Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peak load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A Momentum-Based Indicator for Predicting the Peak Opening Load of Supersonic Parachutes

In this paper, a new empirical indicator for predicting the peak opening loads of supersonic parachutes is presented. The proposed indicator is proportional to twice the free-stream dynamic pressure and the projected area of the parachute, which is equivalent to estimating the opening load as a percentage of the free-stream momentum flux through the projected area at the moment of peak inflation. The form of this expression is motivated by a classical control volume analysis of the aerodynamic forces acting on a parachute during inflation, under the simplifying assumptions of quasi-static and one-dimensional flow. For parachute geometries and flight conditions typical of Mars Entry, Descent, and Landing systems, the largest contribution to the total drag is shown to be a momentum flux term that is associated with the entrainment of atmosphere within the inflating parachute volume. Using this new method, empirical constants are calculated from existing flight reconstruction data and are shown to have a smaller standard deviation than similar constants determined using the customary indicator form, which is based on the steady-state subsonic drag and proportional to the parachute reference area. These empirical constants are also compared to an analytic estimate, derived from the control volume analysis, and shown to have excellent agreement across a wide range of Mach numbers and dynamic pressures for several parachute geometries. While opening loads estimated using both methods produce similar results at low supersonic Mach numbers typical of past inflations, the proposed method predicts notably larger loads at higher Mach numbers, those above Mach 2.0, due to the omission of any Mach Efficiency Factor. Several current Mars EDL projects have adopted this new indicator.

Way, David W.↗

Climate Change Impacts on Residential and Commercial Loads in the Western U.S. Grid

This report presents a multi-disciplinary modeling approach to quickly quantify climate change impacts on energy consumption, peak load, and load composition of residential and commercial buildings. This research focuses on addressing the impact of temperature changes on the building cooling load in 10 major cities across the Western United States and Canada. Our results have shown that by the mid-century, building yearly energy consumption and peak load will increase in the Southwest. Moreover, the peak load months will spread out to not only the summer months but also spring and autumn months. The Pacific Northwest will experience more hot days in the summer months. The penetration of the air conditioning (a/c) system in this area is likely to increase significantly over the years. As a result, some locations in the Pacific Northwest may be shifted from winter peaking to summer peaking. Overall, the Western U.S. grid may see more simultaneous peaks across the North and South in summer months. Increased cooling load will result in a significant increase in the motor load, which consumes more reactive power and requires stronger voltage support from the grid. This study suggests an increasing need for the industry to implement new technology to increase the efficiency of temperature-sensitive loads and apply proper protection and control to prevent possible adverse impacts of a/c motor loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Climate Change Impacts on Residential and Commercial Loads in the Western U.S. Grid

Abstract—This paper presents a multi-disciplinary modeling approach to quickly quantify climate change impacts on energy consumption, peak load, and load composition of residential and commercial buildings. This research focuses on addressing the impact of temperature changes on the building cooling load in 10 major cities across the Western United States and Canada. Our results have shown that by the mid-century, building yearly energy consumption and peak load will increase in the Southwest. Moreover, the peak load months will spread out to not only the summer months but also spring and autumn months. The Pacific Northwest will experience more hot days in the summer months. The penetration of the air conditioning (a/c) system in this area is likely to increase significantly over the years. As a result, some locations in the Pacific Northwest may be shifted from winter peaking to summer peaking. Overall, the Western U.S. grid may see more simultaneous peaks across the North and South in summer months. Increased cooling load will result in a significant increase in the motor load, which consumes more reactive power and requires stronger voltage support from the grid. This study suggests an increasing need for the industry to implement new technology to increase the efficiency of temperature-sensitive loads and apply proper protection and control to prevent possible adverse impacts of a/c motor loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Material Variability Effects on Damage Development Within Composite Adhesively Bonded Joints

Use of composite adhesively bonded joints (ABJ) is of critical importance to the adoption of composite materials in the automotive industry, as ABJ enable lower stress concentrations as compared to conventional mechanically fastened joints. ABJ are better suited for joining composite materials as compared to fastened joints because fastened joints require drilling of holes which locally affect composite material structure. Composite materials and adhesives are subject to unavoidable stochastic local material variations which make different failure scenarios possible. An experimentally tested ABJ configuration is simulated using finite element analysis (FEA). Experimentally, under tension, the joints failed by three major failure modes, with peak loads ranging from 13.0-16.1 kips. Progressive failure analysis tools are used to simulate damage development within each material within the joint. The simulation agreed well with the average experimental peak load. Stochastically occurring adhesive porosity and matrix-fiber micro-disbonding were numerically simulated. The simulations revealed a similar trend as observed experimentally: joints which failed at higher peak loads had lower levels of damage within the face-sheets of the composite panels which were adhesively bonded; these joints which failed at higher peak loads also had greater damage in the doubler of the experimentally tested double lap joint configuration.

Richard Larson↗

Load summary table for all sites

Summary peak load for all analyzed sites as part of study. The results are presented in 5 year increments

24 POWER TRANSMISSION AND DISTRIBUTION↗

NREL's Energy-Saving Technology for Air Conditioning Cuts Peak Power Loads Without Using Harmful Refrigerants (Fact Sheet)

This fact sheet describes how the DEVAP air conditioner was invented, explains how the technology works, and why it won an R&D 100 Award. Desiccant-enhanced evaporative (DEVAP) air-conditioning will provide superior comfort for commercial buildings in any climate at a small fraction of the electricity costs of conventional air-conditioning equipment, releasing far less carbon dioxide and cutting costly peak electrical demand by an estimated 80%. Air conditioning currently consumes about 15% of the electricity generated in the United States and is a major contributor to peak electrical demand on hot summer days, which can lead to escalating power costs, brownouts, and rolling blackouts. DEVAP employs an innovative combination of air-cooling technologies to reduce energy use by up to 81%. DEVAP also shifts most of the energy needs to thermal energy sources, reducing annual electricity use by up to 90%. In doing so, DEVAP is estimated to cut peak electrical demand by nearly 80% in all climates. Widespread use of this cooling cycle would dramatically cut peak electrical loads throughout the country, saving billions of dollars in investments and operating costs for our nation's electrical utilities. Water is already used as a refrigerant in evaporative coolers, a common and widely used energy-saving technology for arid regions. The technology cools incoming hot, dry air by evaporating water into it. The energy absorbed by the water as it evaporates, known as the latent heat of vaporization, cools the air while humidifying it. However, evaporative coolers only function when the air is dry, and they deliver humid air that can lower the comfort level for building occupants. And even many dry climates like Phoenix, Arizona, have a humid season when evaporative cooling won't work well. DEVAP extends the applicability of evaporative cooling by first using a liquid desiccant-a water-absorbing material-to dry the air. The dry air is then passed to an indirect evaporative cooling stage, in which the incoming air is in thermal contact with a moistened surface that evaporates the water into a separate air stream. As the evaporation cools the moistened surface, it draws heat from the incoming air without adding humidity to it. A number of cooling cycles have been developed that employ indirect evaporative cooling, but DEVAP achieves a superior efficiency relative to its technological siblings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A hybrid building thermal modeling approach for predicting temperatures in typical, detached, two-story houses

Within the residential building sector, the air-conditioning (AC) load is the main target for peak load shifting and reduction since it is the largest contributor to peak demand. By leveraging its power flexibility, residential AC is a good candidate to provide building demand response and peak load shifting. For realization of accurate and reliable control of AC loads, a building thermal model, which characterizes the properties of a building’s envelope and its thermal mass, is an essential component for accurate indoor temperature or cooling/heating demand prediction. Building thermal models include two types: “Forward” and “Data-Driven”. Due to time-saving and cost-effective characteristics, different data-driven models have been developed in a number of research studies. However, few developed models can predict temperatures in respective zones of a multiple-zone building with an open air path between zones e.g., an open stairwell connecting two floors of a home. In this research, a novel hybrid modeling approach is proposed to predict the average indoor air temperatures of both the upstairs and downstairs. This “hybrid” solution integrates both gray-box, i.e. RC model and black-box models. A developed RC model is used to predict the building mean temperature, and black-box model, in which the supervised machine learning algorithms are leveraged, is used to predict the temperature difference between the downstairs and upstairs. Compared with the measured data from a real house, the results obtained have acceptable/satisfactory accuracy. The method proposed in this study integrates the advantages of black-box and gray-box modeling. As a result, it can be used as a reliable alternative to predict the average temperatures in respective floors of typical detached two-story houses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

COHORT: Coordination of Heterogeneous Thermostatically Controlled Loads for Demand Flexibility

Demand flexibility is increasingly important for power grids. Careful coordination of thermostatically controlled loads (TCLs) can modulate energy demand, decrease operating costs, and increase grid resiliency. We propose a novel distributed control framework for the Coordination Of HeterOgeneous Residential Thermostatically controlled loads (COHORT). COHORT is a practical, scalable, and versatile solution that coordinates a population of TCLs to jointly optimize a grid-level objective, while satisfying each TCL’s end-use requirements and operational constraints. To achieve that, we decompose the grid-scale problem into subproblems and coordi- nate their solutions to find the global optimum using the alternating direction method of multipliers (ADMM). The TCLs’ local problems are distributed to and computed in parallel at each TCL, making COHORT highly scalable and privacy-preserving. While each TCL poses combinatorial and non-convex constraints, we characterize these constraints as a convex set through relaxation, thereby making COHORT computationally viable over long planning horizons. After coordination, each TCL is responsible for its own control and tracks the agreed-upon power trajectory with its preferred strategy. In this work, we translate continuous power back to discrete on/off actuation, using pulse width modulation. COHORT is generalizable to a wide range of grid objectives, which we demonstrate through three distinct use cases: generation following, minimizing ramping, and peak load curtailment. In a notable experiment, we validated our approach through a hardware-in-the-loop simulation, including a real-world air conditioner (AC) controlled via a smart thermostat, and simulated instances of ACs modeled after real-world data traces. During the 15-day experimental period, COHORT reduced daily peak loads by an average of 12.5% and maintained comfortable temperatures.

demand response↗

Accelerating Improvements in the Energy Efficiency of Room Air Conditioners (RACs) in India: Potential, Cost-Benefit, and Policies (Interim Assessment)

Falling AC prices, increasing incomes, increasing urbanization, and high cooling requirements due to hot climate are all driving increasing uptake of Room Air Conditioners (RACs) in the Indian market. Air conditioning already comprises 40-60% of summer peak load in large metropolitan Indian cities such as Delhi and is likely to contribute 150 GW to the peak demand in 2030. Standards and labeling policies have contributed to improving the efficiency of RACs in India by about 2.5% in the last 10 years (2.5% per year) while inflation adjusted RAC prices have continued to decline. In this paper, we assess the technical feasibility, cost-benefit, and required policy enhancements by further accelerating the efficiency improvement of RACs in India. We find that there are examples of significantly more accelerated improvements such as those in Japan and Korea where AC efficiency improved by more than 7% per year resulting in almost a doubling of energy efficiency in 7 to 10 years while inflation adjusted AC prices continued to decline. We find that the most efficient RAC sold on the Indian market is almost twice as efficient as the typical AC sold on the market and hence see no technology constraints in a similar acceleration of improvement of efficiency. If starting 2018, AC efficiency improves at a rate of 6% instead of 3%, 40-60 GW of peak load (equivalent to connected load of 5-6 billion LED bulbs), and over 75 TWh/yr (equivalent to 60 million consumers consuming 100 kWh/month) will be saved by 2030; total peak load reduction would be as high as 50 GW. The net present value (NPV) of the consumer benefit between 2018-2030 will range from Rs 18,000 Cr in the most conservative case (in which prices don’t continue to decline and increase based estimates of today’s cost of efficiency improvement) to 140,000 Cr in a more realistic case (in which prices are not affected by accelerated efficiency improvement as shown by historical experience). This benefit is achievable by ratcheting up the 1 star level for fixed and inverter ACs to the level of today’s five star rating for inverter ACs by 2022. Bulk procurement (similar to the Domestic Efficient Lighting Program) and incentive programs can complement the accelerated ratcheting up of star levels. Similar programs can also be implemented for other types of ACs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A high-speed micro-impact testing system for evaluating the properties of lead-free solder joints

ConclusionThis study presents a novel high-speed micro-impact testing system for evaluating the shear strength and energy absorbance properties of lead-free solder ball joints under impact velocities of 0.3–1.0 m/s. The test method can examine the failure mode transition from ductile failure to brittle failure based on the failure mode distribution percentage. The load—displacement curves can distinguish between different failure modes. Notably, the values of peak load and the energy-to-peak load at various impact speeds can be used as indices for determining solder ball under impact loading conditions. Thus, the proposed method is a suitable technique for evaluating the mechanical response of solder ball joints used in typical semiconductor packages and, therefore, represents a simple and effective technique for optimizing the chip-level reliability of portable consumer electronic products.

36 MATERIALS SCIENCE↗

End-Use Savings Shapes Measure Documentation: Dispatch Schedule Generation for Demand Flexibility Measures

This supplemental document describes the methodology used for determining the dispatch timing of various EUSS demand flexibility measures. Demand flexibility measures are designed to reduce/dispatch electricity demand in buildings during especially beneficial/critical times. The method used in this work utilizes predictions of building loads to generate a schedule that reflects the periods when the building's daily peak load occurs to support decision making in demand flexibility measures. The dispatch schedule generation method described in this document creates an hourly schedule that includes a load dispatch (peak) window for each day for a whole year based on load prediction, with options using different prediction methods: perfect prediction, bin-sampling method, fixed schedule, and outdoor air temperature (OAT)-based prediction method. The perfect prediction method performs a simulation to obtain the annual load profile as predicted load, representing the scenario of perfect load prediction. The bin-sampling method (1) categorizes days into representative bins by temperature characteristics, (2) performs simulations on sample days from each of those bins to create representative (or predicted) load, and (3) assigns representative loads for all days in a year based on the bin categorization. The fixed schedule method defines uniform start and end time of peak window with assumed fixed daily peak time, for all days in a season or a year. The OAT-based prediction method uses the statistics of OAT (minimum and maximum) as the indicators of peak load, with specified delay response time from building loads to temperature. Given the load prediction, daily peak periods are determined as a time window with specified length in each day that include the predicted daily peak load and with a secondary rule such as maximizing energy saving potential. The dispatch schedule generation method is not a standalone measure and is intended to be combined with other demand flexibility measures that could leverage the peak schedule and apply demand controls on specific systems or devices for demand response, such as measures described in "Measure Documentation - Thermostat Control for Load Shedding" and "Measure Documentation - Thermostat Control for Load Shifting".

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use of Phase Change Material in a Building Wall Assembly: A Case Study of Technical Potential in Two Climates

Phase change material (PCM), placed in an exterior wall, alters the temperature profile within the wall and thus influences the heat transport through the wall. This may reduce the net energy transport through the wall via interactions with diurnal temperature swings in the external environment or reduce the electricity needed to meet the net load through the wall by shifting the time of the peak load to a time when the cooling system operates more efficiently. This study covers a broad range of parameters that can influence the effectiveness of such a merged thermal storage-thermal insulation system. These parameters included climate, PCM location within the wall, amount of PCM, midpoint of the PCM melting and freezing range relative to the indoor setpoint temperature, temperature range over which phase change occurs, and the wall orientation. Two climates are investigated using finite difference and optimization analyses: Phoenix and Baltimore, with two utility rate schedules. Although potential savings for a PCM with optimized properties were greater when the PCM was concentrated near the inside wall surface, other considerations described here lead to a recommendation for a full-thickness application. An examination of the temperature distribution within the walls also revealed the potential for this system to reduce the amount of energy transported through the wall framing. Finally, economic benefits can exceed energy savings when time-of-day utility rates are in effect, reflecting the value of peak load reductions for the utility grid.

36 MATERIALS SCIENCE↗

Potential Energy Savings Due to Phase Change Material in a Building Wall Assembly: An Examination of Two Climates

Phase change material (PCM), placed in an exterior wall, alters the temperature profile within the wall and thus influences the heat transport through the wall. This may reduce the net energy transport through the wall via interactions with diurnal temperature swings in the external environment or reduce the electricity needed to meet the net load through the wall by shifting the time of the peak load to a time when the cooling system operates more efficiently. This study covers a broad range of parameters that can influence the effectiveness of such a merged thermal storage-thermal insulation system. These parameters included climate, PCM location within the wall, amount of PCM, midpoint of the PCM melting and freezing range relative to the indoor setpoint temperature, temperature range over which phase change occurs, and the wall orientation. Two climates are investigated using finite difference and optimization analyses: Phoenix and Baltimore, with two utility rate schedules. Although potential savings for a PCM with optimized properties were greater when the PCM was concentrated near the inside wall surface, other considerations described here lead to a recommendation for a full-thickness application. An examination of the temperature distribution within the walls also revealed the potential for this system to reduce the amount of energy transported through the wall framing. Finally, economic benefits can exceed energy savings when time-of-day utility rates are in effect, reflecting the value of peak load reductions for the utility grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

American-Made Challenges Round 2 Voucher: Orison Enables Solar

This report documents the technical assistance provided to Orison as part of the American-Made Challenges Round 2 Voucher: Orison Enables Solar project. A testbed was developed and used to demonstrate, using modeling and simulation, the capability of controlled behind-the-meter energy storage to (1) reduce net load variability caused by appliances and distributed generation and (2) enable customers to respond to the time-of-use pricing. We demonstrate that load leveling can shave peak loads or limit solar photovoltaic export and that load shifting enables customers to reduce load during “peak” pricing intervals. In the scenarios that we simulated, load leveling was effective up to the charging and discharging limits of the storage systems and the effectiveness of load shifting was a function of the energy capacity of the storage systems. This report describes the co-simulation testbed and the scenarios simulated, including controller setup and simulation results. Considerations for a multi-objective controller are also discussed.

14 SOLAR ENERGY↗

Multi-State Load Models for Distribution System Analysis

Recent work in the field of distribution system analysis has shown that the traditional method of peak load analysis is not adequate for the analysis of emerging distribution system technologies. Voltage optimization, demand response, electric vehicle charging, and energy storage are examples of technologies with characteristics having daily, seasonal, and/or annual variations. In addition to the seasonal variations, emerging technologies such as demand response and plug in electric vehicle charging have the potential to send control signals to the end use loads which will affect how they consume energy. In order to support time-series analysis over different time frames and to incorporate potential control signal inputs it is necessary to develop detailed end use load models which accurately represent the load under various conditions, and not just during the peak load period. This paper will build on previous work on detail end use load modeling in order to outline the method of general multi-state load models for distribution system analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validation of Floating Node Method Using Three-Point Bend Doubler Under Quasi-Static Loading

The NASA Advanced Composite Project (ACP), an industry/government/university partnership, has embarked upon the task of developing technology that can aid in reducing the time line for structural certification of aircraft composite parts using a combination of technologies, one of which is high fidelity damage progression computational methods. Phase II of this project included a task for validating an approach based on the Floating Node Method combined with Directional Cohesive Elements (FNM-DCZE). This paper discusses predicted damage onset and growth in a three-point bend doubler specimen compared to experimental results. Sensitivity of the simulations to mesh refinement as well as key material properties and thermal effects are studied and reported. Overall, qualitative results suggest the main aspects of the damage progression have been captured, with the simulated damage morphology and sequence of events resembling closely what was observed experimentally. Quantitatively, the first load-peak is predicted. However, the re-loading observed in the experiments, after the first load peak, is not captured numerically, suggesting further investigation may be worth pursuing.

Selvarathinam, Alex S.↗

Bridging the gap between peak and average loads on science networks

Backbone networks are typically overprovisioned in order to support peak loads. Research and education networks (RENs), for example, are often designed to operate at 20–30% of capacity. Thus, Internet2 upgrades its backbone interconnects when the weekly 95th-percentile load is reliably above 30% of link capacity, and analysis of ESnet traffic between major laboratories shows a substantial gap between peak and average utilization. As science data volumes increase exponentially, it is unclear whether this overprovisioning trend can continue into the future. Even if overprovisioning is possible, it may not be the most cost-effective (and desirable) approach going forward. Under the current mode of free access to RENs, traffic at peak load may include both flows that need to be transferred in near-real time–for example, for computation and instrument monitoring and steering–and flows that are less time-critical, for example, archival and storage replication operations. Thus, peak load does not necessarily indicate the capacity that is absolutely required at that moment. We thus examine how data transfers are impacted when the average network load is increased while the network capacity is kept at the current levels. We also classify data transfers into on-demand (time-critical) and best-effort (less time-critical) and study the impact on both classes for different proportions of both the number of on-demand transfers and amount of bandwidth allocated for on-demand transfers. For our study, we use real transfer logs from production GridFTP servers to do simulation-based experiments as well as real experiments on a testbed. We find that when the transfer load is doubled and the network capacity is fixed at the current level, the gap between peak and average throughput decreases by an average of 18% in the simulation experiments and 16% in the testbed experiments, and the average slowdown experienced by the data transfers is under 1.5×. Moreover, when transfers are classified as on-demand or best-effort, on-demand transfers experience almost no slowdown and the mean slowdown experienced by best-effort transfers is under 2× in the simulation experiments and under 1.2× in the testbed experiments.

97 MATHEMATICS AND COMPUTING↗

Calculation of the longitudinal aerodynamic characteristics of wing-flap configurations with externally blown flaps

A theoretical investigation was carried out to extend and improve an existing method for predicting the longitudinal characteristics of wing flap configurations with externally blown flaps (EBF). Two potential flow models were incorporated into the prediction method: a wing and flap lifting-surface model and a turbofan engine wake model. The wing-flap model uses a vortex-lattice approach to represent the wing and flaps. The jet wake model consists of a series of closely spaced vortex rings normal to a centerline which may have vertical and lateral curvature to conform to the local flow field beneath the wing and flaps. Comparisons of measured and predicted pressure distributions, span load distributions on each lifting surface, and total lift and pitching moment coefficients on swept and unswept EBF configurations are included. A wide range of thrust coefficients and flap deflection angles is considered at angles of attack up to the onset of stall. Results indicate that overall lift and pitching-moment coefficients are predicted reasonably well over the entire range. The predicted detailed load distributions are qualitatively correct and show the peaked loads at the jet impingement points, but the widths and heights of the load peaks are not consistently predicted.

Mendenhall, M. R.↗