Preventing Molecular and Particulate Infiltration in a Confined Volume

Contaminants from an instrument's self-generated sources or from sources external to the instrument may degrade its critical surfaces and/or create an environment which limits the instrument's intended performance. Analyses have been carried out on a method to investigate the required purging flow of clean, dry gas to prevent the ingestion of external contaminants into the instrument container volume. The pressure to be maintained and the required flow are examined in terms of their effectiveness in preventing gaseous and particulate contaminant ingestion and abatement of self-generated contaminants in the volume. The required venting area or the existing volume venting area is correlated to the volume to be purged, the allowable pressure differential across the volume, the external contaminant partial pressure, and the sizes of the ambient particulates. The diffusion of external water vapor into the volume while it was being purged was experimentally obtained in terms of an infiltration time constant. That data and the acceptable fraction of the outside pressure into the volume indicate the required flow of purge gas expressed in terms of volume change per unit time. The exclusion of particulates is based on the incoming velocity of the particles and the exit flow speed and density of the purge gas. The purging flow pressures needed to maintain the required flows through the vent passages are indicated. The purge gas must prevent or limit the entrance of the external contaminants to the critical locations of the instrument. It should also prevent self- contamination from surfaces, reduce material outgassing, and sweep out the outgassed products. Systems and facilities that can benefit from purging may be optical equipment, clinical facilities, manufacturing facilities, clean rooms, and other systems requiring clean environments.

Scialdone, John J.↗

Aerosols and Particulates Workshop Sampling Procedures and Venues Working Group Summary

The Sampling Procedures and Venues Workgroup discussed the potential venues available and issues associated with obtaining measurements. Some of the issues included Incoming Air Quality, Sampling Locations, Probes and Sample Systems. The following is a summary of the discussion of the issues and venues. The influence of inlet air to the measurement of exhaust species, especially trace chemical species, must be considered. Analysis procedures for current engine exhaust emissions regulatory measurements require adjustments for air inlet humidity. As a matter of course in scientific investigations, it is recommended that "background" measurements for any species, particulate or chemical, be performed during inlet air flow before initiation of combustion, if possible, and during the engine test period as feasible and practical. For current regulatory measurements, this would be equivalent to setting the "zero" level for conventional gas analyzers. As a minimum, it is recommended that measurements of the humidity and particulates in the incoming air be taken at the start and end of each test run. Additional measurement points taken during the run are desirable if they can be practically obtained. It was felt that the presence of trace gases in the incoming air is not a significant problem. However, investigators should consider the ambient levels and influences of local air pollution for species of interest. Desired measurement locations depend upon the investigation requirements. A complete investigation of phenomenology of particulate formation and growth requires measurements at a number of locations both within the engine and in the exhaust field downstream of the nozzle exit plane. Desirable locations for both extractive and in situ measurements include: (1) Combustion Zone (Multiple axial locations); (2) Combustor Exit (Multiple radial locations for annular combustors); (3) Turbine Stage (Inlet and exit of the stage); (4) Exit Nozzle (Multiple axial locations downstream of the nozzle). Actual locations with potential for extractive or non-intrusive measurements depend upon the test article and test configuration. Committee members expressed the importance of making investigators aware of various ports that could allow access to various stages of the existing engines. Port locations are engine si)ecific and might allow extractive sampling or innovative hybrid optical-probe access. The turbine stage region was one the most desirable locations for obtaining samples and might be accessed through boroscope ports available in some engine designs. Discussions of probes and sampling systems quickly identified issues dependent on particular measurement quantities. With general consensus, the group recommends SAE procedures for measurements and data analyses of currently regulated exhaust species (CO2, CO, THC, NO(x),) using conventional gas sampling techniques. Special procedures following sound scientific practices must be developed as required for species and/or measurement conditions not covered by SAE standards. Several issues arose concerning short lived radicals and highly reactive species. For conventional sampling, there are concerns of perturbing the sample during extraction, line losses, line-wall reactions, and chemical reactions during the sample transport to the analyzers. Sample lines coated with quartz.or other materials should be investigated for minimization of such effects. The group advocates the development of innovative probe techniques and non-intrusive optical techniques for measurement of short lived radicals and highly reactive species that cannot be sampled accurately otherwise. Two innovative probe concepts were discussed. One concept uses specially designed probes to transfer optical beams to and from a region of flow inaccessible by traditional ports or windows. The probe can perturb the flow field but must have a negligible impact on the region to be optically sampled. Such probes are referred to as hybrid probes and are under development at AEDC for measurement in the high pressure, high temperature of a combustor under development for power generation. The other concept consists of coupling an instrument directly to the probe. The probe would isolate a representative sample stream, freeze chemical reactions and direct the sample into the analyzer portion of the probe. Thus, the measurement would be performed in situ without sample line losses due either to reactions or binding at the wall surfaces. This concept was used to develop a fast, in situ, time-of-flight mass spectrometer measurement system for temporal quantification of NO in the IMPULSE facility at AEDC. Additional work is required in this area to determine the best probe and sampling technique for each species measurement requirement identified by the Trace Chemistry Working Group. A partial list of Venues was used as a baseline for discussion. Additional venues were added to the list and the list was broken out into the following categories: (1)Engines (a) Sea Level Test Stands (b) Altitude Chambers; (2) Annular Combustor Test Stands, (3) Sector Flametube Test Stands, (4) Fundamentals Rigs/Experiments.

Pachlhofer, Peter↗

Bidirectional Reflectance of a Macroscopically Flat, High-Albedo Particulate Surface: An Efficient Radiative Transfer Solution and Applications to Regoliths

Many remote sensing applications rely on accurate knowledge of the bidirectional reflection function (BRF) of surfaces composed of discrete, randomly positioned scattering particles. Theoretical computations of BRFs for plane-parallel particulate layers are usually reduced to solving the radiative transfer equation (RTE) using one of existing exact or approximate techniques. Since semi-empirical approximate approaches are notorious for their low accuracy, violation of the energy conservation law, and ability to produce unphysical results, the use of numerically exact solutions of RTE has gained justified popularity. For example, the computation of BRFs for macroscopically flat particulate surfaces in many geophysical publications is based on the adding-doubling (AD) and discrete ordinate (DO) methods. A further saving of computer resources can be achieved by using a more efficient technique to solve the plane-parallel RTE than the AD and DO methods. Since many natural particulate surfaces can be well represented by the model of an optically semi-infinite, homogeneous scattering layer, one can find the BRF directly by solving the Ambartsumian's nonlinear integral equation using a simple iterative technique. In this way, the computation of the internal radiation field is avoided and the computer code becomes highly efficient and very accurate and compact. Furthermore, the BRF thus obtained fully obeys the fundamental physical laws of energy conservation and reciprocity. In this paper, we discuss numerical aspects and the computer implementation of this technique, examine the applicability of the Henyey-Greenstein phase function and the sigma-Eddington approximation in BRF and flux calculations, and describe sample applications demonstrating the potential effect of particle shape on the bidirectional reflectance of flat regolith surfaces. Although the effects of packing density and coherent backscattering are currently neglected, they can also be incorporated. The FORTRAN implementation of the technique is available on the World Wide Web, and can be applied to a wide range of remote sensing problems. BRF computations for undulated (macroscopically rough) surfaces are more complicated and often rely on time consuming Monte Carlo procedures. This approach is especially inefficient for optically thick, weakly absorbing media (e.g., snow and desert surfaces at visible wavelengths since a photon may undergo many internal scattering events before it exists the medium or is absorbed. However, undulated surfaces can often be represented as collections of locally flat tilted facets characterized by the BRF found from the traditional plane parallel RTE. In this way the MOnte Carlo procedure could be used only to evaluate the effects of surface shadowing and multiple surface reflections, thereby bypassing the time-consuming ray tracing inside the medium and providing a great savings of CPU time.

Mishchenko, Michael I.↗

"Smoke": Characterization Of Smoke Particulate For Spacecraft Fire Detection

The "Smoke" experiment is a flight definition investigation that seeks to increase our understanding of spacecraft fire detection through measurements of particulate size distributions of preignition smokes from typical spacecraft materials. Owing to the catastrophic risk posed by even a very small fire in a spacecraft, the design goal for spacecraft fire detection is to detect the fire as quickly as possible, preferably in the preignition phase before a real flaming fire has developed. Consequently the target smoke for detection is typically not soot (typical of established hydrocarbon fires) but instead, pyrolysis products, and recondensed polymer particles. At the same time, false alarms are extremely costly as the crew and the ground team must respond quickly to every alarm. The U.S. Space Shuttle (STS: Space Transportation System) and the International Space Station (ISS) both use smoke detection as the primary means of fire detection. These two systems were designed in the absence of any data concerning low-gravity smoke particle (and background dust) size distributions. The STS system uses an ionization detector coupled with a sampling pump and the ISS system is a forward light scattering detector operating in the near IR. These two systems have significantly different sensitivities with the ionization detector being most sensitive (on a mass concentration basis) to smaller particulate and the light scattering detector being most sensitive to particulate that is larger than 1 micron. Since any smoke detection system has inherent size sensitivity characteristics, proper design of future smoke detection systems will require an understanding of the background and alarm particle size distributions that can be expected in a space environment.

Urban, David L.↗

Uncertainties in the Thermal and Mechanical Properties of Particulate Composites Quantified

Particle-reinforced composites are candidate materials for a wide variety of aerospace and nonaerospace applications. The high costs and technical difficulties involved with the use of many fiber-reinforced composites often limit their use in many applications. Consequently, particulate composites have emerged as viable alternatives to conventional fiber-reinforced composites. Particulate composites can be processed to near net shapepotentially reducing the manufacturing costs. They are candidate materials where shock or impact properties are important. For example, particle-reinforced metal matrix composites have shown great potential for many automotive applications. Typically, these materials are aluminum matrix reinforced with SiC or TiC particles. Reinforced concrete can also be thought of as a particle-reinforced composite. In situ ceramics can be modeled as particulate composites and are candidate materials for many high-temperature applications. The characterization of these materials is fundamental to their reliable use. It has been observed that the overall properties of these composites exhibit scatter because of the uncertainty in the constituent material properties, and fabrication-related parameters.

Murthy, Pappu L. N.↗

Method and Apparatus for the Quantification of Particulate Adhesion Forces on Various Substrates

Mitigation strategies for lunar dust adhesion have typically been limited to qualitative analysis. This technical memorandum describes the generation and operation of an adhesion testing device capable of quantitative assessment of adhesion forces between particulates and substrates. An aerosolization technique is described to coat a surface with a monolayer of particulates. Agitation of this surface, via sonication, causes particles to dislodge and be gravitationally fed into an optical particle counter. Experimentally determined adhesion force values are compared to forces calculated from van der Waals interactions and are used to calculate the work of adhesion using Johnson-Kendall-Roberts (JKR) theory. Preliminary results indicate that a reduction in surface energy and available surface area, through topographical modification, improve mitigation of particulate adhesion.

Wohl, Christopher J.↗

Development of Test Protocols for International Space Station Particulate Filters

Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High-Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. The filter element for this system has a non-standard cross-section with a length-to-width ratio (LW) of 6.6. A filter test setup was designed and built to meet industry testing standards. A CFD analysis was performed to initially determine the optimal duct geometry and flow configuration. Both a screen and flow straighter were added to the test duct design to improve flow uniformity and face velocity profiles were subsequently measured to confirm. Flow quality and aerosol mixing assessments show that the duct flow is satisfactory for the intended leak testing. Preliminary leak testing was performed on two different ISS filters, one with known perforations and one with limited use, and results confirmed that the testing methods and photometer instrument are sensitive enough to detect and locate compromised sections of an ISS BFE.Given the engineering constraints in designing spacecraft life support systems, it is anticipated that non-industry standard filters will be required in future designs. This work is focused on developing test protocols for testing the ISS BFE filters, but the methodology is general enough to be extended to other present and future spacecraft filters. These techniques for characterizing the test duct and perform leak testing can be applied to conducting acceptance testing and inventory testing for future manned exploration programs with air revitalization filtration needs, possibly even for in-situ filter element integrity testing for extensively long-duration missions. We plan to address the unique needs for test protocols for crewed spacecraft particulate filters by preparing the initial version of a standard, to be documented as a NASA Technical Memorandum (TM).

Filtration↗

Evolution of the Lunar Receiving Laboratory to the Astromaterial Sample Curation Facility: Technical Tensions Between Containment and Cleanliness, Between Particulate and Organic Cleanliness

The Lunar Receiving Laboratory (LRL) was planned and constructed in the 1960s to support the Apollo program in the context of landing on the Moon and safely returning humans. The enduring science return from that effort is a result of careful curation of planetary materials. Technical decisions for the first facility included sample handling environment (vacuum vs inert gas), and instruments for making basic sample assessment, but the most difficult decision, and most visible, was stringent biosafety vs ultra-clean sample handling. Biosafety required handling of samples in negative pressure gloveboxes and rooms for containment and use of sterilizing protocols and animal/plant models for hazard assessment. Ultra-clean sample handling worked best in positive pressure nitrogen environment gloveboxes in positive pressure rooms, using cleanable tools of tightly controlled composition. The requirements for these two objectives were so different, that the solution was to design and build a new facility for specific purpose of preserving the scientific integrity of the samples. The resulting Lunar Curatorial Facility was designed and constructed, from 1972-1979, with advice and oversight by a very active committee comprised of lunar sample scientists. The high precision analyses required for planetary science are enabled by stringent contamination control of trace elements in the materials and protocols of construction (e.g., trace element screening for paint and flooring materials) and the equipment used in sample handling and storage. As other astromaterials, especially small particles and atoms, were added to the collections curated, the technical tension between particulate cleanliness and organic cleanliness was addressed in more detail. Techniques for minimizing particulate contamination in sample handling environments use high efficiency air filtering techniques typically requiring organic sealants which offgas. Protocols for reducing adventitious carbon on sample handling surfaces often generate particles. Further work is needed to achieve both minimal particulate and adventitious carbon contamination. This paper will discuss these facility topics and others in the historical context of nearly 50 years' curation experience for lunar rocks and regolith, meteorites, cosmic dust, comet particles, solar wind atoms, and asteroid particles at Johnson Space Center.

Allton, J. H.↗

A Comparison of Near Simultaneous Lidar Returns and Particulate Collections on Filters Flown at Six Stratospheric Altitudes

Collections of particulates on both Los Alamos Scientific Laboratory (LASL) and National Center for Atmospheric Research (NCAR) filter systems were made from an RB 57F aircraft flown at one tropospheric and six stratospheric altitudes over the Boulder, Colorado, area. This daytime flight was spanned by lidar returns on evenings before and after the flight. Scanning electron microscope examination of the LASL filters showed no evidence of solid particulates greater than 2 micrometers (the instrumental resolving power). Quantitative analysis of the NCAR filters yielded chemical composition and mass. The mass values were normalized to the total air flow through the filters to yield mass mixing ratios at the various altitudes. The lidar returns, normalized to molecular densities obtained from sonde data, were put in the form of particulate scattering divided by molecular scattering, i. e., an optical mixing ratio. A plot of the optical mixing ratio versus mass mixing ratio, in the stratosphere, yielded linear relationship, for five of the six data points, going through the origin.

Schuster, Burton G.↗

Filtration of Carbon Particulate Emissions from a Plasma Pyrolysis Assembly

NASA is investigating plasma pyrolysis as a candidate technology that will enable the recovery of hydrogen from the methane produced by the ISS Sabatier Reactor. The Plasma Pyrolysis Assembly (PPA) is the current prototype of this technology which converts the methane product from the Carbon Dioxide Reduction Assembly (CRA) to acetylene and hydrogen with 90% or greater conversion efficiency. A small amount of solid carbon particulates are generated as a side product and must be filtered before the acetylene is removed and the hydrogen-rich gas stream is recycled back to the CRA. We discuss developmental work on several options for filtering out the carbon particulate emissions from the PPA exit gas stream. The filtration technologies and concepts investigated range from fibrous media to monolithic ceramic and sintered metal media. This paper describes the different developed filter prototypes and characterizes their performance from integrated testing at the Environmental Chamber (E-Chamber) at MSFC. In addition, characterization data on the generated carbon particulates, that help to define filter requirements, are also presented.

methane↗

Retrieval of Ocean Subsurface Particulate Backscattering Coefficient from Space-Borne CALIOP Lidar Measurement

A new approach has been proposed to determine ocean subsurface particulate backscattering coefficient bbp from CALIOP 30deg off-nadir lidar measurements. The new method also provides estimates of the particle volume scattering function at the 180deg scattering angle. The CALIOP based layer-integrated lidar backscatter and particulate backscattering coefficients are compared with the results obtained from MODIS ocean color measurements. The comparison analysis shows that ocean subsurface lidar backscatter and particulate backscattering coefficient bbp can be accurately obtained from CALIOP lidar measurements, thereby supporting the use of space-borne lidar measurements for ocean subsurface studies.

Lu, Xiaomei↗

Characterization and Measurement of Spacecraft Airborne Particulate Matter

The International Space Station (ISS) gives a 6-member astronaut crew the ability to live and work in low Earth orbit. It is a unique indoor environment, which has served as both home and workplace to over 230 people since the year 2000. In this low gravity environment, smoke does not rise and cookie crumbs do not settle the way they do on Earth, causing airborne particulate matter, or aerosols, to behave differently and pose unique hazards for crew members. In its existence, virtually the same volume of ISS air has been continuously conditioned and ‘revitalized,’ including the removal of particles by filtration. While gaseous constituents of ISS air are monitored meticulously, sparse data exists on the indoor aerosols. The quantity and types of ISS airborne debris have been investigated in NASA’s Aerosol Sampling Experiment. Both active and passive samplers successfully collected airborne particulate matter in U.S. segments of the ISS, which were returned to Earth for characterization by microscopy and other techniques. The resulting data has informed the design of candidate particle instruments for spacecraft. In 2020, a reference-quality aerosol instrument will be flown to ISS, and will provide real-time data of particle concentrations in various modules. Smaller, more compact instruments will be necessary in future space missions, for example, in smaller vehicles, in habitats on lunar and planetary surfaces with ubiquitous dust, and also for use as wearable technology throughout missions. Miniaturized aerosol sensors, though lower fidelity than reference-quality instruments, can monitor the environment well when calibrated appropriately. Indoor air quality in spacecraft is fundamentally important to human health and comfort, and several particulate monitoring technologies will be at sufficient technology readiness levels for operational use within the next two years. Results of the Aerosol Sampling Experiment will be presented, along with the status of NASA’s aerosol instrument technology demonstrations on ISS.

Meyer, Marit E.↗

Particulate filtration from emissions of a plasma pyrolysis assembly reactor using regenerable porous metal filters

Microwave-based plasma pyrolysis technology is being studied as a means of supporting oxygen recovery in future spacecraft life support systems. The process involves the conversion of methane produced from a Sabatier reactor to acetylene and hydrogen, with a small amount of solid carbon particulates generated as a side product. The particles must be filtered before the acetylene is removed and the hydrogen-rich gas stream is recycled back to the CRA. We discuss developmental work on porous metal media filters for removing the carbon particulate emissions from the PPA exit gas stream and to provide in situ media regeneration capability. Because of the high temperatures involved in oxidizing the deposited carbon during regeneration, there was particular focus in this development on the materials that could be used, the housing design, and heating methods. This paper describes the design and operation of the filter and characterizes their performance from integrated testing at the Environmental Chamber (E-Chamber) at MSFC.

particulates↗

Exploration Mission Particulate Matter Filtration Technology Performance Testing in a Simulated Spacecraft Cabin Ventilation System

Human deep space exploration missions will require advances in long-life, low maintenance airborne particulate matter filtration technology. As one of the National Aeronautics and Space Administrations (NASA) developments in this area, a prototype of a new regenerable, multi-stage particulate matter filtration technology was tested in an International Space Station (ISS) module simulation facility. As previously reported, the key features of the filter system include inertial and media filtration with regeneration and in-place media replacement techniques. The testing facility can simulate aspects of the cabin environment aboard the ISS and contains flight-like cabin ventilation system components. The filtration technology test article was installed at the inlet of the central ventilation system duct and instrumented to provide performance data under nominal flow conditions. In-place regeneration operations were also evaluated. The real-time data included pressure drop across the filter stages, process air flow rate, ambient pressure, humidity and temperature. In addition, two video cameras positioned at the filtration technology test articles inlet and outlet were used to capture the mechanical performance of the filter media indexing operation under varying air flow rates. Recent test results are presented and future design recommendations are discussed.

particulate matter filtration↗

Feasibility of using Low-Cost COTS Sensors for Particulate Monitoring in Space Missions

Real-time measurement of particles suspended in the spacecraft cabin is of great importance to verify that maximum allowable dust concentrations are not exceeded. This is primarily to protect astronaut health, but also has implications for dust-sensitive equipment. Recently, there is growing interest in low-cost commercial off-the-shelf (COTS) particle sensors by air quality researchers for their ability to map concentrations of airborne particulate matter in various terrestrial settings. In addition to low cost (< $2,000), the compact size and minimal weight of these sensors make them a potential choice for space missions. The detection mechanism for these aerosol sensors is typically measurement of light scattered by particles as they flow through a sensing volume. The amount of scattered light for detection depends on the particle size, shape, density, and refractive index of the particle material. Ideally, particle instruments should be calibrated with reference instruments for each different type of aerosol measurement. In this study we review multiple parameters that may impact the performance of state-of-the-art low-cost aerosol sensors. Environmental factors such as temperature, relative humidity, low ambient pressure, radiation and charge environment, partial-gravity and microgravity can affect the accuracy of particle measurements. Characteristics of the dust aerosols including particle size distribution, aerosol composition, refractive index, morphology and concentration levels also affect the measurement accuracy. Finally, we look at these parameters and issues with respect to an example COTS low-cost aerosol sensor. Instrument performance specifications are evaluated, and experiments are performed to measure real-time concentrations of Arizona Road Dust (a terrestrial reference test dust) and lunar dust simulant in a laboratory chamber. Overall, this study provides insight for evaluating spacecraft particulate monitoring technologies and raises questions to be answered before incorporating low-cost COTS sensors in future space missions to dusty destinations.

lunar dust↗

Premature Deaths in Africa Due to Particulate Matter Under High and Low Warming Scenarios

Sustainable development and climate change mitigation can provide enormous public health benefits via improved air quality, especially in polluted areas. We use the latest state-of-the-art composition-climate model simulations to contrast human exposure to fine particulate matter in Africa under a “baseline” scenario with high material consumption, population growth, and warming to that projected under a sustainability scenario with lower consumption, population growth, and warming. Evaluating the mortality impacts of these exposures, we find that under the low warming scenario annual premature deaths due to PM2.5 are reduced by roughly 515,000 by 2050 relative to the high warming scenario (100,000, 175,000, 55,000, 140,000, and 45,000 in Northern, West, Central, East, and Southern Africa, respectively). This reduction rises to ∼800,000 by the 2090s, though by that time much of the difference is attributable to the projected differences in population. By contrast, during the first half of the century benefits are driven predominantly by emissions changes. Depending on the region, we find large intermodel spreads of ∼25%–50% in projected future exposures owing to different physics across the ensemble of 6 global models. The spread of projected deaths attributable to exposure to fine particulate matter, including uncertainty in the exposure-response function, are reduced in every region to ∼20%–35% by the non-linear exposure-response function. Differences between the scenarios have an even narrower spread of ∼5%–25% and are highly statistically significant in all regions for all models. These results provide valuable information for policy-makers to consider when working toward climate change mitigation and sustainable development goals.

PM2.5↗

Particulate Emission and Optical Measurements in n-Heptane Low-Swirl Non-Premixed Flames at Elevated Pressures

A series of ground combustion tests conducted at elevated pressures demonstrates in-chamber optical measurements of soot emissions, combined with conventional gaseous and particle emissions sampling techniques. Utilizing a micro-radial-entry counter-swirl (MRX) burner, we successfully stabilized an n-heptane low-swirl, non-premixed spray flame across a wide range of equivalence ratios at pressures reaching 250 psia. Our optical diagnostics feature a temporally gated diffused-backlight illumination extinction imaging (DBI-EI) system, equipped with a 470-nm strobe high-intensity LED array as the illumination source, along with a line-of-sight telecentric camera. By accessing the flame tube, the pulsed DBI-EI provides illuminating optical extinction images, enabling experimental estimation of soot volume fractions within the reaction zone. This imaging technique will allow for real-time observation of soot formation dynamics occurring above the air-blast fuel injector. To further enhance our analysis, we employed simultaneous gaseous and particulate extractive diagnostics, interpreting in-flame particulate information through CO2 sampling, exhaust particle sizing, and particle counting. The processed dataset reveals a promising application of DBI-EI for propulsion emission analysis in high-pressure environments, where optical beam-steering effects can significantly impact results. This report is essential to bridging the divide between in-flame optical diagnostics and exhaust extractive measurements. By achieving an understanding of non-premixed combustion emission characteristics, we attempt to provide invaluable data for computer code validation, advancing the field of combustion research and supporting the development of cleaner, more efficient engines.

high-pressure flame↗

Particulate Emission and Optical Measurements in n-Heptane Low-Swirl Non-Premixed Flames at Elevated Pressures

A series of ground combustion tests conducted at elevated pressures demonstrates in-chamber optical measurements of soot emissions, combined with conventional gaseous and particle emissions sampling techniques. Utilizing a micro-radial-entry counter-swirl (MRX) burner, we successfully stabilized an n-heptane low-swirl, non-premixed spray flame across a wide range of equivalence ratios at pressures reaching 250 psia. Our optical diagnostics feature a temporally gated diffused-backlight illumination extinction imaging (DBI-EI) system, equipped with a 470-nm strobe high-intensity LED array as the illumination source, along with a line-of-sight telecentric camera. By accessing the flame tube, the pulsed DBI-EI provides illuminating optical extinction images, enabling experimental estimation of soot volume fractions within the reaction zone. This imaging technique will allow for real-time observation of soot formation dynamics occurring above the air-blast fuel injector. To further enhance our analysis, we employed simultaneous gaseous and particulate extractive diagnostics, interpreting in-flame particulate information through CO2 sampling, exhaust particle sizing, and particle counting. The processed dataset reveals a promising application of DBI-EI for propulsion emission analysis in high-pressure environments, where optical beam-steering effects can significantly impact results. This report is essential to bridging the divide between in-flame optical diagnostics and exhaust extractive measurements. By achieving an understanding of non-premixed combustion emission characteristics, we attempt to provide invaluable data for computer code validation, advancing the field of combustion research and supporting the development of cleaner, more efficient engines.

high-pressure flame↗