Engineering PapersSearch

SEARCH · Engineering Papers

Results for “peak load reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Blended Buffet-Load-Alleviation System for Fighter Airplane

The capability of modern fighter airplanes to sustain flight at high angles of attack and/or moderate angles of sideslip often results in immersion of part of such an airplane in unsteady, separated, vortical flow emanating from its forebody or wings. The flows from these surfaces become turbulent and separated during flight under these conditions. These flows contain significant levels of energy over a frequency band coincident with that of low-order structural vibration modes of wings, fins, and control surfaces. The unsteady pressures applied to these lifting surfaces as a result of the turbulent flows are commonly denoted buffet loads, and the resulting vibrations of the affected structures are known as buffeting. Prolonged exposure to buffet loads has resulted in fatigue of structures on several airplanes. Damage to airplanes caused by buffeting has led to redesigns of airplane structures and increased support costs for the United States Air Force and Navy as well as the armed forces of other countries. Time spent inspecting, repairing, and replacing structures adversely affects availability of aircraft for missions. A blend of rudder-control and piezoelectric- actuator engineering concepts was selected as a basis for the design of a vertical-tail buffet-load-alleviation system for the F/A-18 airplane. In this system, the rudder actuator is used to control the response of the first tail vibrational mode (bending at a frequency near 15 Hz), while directional patch piezoelectric actuators are used to control the second tail vibrational mode (tip torsion at a frequency near 45 Hz). This blend of two types of actuator utilizes the most effective features of each. An analytical model of the aeroservoelastic behavior of the airplane equipped with this system was validated by good agreement with measured results from a full-scale ground test, flight-test measurement of buffet response, and an in-flight commanded rudder frequency sweep. The overall performance of the system was found to be characterized by reductions, ranging from 70 to 30 percent, in vertical-tail buffeting under buffet loads ranging from moderate to severe. These reductions were accomplished with a maximum commanded rudder angle of +/-2deg at 15 Hz and about 10 lb (.4.5 kg) of piezoelectric actuators attached to the vertical tail skin and operating at a peak power level of 2 kW. By meeting the design objective, this system would extend the vertical-tail fatigue life beyond two aircraft lifetimes. This system is also adaptable to other aircraft surfaces and other aircraft

Moses, Robert W.

ComStock Measure Documentation: Thermostat and Lighting Control for Load Shedding

This report describes the modeling methodology for an upgrade package of two end-use savings shape measures - Thermostat Control for Load Shedding and Lighting Control for Load Shedding - and briefly introduces key results. The package combines thermostat control for load shedding and lighting control for load shedding measures to reduce the HVAC and lighting load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then relaxes the thermostat setpoints and dims the lighting level from the original schedules during the peak window to reduce the peak demand. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 3%-10% daily peak demand reduction performance for applicable buildings, and 0.97% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Effect of Various Blade Modifications in Performance of a 16-Stage Axial-flow Compressor. IV - Effect on Over-all Performance Characteristics of Decreasing Twelfth through Fifteenth Stage Stator-blade Angles 3 deg and Increasing Stator Angles in the Inlet Stages

The performance of a 16-stage axial-flow compressor, in which two modifications of unloaded inlet stages were combined with loaded exit stages, has been determined. In the first modification the exit stages were loaded by decreasing the twelfth through fifteenth stage stator angles 3 deg. as compared with the blade angles in the original compressor, and the inlet stages were unloaded by increasing the blade angles the following amounts: guide vanes and first-stage stator, 6 deg; second- and third-stage stators, 4 deg.; and fourth-stage stators, 3 deg. The over-all performance of this configuration was compared with that of the compressor with the original blade angles. The peak efficiency was increased at all speeds below design and the weight flow was higher at speeds below 80 percent of design, the same at 80 percent of design, and lower at speeds abovce 80 percent of design. The maximum reduction in weight flow occurred at design speed. The surge limit line was higher at speeds between 75 and 90 percent of design when presented on a pressure ratio against weight flow basis. The second configuration was the same as the first with the exception that the second-, third-, and fourth-stage stator blade angles were the same as in the compressor with the original blade angles. A comparison of the performance of this configuration with that of the compressor with the original blade angles showed the same general trends of changes in performance as the first configuration. Comparisons were made of compressor configurations to show the effects upon the performance of decreased loading in the inlet stages. Below 75 percent of design speed, decreased loading results in increased weight flow and peak efficiency; above 80 percent of design speed, decreased loading in the inlet stages results in decreased weight flow and small changes in peak efficiencies. Between 75 and 90 percent of design the changes in surge weight flow and pressure ratio were such that the surge limit line was raised with decreased loading in the inlet stages when presented as pressure ratio against weight flow.

Hatch, James E.

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING

Reduced In-Plane, Low Frequency Helicopter Noise of an Active Flap Rotor

Results from a recent joint DARPA/Boeing/NASA/Army wind tunnel test demonstrated the ability to reduce in-plane, low frequency noise of the full-scale Boeing-SMART rotor using active flaps. Test data reported in this paper illustrated that acoustic energy in the first six blade-passing harmonics could be reduced by up to 6 decibels at a moderate airspeed, level flight condition corresponding to advance ratio of 0.30. Reduced noise levels were attributed to selective active flap schedules that modified in-plane blade airloads on the advancing side of the rotor, in a manner, which generated counteracting acoustic pulses that partially offset the negative pressure peaks associated with in-plane, steady thickness noise. These favorable reduced-noise operating states are a strong function of the active flap actuation amplitude, frequency and phase. The associated noise reductions resulted in reduced aural detection distance by up to 18%, but incurred significant vibratory load penalties due to increased hub shear forces. Small reductions in rotor lift-to-drag ratios, of no more than 3%, were also measured

Sim, Ben W.

Space Shuttle solid rocket booster initial water impact loads and dynamics - Analysis, tests, and flight experience

A series of scale model tests, finite element dynamic response analyses and full scale segment tests have been performed for purposes of developing design criteria for the initial water impact loading conditions applied to the internal stiffener rings located in the aft skirt portion of the Space Shuttle Solid Rocket Booster (SRB). In addition, flight experience has yielded information relative to structural reinforcement requirements. This paper discusses the test and analysis methods and summarizes significant results. It is noted that, although scale model test data are valuable for identifying trends, they have shortcomings concerning definition of full scale design loads criteria. Also, the frequently used static equivalent loads definition approach is not applicable for this type impact loading condition applied to an aft skirt type structure. Various types of ring structural fixes, including the addition of selected types of foam, are presented as well as associated full scale segment test results. Depending on the type and contour shape of the foam, reductions on applied pressures and peak measured strains over 50 percent are noted.

Kross, D. A.

ComStock Measure Documentation: Thermostat and Lighting Control for Load Shedding + Photovoltaics With 40% Rooftop Coverage

This report describes the modeling methodology for an upgrade package of two end-use savings shape measures - Thermostat Control for Load Shedding and Lighting Control for Load Shedding - and briefly introduces key results. The package combines thermostat control for load shedding, lighting control for load shedding, and PV with 40% rooftop coverage measures to reduce the net building load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then relaxes the thermostat setpoints and dims the lighting level from the original schedules during the peak window to reduce the peak demand, while applying the fixed rooftop PV application for onsite electricity generation. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 5%-15% daily peak demand reduction performance for applicable buildings, and around 1% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

14 SOLAR ENERGY

Electrochemical production of H 2 O 2 on palladium-based clusters driven by metal–support interaction

Utilizing palladium (Pd) clusters as active sites offers a promising route to minimize noble metal consumption in electrochemical hydrogen peroxide (H 2 O 2 ) production. In this work, we present a synthesis approach for anchoring Pd-based clusters onto carbon-supported CeO 2 nanosubstrates to enable efficient H 2 O 2 generation via the two-electron oxygen reduction reaction (ORR) pathway. By systematically adjusting Pd loading, we evaluated its impact on H 2 O 2 yield and production rate. The catalyst with the lowest Pd content (0.027 wt%) exhibited outstanding performance, achieving 97% H 2 O 2 selectivity, 94.2 faradaic efficiency at 0.7 V vs. RHE, and a peak production rate of 195.8 mol g Pd −1 h −1 . A formulation containing 0.35 wt% Pd delivered a peak ORR mass activity nearly three times as high as that of commercial 10 wt% Pd/C, while retaining comparable electrochemical stability. These enhancements are attributed to synergistic effects among isolated PdO clusters, CeO 2 nanocrystals, and the conductive carbon support, which together facilitate oxygen adsorption and promote the two-electron ORR pathway. Analysis after accelerated durability testing further revealed a tendency toward cluster agglomeration and mass transfer from smaller to larger nanocrystals, indicative of a coarsening mechanism. Overall, this study underscores the promise of low-Pd PdO–CeO 2 –carbon hybrid catalysts for scalable and efficient H 2 O 2 electrosynthesis, while highlighting stability as a critical area for future improvement.

36 MATERIALS SCIENCE

Advanced axial field D.C. motor development for electric passenger vehicle

A wound-field axial-flux dc motor was developed for an electric vehicle drive system. The motor is essentially an axial-flux version of the classical Gramme-ring winding motor, but the active conductors are recessed into slots cut into the two opposite faces of the laminated tape-wound core ring. Three motors were built and tested in the program. The second (functional) model was a six-pole machine which weighed 88.5 kg. It developed 16.9 km (33.0 hp), and a max speed of 4800 rpm. Full load efficiency was 92% and predicted SAE D-cycle efficiency was 88%. The last engineering) model was a 4-pole machine with compoles, allowing a weight reduction to 45 kg (100 lbs.) while addressing some manufacturability problems. The engineering model was rated at 13.2 kw (17.6 hp) at 3000 rpm, with a peak power of 19.8 km (26.4 hp) and a max speed of 7200 rpm. Initial test results on this motor showed poor commutation and efficiency; the program was terminated without resolution of these problems.

Jones, W. J.

The Sensitivity of Simulated Storm Structure and Intensity to the Temperature at the Lifted Condensation Level

Prior parameter space studies of simulated deep convection are extended to embrace variations in the ambient temperature at the Lifted Condensation Level (LCL). Within the context of the parameter space study design, changes in LCL temperature are roughly equivalent to changes in the ambient precipitable water. Two series of simulations are conducted, one with a warm LCL that is associated with approximately 60 mm of precipitable water, and another with LCL temperatures 8 C cooler, so that PW is reduced to roughly 30 mm. The sets of simulations include tests of the impact of changes in the buoyancy and shear profile shapes and of changes in mixed and moist layer depths, all of which have been shown to be important in prior work. Simulations discussed here feature values of bulk convective available potential energy (CAPE) of 800, 2000, or 3200 Joules per kilogram, and a single semicircular hodograph having radius of 12 meters per second, but with variable vertical shear. The simulations reveal a consistent trend toward stronger peak updraft speeds for the cooler LCL temperature (reduced PW) cases, if all other environmental parameters are held constant. Roughly comparable increases in updraft speeds are noted for all combinations of LCL and level of free convection heights. These increases in updraft strength are evidently the result of both the reduction of condensate loading aloft and the lower altitudes at which the latent heat release by freezing and deposition commences in the cooler, low-PW environments. Because the latent heat of fusion adds relatively more energy to the updrafts at low CAPE, those storms show more strengthening at low PW than do the larger CAPE storms. As expected, maximum storm precipitation rates tend to diminish as PW is decreased, but only slightly, and by amounts not proportionate to the decrease in PW. The low-PW cases thus actually feature larger environment-relative precipitation efficiency than do the high-PW cases. In addition, more hail reaches the surface in the low-PW cases because of reduced melting in the cooler environments.

McCaul, Eugene W., Jr.

Fatigue-environment interactions in a SiC/Ti-15-3 composite

Load-controlled isothermal and nonisothermal fatigue lives of a (0-deg)s SiC/Ti-15-3 were evaluated at temperatures between 150 and 550 C and a target strain range of about 0.45 percent. In nonisothermal fatigue tests, load was first cycled at minimum temperature and then temperature was cycled at zero load. For fatigue tests with peak temperatures at or above 300 C, fatigue life was dramatically reduced compared to that at 150 C. The shortest life was produced by the nonisothermal test with the greatest temperature range (Delta T = 400 C) and highest peak temperature (T(max) = 550 C). Vacuum testing showed that much of the life reduction under isothermal and nonisothermal conditions was related to environmental effects, although the nature of the fatigue-environment interaction was decidedly different for the isothermal and nonisothermal test cycles which were studied.

Gayda, J.

An experimental and numerical investigation of HD diesel engine DOC efficiency in oxidizing NO to NO 2

Reducing pollutant emissions from heavy-duty (HD) diesel engines is critical due to their significant environmental impact, particularly concerning NOx emissions. Understanding and optimizing modern diesel oxidation catalyst (DOC) and selective catalytic reduction (SCR) performance is essential for improving exhaust aftertreatment (EAT) system efficiency to meet stringent emissions regulations. The oxidation of nitric oxide (NO) to nitrogen dioxide (NO 2 ) in DOC plays a key role in improving SCR efficiency in reducing NO x . This study investigates the DOC performance in oxidizing NO to NO2 and its impact on the SCR efficiency of a 2021 MY Navistar E39 HD diesel engine. The influence of engine speed, load, exhaust gas temperature, and composition on DOC efficiency is experimentally investigated. The relationships between DOC inlet temperature, oxygen availability and NO 2 /NO x ratio at the DOC inlet are examined to better understand their effects on the overall DOC efficiency. The results indicate that DOC NO oxidation efficiency is highly dependent on exhaust temperature, with optimal oxidation occurring within a specific temperature range (275-350°C). Below this threshold, the chemical reactions are kinetically limited, while at higher temperatures, thermodynamic constraints reduce the efficiency of DOC in oxidizing NO to NO 2 . The experimental data further reveal that the NO 2 /NO x ratio peaks at medium loads before declining at higher loads due to reduced residence time and mass transfer effects. Additionally, the SCR NO x conversion efficiency is significantly influenced by the NO 2 /NO x ratio, achieving peak performance when the NO 2 /NO x ratio approaches 0.5. A DOC chemistry model was developed and validated against the experimental data to predict DOC oxidation behavior under various operating conditions. The findings of this study provide insights into the interdependencies between DOC and SCR performance, contributing to the optimization of SCR systems for optimized NOx reduction.

33 ADVANCED PROPULSION SYSTEMS

Multi-Agent Hierarchical Deep Reinforcement Learning for HVAC Control With Flexible DERs

As electricity consumption in commercial and residential buildings continues to rise, reducing energy costs presents an increasing challenge. Heating, ventilating, and air-conditioning (HVAC) systems, which typically account for 40%-50% of a building's energy use, are prime targets for energy savings. Intelligent control of HVAC temperature through the exploitation of HVAC load flexibility brings significant potential to reduce energy consumption and electricity expenses. The nonlinear models of HVAC systems challenge traditional control methods, while the uncertainty introduced by HVAC load flexibility complicates distributed energy resource (DER) management using conventional optimal dispatch techniques. In response to these challenges, we propose a hierarchical multi-agent deep reinforcement learning (DRL) approach. The lower-level agents focus on balancing comfort and energy conservation, while the upper-level DRL agents optimize the use of DERs to reduce peak demand based on the control outcomes of the HVAC by the lower-level agents. Here, in the upper-level agents, we incorporate a multi-agent structure based on ensemble learning, which acts based on historical and current data without relying on precise load forecasting to address the delayed rewarding issue in DRL. This allows for the effective reduction of energy costs. The proposed method is tested using a real-world microgrid comprising 413 buildings in Southern California, and the results demonstrate that our approach can significantly reduce overall electricity bills while ensuring the comfort of consumers and residents.

24 POWER TRANSMISSION AND DISTRIBUTION

Force-velocity and power characteristics of rat soleus muscle fibers after hindlimb suspension

The effects of 1, 2, and 3 wk of hindlimb suspension (HS) on force-velocity and power characteristics of single rat soleus fibers were determined. After 1, 2, or 3 wk of HA, small fiber bundles were isolated, placed in skinning solution, and stored at -20 C until studied. Single fibers were isolated and placed between a motor arm and force transducer, functional properties were studied, and fiber protein content was subsequently analyzed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Additional fibers were isolated from soleus of control after 1 and 3 wk of HS, and fiber type distribution and myosin light chain stoichiometry were determined from SDS-PAGE analysis. After 1 wk of HS, percent type I fibers declined from 82 to 74%, whereas hybrid fibers increased from 10 to 18%. Percent fast type II fibers increased from 8% in control and 1 wk of HS to 26% by 3 wk of HS. Most fibers showed an increased unloaded maximal shortening velocity (V sub O)), but myosin heavy chain remained entirely slow type I. The mechanism for increased V(sub O) is unknown. There was a progressive decrease in fiber diameter and peak force after 1, 2, and 3 wk of HS, respectively. One week of HS resulted in a shift of the force-velocity curve, and between 2 and 3 wk of HS the curve shifted further such that V(sub O) was higher than control at all relative loads less than 45% peak isometric force. Peak absolute power output of soleus fibers progressively decreased through 2 wk of HS but showed no further change at 3 wk. The results suggest that between 2 and 3 wk the HS-induced alterations in the force-velocity relationship act to maintain the power output of single soleus fibers despite a continued reduction in fiber force.

Mcdonald, K. S.

Force-Velocity and Power Characteristics of Rat Soleus Muscle Fibers after Hindlimb Suspension

The effects of 1, 2, and 3 wk of Hindlimb Suspension (HS) on force-velocity and power characteristics of single rat soleus fibers were determined. After 1, 2, or 3 wk of HS, small fiber bundles were isolated, placed in skinning solution, and stored at -20 C until studied. Single fibers were isolated and placed between a motor arm and force transducer, functional properties were studied, and fiber protein content was subsequently analyzed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Additional fibers were isolated from soleus of control and after 1 and 3 wk of HS, and fiber type distribution and myosin light chain stoichiometry were determined from SDS-PAGE analysis. After 1 wk of HS, percent type I fibers declined from 82 to 74%, whereas hybrid fibers increased from 10 to 18%. Percent fast type 11 fibers increased from 8% in control and 1 wk of HS to 26% by 3 wk of HS. Most fibers showed an increased unloaded maximal shortening velocity (V(sub 0)), but myosin heavy chain remained entirely slow type I. The mechanism for increased V(sub 0) is unknown. There was a progressive decrease in fiber diameter (14, 30, and 38%) and peak force (38, 56, and 63%) after 1, 2, and 3 wk of HS, respectively. One week of HS resulted in a shift of the force-velocity curve, and between 2 and 3 wk of HS the curve shifted further such that V(sub 0) was higher than control at all relative loads less than 45% peak isometric force. Peak absolute power output of soleus fibers progressively decreased through 2 wk of HS but showed no further change at 3 wk. The results suggest that between 2 and 3 wk the HS-induced alterations in the force-velocity relationship act to maintain the power output of single soleus fibers despite a continued reduction in fiber force.

McDonald, K. S.

Experimental Investigation of Ice Phase Change Material Heat Exchangers

Phase change materials (PCM) may be useful for spacecraft thermal control systems that involve cyclical heat loads or cyclical thermal environments. Thermal energy can be stored in the PCM during peak heat loads or in adverse thermal environments. The stored thermal energy can then be released later during minimum heat loads or in more favorable thermal environments. This can result in a decreased turndown ratio for the radiator and a reduced system mass. The use of water as a PCM rather than the more traditional paraffin wax has the potential for significant mass reduction since the latent heat of formation of water is approximately 70% greater than that of wax. One of the potential drawbacks of using ice as a PCM is its potential to rupture its container as water expands upon freezing. In order to develop a space qualified ice PCM heat exchanger, failure mechanisms must first be understood. Therefore, a methodical experimental investigation has been undertaken to demonstrate and document specific failure mechanisms due to ice expansion in the PCM. A number of ice PCM heat exchangers were fabricated and tested. Additionally, methods for controlling void location in order to reduce the risk of damage due to ice expansion were investigated. This paper presents an overview of the results of this investigation from the past three years.

Leimkuehler, Thomas O.

Experimental Investigation of Ice Phase Change Material Heat Exchangers

Phase change materials (PCM) may be useful for spacecraft thermal control systems that involve cyclical heat loads or cyclical thermal environments. Thermal energy can be stored in the PCM during peak heat loads or in adverse thermal environments. The stored thermal energy can then be released later during minimum heat loads or in more favorable thermal environments. This can result in a decreased turndown ratio for the radiator and a reduced system mass. The use of water as a PCM rather than the more traditional paraffin wax has the potential for significant mass reduction since the latent heat of formation of water is approximately 70% greater than that of wax. One of the potential drawbacks of using ice as a PCM is its potential to rupture its container as water expands upon freezing. In order to develop a space qualified ice PCM heat exchanger, failure mechanisms must first be understood. Therefore, a methodical experimental investigation has been undertaken to demonstrate and document specific failure mechanisms due to ice expansion in the PCM. A number of ice PCM heat exchangers were fabricated and tested. Additionally, methods for controlling void location in order to reduce the risk of damage due to ice expansion were investigated. This paper presents an overview of the results of this investigation from the past three years.

Leimkuehler, Thomas O.

Active control of nonlinear-nonstationary response and radiation of a panel-stringer structure near a supersonic jet

This paper is on the control of nonlinear-nonstationary vibration of an aircraft-type frame-stringer structure and the acoustic radiation resulting from high levels of excitation by a nearby supersonic model jet exhaust. The objective of the control is to reduce the acoustic fatigue and the interior noise in a high-speed aircraft. Control of the structural response is achieved by actively forcing the structure with an actuator at the shock oscillation frequency whose amplitude is locked into a self-control cycle. This controller follows the amplitude modulation that results from the rotation and counter-rotation of the jet column. Results show that the peak level of the power in the structural response due to shock impingement is reduced by a factor of 63, corresponding to a power level reduction of 18 dB. As a result, new broadband components emerge with at least four harmonics contributing to the broadening of the response spectrum. At accelerating and decelerating supersonic speeds, the exhaust from the jet induces higher transient loading on the nearby flexible structure due to the occurrence of multiple shocks from the jet.

Maestrello, Lucio