Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “permanence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Percutaneous Retrieval of Permanent Inferior Vena Cava Filters

PurposeTo evaluate the feasibility, risks, and techniques of percutaneous removal of permanent TrapEase and Simon Nitinol IVC filters.Materials and MethodsBetween August 2011 and August 2015, 12 patients (5 women, 7 men; age range, 26–75 years) underwent an attempt at percutaneous removal of permanent TrapEase (10) and Simon Nitinol (2) IVC filters due to a history of IVC filter complications or need for lifelong anticoagulation due to the filter. Medical records were reviewed for filter dwell time, presence of iliocaval deep venous thrombosis, procedural technique, and complications.ResultsFilter dwell times ranged from 7 days to 15 years (mean 5.1 years). Successful removal of permanent IVC filters was possible in 11 of 12 patients (91.6 %). In 1 patient, a chronically thrombosed IVC filter could not be removed despite laser sheath assistance, but was successfully recanalized with the PowerWire RF guidewire. In the failed retrieval attempt, a stent was placed through the chronically thrombosed IVC filter with restoration of in-line flow. One major complication of large venous groin hematoma was encountered.ConclusionsIn carefully selected patients, percutaneous removal of permanent IVC filters can be performed safely despite prolonged filter dwell times. Extraction of chronically embedded permanent IVC filters may be facilitated by jugular and femoral approaches, often with laser sheath assistance. Chronic filter thrombosis and caval scarring may increase the risk of retrieval failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PM4Stell: A prototype permanent magnet stellarator structure

Permanent magnets provide a possible solution to simplify complicated stellarator coils. Here, a prototype permanent magnet stellarator structure, PM4Stell, has been funded to demonstrate the technical feasibility of using permanent magnets to create the shaping field of a stellarator. Permanent magnets in uniform cubes with three polarization directions will be carefully placed to generate the required magnetic field for a National Compact Stellarator eXperiment-like equilibrium together with planar toroidal field coils. Discrete magnets will be glued together and inserted into a “post-office-box-like” supporting structure. Electromagnetic and structural analyses have been done to validate the design. Error field correction magnets will be used to shim possible error fields. The design efforts of the prototype permanent magnet stellarator structure are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Topology optimization of permanent magnets for stellarators

In this work, we introduce a topology optimization method to design permanent magnets for advanced stellarators. Recent researches show that permanent magnets have great potentials to simplify stellarator coils. We adopt state-of-the-art numerical techniques to determine the presence of magnets in the entire designing space. The FAMUS code is developed and it can design engineering-feasible permanent magnets for general stellarators satisfying the constraints of the maximum material magnetization and explicit forbidden regions. FAMUS has been successfully verified against the previously proposed linear method. Three different permanent magnet designs together with planar TF coils for a half-Tesla NCSX configuration have been obtained for demonstrations. The designs have good accuracy in generating the desired equilibrium and offer considerably large plasma access on the outboard side. The results show that FAMUS is a flexible, advanced numerical tool for future permanent magnet stellarator designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NdFeB Permanent Magnet Uses, Projected Growth Rates and Nd Plus Dy Demands across End-Use Sectors through 2050: A Review

Rare earth element (REE) permanent magnets (NdFeB) are a critical element in a vast and growing number of industrial applications. In consumer electronics, a broad category encompassing computer, CD, and DVD hard drives, in addition to the ubiquitous cell phones, the nominal NdFeB magnet content may be small, but the global market share for this sector accounts for almost 30% of NdFeB demand, due to a large and continually increasing consumer base. It is estimated that wind turbines that primarily employ permanent magnets will add roughly 110 GW annually of on- and off-shore capability over the next few years. Electric vehicles (EVs) and E-bicycles (EBs) equipped with permanent magnet motors comprise the transportation contribution. Permanent magnet motors have garnered nearly 100% of the market share among EV manufacturers worldwide. Industrial, professional service, and personal robots, most using permanent magnets, are also included in the projected global need for rare earths, particularly Nd and Dy. The sector projects significant growth of approximately 10% across robotic categories. In this paper, we calculate the future demand for Nd and Dy through 2050 across these sectors using a compounded annual growth rate coupled with magnet weight and rare earth content. Uncertainties in the estimates, such as the true global production of Nd, a range of end-product scales and/or unit types in each sector, varied magnet compositions, and the variety of uses within a sector, are all considered.

Geochemistry & Geophysics↗

Permanent-File-Validation Utility Computer Program

Errors in files detected and corrected during operation. Permanent File Validation (PFVAL) utility computer program provides CDC CYBER NOS sites with mechanism to verify integrity of permanent file base. Locates and identifies permanent file errors in Mass Storage Table (MST) and Track Reservation Table (TRT), in permanent file catalog entries (PFC's) in permit sectors, and in disk sector linkage. All detected errors written to listing file and system and job day files. Program operates by reading system tables , catalog track, permit sectors, and disk linkage bytes to vaidate expected and actual file linkages. Used extensively to identify and locate errors in permanent files and enable online correction, reducing computer-system downtime.

Derry, Stephen D.↗

Toroidal-Core Microinductors Biased by Permanent Magnets

The designs of microscopic toroidal-core inductors in integrated circuits of DC-to-DC voltage converters would be modified, according to a proposal, by filling the gaps in the cores with permanent magnets that would apply bias fluxes (see figure). The magnitudes and polarities of the bias fluxes would be tailored to counteract the DC fluxes generated by the DC components of the currents in the inductor windings, such that it would be possible to either reduce the sizes of the cores or increase the AC components of the currents in the cores without incurring adverse effects. Reducing the sizes of the cores could save significant amounts of space on integrated circuits because relative to other integrated-circuit components, microinductors occupy large areas - of the order of a square millimeter each. An important consideration in the design of such an inductor is preventing magnetic saturation of the core at current levels up to the maximum anticipated operating current. The requirement to prevent saturation, as well as other requirements and constraints upon the design of the core are expressed by several equations based on the traditional magnetic-circuit approximation. The equations involve the core and gap dimensions and the magnetic-property parameters of the core and magnet materials. The equations show that, other things remaining equal, as the maximum current is increased, one must increase the size of the core to prevent the flux density from rising to the saturation level. By using a permanent bias flux to oppose the flux generated by the DC component of the current, one would reduce the net DC component of flux in the core, making it possible to reduce the core size needed to prevent the total flux density (sum of DC and AC components) from rising to the saturation level. Alternatively, one could take advantage of the reduction of the net DC component of flux by increasing the allowable AC component of flux and the corresponding AC component of current. In either case, permanent-magnet material and the slant (if any) and thickness of the gap must be chosen according to the equations to obtain the required bias flux. In modifying the design of the inductor, one must ensure that the inductance is not altered. The simplest way to preserve the original value of inductance would be to leave the gap dimensions unchanged and fill the gap with a permanent- magnet material that, fortuitously, would produce just the required bias flux. A more generally applicable alternative would be to partly fill either the original gap or a slightly enlarged gap with a suitable permanent-magnet material (thereby leaving a small residual gap) so that the reluctance of the resulting magnetic circuit would yield the desired inductance.

Lieneweg, Udo↗

High-gradient permanent magnet apparatus and its use in particle collection

A high-gradient permanent magnet apparatus for capturing paramagnetic particles, the apparatus comprising: (i) at least two permanent magnets positioned with like poles facing each other; (ii) a ferromagnetic spacer separating the like poles; and (iii) a magnetizable porous filling material in close proximity to the at least two permanent magnets. Also described is a method for capturing paramagnetic particles in which a gas or liquid sample containing the paramagnetic particles is contacted with the high-gradient permanent magnet apparatus described above; wherein, during the contacting step, the gas or liquid sample contacts the magnetizable porous filling material of the high-gradient permanent magnet apparatus, and at least a portion of the paramagnetic particles in the gas or liquid sample is captured on the magnetizable porous filling material.

47 OTHER INSTRUMENTATION↗

Additive manufacturing of permanent magnets

Permanent magnets are an essential technology for energy conversion. Motors and generators are used to convert energy between electrical and mechanical forms. Permanent magnets must be pre-charged (magnetized) prior to their use in an application and must maintain this magnetization during operation. In addition, permanent magnets must generate sufficient magnetic flux for a given application. Nevertheless, permanent magnets can be demagnetized by a number of circumstances, including the presence of other magnetic materials in their service, temperature changes (thermal demagnetization), microstructural degradation, and even the magnet’s own internal demagnetizing field. Therefore, the performance of a permanent magnet can be best understood by examining its ability to withstand demagnetization and to supply the magnetic flux required in a given application. Some of these properties are discussed further. Additive manufacturing, followed by exchange spring magnets will be discussed later.

42 ENGINEERING↗

Modeling of hydrogen liquefaction using magnetocaloric cycles with permanent magnets

Hydrogen (H 2 ) is promising alternative to replace fossil fuels, but its transport and storage has been challenging. As H 2 fuel cell vehicles are gaining traction, the infrastructure for storing large amounts of liquid H 2 is needed. However, liquid H 2 would suffer from boil-off loss, and traditional vapor compression refrigeration systems would not be able to economically recover the lost H 2 due to the low efficiencies at cryogenic temperature. Magnetocaloric (MC) refrigeration systems could possess much higher coefficient of performance (COP) at cryogenic temperature compared to the vapor compression ones. Previous work on cryogenic MC systems, however, have only focused on large scale applications which use superconducting magnets to provide a large magnetic field but are prohibitively expensive to operate for small scale applications, such as that of a H 2 refilling station. In this work, we model the performance of a MC refrigeration cycle using 1-Tesla permanent magnets for H 2 liquefaction, with the objective of cooling H 2 from 80 K (using liquid nitrogen as the heat sink) to 20 K (boiling point of hydrogen). We evaluate main performance metrics including the total work input to the refrigeration system, COP, total MCM mass in the system, and total volume of the permanent magnets, etc. Our modeling results indicate that such a permanent magnet-based MC cooling system is feasible for small-scale H 2 liquefaction, with projected COP values significantly higher than those of vapor compression systems. In conclusion, this work provides design guidelines for future experimental efforts on permanent magnet MC cooling systems for cryogenic cooling.

08 HYDROGEN↗

Permanent magnet with MgB{sub 2} bulk superconductor

Superconductors with persistent zero-resistance currents serve as permanent magnets for high-field applications requiring a strong and stable magnetic field, such as magnetic resonance imaging. The recent global helium shortage has quickened research into high-temperature superconductors (HTSs)—materials that can be used without conventional liquid-helium cooling to 4.2 K. Herein, we demonstrate that 40-K-class metallic HTS magnesium diboride (MgB{sub 2}) makes an excellent permanent bulk magnet, maintaining 3 T at 20 K for 1 week with an extremely high stability (<0.1 ppm/h). The magnetic field trapped in this magnet is uniformly distributed, as for single-crystalline neodymium-iron-boron. Magnetic hysteresis loop of the MgB{sub 2} permanent bulk magnet was determined. Because MgB{sub 2} is a simple-binary-line compound that does not contain rare-earth metals, polycrystalline bulk material can be industrially fabricated at low cost and with high yield to serve as strong magnets that are compatible with conventional compact cryocoolers, making MgB{sub 2} bulks promising for the next generation of Tesla-class permanent-magnet applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nonuniform radiation damage in permanent magnet quadrupoles

We present data that indicate nonuniform magnetization loss due to radiation damage in neodymium-iron-boron Halbach-style permanent magnet quadrupoles. The proton radiography (pRad) facility at Los Alamos uses permanent-magnet quadrupoles for magnifying lenses, and a system recently commissioned at GSI-Darmsdadt uses permanent magnets for its primary lenses. Large fluences of spallation neutrons can be produced in close proximity to these magnets when the proton beam is, intentionally or unintentionally, directed into the tungsten beam collimators; imaging experiments at LANL’s pRad have shown image degradation with these magnetic lenses at proton beam doses lower than those expected to cause damage through radiation-induced reduction of the quadrupole strength alone. We have observed preferential degradation in portions of the permanent magnet quadrupole where the field intensity is highest, resulting in increased high-order multipole components.

36 MATERIALS SCIENCE↗

A novel scheme for error field correction in permanent magnet stellarators

Stellarators offer a promising path towards fusion reactors, but their design and construction are complicated by stringent tolerance requirements on highly complex 3D coils. A potential way to simplify the engineering requirements for stellarators is to use simple planar toroidal field coils along with permanent magnet arrays to generate shaping fields. In order to ensure sufficient field accuracy while minimizing engineering complexity and system cost, new techniques are required to correct the field produced by the permanent magnet arrays to within requirements set by plasma physics. This work describes a novel correction method developed for this purpose. This analysis is applied to the design of a quasi-axisymmetric stellarator that employs a combination of permanent magnets and planar toroidal field coils to generate its magnetic field. Analysis techniques and initial results using the method for error correction on a proposed permanent magnet stellarator are shown, and it is demonstrated that the method successfully meets the design requirements of the project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Light Metals Permanent Mold Casting

Current vehicles use mostly ferrous components for structural applications. It is possible to reduce the weight of the vehicle by substituting these parts with those made from light metals such as aluminum and magnesium. Many alloys and manufacturing processes can be used to produce these light metal components and casting is known to be most economical. One of the high integrity casting processes is permanent mold casting which is the focus of this research report. Many aluminum alloy castings used in automotive applications are produced by the sand casting process. Also, aluminum-silicon (Al-Si) alloys are the most widely used alloy systems for automotive applications. It is possible that by using high strength aluminum alloys based on an aluminum-copper (Al-Cu) system and permanent mold casting, the performance of these components can be enhanced significantly. This will also help to further reduce the weight. However, many technological obstacles need to be overcome before using these alloys in automotive applications in an economical way. There is very limited information in the open literature on gravity and low-pressure permanent mold casting of high strength aluminum alloys. This report summarizes the results and issues encountered during the casting trials of high strength aluminum alloy 206.0 (Al-Cu alloy) and moderate strength alloy 535.0 (Al-Mg alloy). Five engineering components were cast by gravity tilt-pour or low pressure permanent mold casting processes at CanmetMATERIALS (CMAT) and two production foundries. The results of the casting trials show that high integrity engineering components can be produced successfully from both alloys if specific processing parameters are used. It was shown that a combination of melt processing and mold temperature is necessary for the elimination of hot tears in both alloys.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stability of the Early Mars Atmosphere to Collapse into Permanent Polarcaps

The presence of a permanent CO2 polar ice cap on Mars has important consequences for the planet's climate system. The heat balance of such a cap, which is determined mainly by atmospheric heat transport, and the downward solar in infrared radiative fluxes, determines its surface temperature, which through the vapor pressure relation sets the mean annual surface pressure. On Mars today, for example, the south residual CO2 cap is present year-round with a mean annual temperature of approximately 145 K which corresponds to a mean annual CO2 vapor pressure of approximately 600 Pa. On early Mars, permanent polar caps are also possible especially since the sun was less luminous 3.5-4.0 Gya. Thus, the existence of permanent polar caps on early Mars is central to understanding the nature of the planets climate system in those ancient times and whether or not the atmosphere might have been capable of sustaining conditions suitable for liquid water flowing over the surface as is indicated in the geological record. Forget et al [1] showed that for present orbital properties atmospheric collapse into permanent polar caps could only be prevented for surface pressures roughly between 500 - 3000 hPa. Though follow-on studies confirm and extend the Forget et al. results [2], the full sensitivity of this "window" of stability has not been explored. There are many factors to consider such the albedo of the caps, dust content of the atmosphere, and the presence of water ice clouds. However, we begin our exploration of the stability of the early Martian atmosphere by focusing on the role of CO2 ice clouds. In some preliminary simulations with the Ames Mars General Circulation Model (GCM) we found that atmospheric collapse depends on assumptions regarding the fate of CO2 ice clouds. If, for example, we assume the clouds immediately fall to the surface, then in some cases collapse is favored. On the other hand if the clouds are allowed to fall and evaporate, collapse can be averted. This implies that CO2 ice cloud microphysics is important to the overall stability of the atmosphere. Though the Ames GCM has a sophisticated CO2 cloud microphysics package that includes nucleation, growth, and sedimentation (see accompanying poster by Kahre et al. [3]), we have implemented a simpler scheme based on the Forget et al. [1] approach to CO2 ice clouds. Our goal is to reproduce and expand their study. The key parameter in this approach is the concentration and vertical distribution of cloud condensation nuclei (CCN), i.e., dust particles. Fewer CCN lead to larger particles which fall faster, while higher CCN concentrations lead to smaller particles and thicker clouds that remain suspended for longer periods of time. We plan to explore the stability of the atmosphere to CCN concentrations and distributions and then assess the capability of thick early atmospheres to loft and distribute dust particles (CCN) around the planet. Thus, our work will shed light on the nature of the coupling between the dust and CO2 cycles and the implications it has for the early Mars climate system.

ice cap↗

Use of Retrievable Compared to Permanent Inferior Vena Cava Filters: A Single-Institution Experience

The purpose of this study was to review the use, safety, and efficacy of retrievable inferior vena cava (IVC) filters in their first 5 years of availability at our institution. Comparison was made with permanent filters placed in the same period. A retrospective review of IVC filter implantations was performed from September, 1999, to September, 2004, in our department. These included both retrievable and permanent filters. The Recovery nitinol and Guenther tulip filters were used as retrievable filters. The frequency of retrievable filter used was calculated. Clinical data and technical data related to filter placement were reviewed. Outcomes, including pulmonary embolism, complications associated with placement, retrieval, or indwelling, were calculated. During the study period, 604 IVC filters were placed. Of these, 97 retrievable filters (16%) were placed in 96 patients. There were 53 Recovery filter and 44 Tulip filter insertions. Subjects were 59 women and 37 men; the mean age was 52 years, with a range of from 18 to 97 years. The placement of retrievable filters increased from 2% in year 1 to 32% in year 5 of the study period. The total implantation time for the permanent group was 145,450 days, with an average of 288 days (range, 33-1811 days). For the retrievable group, the total implantation time was 21,671 days, with an average of 226 days (range, 2-1217 days). Of 29 patients who returned for filter retrieval, the filter was successfully removed in 28. There were 14 of 14 successful Tulip filter retrievals and 14 of 15 successful Recovery filter retrievals. In one patient, after an indwelling period of 39 days, a Recovery nitinol filter could not be removed secondary to a large clot burden within the filter. For the filters that were removed, the mean dwell time was 50 days for the Tulip type and 20 days for the Recovery type. Over the follow-up period there was an overall PE incidence of 1.4% for the permanent group and 1% for the retrieval group. In conclusion, there was an increase in the use of retrievable filters over the study period and an overall increase in the total number of filters implanted. The increased use of these filters appeared to be due to expanded indications predicated by their retrievability. Placement and retrieval of these filters have a low risk of complications, and retrievable filters appeared effective, as there was low rate of clinically significant pulmonary embolism associated with these filters during their indwelling time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospects for Non-Rare Earth Permanent Magnets for Traction Motors and Generators

With the advent of high-flux density permanent magnets based on rare earth elements such as neodymium (Nd) in the 1980s, permanent magnet-based electric machines had a clear performance and cost advantage over induction machines when weight and size were factors such as in hybrid electric vehicles and wind turbines. However, the advantages of the permanent magnet-based electric machines may be overshadowed by supply constraints and high prices of their key constituents, rare earth elements, which have seen nearly a 10-fold increase in price in the last 5 years and the imposition of export limits by the major producing country, China, since 2010. We outline the challenges, prospects, and pitfalls for several potential alloys that could replace Nd-based permanent magnets with more abundant and less strategically important elements.

36 MATERIALS SCIENCE↗

Permanent Planar Iodine-125 Implants: The Dosimetric Effect of Geometric Parameters for Idealized Source Configurations

Purpose: To provide dosimetric information about permanent planar {sup 125}I implants in a manner that is useful to the brachytherapist in the operative setting. Methods and Materials: Reference planar permanent implants were simulated for a variety of areas with sources placed uniformly on a 1-cm grid. Implants having variable source spacing and curvature were simulated and compared with the reference implants. Dosimetric measures were calculated at 0.5 and 1.0 cm from the implant plane. Results: A method for calculating dosimetric statistics for permanent implants ranging from 5 x 5 cm to 13 x 13 cm is presented. A formula to predict the reference source strength needed to achieve a desired dosimetric quantity is also presented. The effect of adjusting strand spacing to compensate for source activity is presented and is shown to be an effective means to adjust implants to use source strengths other than the reference strength. The effect of implant curvature compared with flat implants on dosimetric statistics is presented as a function of radius of curvature. Conclusions: The results presented in this work may be used to provide information about dose delivered from planar permanent implants.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel mechanisms for solid-state processing and grain growth with microstructure alignment in alnico-8 based permanent magnets

An estimated 750,000 new hybrid electric and plug-in battery vehicles, most with permanent magnet synchronous alternating current (PMAC) drive motors, took to the road in 2016 alone. Accompanied by 40% year over year growth in the EV market significant challenges exist in producing large quantities of permanent magnets (on the order of tens of millions) for reliable, low-cost traction motors [IE Agency, Energy Technology Perspectives (2017)]. Since the rare earth permanent magnet (REPM) market is essentially 100% net import reliant in the United States and has proven to have an unstable cost and supply structure in recent years, a replacement RE-free PM material must be designed or selected, fully developed, and implemented. Alnico, with its high saturation magnetization and excellent thermal stability, appears to be uniquely suited for this task. Further, while alnico typically has been considered a relatively low coercivity hard magnet, strides have been made to increase the coercivity to levels suitable for traction drive motors [W Tang, IEEE Trans. Magn., 51 (2015)]. If a simple non-cast approach for achieving near [001] easy axis grain aligned permanent magnets can be found, this would allow massproduced final-shape anisotropic high energy product magnets suitable for usage in compact high RPM rotor designs. Therefore, a powder metallurgical approach is being explored that uses classic compression molding with “de-bind and sinter” methods, where a novel applied uniaxial loading, and an applied magnetic field may create final-shape magnets with highly textured resulting microstructures by two different mechanisms. Results indicate a positive correlation between applied uniaxial load and resulting texture (Fig. 1), along with benefits from using an applied magnetic field for improved texture, as well. Lastly, the apparent mechanisms and resulting properties will be described using closed loop hysteresisgraph measurements, EBSD orientation mapping, and high-resolution SEM.

42 ENGINEERING↗