Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “phasor measurement units”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

High-Impedance Non-Linear Fault Detection via Eigenvalue Analysis with low PMU Sampling Rates

This work presents a hybrid data-driven and physics-based framework for high-impedance fault detection in power systems. An innovative method based on eigenvalue analysis is expanded and validated. Phasor Measurement Unit data is used to estimate eigenvalues corresponding to the powerlines being monitored. The projection and drift of these eigenvalues is then tracked and evaluated. Faults are detected as they drive eigenvalues outside of their normal zones. Eigenvectors are leveraged to support and validate the decisions made by the main algorithm. This technique holds several advantages over contemporary techniques in that it utilizes technology that is already deployed in the field, it offers a significant degree of generality, and so far it has displayed a very high-level of sensitivity without sacrificing accuracy. Validation takes place in the form of simulations in the IEEE 13 Node System considering a popular high-impedance non-linear fault model. Test results are encouraging indicating potential for real-life applications.

Paramo, Gian↗

Proactive Frequency Stability Scheme via Bayesian Filters and Synchrophasors

Underfrequency (UF) load shedding schemes are traditionally implemented in two ways: One approach is based on manual load shedding, with system operators requesting loads to be shed ahead of anticipated stressful operating conditions. Manual load shedding is usually done through phone calls. The second method is automatic load shedding via underfrequency relays. Using static static settings, these schemes can be designed to operate in stages and drop previously identified loads. The main limitation of traditional load shedding schemes is that they are reactive and leave little room for optimized corrective actions. This work presents a proactive and automatic underfrequency load shedding solution for power systems. Measurements are captured via phasor measurement units (PMUs) at relatively low sampling rates of 30 Hz. These measurements are then processed by particle filters who predict the future state of the system's frequency. Based on these predictions excess load is determined and shed. Comparative case studies are performed in simulated environments. Easy-to-implement models, without hard-to-derive parameters, highlight potential aspects for real-life implementation.

Paramo, Gian↗

State Estimation for Distribution Networks with Asynchronous Sensors Using Stochastic Descent: Preprint

This paper investigates the problem of state estimation for distribution networks with asynchronous sensors comprising of a mix of smart meters and phasor measurement units (PMUs) with multiple sampling and reporting rates. We consider two independent scenarios of state estimation and tracking, with either voltages or currents as states. With these two sets, we investigate estimation under (a) full data, assuming all measurements are available and (b) limited data, where an online algorithmic approach is adopted to estimate the possibly time-varying states by processing measurements as and when available. The proposed algorithm, inspired by the classical Stochastic Gradient Descent (SGD) approach updates the states based on the previous estimate and the newly available measurements. Finally, we demonstrate the estimation and tracking efficacy through numerical simulations on the IEEE-37 test network, while also highlighting how estimation with currents as states leads to faster convergence.

asynchronous sensors↗

Real-time Event Detection Using Rank Signatures of Real-world PMU Data

Timely detection of power system events is a crucial task, which can facilitate the implementation of remedial actions to improve reliability, resiliency, and security of the system. Meanwhile, the widespread deployment of phasor measurement units (PMUs) makes it possible to develop data-driven event detection techniques. However, relying purely on data without incorporating domain knowledge for the event detection task in power systems poses substantial security and stability risks due to issues associated with data misinterpretation and model accuracy. In this regard, we propose a real-time event detection method using real-world PMU data by incorporating domain knowledge to adequately capture the event signatures. Specifically, we track the change in rank signatures of PMU data to accurately localize the events. To optimize the detection process, we incorporate an offline Bayesian optimization algorithm to tune the parameters by efficiently searching for the best values. The experiments using the real-world PMU dataset from a U.S. interconnection show that the proposed event detection approach can efficiently detect the events from PMU data streams with high accuracy.

Ghasemkhani, Amir↗

Weakly Supervised Event Classification Using Imperfect Real-world PMU Data with Scarce Labels

This paper studies event classification using imperfect real-world phasor measurement unit (PMU) data with scarce event types (labels). By investigating the real-world PMU data, it is observed that most real-world PMU data's event type is unknown, which makes it challenging to directly use such dataset to build event classifiers as existing classification techniques require high-quality training data with known event type (i.e., label). To address this challenge, a weakly supervised learning based event classification approach is developed, which can use noisy and low-quality PMU data for the training. First, data quality issues are fixed using data preprocessing techniques and then event features are constructed from the PMU data. Using these features, a series of labeling functions are learnt to generate initial estimates of the labels of large amounts of unlabeled PMU data. As the labeling functions are learnt using the same data with scarce labels, the label estimates from the labeling functions can be correlated, noisy, and bias. To enhance these initial estimates, a generative model is developed to characterize the dependencies among the estimated labels, based on which better labels are obtained for training event classifiers. Numerical experiments using the real-world dataset from the Western Interconnection of the U.S. power transmission grid show that the proposed weakly supervised event classifier trained using the dataset with only 5% labeled data can achieve 78.4% classification accuracy.

Liu, Yunchuan↗

Online Detection of Power Grid Anomalies via Federated Learning

Data from sensors is critical for advanced applica- tions that support efficient, reliable, and resilient electric grid operations. Historically, data from phasor measurement units (PMU) has been utilized to develop a wide variety of wide area control and protection applications suitable for power grid control centers. However, until now, most of these could not be deployed for automated operations due to a set of data corruption challenges and uncertainty in the incoming data pipeline. In this paper, we address the problem of detecting different variety of anomalies that are evident in different high- speed power grid measurements. The paper discusses a workflow for handling problems with data acquisition and highlights some of the key findings suitable for anomaly detection in a centralized and distributed environment. The effectiveness of the proposed method was demonstrated with results utilizing realistic PMU datasets

Shinkle, Matthew W.↗

PMU Data Quality and Sensor Health Monitoring

Phasor Measurement Units (PMUs) play a critical role in the evolution of the electric power industry by providing high-precision, real-time monitoring of essential power system metrics. However, effectively detecting abnormalities and critical events from PMU data is a complex task, complicated by intricate temporal patterns, a scarcity of labeled data for training algo- rithms, and constraints on online computational power. In this study, we apply TranAD, an innovative algorithm that combines transformer architectures with the refinement of adversarial learning, to both synthetic and real-world PMU datasets for developing a data quality and sensor online health monitoring platform for utilities. Our findings reveal that TranAD not only provides efficient detection and localization but also enhances the detail with which abnormalities are detected, marking a a significant step forward in the field of clean data acquisition processes for power system monitoring

deep neural network, machine learning (ML)↗

Model Agnostic Bayesian Framework for Online Anomaly/Event Detection in PMU Data

Phasor measurement units (PMU) are integral to the modernization and automation plan of the electric power industry. A PMU data signature contains system-level events (e.g., faults, generation/load change, etc.) and any measurement/device-related errors. Therefore, the reliable and resilient operation of power systems is equivalent to the quality of the PMU data and the situation awareness provided by its data signature. Despite recent progress, current state-of-the-art methods are not fool-proof and have certain limitations tracing an error/abnormality to sensor sub-components and grid systems. This is because of technical challenges imposed by the scarcity of the labeled information, loss of data quality, and non-stationarity of data. In this paper, we consider the online PMU data stream as an output of a stochastic process and pose the anomaly/event detection as a changepoint detection problem dealing with detecting parameter changes in the underlying stochastic processes. The proposed model-agnostic framework relies on: (a) feature extraction utilizing the minimum volume enclosing ellipsoids (MVEE) method from raw PMU observations and (b) a Bayesian framework of changepoint detection. The validity of the proposed methodology is discussed through numerical experiments on real-world utility-scale PMU data.

Hossain, Ramij Raja↗

Online Output-Based Inertia Estimation of Modern Power Systems

The overall inertia of modern power systems is drastically impacted by the penetration level of converter-based resources (CBRs). The intermittent output of CBRs and their dependence on the weather conditions affirm the need for a realtime inertia estimation approach. This can help the transmission system operators(TSOs) to be continuously aware of the changes in the system inertia and to take suitable control actions. This paper is a step forward to a totally data-driven framework for power system inertia estimation using the available measurements from the phasor measurement units (PMUs). This inertia estimation is done based on the spectral analysis of the so-called Koopman linear operator. Koopman operator considers the relationship between the system's inertia and its dynamical response to slight disturbances in the load. Simulation results show that Koopman operator can approximate the system behavior in a reconstructed linear space hence inertia constant is estimated accurately.

data-driven↗

A Practical On-line Framework for a Modified Energy Detector by Whitening Ambient PMU Data

A key application of Phasor Measurement Units (PMUs) is power system oscillation detection. An energy detector is a straightforward detection method, but setting thresholds requires extensive and time consuming baselining of data. This paper proposes a novel on-line method of whitening PMU measurements supporting a framework for detecting forced oscillations without requiring extensive baselining. An example of 24 hours of actual PMU data illustrates how a forced oscillation is very visible in the energy signal of the whitened data, while being hard to detect in the colored ambient noise. With this framework, the statistical theory for setting thresholds without baselining is much more straightforward and is the focus of future work.

Xu, Zikai↗

Applying Utility's Advanced Grid Technologies to Improve Resiliency of a Critical Load

The US DOE Office of Electricity's Energy Storage Program's joint R&D work with the Cordova Electric Cooperative (CEC) has deployed several advanced grid technologies that are providing benefits today to Cordova Alaska's electricity users. Advanced grid technologies deployed through DoE co-funded R&D include a 1MW Battery Energy Storage System (BESS), and enhanced monitoring including Phasor Measurement Units (PMU's) to help better understand the operational impacts of the added BESS. This paper will highlight key accomplishments to-date in deploying and using advanced grid technologies, and then outline the next phase of work that will use these technologies to implement an operating scheme to reconfigure the utility's distribution system and utility resources including BESS to provide emergency back-up power to a critical load: the Cordova Community Medical Center (CCMC). This paper will include additional insights on the use of utility resources to support critical loads via case study examples by the National Rural Electric Cooperative Assoc. (NRECA).

BESS↗

Novel Data Driven Noise Emulation Framework using Deep Neural Network for Generating Synthetic PMU Measurements

Sensors play a critical role in supporting day-to-day grid operations and they are essential to operator’s decision-making process. Furthermore, sensors and sensor behaviors need to be emulated with grid simulations to perform modeling studies and to design cutting edge power systems applications. Ensuring the accurate behavior of these applications requires accurate emulation of sensors and pertinent signals. However, most grid simulators and modeling tools assume either zero error scenarios or simplistic noise models that may not always correlate to real-world sensors. To address the above issue, this work presents an initial study on the noise characteristics of phasor measurement units (PMUs), along with models for recreating their unique noise signatures. The proposed methods (both analytical and machine-learning-based) provide a substantial increase in a sensor’s model fidelity, a feature that can be leveraged by an end-user application to yield more accurate system representations. The proposed methods were then applied to micro PMU data from the EPFL microgrid campus to extract sensor noise profiles. This data was used to train a deep learning model, which was tested to emulate the noise characteristics present in actual signals. Based on the observed results and the employed data-driven methodology, the proposed methods may be adapted to replicate the behavior of other grid sensors and power new applications capable of detecting sensor degradation and eventual device failures in near real-time.

PMU, noise emulation, synthetic measurements, deep↗

Open Source Synergy: Developing and Validating PMU Data Analysis Techniques Using Open Source Tools and Datasets

This paper presents an exploration into the development and validation of data analysis approaches for Phasor Measurement Units (PMUs) using open-source datasets and tools. Various methods for event detection, event classification, frequency response, and oscillation analysis were tested. We leverage the capabilities of Archive Walker (AW), the Frequency Response Analysis Tool (FRAT), and the Oscillation Baselining and Analysis Tool (OBAT), all open-source tools, for efficient processing and analysis of synchrophasor data. The open-source Transmission Signature Library (TSL) dataset was employed as a dataset for a comprehensive evaluation to assess the performance and reliability of the proposed methods.

PMU, event analysis, oscillation, Frequency Respon↗

Event Detection and Classification Using Machine Learning Applied to PMU Data for the Western US Power System

Smart grid technology enhances our comprehension and reliability of the power grid, leveraging Phasor Measurement Unit (PMU) data—time-synchronized, high-frequency measurements gathered across the US power grid. This paper employs machine learning techniques to effectively analyze the vast PMU data in Wide Area Monitoring Systems (WAMS) for power grid event detection and classification. Analyzing several months of real-world PMU data, the paper focuses on machine learning for fast, precise event detection and classification, corroborated by utility event logs. Practical challenges like feature extraction, dimensionality reduction, and model selection are addressed. A novel feature yielding improved results is discovered, and a supplementary algorithm for detecting small power grid faults is developed. The final algorithm is validated using a month-long real PMU data set, demonstrating its capability in accurately identifying power grid events in near real-time.

machine learning, event detection, PMU↗

Cyber-Power Co-Simulation for End-to-End Synchrophasor Network Analysis and Applications

The resiliency, reliability and security of the next generation cyber-power smart grid depend upon efficiently leveraging advanced communication and computing technologies. Also, developing real-time data-driven applications is critical to enable wide-area monitoring and control of the cyber-power grid given high-resolution data from Phasor Measurement Units (PMUs). North American Synchrophasor Initiative Network (NASPlnet) provides guidance for PMU data exchanges. With the advancement in networking and grid operation, it is necessary to evaluate the performance of different data flow architectures suggested by NASPInet and analyze the impact on applications. Therefore, we need a cyber-power co-simulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents an end-to-end automated and user-driven cyber-power co-simulation using NS3 to model communication networks, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application utilizing PMU data in an IEEE 39 bus test system is presented using this cosimulation testbed.

Mustafa, Hussain M.↗

Coordinated Control of Natural and Sub-Synchronous Oscillations via HVDC Links in Great Britain Power System

Conventional power oscillation damping (POD) controllers have been designed to be effective in damping either inter-area low-frequency oscillations (LFO) or sub-synchronous oscillations (SSO). For those POD controls, model-based control design method has been widely implemented with wide-area feedback signals from phasor measurement units (PMU). However, the model accuracy of a large realistic power system can hardly be guaranteed, which will finally impact the POD damping performance. In this paper, a measurement-based method is proposed for POD design using High Voltage Direct Current links (HVDC) to realize the coordinated control of both LFO and SSO. For each type of oscillations, a band-pass filter is added to avoid the interactions between different modes. Case studies are carried out on the Great Britain 36-bus power system model with multiple HVDC links in DIgSILENT/PowerFactory. Simulation results demonstrate that the proposed PODs are effective in damping inter-area LFO and SSO simultaneously.

Zhao, Yi↗

Synchrophasor Data Anomaly Detection on Grid Edge by 5G Communication and Adjacent Compute

The fifth-generation mobile communication (5G) technology offers the opportunities to enhance the grid real-time monitoring. The 5G-enabled phasor measurement units (PMUs) features flexible positioning and cost-effective long-term maintenance, without constraints of fixing wire. This paper is the first to demonstrate the applicability of 5G in PMU communication, and the experiment was carried out at Verizon non-standalone testbed at Pacific Northwest National Laboratory (PNNL) Advanced Wireless Communication lab. The performance of 5G-enabled PMU communication setup is reviewed and discussed in this paper, and the paper presents a real-time dynamic linear model (DML) based synchrophasor data anomaly detection application. Last but not least, the practicability of implementing 5G for wide-area protection strategies is explored and discussed by analyzing the experimental results.

5G, Synchrophasor data, machine learning, anomaly ↗

Synchrophasor Data Compression Under Disturbance Conditions via Cross-Entropy-Based Singular Value Decomposition

The increasing deployment of phasor measurement units and the advances of their reporting rates are challenging the present data centers in terms of storing and analyzing large-volume data. Under power system disturbance conditions, it is difficult to retain critical information while compressing the synchrophasor data effectively. This article combines the cross entropy and the singular value decomposition, proposing a novel model to compress the synchrophasor data to an extremely small size yet keep superior accuracy. The proposed model is extensively tested and compared with the state-of-the-art algorithms using the simulated and the FNET/GridEye field-collected data. The result indicates that the proposed algorithm has superior performance in compressing the data while retaining critical information under disturbance conditions.

42 ENGINEERING↗