Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical pulse shaping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

An imaging system for PLIF/Mie measurements for a combusting flow

The equipment required to establish an imaging system can be divided into four parts: (1) the light source and beam shaping optics; (2) camera and recording; (3) image acquisition and processing; and (4) computer and output systems. A pulsed, Nd:YAG-pummped, frequency-doubled dye laser which can freeze motion in the flowfield is used for an illumination source. A set of lenses is used to form the laser beam into a sheet. The induced fluorescence is collected by an UV-enhanced lens and passes through an UV-enhanced microchannel plate intensifier which is optically coupled to a gated solid state CCD camera. The output of the camera is simultaneously displayed on a monitor and recorded on either a laser videodisc set of a Super VHS VCR. This videodisc set is controlled by a minicomputer via a connection to the RS-232C interface terminals. The imaging system is connected to the host computer by a bus repeater and can be multiplexed between four video input sources. Sample images from a planar shear layer experiment are presented to show the processing capability of the imaging system with the host computer.

Wey, C. C.↗

Optical Channelizer Evaluation Using Empirical Data and Simulation

Westinghouse Electric Corporation Division under NASA contract NAS3-25865 developed a proof-of-concept (POC) multichannel demultiplexer implemented as an acousto-optic radiofrequency (RF) with a spectrum analyzer. A detailed analysis of the experimental results indicate that the expected degradation caused by the acousto-optical channelizer is approximately 2.0 dB degradation at 10(exp -5) bit-error rate (BER) and 3.0 dB degradation at 10(exp -8) BER. This degradation may be quite acceptable when considering the excellent volume, mass, and power characteristics of acousto-optical channelizing relative to other technologies. In addition, system performance can be greatly improved by using digital pulse shaping in the modem and increasing the channel spacing from 40 to 45 kHz for 64 kbps quadrature phase-shift keying (QPSK) modulation.

Ivancic,William D.↗

Considerations in upconversion: A practical guide to sum-frequency generation spectrometer design and implementation

Here, in this tutorial review, we discuss how the choice of upconversion pulse shape in broadband vibrational sum-frequency generation (SFG) spectrometer design impacts the chemical or physical insights one can obtain from a set of measurements. A time-domain picture of a vibrational coherence being mapped by a second optical field is described and the implications of how this mapping, or upconversion process, takes place are given in the context of several popular and emerging approaches found in the literature. Emphasis is placed on broadband frequency-domain measurements, where the choice of upconversion pulse enhances or limits the information contained in the SFG spectrum. We conclude with an outline for a flexible approach to SFG upconversion using pulse-shaping methods and a simple guide to design and optimize the associated instrumentation.

47 OTHER INSTRUMENTATION↗

Method and circuit for shaping laser output pulses

The invention is a method and circuit for shaping laser output pulses from a laser resonator. A Q-switch and polarizer act in combination to control the loss to the resonator and provide the laser output representative of such loss. An optical diode senses the level of the output pulse and provides an output signal that when amplified is used to control voltage from a supply to provide a control signal which is applied to the Q-switch to control the shape of the output pulse by adjusting its length.

Barnes, Norman P.↗

A search for optical pulsations from GX 1+4 at H-alpha

H-alpha observations of the binary-star candidate for the slowly pulsating hard X-ray source GX 1+4 are reported which were undertaken to search for pulsations in the H-alpha flux that are synchronous with the X-ray period of about 2 min. No significant periodic variation of the candidate star was detected in the frequency band searched. Three-sigma upper limits of 1.7% (sinusoidal pulse shape) and 0.7% (X-ray pulse shape) are set for the pulsed fraction of the H-alpha flux. It is noted that because of possible diffusion from a cloud that is optically thick to Balmer radiation, the observed lack of pulsations in the H-alpha flux need not compromise the identification of GX 1+4 with the candidate star.

Krzeminski, W.↗

Optical shock-enhanced self-photon acceleration

Photon accelerators can spectrally broaden laser pulses with high efficiency in moving electron density gradients driven in a rapidly ionizing plasma. When driven by a conventional laser pulse, the group velocity walk-off experienced by the accelerated photons and deterioration of the gradient from diffraction and plasma-refraction limit the extent of spectral broadening. In this work, we show that a laser pulse with a shaped space-time and transverse intensity profile overcomes these limitations by creating a guiding density pro le at a tunable velocity. Self-photon acceleration in this profile leads to dramatic spectral broadening and intensity steepening, forming an optical shock that further enhances the rate of spectral broadening. In this new regime, multi-octave spectra extending from 400nm to 60nm wavelengths, which support near-transform limited < 400 as pulses, are generated over < 100 μm of interaction length.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optical and X-ray radiation from fast pulsars - Effects of duty cycle and spectral shape

The optical luminosity of PSR 0540 is considerably stronger than what one would have predicted in a simple model developed earlier where the pulses are synchrotron radiation by secondary electrons near the light cylinder. This discrepancy can be eliminated if one incorporates into the model the effects of the large duty cycle and the spectral properties of PSR 0540. It is also shown that the same model can provide a reasonable fit to the observed X-ray fluxes from fast pulsars.

Pacini, F.↗

When do molecular polaritons behave like optical filters?

This review outlines several linear optical effects featured by molecular polaritons arising in the collective strong light–matter coupling regime. Under weak laser irradiation and when the single-molecule light–matter coupling can be neglected (often in the limit when the number of molecules per photon mode is large), we show that the excited-state molecular dynamics under collective strong coupling can be exactly replicated without the cavity using a shaped (or “filtered”) laser, whose field amplitude is enhanced by the cavity quality factor, shining on the bare molecules. As a consequence, the absorption within a cavity can be understood as the overlap between the polariton transmission and the bare molecular absorption, suggesting that polaritons act in part as optical filters. This framework demystifies and provides a straightforward explanation for a large class of experiments and theoretical models in molecular polaritonics, highlighting that the same effects can be achieved without the cavity with shaped laser pulses. With a few modifications, this simple conceptual picture can also be adapted to understand the incoherent nonlinear response of polaritonic systems. This review establishes a clear distinction between polaritonic phenomena that can be fully explained through classical linear optics and those that require a quantum electrodynamics approach. It also highlights the need to differentiate between effects that necessitate polaritons (i.e., hybrid light–matter states) and those that can occur in the weak coupling regime. Here, we further discuss that certain quantum optical effects like fluorescence can be partially described as optical filtering, whereas some others like cavity-induced Raman scattering go beyond this. Further exploration in these areas is needed to uncover novel polaritonic phenomena beyond optical filtering.

Schwennicke, Kai [University of California, San Di↗

Resonant propagation of extreme-ultraviolet pulses through strongly driven high-density media

We show that by combining strong-field dressing and resonant propagation of XUV pulses, the transition of absorption lines from their natural Lorentzian profiles through Fano and complex multipeak shapes all the way back to broadened near-Lorentzian profiles can be achieved, in the limit of optically thick samples. The final stage of this spectral modification can be understood in terms of a significant temporal stretching and delay of the resonant XUV pulse as it propagates through the dense gas, which alters the ultrafast absorption that is modified by the time-synchronized few-femtosecond laser pulse. We first demonstrate this concept in numerical calculations, both using a model system and through a fully coupled solution of the time-dependent Schrödinger equation and the Maxwell wave equation. The applicability and generality of the underlying mechanism is then illustrated in proof-of-principle attosecond transient absorption measurements in a helium gas with a widely varying atomic density. These results provide insights into the interaction of ultrashort laser pulses with dense media and its coherent control. Published by the American Physical Society 2025

He, Yu (ORCID:0000000152120176)↗

Longitudinal shaping of plasma waveguides using diffractive axicons for laser wakefield acceleration

New techniques for the optical generation of plasma waveguides—optical fibers for ultra-intense light pulses—have become vital to the advancement of multi-GeV laser wakefield acceleration. Here, we demonstrate the fabrication and characterization of a transmissive 8-level logarithmic diffractive axicon (LDA) for the generation of meter-scale plasma waveguides. These LDAs enable the formation of a Bessel-like beam with controllable start and end locations of the focal line and near-constant intensity on axis. We present measurements of the Bessel-like focal profile produced by the LDA and of the leading end of the plasma column generated by it. One important feature is the formation of a funnel-mouthed plasma channel entrance that can act as waveguide coupler. We also compare the diffraction efficiency of our 8-level LDA to 4-level and binary versions, with measurements comparing well to theory.

Tripathi, N.↗

Pulsed Lidar Measurements of Atmospheric CO2 Column Absorption in the ASCENDS 2011 Airborne Campaign

We have previously demonstrated an efficient pulsed, wavelength-resolved IPDA lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's ASCENDS mission. Our team participated in the 2010 ASCENDS airborne campaigns we flew airborne version of the CO2 and O2 lidar on the NASA DC-8. The CO2 lidar measures the atmospheric backscatter profiles and shape of the 1572.33 nm absorption line using 250 mW average laser power, 30 wavelength samples per scan and 300 scans per second. Most flights had 5-6 altitude steps to greater than 12 km, and clear CO2 line shapes were observed at all altitudes. Our post-flight analysis estimated the Iidar range and pulse energies at each wavelength every second. We then solved for the best-fit CO2 absorption line shape, and calculated the Differential Optical Depth (DOD) at the line peak. We compared these to CO2 DODs calculated from spectroscopy based on HITRAN 2008 and the conditions from airborne in-situ readings. Analysis of the 2010 measurements over the Pacific Ocean and Lamont OK shows the expected -linear change of the peak DOD with altitude. For measurements at altitudes greater than 6 km the random errors were approximately 0.3 ppm for 80 sec averaging times. After the 2010 flights we improved the airborne lidar's scan uniformity, calibration and receiver sensitivity. Our team participated in the seven ASCENDS science flights during late July and August 2011. These flights were made over a wide variety of surface and cloud conditions near the US, including over the central valley of California, over several mountain ranges, over both broken and solid stratus cloud deck over the Pacific Ocean, snow patches on mountain tops, over thin and broken clouds above the US Southwest and Iowa, and over forests near the WLEF tower in Wisconsin. Analyses show the retrievals of lidar range and CO2 column absorption, as wen as estimates of CO2 mixing ratio worked well when measuring over topography with rapidly changing height and reflectivity, through thin clouds and to stratus cloud tops. For regions where the CO2 concentration was relatively constant, the measured CO2 absorption profile (averaged for 50 sec) matched the predicted profile to better than 1% RMS error for all flight altitudes. For 1 & 10 second averaging, the scatter in the retrievals was limited by signal shot noise (i.e. the sigual photon count). Analysis to date shows the decrease in CO2 due to vegetation when flying easterward over the Great Plains as well as the increase in CO2 concentration in the vicinity ofthe coal-fired power plant in New Mexico. Examples of these and other results will be presented.

Abshire, James B.↗

Analysis of Pulsed Lidar Measurements of Atmospheric CO2 Column Absorption During the ASCENDS 2009-2011 Airborne Campaigns

We have developed a pulsed lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's ASCENDS mission and have demonstrated the CO2 and O2 measurements from aircraft. Our technique uses two pulsed lasers allowing simultaneous measurement of a single CO2 absorption line near 1572 nm, O2 extinction in the Oxygen A-band, surface height and backscatter profile. The lasers are stepped in wavelength across the CO2 line and an O2 line doublet during the measurement. The column densities for the CO2 and O2 are estimated from the differential optical depths (DOD) of the scanned absorption lines via the IPDA technique. For the 2009 ASCENDS campaign we flew the CO2 lidar on a Lear-25 aircraft, and measured the absorption line shapes of the CO2 line using 20 wavelength samples per scan. Measurements were made at stepped altitudes from 3 to 12.6 km over the Lamont OK, central Illinois, North Carolina, and over the Virginia Eastern Shore. Although the received signal energies were weaker than expected for ASCENDS, clear CO2 line shapes were observed at all altitudes. Most flights had 5-6 altitude steps with 200-300 seconds of recorded measurements per step. We averaged every 10 seconds of measurements and used a cross-correlation approach to estimate the range to the scattering surface and the echo pulse energy at each wavelength. We then solved for the best-fit CO2 absorption line shape, and calculated the DOD of the fitted CO2 line, and computed its statistics at the various altitude steps. We compared them to CO2 optical depths calculated from spectroscopy based on HITRAN 2008 and the column number densities calculated from the airborne in-situ readings. The 2009 measurements have been analyzed and they were similar on all flights. The results show clear CO2 line shape and absorption signals, which follow the expected changes with aircraft altitude from 3 to 13 km. They showed the expected nearly the linear dependence of DOD vs altitude. The measurements showed ~ 1 ppm random errors for 8-10 km altitudes and ~30 sec averaging times. For the 2010 ASCENDS campaigns we flew the CO2lidar on the NASA DC-8 and added an 02lidar channel. During July 2010 we made measurements of CO2 and O2 column absorption during longer flights over Railroad Valley NV, the Pacific Ocean and over Lamont OK. CO2 measurements were made with 30 steps/scan, 300 scans/sec and improved line resolution and receiver sensitivity. Analysis of the 2010 CO2 measurements shows the expected ~linear change of DOD with altitude. For measurements at altitudes> 6 km the random errors were 0.3 ppm for 80 sec averaging times. For the summer 2011 ASCENDS campaigns we made further improvements to the lidar's CO2 line scan and receiver sensitivity. We demonstrated measurements over the California Central Valley, to stratus cloud tops over the Pacific Ocean, over mountain regions with snow, and over several areas with broken clouds. Details of the lidar measurements and their analysis will be described in the presentation.

Abshire, J. B.↗

Pulsed Lidar Measurements of Atmospheric CO2 Column Absorption and Range During the ASCENDS 2009-2011 Airborne Campaigns

We have developed a pulsed lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's ASCENDS mission and have demonstrated the CO2 and O2 measurements from aircraft. Our technique uses two pulsed lasers allowing simultaneous measurement of a single CO2 absorption line near 1572 nm, O2 extinction in the Oxygen A-band, surface height and backscatter profile. The lasers are stepped in wavelength across the CO2 line and an O2 line doublet during the measurement. The column densities for the CO2 and O2 are estimated from the differential optical depths (DOD) of the scanned absorption lines via the IPDA technique. For the 2009 ASCENDS campaign we flew the CO2 lidar only on a Lear-25 aircraft, and measured the absorption line shapes of the CO2 line using 20 wavelength samples per scan. Measurements were made at stepped altitudes from 3 to 12.6 km over the Lamont OK, central Illinois, North Carolina, and over the Virginia Eastern Shore. Although the received signal energies were weaker than expected for ASCENDS, clear C02 line shapes were observed at all altitudes. Most flights had 5-6 altitude steps with 200-300 seconds of recorded measurements per step. We averaged every 10 seconds of measurements and used a cross-correlation approach to estimate the range to the scattering surface and the echo pulse energy at each wavelength. We then solved for the best-fit CO2 absorption line shape, and calculated the DOD of the fitted CO2 line, and computed its statistics at the various altitude steps. We compared them to CO2 optical depths calculated from spectroscopy based on HITRAN 2008 and the column number densities calculated from the airborne in-situ readings. The 2009 measurements have been analyzed in detail and they were similar on all flights. The results show clear CO2 line shape and absorption signals, which follow the expected changes with aircraft altitude from 3 to 13 km. They showed the expected nearly the linear dependence of DOD vs altitude. The measurements showed -1 ppm random errors for 8-10 km altitudes and -30 sec averaging times. For the 2010 ASCENDS campaigns we flew the CO2 lidar on the NASA DC-8 and added an O2 lidar channel. During July 2010 we made measurements of CO2 and O2 column absorption during longer flights over Railroad Valley NV, the Pacific Ocean and over Lamont OK. CO2 measurements were made with 30 steps/scan, 300 scans/sec and improved line resolution and receiver sensitivity. Analysis of the 2010 CO2 measurements shows the expected -linear change of DOD with altitude. For measurements at altitudes> 6 km the random errors were 0.3 ppm for 80 sec averaging times. For the summer 2011 ASCENDS campaigns we made further improvements to the lidar's CO2 line scan and receiver sensitivity. The seven flights in the 2011 Ascends campaign were flown over a wide variety of surface and cloud conditions in the US, which produced a wide variety of lidar signal conditions. Details of the lidar measurements and their analysis will be described in the presentation.

Abshire, J. B.↗

Nanoindentation-Enhanced Tip-Enhanced Raman Spectroscopy

We combine nanoindentation, herein achieved using atomic force microscopy (AFM)-based pulsed-force lithography, with tip-enhanced Raman spectroscopy (TERS) and imaging. Our approach entails indentation and multimodal characterization of otherwise flat Au substrates, followed by chemical functionalization and TERS spectral imaging of the indented nanostructures. We find that the resulting structures, which vary in shape and size depending on the tip used to produce them, may sustain nano-confined and significantly enhanced local fields. We take advantage of the latter and illustrate TERS-based ultrasensitive detection/chemical fingerprinting as well as chemical reaction imaging – all using a single platform for nano-lithography, topographic imaging, hyperspectral dark field optical microscopy, and TERS.

Wang, Chih-Feng↗

Method and circuit for shaping laser output pulses

The invention is a method and circuit for shaping laser pulses 17' in which a laser medium 12' in a laser resonator 10' that includes a Q-switch 14' and polarizer 13' which act in combination to control the loss of the resonator 10' and provide the laser output 17' representative of such loss. An optical diode 22' senses the level of the output pulse 17' and provides an output signal 23' that when amplified is used with a control voltage from a supply 29' provide a control signal 19' which is applied to Q-switch 14' to control the shape of the output pulse 17' by adjusting its length.

Barnes, Norman P.↗

Characterization of ORNL PSD ASIC

The performance of the ORNL ASIC and its readout system was tested with pixelated organic scintillators. We use a pixelated trans-Stilbene scintillator array from Inrad Optics and a pixelated organic glass scintillator array developed at Sandia National Laboratories to characterize the energy and timing resolutions and the pulse-shape discrimination (PSD) figure-of-merit (FoM). The results are compared to previous work in which the same metrics were measured on waveforms digitized at 250 MHz with 14-bit resolution. We found that the PSD FoM at 340 keVee of the ASIC configuration compared to waveform data varied with the scintillator type. We measured a PSD FoM of 1.12 ± 0.14 with the ASIC configuration versus 1.39 ± 0.23 with waveform data using the trans-Stilbene array. We measured a PSD FoM of 0.52 ± 0.18 with the ASIC configuration versus 1.25 ± 0.19 with waveform data using the the organic glass scintillator array. The coincidence timing resolution was measured using two 6x6x6 mm 3 cubes of trans-Stilbene. It was measured to be 805 ± 9 ps with the ASIC configuration versus 300 ps on average with waveform data.

42 ENGINEERING↗

Efficient Source of Shaped Single Photons Based on an Integrated Diamond Nanophotonic System

An efficient, scalable source of shaped single photons that can be directly integrated with optical fiber networks and quantum memories is at the heart of many protocols in quantum information science. We demonstrate a deterministic source of arbitrarily temporally shaped single-photon pulses with high efficiency [detection efficiency = 14.9 %] and purity [g (2) (0) = 0.0168] and streams of up to 11 consecutively detected single photons using a silicon-vacancy center in a highly directional fiber-integrated diamond nanophotonic cavity. Finally, combined with previously demonstrated spin-photon entangling gates, this system enables on-demand generation of streams of correlated photons such as cluster states and could be used as a resource for robust transmission and processing of quantum information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of large-scale 6 Li-doped pulse-shape discriminating plastic scintillators

A 6 Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ -299-50, has been developed and produced at the kilogram-scale. A total of 44 bars of dimensions 5.5 cm x 5.5 cm x 50 cm of this material have been characterized. Optical properties like light output and effective attenuation length have been found to be comparable to 6 Li-doped liquid scintillators. Further, the scintillator EJ -299-50 shows good neutron detection capabilities with an effective efficiency for capture on 6 Li of approximately 85%. Stability tests performed on two formulation variations showed no intrinsic degradation in the material or optical properties during several months of observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗