Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “phasor measurement unit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Online Detection of Power Grid Anomalies via Federated Learning

Data from sensors is critical for advanced applica- tions that support efficient, reliable, and resilient electric grid operations. Historically, data from phasor measurement units (PMU) has been utilized to develop a wide variety of wide area control and protection applications suitable for power grid control centers. However, until now, most of these could not be deployed for automated operations due to a set of data corruption challenges and uncertainty in the incoming data pipeline. In this paper, we address the problem of detecting different variety of anomalies that are evident in different high- speed power grid measurements. The paper discusses a workflow for handling problems with data acquisition and highlights some of the key findings suitable for anomaly detection in a centralized and distributed environment. The effectiveness of the proposed method was demonstrated with results utilizing realistic PMU datasets

Shinkle, Matthew W.↗

PMU Data Quality and Sensor Health Monitoring

Phasor Measurement Units (PMUs) play a critical role in the evolution of the electric power industry by providing high-precision, real-time monitoring of essential power system metrics. However, effectively detecting abnormalities and critical events from PMU data is a complex task, complicated by intricate temporal patterns, a scarcity of labeled data for training algo- rithms, and constraints on online computational power. In this study, we apply TranAD, an innovative algorithm that combines transformer architectures with the refinement of adversarial learning, to both synthetic and real-world PMU datasets for developing a data quality and sensor online health monitoring platform for utilities. Our findings reveal that TranAD not only provides efficient detection and localization but also enhances the detail with which abnormalities are detected, marking a a significant step forward in the field of clean data acquisition processes for power system monitoring

deep neural network, machine learning (ML)↗

Model Agnostic Bayesian Framework for Online Anomaly/Event Detection in PMU Data

Phasor measurement units (PMU) are integral to the modernization and automation plan of the electric power industry. A PMU data signature contains system-level events (e.g., faults, generation/load change, etc.) and any measurement/device-related errors. Therefore, the reliable and resilient operation of power systems is equivalent to the quality of the PMU data and the situation awareness provided by its data signature. Despite recent progress, current state-of-the-art methods are not fool-proof and have certain limitations tracing an error/abnormality to sensor sub-components and grid systems. This is because of technical challenges imposed by the scarcity of the labeled information, loss of data quality, and non-stationarity of data. In this paper, we consider the online PMU data stream as an output of a stochastic process and pose the anomaly/event detection as a changepoint detection problem dealing with detecting parameter changes in the underlying stochastic processes. The proposed model-agnostic framework relies on: (a) feature extraction utilizing the minimum volume enclosing ellipsoids (MVEE) method from raw PMU observations and (b) a Bayesian framework of changepoint detection. The validity of the proposed methodology is discussed through numerical experiments on real-world utility-scale PMU data.

Hossain, Ramij Raja↗

Online Output-Based Inertia Estimation of Modern Power Systems

The overall inertia of modern power systems is drastically impacted by the penetration level of converter-based resources (CBRs). The intermittent output of CBRs and their dependence on the weather conditions affirm the need for a realtime inertia estimation approach. This can help the transmission system operators(TSOs) to be continuously aware of the changes in the system inertia and to take suitable control actions. This paper is a step forward to a totally data-driven framework for power system inertia estimation using the available measurements from the phasor measurement units (PMUs). This inertia estimation is done based on the spectral analysis of the so-called Koopman linear operator. Koopman operator considers the relationship between the system's inertia and its dynamical response to slight disturbances in the load. Simulation results show that Koopman operator can approximate the system behavior in a reconstructed linear space hence inertia constant is estimated accurately.

data-driven↗

A Practical On-line Framework for a Modified Energy Detector by Whitening Ambient PMU Data

A key application of Phasor Measurement Units (PMUs) is power system oscillation detection. An energy detector is a straightforward detection method, but setting thresholds requires extensive and time consuming baselining of data. This paper proposes a novel on-line method of whitening PMU measurements supporting a framework for detecting forced oscillations without requiring extensive baselining. An example of 24 hours of actual PMU data illustrates how a forced oscillation is very visible in the energy signal of the whitened data, while being hard to detect in the colored ambient noise. With this framework, the statistical theory for setting thresholds without baselining is much more straightforward and is the focus of future work.

Xu, Zikai↗

Applying Utility's Advanced Grid Technologies to Improve Resiliency of a Critical Load

The US DOE Office of Electricity's Energy Storage Program's joint R&D work with the Cordova Electric Cooperative (CEC) has deployed several advanced grid technologies that are providing benefits today to Cordova Alaska's electricity users. Advanced grid technologies deployed through DoE co-funded R&D include a 1MW Battery Energy Storage System (BESS), and enhanced monitoring including Phasor Measurement Units (PMU's) to help better understand the operational impacts of the added BESS. This paper will highlight key accomplishments to-date in deploying and using advanced grid technologies, and then outline the next phase of work that will use these technologies to implement an operating scheme to reconfigure the utility's distribution system and utility resources including BESS to provide emergency back-up power to a critical load: the Cordova Community Medical Center (CCMC). This paper will include additional insights on the use of utility resources to support critical loads via case study examples by the National Rural Electric Cooperative Assoc. (NRECA).

BESS↗

Novel Data Driven Noise Emulation Framework using Deep Neural Network for Generating Synthetic PMU Measurements

Sensors play a critical role in supporting day-to-day grid operations and they are essential to operator’s decision-making process. Furthermore, sensors and sensor behaviors need to be emulated with grid simulations to perform modeling studies and to design cutting edge power systems applications. Ensuring the accurate behavior of these applications requires accurate emulation of sensors and pertinent signals. However, most grid simulators and modeling tools assume either zero error scenarios or simplistic noise models that may not always correlate to real-world sensors. To address the above issue, this work presents an initial study on the noise characteristics of phasor measurement units (PMUs), along with models for recreating their unique noise signatures. The proposed methods (both analytical and machine-learning-based) provide a substantial increase in a sensor’s model fidelity, a feature that can be leveraged by an end-user application to yield more accurate system representations. The proposed methods were then applied to micro PMU data from the EPFL microgrid campus to extract sensor noise profiles. This data was used to train a deep learning model, which was tested to emulate the noise characteristics present in actual signals. Based on the observed results and the employed data-driven methodology, the proposed methods may be adapted to replicate the behavior of other grid sensors and power new applications capable of detecting sensor degradation and eventual device failures in near real-time.

PMU, noise emulation, synthetic measurements, deep↗

Open Source Synergy: Developing and Validating PMU Data Analysis Techniques Using Open Source Tools and Datasets

This paper presents an exploration into the development and validation of data analysis approaches for Phasor Measurement Units (PMUs) using open-source datasets and tools. Various methods for event detection, event classification, frequency response, and oscillation analysis were tested. We leverage the capabilities of Archive Walker (AW), the Frequency Response Analysis Tool (FRAT), and the Oscillation Baselining and Analysis Tool (OBAT), all open-source tools, for efficient processing and analysis of synchrophasor data. The open-source Transmission Signature Library (TSL) dataset was employed as a dataset for a comprehensive evaluation to assess the performance and reliability of the proposed methods.

PMU, event analysis, oscillation, Frequency Respon↗

Event Detection and Classification Using Machine Learning Applied to PMU Data for the Western US Power System

Smart grid technology enhances our comprehension and reliability of the power grid, leveraging Phasor Measurement Unit (PMU) data—time-synchronized, high-frequency measurements gathered across the US power grid. This paper employs machine learning techniques to effectively analyze the vast PMU data in Wide Area Monitoring Systems (WAMS) for power grid event detection and classification. Analyzing several months of real-world PMU data, the paper focuses on machine learning for fast, precise event detection and classification, corroborated by utility event logs. Practical challenges like feature extraction, dimensionality reduction, and model selection are addressed. A novel feature yielding improved results is discovered, and a supplementary algorithm for detecting small power grid faults is developed. The final algorithm is validated using a month-long real PMU data set, demonstrating its capability in accurately identifying power grid events in near real-time.

machine learning, event detection, PMU↗

Cyber-Power Co-Simulation for End-to-End Synchrophasor Network Analysis and Applications

The resiliency, reliability and security of the next generation cyber-power smart grid depend upon efficiently leveraging advanced communication and computing technologies. Also, developing real-time data-driven applications is critical to enable wide-area monitoring and control of the cyber-power grid given high-resolution data from Phasor Measurement Units (PMUs). North American Synchrophasor Initiative Network (NASPlnet) provides guidance for PMU data exchanges. With the advancement in networking and grid operation, it is necessary to evaluate the performance of different data flow architectures suggested by NASPInet and analyze the impact on applications. Therefore, we need a cyber-power co-simulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents an end-to-end automated and user-driven cyber-power co-simulation using NS3 to model communication networks, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application utilizing PMU data in an IEEE 39 bus test system is presented using this cosimulation testbed.

Mustafa, Hussain M.↗

Coordinated Control of Natural and Sub-Synchronous Oscillations via HVDC Links in Great Britain Power System

Conventional power oscillation damping (POD) controllers have been designed to be effective in damping either inter-area low-frequency oscillations (LFO) or sub-synchronous oscillations (SSO). For those POD controls, model-based control design method has been widely implemented with wide-area feedback signals from phasor measurement units (PMU). However, the model accuracy of a large realistic power system can hardly be guaranteed, which will finally impact the POD damping performance. In this paper, a measurement-based method is proposed for POD design using High Voltage Direct Current links (HVDC) to realize the coordinated control of both LFO and SSO. For each type of oscillations, a band-pass filter is added to avoid the interactions between different modes. Case studies are carried out on the Great Britain 36-bus power system model with multiple HVDC links in DIgSILENT/PowerFactory. Simulation results demonstrate that the proposed PODs are effective in damping inter-area LFO and SSO simultaneously.

Zhao, Yi↗

Synchrophasor Data Anomaly Detection on Grid Edge by 5G Communication and Adjacent Compute

The fifth-generation mobile communication (5G) technology offers the opportunities to enhance the grid real-time monitoring. The 5G-enabled phasor measurement units (PMUs) features flexible positioning and cost-effective long-term maintenance, without constraints of fixing wire. This paper is the first to demonstrate the applicability of 5G in PMU communication, and the experiment was carried out at Verizon non-standalone testbed at Pacific Northwest National Laboratory (PNNL) Advanced Wireless Communication lab. The performance of 5G-enabled PMU communication setup is reviewed and discussed in this paper, and the paper presents a real-time dynamic linear model (DML) based synchrophasor data anomaly detection application. Last but not least, the practicability of implementing 5G for wide-area protection strategies is explored and discussed by analyzing the experimental results.

5G, Synchrophasor data, machine learning, anomaly ↗

Structure-Informed Graph Learning of Networked Dependencies for Online Prediction of Power System Transient Dynamics

Online transient analysis plays an increasingly important role in dynamic power grids as the renewable generation continues growing. Traditional numerical methods for transient analysis not only are computationally intensive but also require precise contingency information as input, and therefore, are not suitable for online applications. Existing online transient assessment studies focus on the determination of post-contingency system stability or stability margin. Here, this paper develops a novel graph-learning framework, Deep-learning Neural Representation or DNR, for online prediction, of the time-series trajectories of the system states using initial system responses that can be measured by phasor measurement units (PMUs). The proposed DNR framework consists of two sequential modules: a Network Constructor that captures network dependencies among generators, and a Dynamics Predictor that predicts the system trajectories. The key to improved prediction performance is the introduction of the spatio-temporal message-passing operations into graph neural networks with structural knowledge. Its effectiveness and scalability are validated through comparative studies, demonstrating the prediction performance under different contingency scenarios for systems of different sizes. This framework provides a solution to online predicting post-fault system dynamics based on real-time PMU measurements. Additionally, it can also be applied to facilitate the offline transient simulation without simulating the entire trajectories.

24 POWER TRANSMISSION AND DISTRIBUTION↗

From Event Data to Wind Power Plant DQ Admittance and Stability Risk Assessment

This paper presents a dynamic event data-based stability risk assessment method for power grids with high penetrations of inverter-based resources (IBRs). This method relies on obtaining the IBRs' DQ admittance through dynamic event data and computing the system's eigenvalues based on the admittance models. Two critical technologies are employed in this research, including time-domain and frequency-domain data fitting and dq-frame voltage and current signal derivation. The first technology is key to obtaining the s-domain expressions from the transient response data, and the s-domain DQ admittance model from the frequency-domain measurements. The second technology is key to obtaining the dq-frame voltage and current signals from either the three-phase instantaneous measurements or the phasor measurement unit (PMU) data. The method is illustrated using data generated from a Type-4 wind power plant modeled in PSCAD. This paper demonstrates the technical feasibility of the proposed approach.

17 WIND ENERGY↗

Bayesian High-Rank Hankel Matrix Completion for Nonlinear Synchrophasor Data Recovery

Phasor measurement units (PMUs) provide high temporal-resolution synchrophasor measurements for power system monitoring and control. The frequent data quality issues, such as missing and bad data, prevent the incorporation of synchrophasor data in real-time operations. Most existing data-driven data recovery methods assume the power system dynamics can be approximated by a linear dynamical system, and the recovery performance degrades significantly when the power system is experiencing nonlinear dynamics during significant events. Here, this paper proposes a data-driven Bayesian nonlinear synchrophasor data recovery method (Ba-NSDR) that can recover a consecutive time period of simultaneous data losses or errors across all channels, even when the underlying system is highly nonlinear. The idea is to lift the Hankel matrix of the spatial-temporal synchrophasor data to a higher dimension such that the lifted Hankel matrix is low-rank in that space and can be processed with the kernel trick. Our proposed Bayesian method then infers the probabilistic distributions of synchrophasor from the partial observations. Some distinctive features of Ba-NSDR include an uncertainty index to measure the accuracy of the recovery result and the robustness to parameter selections. Our method is verified on both synthetic and recorded event datasets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-Driven Cyber-Attack Detection for PV Farms via Time-Frequency Domain Features

The internetworking of grid-connected power electronics converters (PECs) in photovoltaic (PV) farms has inevitably expanded the cyber-attack surfaces. Here this paper presents a comprehensive study on cyber-attack detection and diagnosis for PEC-enabled PV farms via single waveform sensor to distinguish between normal conditions, open-circuit faults, short-circuit faults, and cyber-attacks. To our knowledge, this has not been attempted before. Firstly, we propose frequency-domain magnitude-based residuals to identify short-circuit faults and a time-domain mean current vector-based feature to distinguish open-circuit faults from other threats. These features can fully reflect the specific physical characteristics of PV farms during threat duration. Secondly, unlike micro phasor measurement units (µPMU) and raw electric waveform-based methods, the proposed innovative features can address novel cyber-attacks that are excluded from the training process. Thirdly, an online hardware-in-the-loop (HIL) testbed using the OPAL-RT real-time digital simulator has verified the effectiveness. The monitoring system runs in real-time while using HIL as an operational solar farm and a National Instruments (NI) data acquisition card as the electric waveform sensor at the point of coupling.

42 ENGINEERING↗

Learning Distribution Grid Topologies: A Tutorial

Unveiling feeder topologies from data is of paramount importance to advance situational awareness and proper utilization of smart resources in power distribution grids. This tutorial summarizes, contrasts, and establishes useful links between recent works on topology identification and detection schemes that have been proposed for power distribution grids. The primary focus is to highlight methods that overcome the limited availability of measurement devices in distribution grids, while enhancing topology estimates using conservation laws of power-flow physics and structural properties of feeders. Grid data from phasor measurement units or smart meters can be collected either passively in the traditional way, or actively, upon actuating grid resources and measuring the feeder's voltage response. Analytical claims on feeder identifiability and detectability are reviewed under disparate meter placement scenarios. Such topology learning claims can be attained exactly or approximately so via algorithmic solutions with various levels of computational complexity, ranging from least-squares fits to convex optimization problems, and from polynomial-time searches over graphs to mixed-integer programs. Although the emphasis is on radial single-phase feeders, extensions to meshed and/or multiphase circuits are sometimes possible and discussed. Here this tutorial aspires to provide researchers and engineers with knowledge of the current state-of-the-art in tractable distribution grid learning and insights into future directions of work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SoDa: An Irradiance-Based Synthetic Solar Data Generation Tool (SoDa) v0.1

SoDa is an irradiance-based synthetic Solar Data generation tool to generate realistic sub-minute solar photovoltaic (PV) power time series, that emulate the weather pattern for a certain geographical location. Our tool relies on the National Solar Radiation Database (NSRDB) to obtain irradiance and weather data patterns for the site. Irradiance is mapped onto a PV model estimate of a solar plant's 30-min power output, based on the configuration of the panel. We use a stochastic model with a switching behavior due to different weather regimes as provided by the cloud type label in the NSRDB, with parameters for the cloudy states trained on the high-resolution solar power measurements from a Phasor Measurement Unit (PMU).

Carreno, IgnacioLosada↗