modeling for DIII-D and C-Mod shows that as opaqueness increases, the role of divertor fueling and thus poloidal asymmetries in the neutral density profiles decreases. Based on these experimental and modeling results we estimate the size of a potential particle pinch using typical values for the diffusion coefficient for both DIII-D and C-Mod H-mode discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A real-time distributed solid oxide electrolysis cell (SOEC) model for cyber-physical simulation

System integration and dynamic operability between SOEC and balance-of-plant (BoP) components are major technical challenges before realizing rapid load following of SOEC systems. Cyber-physical simulation (CPS) is a leading-edge digital engineering approach and is regarded as the next step beyond Digital Twins. CPS approach can be used to research SOEC system integration and develop dynamic controls prior to actual pilot testing without using a real SOEC. To seamlessly couple with BoP hardware and access non-observable operational parameters (e.g., local temperature gradient) during transients, a distributed one-dimensional (1D) real-time SOEC model was developed. Its real-time execution was demonstrated for 20 to 640 nodes at the fixed time step of 5 ms. A higher excess air ratio enabled smaller local temperature gradients on SOEC solid materials and faster transients upon current density step change from 0.15 to 0.55 A cm -2 . During the transients, the magnitude of the peak temperature gradient nearly doubled in 10 s from -3.5 to -5.9 °C cm -1 . This represents a significant operating risk that can impact the dynamic operability of SOEC systems. In addition, the local temperature gradient was found to change directions on all nodes in SOEC solid materials, with the greatest impact on the upstream nodes. The SOEC model was also tested at the thermal neutral voltage using actual process air flow parameters as variable model inputs. Variable process air temperatures were found to induce alternating local temperature gradients on SOEC solid materials. These are new operational mechanisms for SOEC degradation relevant for load following operational modes yet distinct from previous reports. To mitigate these unfavorable features, the SOEC can be operated at voltages that are slightly (±20 mV) deviated from the thermal neutral voltage. Here, the corresponding net thermal energy change was less than 1.6% of the electric power consumption. This 1D real-time SOEC model established the basis of cyber-physical simulation of SOEC hybrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying UAS Observation Error Variance Used in Data Assimilation Systems and Its Impact on Predictive Skill

Observation error determines the weights of the observations and background state used in data assimilation to generate analyses. Quantifying observation error is critical for the optimal assimilation of observational data sets. Uncrewed Aircraft System (UAS) observations have shown potential benefits in filling observational gaps in the lower atmosphere; however, characterization of their error characteristics has been limited. To optimize the use of UAS observations in numerical weather prediction, UAS observation error is estimated based on the 3‐cornered hat diagnostic approach which uses three independent estimates of the atmospheric state. This approach is applied to data from the 2018 Lower Atmospheric Profiling Studies at Elevation‐a Remotely‐piloted Aircraft Team Experiment field campaign using collocated UAS and rawinsonde observations along with output from a set of convection‐permitting model simulations. The estimated observation error values for UAS temperature, wind, and relative humidity measurements were found to be only weakly dependent on height AGL with mean values equal to 0.5°C, 0.8 m s −1 , and 3%, respectively. Only the newly estimated observation error for temperature differed from that previously used to assimilate commercial aircraft observations into global models (1.0°C). However, using this reduced temperature observation error produced more accurate mesoscale analyses and forecasts of both terrain‐driven flows and convection initiation generated by colliding outflow boundaries within the San Luis Valley of Colorado.

54 ENVIRONMENTAL SCIENCES↗

A high fidelity and user-friendly equation-oriented optimization model for carbon capture using a novel water-lean solvent

Research Triangle Institute (RTI) International and SLB have developed a novel water-lean solvent technology for carbon capture, demonstrating low specific reboiler duty (SRD) values at capture rates exceeding 90%. At the Technology Centre Mongstad (TCM) pilot plant, the technology achieved an SRD of 2.55 GJ/t-CO2 at 95% capture, utilizing an intercooler and a 5°C temperature approach in the lean/rich solvent cross exchanger. To meet varying carbon capture targets for Front End Engineering and Design (FEED) studies and to enable real-time optimization and advanced process control, an efficient optimization model is required. This model needs to minimize energy demand for a given capture rate and determine optimal operating parameters in response to fluctuating flue gas conditions. While an existing Aspen Plus simulation model, developed by RTI and SLB, accurately matches TCM plant data, its sequential modular (SM) strategy is too slow for real-time applications due to recycle streams and tight heat integration inherent in solvent-based carbon capture processes. Although an equation-oriented (EO) modeling strategy is more suitable for optimizing these processes, its adoption has been limited by several factors: feature limitations in Aspen Plus EO mode (e.g., lack of balance block support), a less user-friendly interface for variable identification and loop solving, complex troubleshooting of convergence issues, and the necessity for accurate initial values.

carbon capture↗

State of Innovation 2025: Progress in Accelerating Next-Generation Cement and Concrete Technologies

The cement and concrete sectors are entering a decisive period as next-generation technologies advance from laboratory research to demonstration, early deployment, and first-of-a-kind commercial plants. Building on the 2024 State of Innovation report, the 2025 outlook highlights both the rapid acceleration of innovation and the urgent need for coordinated action across the value chain. Venture capital activity into the cement and concrete space stabilized following the record surge of 2022-2023, yet landmark financings, such as Sublime Systems' $200 million round and Terra CO2's $124 million Series B, signal continued investor confidence in companies approaching commercialization. Corporate procurement has become a powerful new catalyst, with Microsoft, Amazon, and CRH (Cement Roadstone Holdings) Ventures providing long-term commitments that underpin the first wave of next-generation cementitious products. The sector is shifting from early-stage experimentation toward the scaling of well-capitalized leaders capable of bridging the critical "capitalization gap." Early innovators continue to expand the toolkit through novel binders, electrochemical cements, biogenic limestone, and carbonate mineralization pathways. Going into 2026, cost competitiveness, durability validation, and scalability enabled by resilient supply chains remain the decisive factors for market adoption. At the 2025 Next Generation Cement and Concrete Critical Technologies Meeting, attendees emphasized dual-track funding strategies that integrate federal grants with private capital as key to enabling market breakthrough. State programs and corporate demand are sustaining momentum, while successful companies increasingly demonstrate both economic value and reduced dependence on imported materials. The National Concrete Pavement Technology Center and others underscored that broad integration of next-generation materials will hinge on standards compatibility, verified field performance, and workforce readiness. Colorado continues to serve as a proving ground through pilot programs that combine supplier training, phased implementation, and real-world data to de-risk innovation and provide replicable models for other regions. The 2025 Cement and Concrete Critical Technologies Workshop reinforced that scaling next-generation materials will require alignment among technology innovation, performance validation, and market demand. Stakeholders must move beyond siloed efforts toward collaborative frameworks that coordinate standards, funding, and infrastructure deployment. As a neutral convener and technical validator, the National Laboratory of the Rockies (NLR) plays a pivotal role in bridging innovation and market adoption through collaborative research, technology validation, and entrepreneurship programs. By uniting innovators, incumbents, policymakers, contractors, and investors, NLR and its partners are helping chart a credible pathway toward widespread commercialization in the decade ahead.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗