Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance tuning programming systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

MatRIS: Multi-level Math Library Abstraction for Heterogeneity and Performance Portability using IRIS Runtime

Vendor libraries are tuned for a specific architecture and are not portable to others. Moreover, they lack support for heterogeneity and multi-device orchestration, which is required for efficient use of contemporary HPC and cloud resources. To address these challenges, we introduce MatRIS—a multilevel math library abstraction for scalable and performance-portable sparse/dense BLAS/LAPACK operations using IRIS runtime. The MatRIS-IRIS co-design introduces three levels of abstraction to make the implementation completely architecture agnostic and provide highly productive programming. We demonstrate that MatRIS is portable without any change in source code and can fully utilize multi-device heterogeneous systems by achieving high performance and scalability on Summit, Frontier, and a CADES cloud node equipped with four NVIDIA A100 GPUs and four AMD MI100 GPUs. A detailed performance study is presented in which MatRIS demonstrates multi-device scalability. When compared, MatRIS provides competitive and even better performance than libraries from vendors and other third parties.

Monil, M. A. H.↗

Beyond Widgets: Validated Systems Energy Savings and Utility Custom Incentive Program Systems Trends

Energy efficiency upgrades to buildings to date through avenues such as utility incentive programs have been largely limited to component-based products (e.g., lamps, RTUs). While some utilities do provide ‘custom’ incentive programs with whole building and system level technical assistance, these programs require deeper levels of analysis, resulting in higher program costs. This results in custom programs being restricted to utilities with greater resources, and are typically applied mainly to large or energy-intensive facilities, leaving much of the market without cost effective access and incentives for these solutions. In addition, with increasingly stringent energy codes, cost effective component-based solutions that achieve significant savings are dwindling. Integrated building systems (e.g., integrated façade, HVAC and/or lighting solutions) can deliver higher savings (Regnier et al. 2017) that translate into large sector-wide savings if deployed at the scale of these programs. However, systems application poses a number of challenges – energy savings assessments are inherently more complex and are not easily suited to the deemed measure model, and implementation of systems can be more disruptive. This paper presents the outcomes of a project to develop validated utility incentive program packages for three specific integrated building systems, in collaboration with ComEd, a consortium of California Public Owned Utilities (CA POUs) (Northern California Power Agency(NCPA) and the Southern California Public Power Authority(SCPPA)), and Xcel Energy (CO, MN). Previous work described the potential for energy savings of these systems at the individual and market level, early test findings for the task-ambient lighting system, and described the work products to develop utility incentive programs (Regnier et al. 2016). This paper presents validated end use energy savings of all three systems showing energy savings of ~20% for automated shading combined with daylight dimming (does not include light fixture retrofit savings); 30-46% for task-ambient lighting systems combined with plug load occupancy controls, depending on technology package and office building size (no daylight dimming impacts); and ~94% in the south-façade daylit zone for workstation specific lighting systems with daylight dimming (including lighting retrofit and task tuning). Using a U.S. Department of Energy (DOE) reference building model (DOE 2018), this translates to whole building savings of 2-5% (large-medium commercial), 12-23% (large-small commercial), and 13-15% (medium-large commercial) for these systems respectively. Early findings from the utilities in deploying these systems through their incentive programs indicate that deployment methods such as direct install programs might be best suited for these integrated systems. Further, early findings from a scoping study across custom utility programs and federal retrofit programs indicate that component level retrofits are still prevalent even in these programs, pointing towards an opportunity for deeper energy savings deployment. High performance retrofit case studies demonstrate that deeper energy savings is possible through integrated approaches. Market stakeholder interviews indicate however that there is generally a low level of awareness of the potential for energy savings of these three integrated systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

HPE ultralit project (ARPA-E open program 2018) final report 15

The goal of the program was to build a fully integrated optical transceiver with >1 Tb/s and <1.5 pJ/bit operating at 50 ◦ C. Optical transceivers are critical components in high-performance-computers (HPC) and data centers, and the details of their implementation has a big impact on the total power consumption (energy efficiency) of an HPC system. Our proposed transceiver used three key enabling technologies. Firstly, SiGe avalanche photodetectors have record-low sensitivities, meaning that they can reach low bit error rates with very little light input. As a result, we can drive our lasers at a lower drive current, thus saving electrical power. Secondly, we use MOS-based capacitive tuning in our deinterleaver, modulator, and demultiplexer. Capacitive tuning allows for the tuning of photonic elements with zero static power consumption. Thirdly, we use quantum dots as the gain material in our light source. This allows us to efficiently use our light source at temperatures that are typically encountered in an HPCsystem. Our proposed optical transceiver consisted of a quantum dot comb laser as a light source, a booster SOA, MOS-based deinterleavers, MOS based ring modulators, MOS-based ring demultiplexers, and SiGe APDs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

JBlulce Data Acquisition Software for Macromolecular Crystallography

JBlulce (Java Beam Line Universal Integrated Configuration Environment is a data acquisition software for macromolecular crystallography conforming user interface of the SSRL Blulce that has become a de-factor standard in the field. Besides this interface conformity, JBlulce is a unique system in terms of architecture, spec, capability and software implementation. It features only two software layers, the JBlulce clients and the EPICS servers, as compared to three layers present in Blulce and most of similar systems. This layers reduction provides a faster communication with hardware and an easier access to advanced hardware capabilities like on-the-fly scanning. Then JBlulce clients are designed to operate in parallel with the other beamline controls which streamlines the tasks performed by staff such as beamline preparation, maintenance, auditing and user assistance. Another distinction is the deployment of multiple plugins that can be written in any programming language thus involving more staff into the development. further on, JBlulce makes use of unified motion controls allowing for easy scanning and optimizing of any beamline component. Finally, the graphic interface is implemented in Java making full use of rich Java libraries and Jave IDE for debugging. to compare, Blulce user interface is implemented with aging Tcl/tk language providing very restricted capabilities. JBlulce makes full use of the industrial power and wide drivers selection of EPICS in controlling hardware; all hardware communication is routed via multiple EPICS servers residing on local area network. JBlulce also includes several EPICS State Notation servers aimed at making hardware communication more robust. Besides using EPICS for controlling hardware, JBlulce extensively uses EPICS databases for efficient communications between multiple instances of JBlulce clients and JBlulce plugins that can run in parallel on different computers. All of the above makes JBlulce one of the biggest and most sophisticated EPICS client projects to date. JBlulce configuration is stored in my SQL database which provides flexibility in tuning the system. The database is also accessible by the plugins. From the users perspective JBlulce provides all standard features of data acquisition software for macromolecular crystallography plus such unique capabilities as one click beamline energy change that may involve switching undulator harmonics, mirrors lanes and beam realignment, automated diffraction rtastering for finding small crystals and sweet spots on poorly diffracting crystals with automated scoring of raster cells by the number of reflections; data collection along a vector; automated on-the-fly fluorescent tastering, a faster and lower-irradiation compliment to the diffraction raster; fully automated fluorescence measurements for MAD that include signal optimization, fast on the fly energy scanning and automated adapting of scan range to chemical shifts; fly-scan minibeam realignment; automated loop and crystal centering, controls for sample automounter, automated screening, data collection auditing, remote access and a lot more.

Stepanov, Sergey↗

Prediction and uncertainty quantification of shale well performance using multifidelity Monte Carlo

Uncertainty quantification is an integral component of reservoir management, especially considering the inherent uncertainty in subsurface systems. While a standard practice to estimate the uncertainty, Monte Carlo (MC) simulation is computationally intense when the sampling population comprises high-fidelity simulations. Alternatively, the Multi-fidelity Monte Carlo (MFMC) simulation overcomes this computational intensity by integrating low- and high-fidelity simulations. Our goal is to minimize the number of expensive high-fidelity simulations while maintaining accuracy and using numerous fast and cheap low-fidelity simulations to efficiently sample to input parameter space of interest. We selected gas production from unconventional wells to demonstrate the potential speedups and accuracy of the MFMC approach. The model fidelity usually determines the trade-off between accuracy and efficiency. While the high-fidelity model is more accurate, the low-fidelity model is more efficient. Our high-fidelity simulation includes reservoir simulations of a hydraulically fractured well. On the other hand, our low-fidelity model comprises the parallel-plate flow model. We used differential programming to efficiently solve the 1D flow model, where automatic differentiation is used to efficiently compute the gradients. We matched the production profile of high-fidelity simulations with our low-fidelity simulations. Then, we used a support vector regression to map the high- and low-fidelity input parameters. The mapping function is essential to tune the low-dimensional parameter space of the low-fidelity model to the high-dimensional parameter space of the high-fidelity model. We found that we can use a combination of 9 high fidelity and 10,000 low fidelity simulations to efficiently and accurately simulate pressure management. This method is at least two orders of magnitude faster than only using high-fidelity simulations. Finally, from a broader perspective, MFMC could efficiently estimate the uncertainty of various systems and models, integrating low- and high-fidelity models.

04 OIL SHALES AND TAR SANDS↗

A centralized-based method to determine the local voltage control strategies of distributed generator operation in active distribution networks

The increasing penetration of distributed generators (DGs) exacerbates the risk of voltage violations in active distribution networks (ADNs). The var capacity provided by DG inverters is a potential solution for voltage regulation. The conventional centralized control strategies limited by computation and communication burdens are difficult to meet the requirement of rapid voltage control. However, the local control strategies based on real-time measurements have a fast response to the frequent fluctuations of DG outputs. The performance of these local controllers depends on the tuning of the control parameters. This paper proposes a centralized-based method to determine the local voltage control strategies for DGs. A centralized parameter tuning model of control curves is built, in which and curves of DG inverters are mathematically formulated based on piecewise linearization. The original mixed-integer nonlinear programming (MINLP) model is converted into an effectively solved mixed-integer second-order cone programming (MISOCP) model using convex relaxation. The potential benefits of DG inverters are explored to regulate both reactive and curtailed active power, based on local voltage measurements. Case studies on a modified PG&E 69-node distribution system are carried out to verify the effectiveness of the proposed method. Results show that power losses of ADNs are significantly reduced and voltage profiles are also improved.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Envision Charlotte Project Final Report

The Envision Charlotte Project (EC Project), supported by partners at the Center for Climate and Energy Solutions, the University of North Carolina at Charlotte’s Center for Sustainably Integrated Buildings and Sites and the City of Charlotte, has successfully demonstrated that existing buildings can benefit from operations improvements and low-cost efficiency upgrades, and that behavioral change campaigns can be effectively designed for measurability, longevity and impact. Support from this grant gave Envision Charlotte and its partners the resources and flexibility to demonstrate a variety of approaches to improve coordination with stakeholders in the implementation of programs to reduce the consumption of energy, water and waste. The project team also gained insights into the motivations and abilities that influence stakeholder engagement in sustainability initiatives at multiple levels. Importantly, as this report describes, strong partnerships between nonprofits, industry partners and research institutions can produce tangible impacts and replicable results in building efficiency. Further, building operators working alongside student researchers can form productive relationships that can advance building energy management goals. Key Findings of the EC Project This project focused on advancing solutions to energy efficiency in U.S. commercial buildings. The Building Re-Tuning™ Training (BRT) developed by the U.S. DOE’s Pacific Northwest National Lab (PNNL), designed to detect energy savings opportunities and implement improvements with resources and online tools, provided the starting point for the curriculum developed by stakeholders in the EC Project. Although the project partners encountered some issues with data consistency, the overall project outcomes fell short of the energy savings stated in the original proposal, and the total participating building targets were lower than anticipated, important findings, outcomes and lessons learned were achieved. EC Project grantees observed that the PNNL BRT, as currently written, was not compatible with the skills of average frontline mechanical personnel in the Charlotte region where the grant program was performed. Frontline staff are not, typically, energy managers, engineers or building commissioning agents, but they can play a key role in building performance. As detailed in this report, the grantees therefore focused on changes to the BRT that improved the level of training and competency of the frontline workers in this region. Among the technical observations related to improving the BRT that were observed in the EC Project: centralized facilities management often has an impact on building performance; operators can be overly reliant on service contracts; individual behaviors matter, and technology cannot be viewed as a crutch; current Building Automation Systems (BAS) are often too complex to support building efficiency optimization, but BAS coupled with appropriate training can support better outcomes; the “perfectly optimized” building is not a near-term possibility, but better education, especially of executives and managers, on the role of behavioral intervention is a promising direction the building science community can and should pursue; a lack of standards and protocols, and competition between proprietary software from service contracts, remain challenges for this industry. These technical observations, in turn, informed the EC Project’s overall findings, which were: Accomplishing building efficiency is a process of education for all involved in the building design, construction and operation supply chain. Building operators, as a professional class, have an opportunity for further training and education that will lead to better on-the-job performance. An updated Building Re-Tuning™ Training curriculum, based on the findings of this report, could be an avenue for these operators’ professional development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Kokkos Ecosystem [Brief]

In 2016/2017, the field of High-Performance Computing (HPC) entered a new era driven by fundamental physics challenges to produce ever more energy and cost-efficient processors. Since the convergence on the Message-Passing Interface (MPI) standard in the mid-1990s, application developers enjoyed a seemingly static view of the underlying machine — that of a distributed collection of homogeneous nodes executing in collaboration. However, after almost two decades of dominance, the sole use of MPI to derive parallelism acted as a limiter to improved future performance. While MPI is widely expected to continue to function as the basic mechanism for communication between compute nodes for the immediate future, additional parallelism is required on the computing node itself if high performance and efficiency goals are to be realized. When reviewing the architectures of the top HPC systems today, the change in paradigm is clear: the compute nodes of the leading machines in the world are either powered by many-core chips with a few dozen cores each, or use heterogeneous designs, where traditional CPUs marshal work to massively parallel compute accelerators which has as many as 200,000 processing threads in flight simultaneously. Complicating matters further for application developers, each processor vendor has its own preferred way of writing code for their architecture.The Kokkos EcoSystem was released by Sandia in 2017 to address this new era in HPC system design by providing a vendor independent performance portable programming system for scientific, engineering, and mathematical software applications written in the C++ programming language. Using Kokkos, application developers can be more productive because they will not have to create and maintain separate versions of their software for each architecture, nor will they have to be experts in each architecture's peculiar requirements. Instead, they will have a single method of programming for the diverse set of modern HPC architectures. While Kokkos started in 2011 as a programming model only, it soon became clear that complex applications needed more. It is also critical to have a portable mathematical functions and developers need tools to debug their applications, gain insight into the performance characteristics of their codes and tune algorithm performance parameters through automated processes. The Kokkos EcoSystem addresses those needs through its three main components: the Kokkos Core programming model, the Kokkos Kernels math library, and the Kokkos Tools project.

97 MATHEMATICS AND COMPUTING↗

Feedback Control Approaches for Restoration of Power Grids from Blackouts

The automated restoration of power systems with variable energy resources is a timely problem to tackle. Automated restoration advice can support operators in deciding on strategic actions to restore power grids from a blackout with a mix of conventional and renewable generation resources. To this end, this paper frames the restoration process of power grids with solar resources as a nonlinear dynamic model with algebraic constraints in discrete time which is steered by feedback control loops. We discuss two feedback-control strategies based on greedy and reinforcement learning algorithms, and contrast their performance with restoration plans generated by a mixed-integer linear program. We found that the reinforcement learning algorithm infers restoration actions faster than the greedy one. However, the tuning process of the reinforcement learning parameters is slower than for the greedy one.

machine learning↗

Perpendicular Biased Ferrite Tuned Cavities for the Fermilab Booster

The aging Fermilab Booster RF system needs an upgrade to support future experimental program. The important feature of the upgrade is substantial enhancement of the requirements for the accelerating cavities. The new requirements include enlargement of the cavity beam pipe aperture, increase of the cavity voltage and increase in the repetition rate. The modification of the present traditional parallel biased ferrite cavities is rather challenging. An alternative to rebuilding the present Fermilab Booster RF cavities is to design and construct new perpendicular biased RF cavities, which potentially offer a number of advantages. An evaluation and a preliminary design of the perpendicular biased ferrite tuned cavities for the Fermilab Booster upgrade is described in the paper. Also it is desirable for better Booster performance to improve the capture of beam in the Booster during injection and at the start of the ramp. One possible way to do that is to flatten the bucket by introducing second harmonic cavities into the Booster. This paper also looks into the option of using perpendicularly biased ferrite tuners for the second harmonic cavities.

43 PARTICLE ACCELERATORS↗

FY23 Progress on Computational Modeling of the Water-Based NSTF

This report summarizes the system-level modeling effort by Argonne National Laboratory (Argonne) of the Natural convection Shutdown heat removal Test Facility (NSTF) in FY23. As a continuation of the modeling effort from FY22, this year’s work focuses on improving the RELAP5-3D model developed previously for two-phase flow simulations. The RELAP5-3D model is updated to more accurately capture the heat loss experienced by the facility. The updated model is compared against experimental data for benchmarking purposes of the RELAP5-3D input model. By correctly accounting for heat loss, the updated RELAP5-3D model can now predict the two-phase baseline case more accurately. The onset and the duration of instability are captured well by the model. Furthermore, analyses are performed to better understand the instability mechanism experienced by the flow where the expansion of the boiling boundary in the chimney is studied in details and the fundamental frequencies of the oscillations are obtained. The updated RELAP5-3D model is further compared against four fault conditions, namely the reduction of riser header inlet flow area, depletion of system inventory, blocked riser channels, and static boiling scenario. For each fault condition, minor modifications and tuning are performed to improve the predictions of the model. The purpose of the analyses is to investigate the capability of RELAP5-3D in predicting complex two-phase flows in possible accident scenarios in actual Reactor Cavity Cooling System (RCCS). Overall, the model is able to capture the behaviors and trends of these fault conditions relatively well. Some discrepancies remain between the experimental data and the predictions, many of which are likely due to the differences in the predicted and experimental vapor generation rate. Future work will focus on the continued development of the current RELAP5-3D input model of the NSTF to both improve the accuracy of the model’s predictive capability and continue supporting the experimental program needs. The mutually beneficial relationship between analysis and experimental efforts has become integral to the parent NSTF program, and the greater objective to fully understand and accurately predict the heat removal performance of a full scale RCCS concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

City-level impacts of building tune-ups: Findings from Seattle's building tune-ups program

Many U.S. cities are implementing policies to reduce greenhouse gas (GHG) emissions of their buildings. These range from building energy benchmarking and disclosure to building performance standards (BPS) that require buildings to meet specific targets of energy use or emissions. The City of Seattle adopted a climate action plan in 2013 that set a goal of zero net GHG emissions in the road transportation, buildings, and waste sectors by 2050, with a number of near and long term actions. Seattle implemented mandatory building tune-ups in 2016, applying to commercial buildings larger than 50,000 sqft. Building tune-ups1 involve assessment and implementation of operational and maintenance (O + M) improvements to achieve energy and water efficiency, such as changes to thermostat set points or adjusting lighting or irrigation schedules. Seattle's tune-ups program covered 27 such improvements in HVAC, lighting, domestic hot water, and envelope systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Power/energy use cases for high performance computing

Power and Energy have been identified as a first order challenge for future extreme scale high performance computing (HPC) systems. In practice the breakthroughs will need to be provided by the hardware vendors. But to make the best use of the solutions in an HPC environment, it will likely require periodic tuning by facility operators and software components. This document describes the actions and interactions needed to maximize power resources. It strives to cover the entire operational space in which an HPC system occupies. The descriptions are presented as formal use cases, as documented in the Unified Modeling Language Specification [1]. The document is intended to provide a common understanding to the HPC community of the necessary management and control capabilities. Assuming a common understanding can be achieved, the next step will be to develop a set of Application Programing Interfaces (APIs) to which hardware vendors and software developers could utilize to steer power consumption.

97 MATHEMATICS AND COMPUTING↗

GlusterFS One Storage Server to Rule Them All

GlusterFS is a Linux based distributed file system, designed to be highly scalable and serve many clients. Some reasons to use GlusterFS are: No centralized metadata server, Scalability, Open Source, Dynamic and live service modifications, Can be used over Infiniband or Ethernet, Can be tuned for speed and/or resilience and Flexible administration. It's useful for enterprise environments - virtualization; high performance computing (HPC) and it works with Mac, Linux and Windows clients. Conclusions are: (1) GlusterFS proved to have widespread capabilities as a virtual file system; (2) Scalability is very dependent upon the underlying hardware; (3) Lack of built-in encryption and security paradigm; and (4) Best suited in a general purpose computing environment.

99 GENERAL AND MISCELLANEOUS↗

Evaluating and Optimizing OpenCL Base64 Data Unpacking Kernel with FPGA

Development of applications using OpenCL targeting FPGAs is an emerging approach on heterogeneous computing systems. This paper uses the data unpacking algorithm in Base64 encoding as a case study to present programming and optimization techniques, and experimental results of the OpenCL-based implementations on an FPGA. We explain the algorithm and evaluate the performance of the kernel implementations with Intel's FPGA OpenCL SDK. The experimental results show kernel vectorization and duplication are two optimization techniques that can improve the kernel performance. The performance of kernel duplication is also closely related to the local work size. Our experiment shows 16-lane vectorization increases the bandwidth by a factor of 2 to 10 for large input data sizes. Moreover, the performance of kernel duplication using 16 compute units is 40% to 1.5% less than that of kernel vectorization depending on the input size. Tuning the local work size can improve the kernel performance by a factor of 3 to 23. For this kernel, using local memory is not an effective technique to improve the kernel performance because input data is not reused. A combination of vectorization and duplication achieves the highest performance of 12.3 GiB/s. Compared to an Intel Xeon E5 CPU and an Nvidia Tesla K80 GPU, the performance of the kernel on the Arria 10 FPGA is 6.7X faster than the CPU and 3X slower than the GPU. The performance per watt on the FPGA is 20.5X higher than the CPU and 1.19X lower than the GPU.

Base64 Encoding↗

TChem-atm (v2.0.0): scalable performance-portable multiphase atmospheric chemistry

We present TChem-atm, a performance-portable approach that enables efficient simulation of chemically detailed and multiphase atmospheric chemistry on modern heterogeneous computing architectures. Unlike previous efforts that rely on architecture-specific code or focus exclusively on gas-phase chemistry, TChem-atm supports fully coupled gas–aerosol systems with execution across CPUs, NVIDIA GPUs, and AMD GPUs through the Kokkos programming model. It integrates the flexible multiphase capabilities of the Community Atmospheric Model Chemistry Package (CAMP) with the high-performance kinetic routines of TChem, and includes automatic Jacobian construction with support for a range of stiff ODE solvers. In a proof-of-concept integration with the particle-resolved model PartMC, TChem-atm reproduces the existing PartMC–CAMP implementation within solver tolerances and delivers substantial GPU speedups, especially for large particle populations. Performance benchmarks reveal substantial speedups on GPU platforms, particularly for large particle populations, with consistent results across hardware backends. TChem-atm enables performance-portable execution across CPUs and GPUs, though optimal efficiency may require modest architecture-specific tuning (e.g., team and vector sizes), with up to a twofold improvement on the NVIDIA H100. It directly supports sectional and particle-resolved host models, while modal aerosol schemes require minor adaptation to provide particle-scale quantities such as representative diameters. By enabling chemically detailed, multiphase simulations with performance portability and host-model flexibility, TChem-atm facilitates the incorporation of advanced chemistry into atmospheric models.

Díaz-Ibarra, Oscar Homero [Sandia National Laborat↗

Assessments of data centers for provision of frequency regulation

There are numerous opportunities for data centers to participate in demand response programs considering their large energy capacities, flexible working environments and workloads, redundant design and operation, etc. As a type of demand response, frequency regulation requires fast response, and its potential is not fully explored by data centers yet. This paper proposes a synergistic control strategy for data center frequency regulation which uses both IT and cooling systems. It combines power management techniques at the server level with control of the chilled water supply temperature to track the regulation signal from the electrical market. A frequency regulation flexibility factor is also proposed to increase the IT capacity for frequency regulation. The performance of the control strategy is studied through numerical simulations using an equation based object-oriented Modelica platform designed for data centers. Simulation results show that with well-tuned control parameters, data centers can provide frequency regulation service in both regulation up and down. The performance of data centers in providing frequency regulation service is largely influenced by the regulation capacity bid, frequency regulation flexibility factor, workload condition, and cooling mode of the cooling system, and not significantly influenced by the time constant of chillers. In addition, compared with a server-only control strategy, the proposed synergistic control strategy can provide an extra regulation capacity of 3% of the design power when chillers are activated. Here, when chillers are deactivated, both strategies have a similar regulation capacity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Technical Note: Spot characteristic stability for proton pencil beam scanning

Purpose: The spot characteristics for proton pencil beam scanning (PBS) were measured and analyzed over a 16 month period, which included one major site configuration update and six cyclotron interventions. The results provide a reference to establish the quality assurance (QA) frequency and tolerance for proton pencil beam scanning. Methods: A simple treatment plan was generated to produce an asymmetric 9-spot pattern distributed throughout a field of 16 × 18 cm for each of 18 proton energies (100.0–226.0 MeV). The delivered fluence distribution in air was measured using a phosphor screen based CCD camera at three planes perpendicular to the beam line axis (x-ray imaging isocenter and up/down stream 15.0 cm). The measured fluence distributions for each energy were analyzed using in-house programs which calculated the spot sizes and positional deviations of the Gaussian shaped spots. Results: Compared to the spot characteristic data installed into the treatment planning system, the 16-month averaged deviations of the measured spot sizes at the isocenter plane were 2.30% and 1.38% in the IEC gantry x and y directions, respectively. The maximum deviation was 12.87% while the minimum deviation was 0.003%, both at the upstream plane. After the collinearity of the proton and x-ray imaging system isocenters was optimized, the positional deviations of the spots were all within 1.5 mm for all three planes. During the site configuration update, spot positions were found to deviate by 6 mm until the tuning parameters file was properly restored. Conclusions: For this beam delivery system, it is recommended to perform a spot size and position check at least monthly and any time after a database update or cyclotron intervention occurs. A spot size deviation tolerance of <15% can be easily met with this delivery system. Deviations of spot positions were <2 mm at any plane up/down stream 15 cm from the isocenter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗