Engineering PapersSearch

SEARCH · Engineering Papers

Results for “parametric amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Optical Parametric Technology for Methane Measurements

Atmospheric methane (CH4) is the second most important anthropogenic greenhouse gas, with approximately 25 times the radiative forcing of carbon dioxide (CO2) per molecule. Yet, lack of understanding of the processes that control CH4 sources and sinks and its potential release from stored carbon reservoirs contributes significant uncertainty to our knowledge of the interaction between carbon cycle and climate change. At Goddard Space Flight Center (GSFC) we have been developing the technology needed to remotely measure CH4 from orbit. Our concept for a CH4 lidar is a nadir viewing instrument that uses the strong laser echoes from the Earth's surface to measure CH4. The instrument uses a tunable, narrow-frequency light source and photon-sensitive detector to make continuous measurements from orbit, in sunlight and darkness, at all latitudes and can be relatively immune to errors introduced by scattering from clouds and aerosols. Our measurement technique uses Integrated Path Differential Absorption (IPDA), which measures the absorption of laser pulses by a trace gas when tuned to a wavelength coincident with an absorption line. We have already demonstrated ground-based and airborne CH4 detection using Optical Parametric Amplifiers (OPA) at 1651 nm using a laser with approximately 10 microJ/pulse at 5kHz with a narrow linewidth. Next, we will upgrade our OPO system to add several more wavelengths in preparation for our September 2015 airborne campaign, and expect that these upgrades will enable CH4 measurements with 1% precision (10-20 ppb).

oscillator

Toward Large Field-of-view X-ray Spectrometers with Magnetic Microcalorimeters

A future X-ray telescope mission like Lynx, a X-ray flagship mission concept, requires a large field of view, high energy resolution, and high spatial resolution. The Magnetic Microcalorimeter (MMC) detectors we are developing for such a mission feature a 5-arcminute field of view, approximately 100,000 pixels, each spanning 0.5–1 arcsecond. These detectors require the readout of 8,000 sensors. Three different array types have been designed to meet scientific goals, two of which utilize thermal multiplexing to reduce the number of readout channels in a scheme called “Hydra.” We are currently fabricating detectors on a recently completed buried wiring wafer with connections to every sensor. The sensors are read out using a microwave multiplexer (μMUX) with flux ramp modulation. A single μMUX can read out approximately 1,000 sensors with only two feed lines. We will report on the test of the first two-dimensional μMUX chip, consisting of 78 resonators. μMUX chips that pass screening will be directly bonded to MMC array chips using indium bump bonding. In parallel, we have tested a kinetic inductance traveling wave parametric amplifier (KI-TWPA) to amplify signals at low temperatures. The KI-TWPA exhibits extremely low internal noise, approaching the standard quantum limit. Since the energy resolution of an MMC is primarily limited by the readout system, the KI-TWPA is an ideal amplifier for MMCs with μMUX readout. We recently measured the readout noise of a μMUX with a KI-TWPA, demonstrating its capability for reading out MMC arrays. We present the design and fabrication of the latest MMC detectors, along with its readout performance.

Magntic Microcalorimeters

Application of Twin Beams in Mach-Zehnder Interferometer

Using the twin beams generated from parametric amplifier to drive the two port of a Mach-Zehnder interferometer, it is shown that the minimum detectable optical phase shift can be largly reduced to the Heisenberg limit(1/n) which is far below the Shot Noise Limit(1/square root of n) the large gain limit. The dependence of the minimum detectable phase shift on parametric gain and the inefficient photodetectors has been discussed.

Zhang, J. X.

Improved receiver noise calibration for ADMX axion search: 4.54 to 5.41 μeV

Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Because of the weak coupling of axions to photons, however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra-low-noise electronics. In this paper, we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280 MHz taken during ADMX’s most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and Josephson Parametric Amplifier as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Average Power Effects in Parametric Oscillators and Amplifiers

Thermally induced phase mismatch and thermally induced lensing will limit the average power available from a parametric oscillator or amplifier. Expressions are derived that describe both of these average power effects for the commonly used radial heat extraction as well as for longitudinal heat extraction. It is shown that the effects of thermally induced phase mismatch can be mitigated by a judicious selection of the phase-matching conditions.

Barnes, Norman P.

Axion detection via superfluid 3 He ferromagnetic phase and quantum measurement techniques

We propose to use the nuclear spin excitation in the ferromagnetic A 1 phase of the superfluid 3 He for the axion dark matter detection. This approach is striking in that it is sensitive to the axion-nucleon coupling, one of the most important features of the QCD axion introduced to solve the strong CP problem. We review a quantum mechanical description of the nuclear spin excitation and apply it to the estimation of the axion-induced spin excitation rate. We also describe a possible detection method of the spin excitation in detail and show that the combination of the squeezing of the final state with the Josephson parametric amplifier and the homodyne measurement can enhance the sensitivity. It turns out that this approach gives good sensitivity to the axion dark matter with the mass of $\mathcal{O}$(1) μeV depending on the size of the external magnetic field. We estimate the parameters of experimental setups, e.g., the detector volume and the amplitude of squeezing, required to reach the QCD axion parameter space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Joint Experimental and Computational Characterization of Sum-Frequency Generation between a Continuous Wave Laser and an Ultrafast Frequency Comb Laser for Tunable Laser Development

Ultrafast optical frequency combs allow for both high spectral and temporal resolution in molecular spectroscopy and have become a powerful tool in many areas of chemistry and physics. Ultrafast lasers and frequency combs generated from ultrafast mode-locked lasers often need to be converted to other wavelengths. Commonly used wavelength conversions are optical parametric oscillators, which require an external optical cavity, and supercontinuum generation combined with optical parametric amplifiers. Whether commercial or home-built, these systems are complex and costly. Here, we investigate an alternative, simple, and easy-to-implement approach to tunable frequency comb ultrafast lasers enabled by new continuous-wave laser technology. Sum-frequency generation between an Nd:YAG continuous-wave laser and a Yb:fiber femtosecond frequency comb in a beta-barium borate (BBO) crystal is explored. The resulting sum-frequency beam is a pulsed frequency comb with the same repetition rate as the Yb:fiber source. SNLO simulation software is used to simulate the results and provide benchmarks for designing future systems to achieve wavelength conversion and tunability in otherwise difficult-to-reach spectral regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Measurement of spin-polarized photoemission from wurtzite and zinc blende gallium nitride photocathodes

Spin-polarized photoemission from wurtzite and zinc blende gallium nitride (GaN) photocathodes has been observed and measured. The p-doped GaN photocathodes were epitaxially grown and activated to negative electron affinity with a cesium monolayer deposited on their surfaces. A field-retarding Mott polarimeter was used to measure the spin polarization of electrons photoemitted from the top of the valence band. A spectral scan with a tunable optical parametric amplifier constructed to provide low-bandwidth light revealed peak spin polarizations of 17% and 29% in the wurtzite and zinc blende photocathodes, respectively. Zinc blende GaN results are analyzed with a spin polarization model accounting for experimental parameters used in the measurements, while possible mechanisms influencing the obtained spin polarization values of wurtzite GaN are discussed.

Physics

ADMX Axion Dark Matter Bounds around 3.3 μ eV with Dine-Fischler-Srednicki-Zhitnitsky Discovery Ability

We report the results of a QCD axion dark matter search with discovery ability for Dine-Fischler-Srednicki-Zhitnitsky (DFSZ) axions using an axion haloscope. Sub-Kelvin noise temperatures are reached with an ultralow noise Josephson parametric amplifier cooled by a dilution refrigerator. This work excludes (with a 90% confidence level) DFSZ axions with masses between 3.27 to 3.34 μ eV , assuming a standard halo model with a local energy density of 0.45 G e V / cm 3 made up 100% of axions. Published by the American Physical Society 2025

79 ASTRONOMY AND ASTROPHYSICS

High-repetition rate, CEP-stable shortwave infrared source with two-cycle pulses for field-resolved spectroscopy

We report on a passively carrier-envelope phase (CEP)-stable optical parametric amplifier generating two-cycle pulses at 2060 nm with energies of up to 2.25 µJ operating at a repetition rate of 400 kHz, specifically designed for applications in field-resolved spectroscopy. The measured pulse duration is 13.6 fs, resulting in two cycles of the carrier wave. Due to the robust CEP-stable front-end design, we achieve an open-loop CEP stability of 250 mrad (rms) and the capability for fast CEP modulation.

47 OTHER INSTRUMENTATION

Quantum sensing for fundamental physics efforts at SQMS

One of the areas of research of the Superconducting Quantum Systems and Materials (SQMS) center is the application of quantum sensing to fundamental physics searches, demonstrating that quantum sensors can greatly improve the sensitivity of experiments searching for Beyond the Standard Model (BSM) physics, or performing high-precision measurements. Theorists have developed many ideas for BSM physics that would result in interactions that can in principle be detected, but with signals small enough that they haven t been observed yet. In this field, the capability to lower the detector s thermal noise to few or dozens of mK, and to use QIS technologies such as Josephson Parametric Amplifiers and photon counters (in-situ or itinerant) enable us to reach unprecedented sensitivities and faster scan rates. Here is presented an overview of the quantum sensing efforts at SQMS [1], focusing on theoretical advancements and experimental searches for Dark Sector particles (as dark matter candidates and not), gravitational waves, and precision measurements. The experiments conducted, or under preparation, include axion dark matter (DM) [2, 3], dark photon DM searches [4,5], light-shining-through-wall experiments [6], cavity-based searches for high frequency gravitational waves [7], and measurements of the electron magnetic moment [8]. [1] Berlin, A., et al. "Searches for new particles, dark matter, and gravitational waves with SRF cavities." arXiv preprint arXiv:2203.12714 (2022). [2] Giaccone, B., et al. "Design of axion and axion dark matter searches based on ultra high Q SRF cavities." arXiv preprint arXiv:2207.11346 (2022). [3] Braggio, C., et al. "Quantum-enhanced sensing of axion dark matter with a transmon-based single microwave photon counter." arXiv preprint arXiv:2403.02321 (2024). [4] Fan, X., et al. "One-electron quantum cyclotron as a milli-eV dark-photon detector." Physical review letters 129.26 (2022): 261801. [5] Cervantes, R., et al. "Deepest sensitivity to wavelike dark photon dark matter with superconducting radio frequency cavities." Physical Review D 110.4 (2024): 043022. [6] Romanenko, A., et al. "Search for dark photons with superconducting radio frequency cavities." Physical review letters 130.26 (2023): 261801. [7] Berlin, A., et al. "Electromagnetic cavities as mechanical bars for gravitational waves." Physical Review D 108.8 (2023): 084058. [8] Fan, X., et al. "Measurement of the electron magnetic moment." Physical review letters 130.7 (2023): 071801.

Giaccone, Bianca

Magnonic spontaneous oscillation induced by parametric pumping

Spontaneous dynamic systems have attracted significant attention for their rich underlying physics such as phase-locking and synchronization. In this work, we report a new mechanism of generating magnetic spontaneous oscillation via parametric pumping. By applying a pump tone to excite propagating spin waves in a yttrium iron garnet delay line, four-wave mixing converts the pump mode into two phase-autonomous propagating magnon modes, i.e. a spontaneous mode with nearly twice the wavenumber of the pump mode and an idler mode with nearly zero wavenumber. This allows us to reliably generate ultrasharp spin wave dynamics with broad frequency tunability from the pump and magnetic field. We show that the spontaneous mode can be phase-locked to a probe tone, similar to an auto-oscillator. Furthermore, the spontaneous dynamics can be used to implement a high-gain magnonic parametric amplifier with a gain up to 40 dB. Our results open a new avenue for studying nonlinear magnonics and synchronization physics in propagating magnon geometry and for developing new magnonic devices.

Li, Yi

Parametric amplification by unbiased Josephson junctions

The theory of parametric amplification by a series of unbiased Josephson junctions is presented. The various regimes of operation are explored. This device is different in many ways from the usual varactor parametric amplifier. In particular, a very small pump power is required, and a large bandwidth is obtained. Comparison with experimental data is made.

Feldman, M. J.

Operation of the SUPARAMP at 33GHz

A 9mm degenerate parametric amplifier was constructed using a linear, series array of unbiased Josephson junctions as the active, nonlinear element. A balanced diode mixer was used as a synchronous detector, with a single source serving both as the pump and as the mixer local oscillator. A stable, net gain of 15 dB in an instantaneous bandwith (FWHM) of 3.4 GHz was achieved. A system noise temperature of 220 K + or - 5 K (DSB) was measured with a SUPARAMP contribution of only 20 K x or - 10 K. Output saturation was observed and complicates the interpretation of the noise temperature measurements and may render them upper limits. A comparison was made with the results of an earlier 3 cm suparamp. The data is in substantial agreement with theoretical predictions.

Chiao, R. Y.

Operation of the SUPARAMP at 33 GHz

A 9-mm degenerate parametric amplifier has been constructed using a linear series array of unbiased Josephson junctions as the active nonlinear element. A balanced diode mixer was used as a synchronous detector, with a single source serving both as the pump and as the mixer local oscillator. A stable net gain of 15 dB in an instantaneous bandwidth (FWHM) of 3.4 GHz has been achieved. A system noise temperature of 220 plus or minus 5 K (DSB) was measured with a SUPARAMP contribution of only 20 plus or minus 10 K. Output saturation has been observed. This complicates the interpretation of noise-temperature measurements and may render them upper limits. Comparison is made with the results of an earlier 3-cm SUPARAMP.

Chiao, R. Y.

The low-noise 115-GHz receiver on the Columbia-GISS 4-ft radio telescope

The superheterodyne millimeter-wave radiometer on the Columbia-GISS 4-ft telescope is described. This receiver uses a room-temperature Schottky diode mixer, with a resonant-ring filter as LO diplexer. The diplexer has low signal loss, efficient LO power coupling, and suppresses most of the LO noise at both sidebands. The receiver IF section has a parametric amplifier as its first stage with sufficient gain to overcome the second-stage amplifier noise. A broad-banded quarter-wave impedance transformer minimizes the mismatch between mixer and paramp. At 115 GHz, the SSB receiver noise temperature is 860 K, which is believed to be the lowest figure so far reported for a room-temperature receiver at this frequency.

Cong, H.-I.

Support assembly for cryogenically coolable low-noise choke waveguide

A compact cryogenically coolable choked waveguide for low-noise input coupling into a cryogenically cooled device, such as a maser or parametric amplifier, utilizes coaxial stainless steel support tubes surrounding the waveguide and connected in cascade to provide a folded low thermal conduction path. The edges of the tubes connected are welded.

Mccrea, F. E.