Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “phasor measurement unit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Electrical circuit control in power systems

Electrical circuit control techniques in power systems are disclosed herein. In one embodiment, a supervisory computer in the power system can be configured to fit phasor measurement data from phasor measurement units into a Gaussian distribution with a corresponding Gaussian confidence level. When the Gaussian confidence level of the fitted Gaussian distribution is above a Gaussian confidence threshold, the supervisory computer can be configured to perform an ambient analysis on the received phasor measurement data to determine an operating characteristic of the power system. The supervisory computer can then automatically applying at least one electrical circuit control action to the power system in response to the determined operating characteristic.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Local Phasor-Based Control of DER Inverters for Voltage Regulation on Distribution Feeders

We introduce a new control paradigm termed Phasor-Based Control (PBC) to coordinate Distributed Energy Resources (DER) for improved voltage regulation and other objectives. PBC is a multi-layer control framework where the state of the distribution grid is represented by voltage phasors, and Phasor Measurement Units (PMUs) measure the state at critical points in the distribution grid. In the PBC paradigm, a supervisory controller (S-PBC) sets phasor targets which local controllers track. In this paper, we propose a Proportional Integral (PI) implementation for the local control layer (LPBC), to regulate real and reactive power output of distributed inverters to track a voltage phasor target computed by the supervisory layer. We tune the PI controller gains offline with a genetic algorithm that yields better performance than the Ziegler-Nichols method. We benchmark the proposed L-PBC controller against droop volt-var control (DVVC) and observe improved voltage regulation in simulation on the IEEE 13 node unbalanced test feeder (IEEE 13NF). Furthermore, by means of numerical simulation we observe the response of the L-PBC controllers to small and large grid disturbances. Simulations on larger feeders, IEEE 123-node and 647-node, demonstrate challenges with tuning controllers in setups with different amounts of power-voltage coupling.

42 ENGINEERING↗

Development and Evaluation of a Cost-Effective Behind-the-Meter Synchronized Measurement Unit for Enhanced Grid Integration

This paper presents the development of the Inverter Based Resource Monitor (IBRM), an innovative behind-the-meter synchronized measurement unit (SMU) tailored for integration with inverter-based resources (IBRs). The IBRM distinguishes itself as a highly accurate and cost-effective SMU, offering facile deployment and connectivity to IBRs. It is equipped to conduct real-time voltage and current waveform analyses, serving as a phasor measurement unit (PMU) with exceptionally rapid synchrophasor transmission capabilities. The device incorporates a cutting-edge dual-core architecture designed to minimize sampling delays inherent to its microprocessor, thereby enhancing the precision of synchronized waveform measurements. Moreover, the IBRM is adept at recording high-fidelity waveform data, capturing nuances such as waveform distortions, high-order harmonics, and wide-band oscillations prevalent in power grids with substantial IBR presence. A prototype of the IBRM has been constructed and subjected to rigorous testing to assess its functional capabilities and measurement precision, utilizing both idealized signal generators and a real-world off-grid inverter setup as benchmarks.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

Real Time Effective Impedance Estimation for Power System State Estimation

Here, we introduce two tools-the Effective Impedance State Estimator (EISE), and the Real Time Effective Impedance Estimator (RTEIE). The EISE is novel in that it is an entirely data-driven state estimator, and does not require a network model. Thus, the EISE is well suited for applications in which an accurate network model is not available. Instead of using a network impedance model, the EISE uses an effective impedance network model that is learned online by the RTEIE. The RTEIE recursively estimates the effective impedance network model using phasor measurement unit (PMU) measurements. The mathematical reasoning for using an effective impedance model, rather than a full network impedance model, is given. The recursive estimation framework allows the RTEIE to take the entire history of phasor measurements into account to produce a model estimate, while still adjusting to changes in the network impedance due to external factors such as topology changes and temperature. The merits of the RTEIE and EISE are demonstrated by comparing the accuracy of the EISE with a conventional state estimator on a toy network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measurement Adequacy for Monitoring Data Center Oscillations

Artificial intelligence (AI) training data centers with periodic load profiles can induce sustained grid oscillations across a wide frequency range, making accurate monitoring essential for reliable power system operation. This report evaluates the adequacy of existing measurement systems for monitoring such oscillations, focusing on phasor measurement units (PMUs) and point-on-wave (POW) measurement systems. The analysis shows that while PMUs are highly effective for monitoring low-frequency electromechanical oscillations, they have inherent limitations in accurately representing higher-frequency oscillations due to constraints imposed by reporting rates and the bandwidth of phasor estimation filters. Even when configured with higher reporting rates, the filtering inherent in the phasor estimation process can significantly attenuate oscillation magnitudes, potentially leading to underestimation of oscillatory behavior. This has important implications for compliance and performance monitoring of large loads. To address the limitations associated with PMU-based monitoring, the report examines the use of high-resolution POW measurements, which can capture oscillations across a broader frequency range. However, continuous POW monitoring introduces practical challenges related to large data volumes, communication bandwidth, and real-time data processing. For this reason, the report also discusses emerging approaches that use POW measurements as a complementary capability alongside PMUs to improve observability of oscillations from large data center loads.

47 OTHER INSTRUMENTATION↗

Alignment Method for Synchronized Phase Angle Measurement With Presence of Practical Time Shift

Synchronized Phase Angle Measurements (SPAMs) are widely used in power systems in the applications of situational awareness. However, the practical time shifts can lead to unexpected angle differences among Phasor Measurement Units (PMUs) manufactured from various vendors. Moreover, since most of PMUs calculate phase angle via Discrete Fourier Transform based approaches, this issue becomes even worse under the off-nominal frequency condition. To mitigate the impact of practical timing shift, this letter presents a fast method to rectify the SPAM for appropriate alignment. To verify the performance of the proposed method, laboratory and field tests have been conducted by implementing the method in PMUs and phasor data concentrators, respectively. The results demonstrate that the standard deviations of the phase angle differences have significantly decreased to 0.1$^{\circ }$ order with the adoption of the proposed method.

42 ENGINEERING↗

Data-Driven PMU Noise Emulation Framework using Gradient-Penalty-Based Wasserstein GAN

Availability of phasor measurement unit (PMUs) data has led to research on data-driven algorithms for event monitoring, control and ensuring stability of the grid. Unavailability of infrequent critical event field PMU data with component failures is driving the need to generate realistic synthetic PMU data for research. The synthetic data from power system simulation software often neglect noise profiles of received phasors, thus creating some discrepancies between real PMU data and synthetic ones. To address this issue, this work presents an initial study on the noise characteristics of PMUs, as well as presenting models for recreating their unique noise signatures. The proposed method, utilizing the Wasserstein generative adversarial network with gradient penalty (WGAN-GP) architecture, provides an excellent benchmark for matching the noise distribution. One can use a well-learned GAN model to draw noise signatures from a distribution that seemingly mirrors the real PMU noise distribution, while also being able to be detached from the PMU data once the training is done. Based on the observed results and employed data-driven methodology, it is expected that the proposed methods can be adapted to replicate the behavior of other sensors, providing research and other applications with a tool for data synthesis and sensor characterization.

PMU↗

Changes Required in the PMU standards

The Phasor Measurement Unit (PMU) is a representational measuring instrument that gives time-stamped measurements of the power system on the assumption that the measurand can be represented as sinusoidal. However, two standards defining the measured quantities unnecessarily corrupt the results and limit the capabilities of the PMU, and are beginning to tax communications systems. This paper examines the two mistakes in the PMU standards, and proposes a solution.

PMU measurement, phase, phasor, measurement theory↗

Improving the PMU Standard

The Phasor Measurement Unit (PMU) is perhaps the first representational measurement widely dispersed in the electric power system. Its usefulness has been demonstrated on many occasions. It is shown in this paper that the excellent performance of the PMU is a tribute to PMU makers, and not attributable to the standards that are supposed to specify the performance. The IEEE and IEC standards illustrate, by means of a “reference model,” how a PMU can be made. Both standards base the model on two fundamental conceptual errors. Without these errors several improvements in performance could be made. The standards should be revised to remove the restrictive “guidance” that the reference model presently offers, and to correct the text so that the appropriate concepts are presented.

Phasor Measurement, reference model↗

Recent Development of Frequency Estimation Methods for Future Smart Grid

The frequency estimated by the Phasor Measurement Unit (PMU) is a critical index of power system status and supports many smart grid applications. The future smart grid features high penetration of renewables and more fast-moving power electronics inverters but raises challenges to the reliable frequency estimation. This article presents three methods to address these challenges. First, an enhanced zero-crossing algorithm was developed to track the fast-changing frequency in system dynamics. Second, we propose a technology that can tolerate the system transient and suppress the outliers. Third, an algorithm was developed to export high time-resolution frequency estimations with minimum computational effort. All of the proposed methods are realized in hardware and compared with classical frequency estimation methods. The testing results indicate that the proposed methods have excellent performance. They can be used in future PMUs and provide reliable and high time resolution data for smart grid applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CyDER: A Cyber Physical Co-simulation Platform for Distributed Energy Resources in Smartgrids

The CyDER project aimed at developing an open-source, modular and scalable co-simulation platform for power grids with large shares of Distributed Energy Resources (DERs). The project partners are the Lawrence Berkeley National Lab (LBNL), Lawrence Livermore National Lab (LLNL), PG&E, SolarCity, and ChargePoint. The prime recipient is LBNL; SolarCity and ChargePoint were partners for the project’s first two years. Increased DER integration introduces a number of challenges in power grid operation including a more dynamic interaction between the transmission grid and distribution grids, and increased modeling complexity. Although specialized software exists to precisely model different components of the power system, it is far from trivial to integrate all various models and perform a holistic simulation. Instead of replicating all models in a common simulation program, a commonly accepted approach to tackle this model diversity is to couple third-party simulators and models through a co-simulation platform that coordinates information exchange among the various components. Following this line of research, this project’s objective was to develop a co-simulation platform based on a widely accepted industrial standard called Functional Mockup Interface (FMI). Within this process, the project developed models compliant with the FMI standard, called Functional Mockup Units (FMUs), and used them to perform various operational and planning power system analyses. Relying and building upon an industrial standard is the main differentiation of this project compared with previous or parallel efforts in the co-simulation area. Particular emphasis was put on delivering software utilities to facilitate setting up and running co-simulations by end-users. Furthermore, a strong aspect of this project is demonstrating that co-simulation techniques can be used to perform Hardware-in-the-Loop (HIL) simulations that couple software components (e.g., simulated models) with hardware components (e.g., real devices such PV systems and batteries). The long-term goal of CyDER project is to help establish FMI as a powerful standard for co-simulation and promote adoption by electric utilities and other interested stakeholders. The main accomplishments of the project include the development of several FMUs including distribution and transmission grid models, PV inverters with Volt/Var/Watt controllers, batteries, and predictive optimal controllers. Additionally, a unique software package was developed, called SimulatorToFMU, which is capable of exporting any Python-driven simulator or Python script as an FMU. This is an important contribution towards establishing FMI as one of the main co-simulation standards, because more and more third-party programs for sub-system modeling and simulation are delivered with Python APIs. The CyDER platform was used to perform PV hosting capacity analyses in real utility feeders with and without smart inverter controls, battery storage, and EV charging. Smart inverter controls include conventional Volt/Var/Watt controls for reactive power support and active power curtailment, but also predictive controls that optimize the charging and discharging profile of the battery connected on the DC side in order to minimize the customer’s economic benefit. Finally, an important result of this project is delivering an experimental setup that consists of residential-scale PV inverters with battery storage, a real-time grid simulator with an ideal voltage source as grid emulator, and micro Phasor Measurement Units (PMUs). All these components and additional software modules are coupled to one another using the FMI standard and can be co-simulated with the CyDER platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Artificial Intelligence and Machine Learning Applications in Modern Power Systems

Machine learning (ML) and artificial intelligence (AI) algorithms offer valuable tools for the analysis and interpretation of large datasets. These tools have the capability to uncover insights that may not be readily apparent within these datasets. In recent years, the integration of ML and AI has become increasingly prevalent in various applications within the power system domain. One of the earliest instances of machine learning in power systems can be traced back to demand forecasting, where artificial neural networks were employed for short-term load forecasting. In contemporary power systems, an abundance of high-resolution geospatial and temporal data is generated at various time intervals, ranging from sub-seconds (Phasor Measurement Units or PMUs) to seconds (Supervisory Control and Data Acquisition or SCADA), minutes (Process Information or PI), and extending to days, months, and years. These datasets contain valuable information concerning system reliability and performance. This information holds the potential to offer critical insights into system operations, as well as solutions for predicting and mitigating contingencies to prevent cascading outages. Despite the immense power of machine learning tools, system operators, planners, and utilities often exhibit hesitancy in fully embracing AI-enabled system operations and planning. This cautious approach persists, even as numerous diverse applications of machine learning continue to emerge in the realm of power systems. In this chapter, our focus will delve deep into ML and AI applications tailored for power systems. These applications aim to furnish system operators with enhanced situational awareness and augment their decision-making capabilities, especially during challenging operating conditions. Specific areas of interest encompass root cause analyses of electricity market datasets and the strategic selection of representative samples from vast power system databases for training ML/AI models. Finally, the chapter will conclude with a short discussion on the future of ML/AI in power systems and possible directions that the industry is moving towards.

power system applications, machine learning (ML), ↗

Impacts of swinging door lossy compression of synchrophasor data

As the number of operational Phasor Measurement Units (PMUs) is increasing, compression is becoming crucial for efficiently transferring and storing enormous amount of synchrophasor data continuously measured from a power system. Some utilities in the U.S. have already adopted a nonlinear compression technique, called Swinging Door Algorithm (SDA), assuming compressed data meets technical and regulatory requirements without resulting in any degradation of the measurements. This paper studies impacts of this compression algorithm on field measured and simulated PMU data, and presents results from spectral analyses of raw and decompressed measurements. The results show blind application of the SDA compression alters frequency content in the measurements and introduces false harmonics and aliasing. These can lead to false conclusions being drawn from the measurements about the power system condition.

42 ENGINEERING↗

Low cost, flexible, and distribution level universal grid analyser platform: designs and implementations

This study presents the designs and implementations of a distribution level open-universal grid analyser (Open-UGA) platform. The proposed Open-UGA platform consists of distribution-level phasor measurement units (PMUs), a standard signal generator, a router, and a server. Firstly, an overall introduction for the software, hardware, and server architectures of the Open-UGA platform is given. To give a detailed design, the software, hardware, server block diagrams, flowcharts, and printed circuit board photo of the Open-UGA platform are presented in detail. Then, four different types of distribution level PMU algorithms are introduced and implemented in the Open-UGA platform to verify the flexibility and reconfigurability. The flowcharts and functionalities of these four UGAs with different PMU algorithms are given as example implementations. Lastly, a performance comparison is conducted with both quantitative and illustrative results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-driven Cyberattack Detection for Photovoltaic (PV) Systems through Analyzing Micro-PMU Data

With increasing exposure to software-based sensing and control, Photovoltaic (PV) systems are facing higher risks of cyber attacks. Here, to ensure the system stability and minimize potential economic losses, it is imperative to monitor operating states and detect attacks at the early stage. To meet this demand, Micro-Phasor Measurement Units (μPMU) are increasingly popular in monitoring distribution networks. However, due to the relatively low sampling rate, μPMU has not yet been used to detect and classify cyber-attacks in power electronics enabled smart grid. To our knowledge, this is one of the first attempts to use μPMU to detect cyber attacks that degrade the performance of power electronics systems. We propose to apply data-driven methods on micro-PMU data to implement attack detection. We have evaluated data-driven methods, including decision tree (DT), K-nearest neighbor (KNN), support vector machine (SVM), artificial neural network (ANN), long short-term memory (LSTM) and convolutional neural network (CNN). The proposed CNN model achieves the required performances with the highest 99.23% accuracy and 0.9963 F 1 score.

14 SOLAR ENERGY↗

Optimization-Based Data-Driven Approach for Detecting Fault Location in Power Systems

In grids with large penetration of converterinterfaced resources (CIRs), measurements of voltage, current, and line parameters can fluctuate significantly during fault conditions. These fluctuations, combined with complex network topologies and extensive system branching, make accurate fault location challenging. Faults, such as short circuits, can cause prolonged outages with serious socio-economic impacts, highlighting the need for rapid fault identification to minimize downtime. However, current fault detection methods—such as relays and digital fault recorders—often relay information too slowly, impeding swift corrective action. Given the limited availability of high-resolution phasor measurement units, this paper introduces an optimization-based observer to estimate fault locations, grid line parameters, and voltages using local CIR measurements. To preserve the confidentiality of CIRs and enhance estimation accuracy, this study uses a black-box model of CIRs. This bottom-up, event-driven approach can enhances protection and control systems through optimized and real-time fault detection. Simulation results show that the optimization-based data-driven observer can accurately detect fault locations and estimate grid states and parameters, providing valuable insights for utilities and operators in grid applications.

Subedi, Sunil [ORNL] (ORCID:000000034069090X)↗

A Proactive Stochastic Framework for Cyber-Physical Power Systems Security

This paper presents a framework for cyberphysical power systems security in which defensive action is proactive, striving to mitigate the harm from strategic cyber attacks before they occur. The prospect is formulated in a previously-studied context of state estimation via the Kalman filter under false data injection attacks. Assuming a cognitive attacker who is both advanced and persistent, the proactive defense rests upon stochastically influencing the sensors, Phasor Measurement Units, such that subsequent falsification attacks are countered. Examples are crafted to illustrate both the efficacy of the proactive approach in ideal situations and the practical challenges implied by non-ideal situations.

El Mezyani, Touria↗

Dynamic Power Network State Estimation with Asynchronous Measurements

The operation of distribution networks is becoming increasingly volatile, due to fast variations of renewables and, hence, net-loading conditions. To perform a reliable state estimation under these conditions, this paper considers the case where measurements from meters, phasor measurement units, and distributed energy resources are collected and processed in real time to produce estimates of the state at a fast time scale. Streams of measurements collected in real time and at heterogenous rates render the underlying processing asynchronous, and poses severe strains on workhorse state estimation algorithms. In this work, a real-time state estimation algorithm is proposed, where data are processed on the fly. Starting from a regularized least-squares model, and leveraging appropriate linear models, the proposed scheme boils down to a linear dynamical system where the state is updated based on the previous estimate and on the measurement gathered from a few available sensors. The estimation error is shown to be always bounded under mild condition. Numerical simulations are provided to corroborate the analytical findings.

24 POWER TRANSMISSION AND DISTRIBUTION↗