Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance loss rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Photovoltaic Cleaning Frequency Optimization Under Different Degradation Rate Patterns

Dust accumulation significantly affects the performance of photovoltaic modules and its impact can be mitigated by various cleaning methods. Optimizing the cleaning frequency is essential to minimize the soiling losses and, at the same time, the costs. However, the effectiveness of cleaning lowers with time because of the reduced energy yield due to degradation. Additionally, economic factors such as the escalation in electricity price and inflation can compound or counterbalance the effect of degradation on the soiling mitigation profits. The present study analyzes the impact of degradation, escalation in electricity price and inflation on the revenues and costs of cleanings and proposes a methodology to maximize the profits of soiling mitigation of any system. Here, the energy performance and soiling losses of a 1 MW system installed in southern Spain were analyzed and integrated with theoretical linear and nonlinear degradation rate patterns. The Levelized Cost of Energy and Net Present Value were used as criteria to identify the optimum cleaning strategies. The results showed that the two metrics convey distinct cleaning recommendations, as they are influenced by different factors. For the given site, despite the degradation effects, the optimum cleaning frequency is found to increase with time of operation.

14 SOLAR ENERGY↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Wells RWM 6 and RWM 7

Hydrologic tests were conducted on the Lost Lake Aquifer Zone (LLAZ) at recovery wells RWM 6 and RWM 7 in accordance with the approved test plan (Dixon, 2023). The objective of the testing was to determine well performance parameters of RWM 6 and aquifer hydraulic properties near RWM 6 and RWM 7. Tests at RWM 6 consisted of a step-drawdown test to determine well performance parameters, a constant rate pump test to determine aquifer hydraulic properties, and an aquifer recovery test also used to determine aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. Prior to testing at RWM 6, a constant rate pump test was conducted at RWM 7. Data from this testing was used to determine aquifer hydraulic properties near RWM 7.

42 ENGINEERING↗

Parametric analysis of anodic degradation mechanisms for fast charging lithium batteries with graphite anode

In this work, we report the impact of the temperature-driven synergistically-coupled anodic degradation mechanisms on the electrochemical performance of lithium batteries with graphite anode over multiple cycles. Temperature dependence of electrochemical reactions and damage mechanisms, such as solid electrolyte interface (SEI) growth, lithium plating/stripping, dead lithium storage/dissolution, and film cracking are incorporated into the degradation model. Results of a parametric analysis are presented, evaluating the effects of charging rates (1–6 C), operating temperatures (-15 – 45°C) and electrode design parameters, on the relative performance fade in the lithium-ion battery. Thermo-electrochemical process maps are developed to provide insights into the relationship between electrode performance and failure mechanisms. The simulation results predict a severe capacity loss due to lithium plating at low temperatures, which is further aggravated at high charging rates. A common strategy for mitigating lithium plating, through charging at high temperatures, also results in rapid capacity loss due to accelerated SEI formation. Simulation results are used to identify the combination of operating conditions and electrode design parameters that improve the electrochemical performance of the battery. These results demonstrate an opportunity to design safe and high-performance lithium-ion batteries, guided by anodic degradation models.

Battery design↗

Photovoltaic module antireflection coating degradation survey using color microscopy and spectral reflectance

Abstract Commercial antireflective coatings (ARCs) on photovoltaic (PV) module glass can improve module power by 2.5%–3.0%, but their long‐term field performance requires additional study. In this paper, we investigate ARC performance on fielded modules using two nondestructive techniques: reflectance spectroscopy and RGB microscopy, finding a large variation in coating durability and performance. For new coatings, the fleet average nominal power enhancement is 2.8%. This power enhancement is observed to degrade at approximately −0.05%/year absolute over the first 8 years of fielding in arrays that are not regularly cleaned. Interferometry and imaging results imply that coating loss for these modules is due to slow chemical thinning of the initial 125 nm thick coating by 1.4 to 5.0 nm/year. Due to the physics of interference coatings, the performance loss is projected to accelerate as the coating is further thinned, resulting in a coating lifetime (time to 80% of initial performance) of 7.5 to 25 years. At the higher 5.0 nm/year coating loss rates, we estimate that −0.14%/year power degradation of the module can be attributed solely to ARC degradation over the first 20 years. Extreme coating loss is observed on some modules where after 8 years fielding, the coating can be completely removed with a single wet wipe with a lens tissue. A case study is also presented comparing ARC and noncoated modules installed at a single site in 2013. We find that the ARC modules have a 2.6% higher soiling power loss than the noncoated modules; this exceeds the ARC power enhancement of 2.4% and leads to the surprising conclusion that the ARC lowers production for modules in this location due to increased soiling. These results demonstrate that RGB microscopy is a powerful, field‐capable, and quantitative characterization technique for assessing degradation of PV module ARCs.

Karin, Todd↗

Optimization of target lifetime for production of 14 MeV neutrons

Two methods are examined for extending the life of tritium targets for production of 14 MeV neutrons by the 3 H( 2 H,n) 4 He nuclear reaction. With thick film targets the neutron production rate decreases with time due to isotope exchange of tritium in the film with implanted deuterium. Here, the target life is maximized by operating the target at elevated temperature where the implanted deuterium mixes by thermal diffusion throughout the entire thickness of the film. The number of neutrons obtained from a target is then proportional to the initial tritium content of the film. A novel thin-film target design was also developed and tested. With these thin-film targets, the incident deuterium is implanted through the tritide into the underlying substrate material. A thin permeation barrier layer between the tritide film and substrate, reduces the rate of tritium loss from the tritide film. Good thin-film target performance was achieved using W and Fe for the barrier and substrate materials respectively. Thin-film targets were fabricated and tested and shown to produce similar number of neutrons as thick-film targets while using only a small fraction of the amount of tritium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chemical Kinetics of the Autoxidation of Poly(ethylenimine) in CO 2 Sorbents

The oxidative degradation rates of a CO 2 sorbent composed of a mesoporous alumina impregnated with poly- (ethylenimine) (PEI) are measured under systematically varied conditions and a reaction rate law is created. Good agreement is shown between the rate of oxidation obtained via in situ calorimetric heat measurement during oxidative degradation reactions and the loss of CO 2 capture performance presented as amine efficiency (mol CO 2 /mol amine). PEI mass loss and elemental composition are tracked over the course of the reaction and used in conjunction with the oxidation rate measurements to shed insight into the oxidation reaction(s). These data, in combination with measurements of the heat of reaction, suggest a common reaction set across the range of temperatures, oxygen concentrations, and sorbent compositions tested. The data are consistent with the basic autoxidation scheme (BAS), the accepted mechanism of autoxidation of aliphatic polymers. We propose a lumped kinetic model to describe the oxidation reaction set and estimate an activation energy of 105 kJ/mol and an oxygen reaction order of 0.5–0.7 from the data accordingly. Furthermore, these parameters can be incorporated into process cycle models to estimate the material lifetime, a critical uncertainty in the deployment of DAC technologies.

36 MATERIALS SCIENCE↗

Extended Interfacial Stability through Simple Acid Rinsing in a Li-Rich Oxide Cathode Material

Layered Li-rich Ni, Mn, Co (NMC) oxide cathodes in Li-ion batteries provide high specific capacities (>250 mAh/g) via O-redox at high voltages. However, associated high-voltage interfacial degradation processes require strategies for effective electrode surface passivation. Here, we show that an acidic surface treatment of a Li-rich NMC layered oxide cathode material leads to a substantial suppression of CO 2 and O 2 evolution, ~90% and ~100% respectively, during the first charge up to 4.8 V vs. Li +/0 . CO 2 suppression is related to Li 2 CO 3 removal as well as effective surface passivation against electrolyte degradation. This treatment does not result in any loss of discharge capacity and provides superior long-term cycling and rate performance compared to as-received, untreated materials. We also quantify the extent of lattice oxygen participation in charge compensation (“O-redox”) during Li + removal by a novel ex-situ acid titration. Our results indicate that the peroxo-like species resulting from O-redox originate on the surface at least 300 mV earlier than the activation plateau region around 4.5 V. X-ray photoelectron spectra and Mn -L X-ray absorption spectra of the cathode powders reveal a Li + deficiency and a partial reduction of Mn ions on the surface of the acid-treated material. More interestingly, although the irreversible oxygen evolution is greatly suppressed through the surface treatment, our O K-edge resonant inelastic X-ray scattering shows the lattice O-redox behavior largely sustained. The acidic treatment, therefore, only optimizes the surface of the Li-rich material and almost eliminates the irreversible gas evolution, leading to improved cycling and rate performance. This work therefore presents a simple yet effective approach to passivate cathode surfaces against interfacial instabilities during high-voltage battery operation.

25 ENERGY STORAGE↗

ComStock Measure Documentation: Photovoltaics With 40% Rooftop Coverage

This study investigates the impact of adding 40% rooftop coverage of photovoltaics to the U.S. commercial building stock. Panels are modeled as higher performance with 21% rated efficiency, 96% inverter efficiency, 1.10 DC/AC ratio,14% system losses, and azimuth/tilt angles that vary by location. Total panel area is modeled at 40% of the roof area for each model. Total rated PV power for a building is based on the calculated total panel area and the assumed efficiency of 21%. This measure is applied to all buildings modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vacuum-assisted carbon molecular sieve membrane reactor for non-oxidative ethane dehydrogenation

Non-oxidative ethane dehydrogenation (EDH) is equilibrium-limited and endothermic. Selective hydrogen removal using a gas-permeable membrane within the EDH reaction zone can overcome the thermodynamic equilibrium, enabling higher ethane conversions. Employing vacuum as the permeation driving force, rather than a sweep gas, enhances the industrial viability of membrane reactors by eliminating additional post-reaction separation units. This study presents a membrane reactor that integrates H 2 -permeable carbon molecular sieve (CMS) hollow fiber membranes embedded in a fixed bed of cobalt in a dealuminated beta zeolite (Co@DeAl-BEA) catalyst, utilizing a vacuum to remove hydrogen efficiently. The CMS membrane exhibits high hydrogen permeance and an excellent H 2 /C 2 H 6 separation factor. The membrane reactor significantly enhanced the ethane conversion under reaction conditions comparable to those reported in the literature. A Langmuir-Hinshelwood kinetic rate expression was developed and incorporated into a one-dimensional steady-state reactor model. The experimentally validated model indicates that increasing the number of hollow fibers improves ethane conversion, although ethane loss to the permeate limits the benefit. The contact area between the catalyst and the membrane limits the reactor performance more than the catalytic throughput. Furthermore, we find that the location of the catalyst packing relative to the hollow fiber membranes influences ethane loss and conversion. Higher reactor pressures and inlet ethane flow rates improve space-time yield at the expense of lower ethane conversion. Increasing reactor temperature or packing length promotes both performance metrics. The EDH membrane reactor demonstrated durability over 200 h of continuous operation, maintaining record-low deactivation rates and high ethylene selectivity. Protocols for catalyst regeneration were developed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of an All-Aqueous Thermally Regenerative Redox Flow Battery to Support Fossil Fuel Assets

Low-temperature thermal energy, a largely untapped resource, holds significant promise for large-scale electrical power generation globally. Various stationary sources, including industrial entities and thermal power plants, emit considerable low-temperature heat that currently remains unutilized. This energy is often overlooked because its low temperature renders it unsuitable for efficient power generation using conventional methods. However, current research is exploring diverse technologies capable of converting low-temperature heat into grid-scale power, aiming to enhance grid efficiency, further decarbonization initiatives, and facilitate a shift toward more decentralized power systems. One such innovative technology is the thermally regenerative battery (TRB), noted for its high power and energy densities compared to similar technologies, positioning it as a potential game-changer in power generation. TRBs integrate two scalable and well-established unit operations: a redox flow battery and a distillation column. This integration suggests that once an effective TRB chemistry is established, the pathway to commercialization could be expedited. The copper-based thermally regenerative ammonia battery (Cu aq -TRAB) stands out as the first TRB that circumvents electrodeposition/dissolution reactions, stabilizing Cu(I) and Cu(II) within the electrolyte and maintaining stability of all electroactive species in an aqueous phase. This stabilization has led to improvements in coulombic efficiency, open circuit potential, and copper solubility, thereby enhancing power density, energy density, and overall energy efficiency. Preliminary tests were conducted to determine the effects of various electrolyte species on the performance metrics of the battery, both theoretically and experimentally. These tests revealed that the solubility of copper in the Cu aq -TRAB electrolyte was constrained by the Cu(I)-NH 3 complex. Adjusting the background electrolyte to 5 M NH4Br and the ligand concentration to 4 M NH 3 enabled the copper concentration to reach a maximum of 0.6 M. This modification led to an estimated theoretical maximum energy density of 9.5 Wh L -1 for the Cu aq -TRAB. Additionally, full cell testing indicated a tradeoff between peak power and energy density with varying copper and ammonia concentrations. Increasing the applied current density during discharge linearly raised the average power output, with a minimal reduction in energy density due to a balance between higher ohmic overpotential and reduced time for undesirable ammonia crossover. Furthermore, a comprehensive numerical sensitivity analysis of the complete Cu aq -TRAB system was performed. This analysis aimed to assess how the battery and the distillation column responded to changes in system input parameters, providing insights into optimal research directions for enhancing system performance. The analysis revealed that at room temperature, battery power was significantly more sensitive to ohmic losses than to mass transfer, with reaction rates having minimal impact. This trend continued even at higher temperatures. Also, the thermal energy required for ammonia separation was studied, showing that increased temperatures generally reduced energy requirements, except in low-pressure scenarios above 65 °C. An investigation into membrane performance in the Cu aq -TRAB was undertaken, given the significant impact of ammonia transport control and ohmic losses on system performance. Various membranes were evaluated to identify key performance metrics. Among the tested membranes, Selemion CMVN exhibited the highest performance, with a peak power density of 84 mW cm -2 and average values of 26 ± 6.8 mW cm -2 for power density and 2.9 Wh L -1 for energy density at an applied current density of 50 mA cm -2 . An economic assessment indicated a levelized cost of storage at $410 per MWh under optimal conditions, highlighting the commercial potential of the Cu aq -TRAB when utilizing cost-effective, readily available materials.

25 ENERGY STORAGE↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Well RWM001R

An aquifer pumping test was conducted on the Lost Lake Aquifer Zone (LLAZ) at the recently installed recovery well RWM001R in accordance with the approved test plan (Dixon, 2024). The objective of the testing was to determine baseline well performance parameters and aquifer hydraulic conductivity. This testing consisted of two step-drawdown tests to determine well performance properties and two constant pumping rate aquifer tests with recovery periods to determine aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. The results of the step-drawdown testing are presented in Tables ES1 and ES2 whereas the results of the constant pumping rate testing are presented in Table ES3. The average specific capacity of RWM001R operating at pump capacity (~54 gpm) was 2.2 gpm/ft using data from the final step of both tests. The average well efficiency determined from both step-drawdown tests was 56% using data from the final step of both tests. For both step-drawdown tests, well efficiency was inversely related to the pumping rate with the average efficiency decreasing from approximately 79% to 56%. Aquifer head loss coefficients from both tests were comparable (Table ES2).

54 ENVIRONMENTAL SCIENCES↗

Hot Hydrogen Exposure of U x Zr 1-x C y Nuclear Fuel: The Effect of Additional Carbon

Nuclear thermal propulsion (NTP) using hydrogen as propellant in a solid-state fission reactor to reach temperatures of up to 3000K can achieve significantly higher specific impulse than chemical propulsion. A promising fuel that is again considered for NTP is U x Zr 1-x C y . To reduce the overall mass loss as well as the uranium fuel loss, a range of experiments using additional carbon in hot hydrogen (2600 K, 6 SLPM flow rate) were performed for up to 5-6 h. Both a CH 4 addition (0.1 and 0.2 vol%) in the hydrogen stream and the use of sacrificial graphite pieces upstream of the samples were tested, with sample compositions from 5 at% UC to 30 at% UC. The results showed a strong reduction of mass loss, up to a factor of 3, as well as a reduction of surface uranium losses in the presence of additional carbon in the atmosphere. Even with additional carbon in the atmosphere, material with 30 at% UC was not stable, but material with 20 at% UC was stable for up to 6h. The sample surfaces showed texturing after processing, possibly by grain growth on the surface. This led to a separation into grains with high uranium content close to the (100)-orientation, and with low uranium content in grains close to the (111)-orientation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Field Testing of Self-Healing Metallic Coatings for Internal Corrosion Protection of Natural Gas Pipelines

Internal corrosion occurs in natural gas pipelines primarily due to the presence of water, carbon dioxide, and hydrogen sulfide. Internal corrosion can eventually result in leakage, cracks, and rupture of the pipeline. The objective of this work is to mitigate internal corrosion in steel pipelines transporting natural gas using cold spray coatings. The corrosion behavior of carbon steel coated with self-healing zinc chromium (ZnCr) and zinc niobium (ZnNb) cold spray coatings was investigated in a natural gas environment. For comparison purposes, hot-dip galvanized steel (HDGS) was tested under the same conditions as cold spray coatings. The field test was performed at the NW Natural gas storage facility in Mist, Oregon. The field test was conducted in a 6-inch diameter pipe transporting wet natural gas out of an underground storage well at 500 psi and 4.4 °C. The coupons were tested for 15 and 32 days under stagnant and flow conditions, respectively. Weight loss method was used to measure the corrosion rate of metallic coatings. Post-corrosion surface characterization was performed on the specimen using a scanning electron microscopy (SEM) equipped with energy dispersive X-ray spectroscopy (EDS). Crystalline phases were determined by X-ray diffraction (XRD). The field-test results confirmed that the metallic coatings provided corrosion protection of carbon steel exposed to wet natural gas under stagnant and flow conditions. The formation of the ZnCO 3 layer on top of ZnNb and ZnCr coatings led to passivation of the coatings which helps to reduce the self-corrosion. These layers form a barrier for diffusion of corrosive species to the surface.

03 NATURAL GAS↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization through Integration of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Development of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

A. Development of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗